Normalized to: Fukuda, K.
[1]
oai:arXiv.org:1908.09985 [pdf] - 2038260
Sub-pixel Response of Double-SOI Pixel Sensors for X-ray Astronomy
Hagino, K.;
Negishi, K.;
Oono, K.;
Yarita, K.;
Kohmura, T.;
Tsuru, T. G.;
Tanaka, T.;
Harada, S.;
Kayama, K.;
Matsumura, H.;
Mori, K.;
Takeda, A.;
Nishioka, Y.;
Yukumoto, M.;
Fukuda, K.;
Hida, T.;
Arai, Y.;
Kurachi, I.;
Kishimoto, S.
Submitted: 2019-08-26
We have been developing the X-ray silicon-on-insulator (SOI) pixel sensor
called XRPIX for future astrophysical satellites. XRPIX is a monolithic active
pixel sensor consisting of a high-resistivity Si sensor, thin SiO$_2$
insulator, and CMOS pixel circuits that utilize SOI technology. Since XRPIX is
capable of event-driven readouts, it can achieve high timing resolution greater
than $\sim 10{\rm ~\mu s}$, which enables low background observation by
adopting the anti-coincidence technique. One of the major issues in the
development of XRPIX is the electrical interference between the sensor layer
and circuit layer, which causes nonuniform detection efficiency at the pixel
boundaries. In order to reduce the interference, we introduce a Double-SOI
(D-SOI) structure, in which a thin Si layer (middle Si) is added to the
insulator layer of the SOI structure. In this structure, the middle Si layer
works as an electrical shield to decouple the sensor layer and circuit layer.
We measured the detector response of the XRPIX with D-SOI structure at KEK. We
irradiated the X-ray beam collimated with $4{\rm ~\mu m\phi}$ pinhole, and
scanned the device with $6{\rm ~\mu m}$ pitch, which is 1/6 of the pixel size.
In this paper, we present the improvement in the uniformity of the detection
efficiency in D-SOI sensors, and discuss the detailed X-ray response and its
physical origins.
[2]
oai:arXiv.org:1905.13620 [pdf] - 1908717
Migration of D-type asteroids from the outer Solar System inferred from
carbonate in meteorites
Submitted: 2019-05-31, last modified: 2019-06-23
Recent dynamical models of Solar System evolution and isotope studies of
rock-forming elements in meteorites have suggested that volatile-rich asteroids
formed in the outer Solar System beyond Jupiter's orbit, despite being
currently located in the main asteroid belt. The ambient temperature under
which asteroids formed is a crucial diagnostic to pinpoint the original
location of asteroids and is potentially determined by the abundance of
volatiles they contain. In particular, abundances and 13C/12C ratios of
carbonates in meteorites record the abundances of carbon-bearing volatile
species in their parent asteroids. However, the sources of carbon for these
carbonates remain poorly understood. Here we show that the Tagish Lake
meteorite contains abundant carbonates with consistently high 13C/12C ratios.
The high abundance of 13C-rich carbonates in Tagish Lake excludes organic
matter as their main carbon source. Therefore, the Tagish Lake parent body,
presumably a D-type asteroid, must have accreted a large amount of 13C-rich CO2
ice. The estimated 13C/12C and CO2/H2O ratios of ice in Tagish Lake are similar
to those of cometary ice. Thus, we infer that at least some D-type asteroids
formed in the cold outer Solar System and were subsequently transported into
the inner Solar System owing to an orbital instability of the giant planets.
[3]
oai:arXiv.org:1905.13381 [pdf] - 1953537
Measurement of Charge Cloud Size in X-ray SOI Pixel Sensors
Hagino, Kouichi;
Oono, Kenji;
Negishi, Kousuke;
Yarita, Keigo;
Kohmura, Takayoshi;
Tsuru, Takeshi G.;
Tanaka, Takaaki;
Uchida, Hiroyuki;
Harada, Sodai;
Okuno, Tomoyuki;
Kayama, Kazuho;
Amano, Yuki;
Matsumura, Hideaki;
Mori, Koji;
Takeda, Ayaki;
Nishioka, Yusuke;
Fukuda, Kohei;
Hida, Takahiro;
Yukumoto, Masataka;
Arai, Yasuo;
Kurachi, Ikuo;
Miyoshi, Toshinobu;
Kishimoto, Shunji
Submitted: 2019-05-30
We report on a measurement of the size of charge clouds produced by X-ray
photons in X-ray SOI (Silicon-On-Insulator) pixel sensor named XRPIX. We carry
out a beam scanning experiment of XRPIX using a monochromatic X-ray beam at 5.0
keV collimated to $\sim 10$ $\mu$m with a 4-$\mu$m$\phi$ pinhole, and obtain
the spatial distribution of single-pixel events at a sub-pixel scale. The
standard deviation of charge clouds of 5.0 keV X-ray is estimated to be
$\sigma_{\rm cloud} = 4.30 \pm 0.07$ $\mu$m. Compared to the detector response
simulation, the estimated charge cloud size is well explained by a combination
of photoelectron range, thermal diffusion, and Coulomb repulsion. Moreover, by
analyzing the fraction of multi-pixel events in various energies, we find that
the energy dependence of the charge cloud size is also consistent with the
simulation.
[4]
oai:arXiv.org:1905.10829 [pdf] - 1953532
Subpixel Response of SOI Pixel Sensor for X-ray Astronomy with Pinned
Depleted Diode: First Result from Mesh Experiment
Kayama, Kazuho;
Tsuru, Takeshi G.;
Tanaka, Takaaki;
Uchida, Hiroyuki;
Harada, Sodai;
Okuno, Tomoyuki;
Amano, Yuki;
Hiraga, Junko S.;
Yoshida, Masayuki;
Kamata, Yasuaki;
Sakuma, Shotaro;
Yuhi, Daito;
Urabe, Yukino;
Tsunemi, Hiroshi;
Matsumura, Hideaki;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Shrestha, Sumeet;
Nakanishi, Syunta;
Kamehama, Hiroki;
Arai, Yasuo;
Kurachi, Ikuo;
Takeda, Ayaki;
Mori, Koji;
Nishioka, Yusuke;
Fukuda, Kohei;
Hida, Takahiro;
Yukumoto, Masataka;
Kohmura, Takayoshi;
Hagino, Kouichi;
Oono, Kenji;
Negishi, Kousuke;
Yarita, Keigo
Submitted: 2019-05-26
We have been developing a monolithic active pixel sensor, ``XRPIX``, for the
Japan led future X-ray astronomy mission ``FORCE`` observing the X-ray sky in
the energy band of 1-80 keV with angular resolution of better than 15``. XRPIX
is an upper part of a stack of two sensors of an imager system onboard FORCE,
and covers the X-ray energy band lower than 20 keV. The XRPIX device consists
of a fully depleted high-resistivity silicon sensor layer for X-ray detection,
a low resistivity silicon layer for CMOS readout circuit, and a buried oxide
layer in between, which is fabricated with 0.2 $\mu$ m CMOS
silicon-on-insulator (SOI) technology. Each pixel has a trigger circuit with
which we can achieve a 10 $\mu$ s time resolution, a few orders of magnitude
higher than that with X-ray astronomy CCDs. We recently introduced a new type
of a device structure, a pinned depleted diode (PDD), in the XRPIX device, and
succeeded in improving the spectral performance, especially in a readout mode
using the trigger function. In this paper, we apply a mesh experiment to the
XRPIX devices for the first time in order to study the spectral response of the
PDD device at the subpixel resolution. We confirmed that the PDD structure
solves the significant degradation of the charge collection efficiency at the
pixel boundaries and in the region under the pixel circuits, which is found in
the single SOI structure, the conventional type of the device structure. On the
other hand, the spectral line profiles are skewed with low energy tails and the
line peaks slightly shift near the pixel boundaries, which contribute to a
degradation of the energy resolution.
[5]
oai:arXiv.org:1904.12571 [pdf] - 1874661
Evaluation of Kyoto's Event-Driven X-ray Astronomical SOI Pixel Sensor
with a Large Imaging Area
Hayashi, Hideki;
Tsuru, Takeshi Go;
Tanaka, Takaaki;
Uchida, Hiroyuki;
Matsumura, Hideaki;
Tachibana, Katsuhiro;
Harada, Sodai;
Takeda, Ayaki;
Mori, Koji;
Nishioka, Yusuke;
Takebayashi, Nobuaki;
Yokoyama, Shoma;
Fukuda, Kohei;
Arai, Yasuo;
Kurachi, Ikuo;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Shrestha, Sumeet;
Nakanishi, Syunta;
Kamehama, Hiroki;
Kohmura, Takayoshi;
Hagino, Kouichi;
Negishi, Kousuke;
Oono, Kenji;
Yarita, Keigo
Submitted: 2019-04-29
We have been developing monolithic active pixel sensors, named ``XRPIX'',
based on the silicon-on-insulator (SOI) pixel technology for future X-ray
astronomy satellites. XRPIX has the function of event trigger and hit address
outputs. This function allows us to read out analog signals only of hit pixels
on trigger timing, which is referred to as the event-driven readout mode.
Recently, we processed ``XRPIX5b'' with the largest imaging area of 21.9~mm
$\times$ 13.8~mm in the XRPIX series. X-ray spectra are successfully obtained
from all the pixels, and the readout noise is 46~e$^-$~(rms) in the frame
readout mode. The gain variation was measured to be 1.2\%~(FWHM) among the
pixels. We successfully obtain the X-ray image in the event-driven readout
mode.
[6]
oai:arXiv.org:1812.05803 [pdf] - 1798380
Performance of SOI Pixel Sensors Developed for X-ray Astronomy
Tanaka, Takaaki;
Tsuru, Takeshi Go;
Uchida, Hiroyuki;
Harada, Sodai;
Okuno, Tomoyuki;
Kayama, Kazuho;
Amano, Yuki;
Matsumura, Hideaki;
Takeda, Ayaki;
Mori, Koji;
Nishioka, Yusuke;
Fukuda, Kohei;
Hida, Takahiro;
Yukumoto, Masataka;
Arai, Yasuo;
Kurachi, Ikuo;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Shrestha, Sumeet;
Nakanishi, Syunta;
Kamehama, Hiroki;
Kohmura, Takayoshi;
Hagino, Kouichi;
Negishi, Kousuke;
Oono, Kenji;
Yarita, Keigo
Submitted: 2018-12-14
We have been developing monolithic active pixel sensors for X-rays based on
the silicon-on-insulator technology. Our device consists of a low-resistivity
Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and
a SiO$_2$ layer between them. This configuration allows us both high-speed
readout circuits and a thick (on the order of $100~\mu{\rm m}$) depletion layer
in a monolithic device. Each pixel circuit contains a trigger output function,
with which we can achieve a time resolution of $\lesssim 10~\mu{\rm s}$. One of
our key development items is improvement of the energy resolution. We recently
fabricated a device named XRPIX6E, to which we introduced a pinned depleted
diode (PDD) structure. The structure reduces the capacitance coupling between
the sensing area in the sensor layer and the pixel circuit, which degrades the
spectral performance. With XRPIX6E, we achieve an energy resolution of $\sim
150$~eV in full width at half maximum for 6.4-keV X-rays. In addition to the
good energy resolution, a large imaging area is required for practical use. We
developed and tested XRPIX5b, which has an imaging area size of $21.9~{\rm mm}
\times 13.8~{\rm mm}$ and is the largest device that we ever fabricated. We
successfully obtain X-ray data from almost all the $608 \times 384$ pixels with
high uniformity.
[7]
oai:arXiv.org:1810.10793 [pdf] - 1875243
X-ray response evaluation in subpixel level for X-ray SOI pixel
detectors
Negishi, Kousuke;
Kohmura, Takayoshi;
Hagino, Kouichi;
Kogiso, Taku;
Oono, Kenji;
Yarita, Keigo;
Sasaki, Akinori;
Tamasawa, Koki;
Tsuru, Takeshi G.;
Tanaka, Takaaki;
Matsumura, Hideaki;
Tachibana, Katsuhiro;
Hayashi, Hideki;
Harada, Sodai;
Mori, Koji;
Takeda, Ayaki;
Nishioka, Yusuke;
Takebayashi, Nobuaki;
Yokoyama, Shoma;
Fukuda, Kohei;
Arai, Yasuo;
Miyoshi, Toshinobu;
Kishimoto, Shunji;
Kurachi, Ikuo
Submitted: 2018-10-25
We have been developing event-driven SOI Pixel Detectors, named `XRPIX'
(X-Ray soiPIXel) based on the silicon-on-insulator (SOI) pixel technology, for
the future X-ray astronomical satellite with wide band coverage from 0.5 keV to
40 keV. XRPIX has event trigger output function at each pixel to acquire a good
time resolution of a few $\mu \rm s$ and has Correlated Double Sampling
function to reduce electric noises. The good time resolution enables the XRPIX
to reduce Non X-ray Background in the high energy band above 10\,keV
drastically by using anti-coincidence technique with active shield counters
surrounding XRPIX. In order to increase the soft X-ray sensitivity, it is
necessary to make the dead layer on the X-ray incident surface as thin as
possible. Since XRPIX1b, which is a device at the initial stage of development,
is a front-illuminated (FI) type of XRPIX, low energy X-ray photons are
absorbed in the 8 $\rm \mu$m thick circuit layer, lowering the sensitivity in
the soft X-ray band. Therefore, we developed a back-illuminated (BI) device
XRPIX2b, and confirmed high detection efficiency down to 2.6 keV, below which
the efficiency is affected by the readout noise. In order to further improve
the detection efficiency in the soft X-ray band, we developed a
back-illuminated device XRPIX3b with lower readout noise. In this work, we
irradiated 2--5 keV X-ray beam collimated to 4 $\rm \mu m \phi$ to the sensor
layer side of the XRPIX3b at 6 $\rm \mu m$ pitch. In this paper, we reported
the uniformity of the relative detection efficiency, gain and energy resolution
in the subpixel level for the first time. We also confirmed that the variation
in the relative detection efficiency at the subpixel level reported by
Matsumura et al. has improved.
[8]
oai:arXiv.org:1810.09193 [pdf] - 1875238
Proton Radiation Damage Experiment for X-Ray SOI Pixel Detectors
Yarita, Keigo;
Kohmura, Takayoshi;
Hagino, Kouichi;
Kogiso, Taku;
Oono, Kenji;
Negishi, Kousuke;
Tamasawa, Koki;
Sasaki, Akinori;
Yoshiki, Satoshi;
Tsuru, Takeshi Go;
Tanaka, Takaaki;
Matsumura, Hideaki;
Tachibana, Katsuhiro;
Hayashi, Hideki;
Harada, Sodai;
Takeda, Ayaki;
Mori, Koji;
Nishioka, Yusuke;
Takebayashi, Nobuaki;
Yokoyama, Shoma;
Fukuda, Kohei;
Arai, Yasuo;
Miyoshi, Toshinobu;
Kurachi, Ikuo;
Hamano, Tsuyoshi;
group, the SOIPIX
Submitted: 2018-10-22
In low earth orbit, there are many cosmic rays composed primarily of high
energy protons. These cosmic rays cause surface and bulk radiation effects,
resulting in degradation of detector performance. Quantitative evaluation of
radiation hardness is essential in development of X-ray detectors for
astronomical satellites. We performed proton irradiation experiments on newly
developed X-ray detectors called XRPIX based on silicon-on-insulator technology
at HIMAC in National Institute of Radiological Sciences. We irradiated 6 MeV
protons with a total dose of 0.5 krad, equivalent to 6 years irradiation in
orbit. As a result, the gain increases by 0.2% and the energy resolution
degrades by 0.5%. Finally we irradiated protons up to 20 krad and found that
detector performance degraded significantly at 5 krad. With 5 krad irradiation
corresponding to 60 years in orbit, the gain increases by 0.7% and the energy
resolution worsens by 10%. By decomposing into noise components, we found that
the increase of the circuit noise is dominant in the degradation of the energy
resolution.
[9]
oai:arXiv.org:1809.10425 [pdf] - 1875215
Performance of the Silicon-On-Insulator Pixel Sensor for X-ray
Astronomy, XRPIX6E, Equipped with Pinned Depleted Diode Structure
Harada, Sodai;
Tsuru, Takeshi Go;
Tanaka, Takaaki;
Uchida, Hiroyuki;
Matsumura, Hideaki;
Tachibana, Katsuhiro;
Hayashi, Hideki;
Takeda, Ayaki;
Mori, Koji;
Nishioka, Yusuke;
Takebayashi, Nobuaki;
Yokoyama, Shoma;
Fukuda, Kohei;
Arai, Yasuo;
Kurachi, Ikuo;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Shrestha, Sumeet;
Nakanishi, Syunta;
Kamehama, Hiroki;
Kohmura, Takayoshi;
Hagino, Kouichi;
Negishi, Kousuke;
Oono, Kenji;
Yarita, Keigo
Submitted: 2018-09-27
We have been developing event driven X-ray Silicon-On-Insulator (SOI) pixel
sensors, called "XRPIX", for the next generation of X-ray astronomy satellites.
XRPIX is a monolithic active pixel sensor, fabricated using the SOI CMOS
technology, and is equipped with the so-called "Event-Driven readout", which
allows reading out only hit pixels by using the trigger circuit implemented in
each pixel. The current version of XRPIX has lower spectral performance in the
Event-Driven readout mode than in the Frame readout mode, which is due to the
interference between the sensor layer and the circuit layer. The interference
also lowers the gain. In order to suppress the interference, we developed a new
device, "XRPIX6E" equipped with the Pinned Depleted Diode structure. A
sufficiently highly-doped buried p-well is formed at the interface between the
buried oxide layer and the sensor layer, and acts as a shield layer. XRPIX6E
exhibits improved spectral performances both in the Event-Driven readout mode
and in the Frame readout mode in comparison to previous devices. The energy
resolutions in full width at half maximum at 6.4 keV are 236 $\pm$ 1 eV and 335
$\pm$ 4 eV in the Frame and Event-Driven readout modes, respectively. There are
differences between the readout noise and the spectral performance in the two
modes, which suggests that some mechanism still degrades the performance in the
Event-Driven readout mode.
[10]
oai:arXiv.org:1807.11005 [pdf] - 1724281
Kyoto's Event-Driven X-ray Astronomy SOI pixel sensor for the FORCE
mission
Tsuru, Takeshi G.;
Hayashi, Hideki;
Tachibana, Katsuhiro;
Harada, Sodai;
Uchida, Hiroyuki;
Tanaka, Takaaki;
Arai, Yasuo;
Kurachi, Ikuo;
Mori, Koji;
Takeda, Ayaki;
Nishioka, Yusuke;
Takebayashi, Nobuaki;
Yokoyama, Shoma;
Fukuda, Kohei;
Kohmura, Takayoshi;
Hagino, Kouichi;
Ohno, Kenji;
Negishi, Kohsuke;
Yarita, Keigo;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Shrestha, Sumeet;
Nakanishi, Shunta;
Kamehama, Hiroki;
Matsumura, Hideaki
Submitted: 2018-07-29
We have been developing monolithic active pixel sensors, X-ray Astronomy SOI
pixel sensors, XRPIXs, based on a Silicon-On-Insulator (SOI) CMOS technology as
soft X-ray sensors for a future Japanese mission, FORCE (Focusing On
Relativistic universe and Cosmic Evolution). The mission is characterized by
broadband (1-80 keV) X-ray imaging spectroscopy with high angular resolution
($<15$~arcsec), with which we can achieve about ten times higher sensitivity in
comparison to the previous missions above 10~keV. Immediate readout of only
those pixels hit by an X-ray is available by an event trigger output function
implemented in each pixel with the time resolution higher than $10~{\rm \mu
sec}$ (Event-Driven readout mode). It allows us to do fast timing observation
and also reduces non-X-ray background dominating at a high X-ray energy band
above 5--10~keV by adopting an anti-coincidence technique. In this paper, we
introduce our latest results from the developments of the XRPIXs. (1) We
successfully developed a 3-side buttable back-side illumination device with an
imaging area size of 21.9~mm$\times$13.8~mm and an pixel size of $36~{\rm \mu
m} \times 36~{\rm \mu m}$. The X-ray throughput with the device reaches higher
than 0.57~kHz in the Event-Driven readout mode. (2) We developed a device using
the double SOI structure and found that the structure improves the spectral
performance in the Event-Driven readout mode by suppressing the capacitive
coupling interference between the sensor and circuit layers. (3) We also
developed a new device equipped with the Pinned Depleted Diode structure and
confirmed that the structure reduces the dark current generated at the
interface region between the sensor and the SiO$_2$ insulator layers. The
device shows an energy resolution of 216~eV in FWHM at 6.4~keV in the
Event-Driven readout mode.
[11]
oai:arXiv.org:1410.2377 [pdf] - 878528
PoGOLino: a scintillator-based balloon-borne neutron detector
Kole, Merlin;
Chauvin, Maxime;
Fukazawa, Yasushi;
Fukuda, Kentaro;
Ishizu, Sumito;
Jackson, Miranda;
Kamae, Tune;
Kawaguchi, Noriaki;
Kawano, Takafumi;
Kiss, Mozsi;
Moretti, Elena;
Pearce, Mark;
Rydström, Stefan;
Takahashi, Hiromitsu;
Yanagida, Takayuki
Submitted: 2014-10-09
PoGOLino is a balloon-borne scintillator-based experiment developed to study
the largely unexplored high altitude neutron environment at high geomagnetic
latitudes. The instrument comprises two detectors that make use of LiCAF, a
novel neutron sensitive scintillator, sandwiched by BGO crystals for background
reduction. The experiment was launched on March 20th 2013 from the Esrange
Space Centre, Northern Sweden (geomagnetic latitude of $65^\circ$), for a three
hour flight during which the instrument took data up to an altitude of 30.9 km.
The detector design and ground calibration results are presented together with
the measurement results from the balloon flight.
[12]
oai:arXiv.org:1311.5531 [pdf] - 749865
A Balloon-borne Measurement of High Latitude Atmospheric Neutrons Using
a LiCAF Neutron Detector
Kole, Merlin;
Fukazawa, Yasushi;
Fukuda, Kentaro;
Ishizu, Sumito;
Jackson, Miranda;
Kamae, Tune;
Kawaguchi, Noriaki;
Kawano, Takafumi;
Kiss, Mózsi;
Moretti, Elena;
Salinas, Maria Fernanda Muñoz;
Pearce, Mark;
Rydström, Stefan;
Takahashi, Hiromitsu;
Yanagida, Takayuki
Submitted: 2013-11-21
PoGOLino is a scintillator-based neutron detector. Its main purpose is to
provide data on the neutron flux in the upper stratosphere at high latitudes at
thermal and nonthermal energies for the PoGOLite instrument. PoGOLite is a
balloon borne hard X-ray polarimeter for which the main source of background
stems from high energy neutrons. No measurements of the neutron environment for
the planned flight latitude and altitude exist. Furthermore this neutron
environment changes with altitude, latitude and solar activity, three variables
that will vary throughout the PoGOLite flight. PoGOLino was developed to study
the neutron environment and the influences from these three variables upon it.
PoGOLino consists of two Europium doped Lithium Calcium Aluminium Fluoride
(Eu:LiCAF) scintillators, each of which is sandwiched between 2 Bismuth
Germanium Oxide (BGO) scintillating crystals, which serve to veto signals
produced by gamma-rays and charged particles. This allows the neutron flux to
be measured even in high radiation environments. Measurements of neutrons in
two separate energy bands are achieved by placing one LiCAF detector inside a
moderating polyethylene shield while the second detector remains unshielded.
The PoGOLino instrument was launched on March 20th 2013 from the Esrange Space
Center in Northern Sweden to an altitude of 30.9 km. A description of the
detector design and read-out system is presented. A detailed set of simulations
of the atmospheric neutron environment performed using both PLANETOCOSMICS and
Geant4 will also be described. The comparison of the neutron flux measured
during flight to predictions based on these simulations will be presented and
the consequences for the PoGOLite background will be discussed.