Normalized to: Yamashita, M.
[1]
oai:arXiv.org:2006.09721 [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J. R.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Di Stefano, R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Galloway, M.;
Gao, F.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Long, J.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Mancuso, A.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Mizukoshi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Mougeot, X.
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic
recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y
and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y
keV) between 1-30 keV. An excess over known backgrounds is observed below 7
keV, rising towards lower energies and prominent between 2-3 keV. The solar
axion model has a 3.5$\sigma$ significance, and a three-dimensional 90%
confidence surface is reported for axion couplings to electrons, photons, and
nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7
\times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and
$g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either
$g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic
moment signal is similarly favored over background at 3.2$\sigma$ and a
confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.)
is reported. Both results are in strong tension with stellar constraints. The
excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$
significance with a corresponding tritium concentration in xenon of $(6.2 \pm
2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor
excluded with current knowledge of production and reduction mechanisms. The
significances of the solar axion and neutrino magnetic moment hypotheses are
decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained
tritium component is included in the fitting. With respect to bosonic dark
matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68%
C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over
background. This analysis sets the most restrictive direct constraints to date
on pseudoscalar and vector bosonic dark matter for most masses between 1 and
210 keV/c$^2$.
[2]
oai:arXiv.org:2005.11891 [pdf] - 2112667
Search for exotic neutrino-electron interactions using solar neutrinos
in XMASS-I
XMASS collaboration;
Abe, K.;
Chen, Y.;
Hiraide, K.;
Ichimura, K.;
Imaizumi, S.;
Kato, N.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Kim, Y. H.;
Ishii, R.;
Itow, Y.;
Kanzawa, K.;
Martens, K.;
Mason, A.;
Suzuki, Y.;
Miuchi, K.;
Takeuchi, Y.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Ogawa, H.;
Kishimoto, Y.;
Nishijima, K.;
Fushimi, K.;
Xu, B. D.;
Nakamura, S.
Submitted: 2020-05-24
We have searched for exotic neutrino-electron interactions that could be
produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark
photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed
no significant signals in 711 days of data. We obtain an upper limit for
neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level
assuming all three species of neutrino have common millicharge. We also set
flavor dependent limits assuming the respective neutrino flavor is the only one
carrying a millicharge, $7.3 \times 10^{-12} e$ for $\nu_e$, $1.1 \times
10^{-11} e$ for $\nu_{\mu}$, and $1.1 \times 10^{-11} e$ for $\nu_{\tau}$.
These limits are the most stringent yet obtained from direct measurements. We
also obtain an upper limit for the neutrino magnetic moment of
1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for
the coupling constant of dark photons in the $U(1)_{B-L}$ model of
1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$,
and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
[3]
oai:arXiv.org:2003.03825 [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Qin, G. Plante J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Xu, M. Weiss;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly
Interacting Massive Particles have so far shown a relative energy resolution
which degrades with energy above $\sim$200 keV. This has limited their
sensitivity in the search for rare events like the neutrinoless double-beta
decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the
XENON1T dual-phase time projection chamber, we demonstrate that the relative
energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its
one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We
achieve this by using a signal correction method to rectify the saturation
effects of the signal readout system. The very good energy resolution from keV
to MeV energies demonstrated in XENON1T opens up new windows for the xenon
dual-phase dark matter detectors to simultaneously search for other rare
events.
[4]
oai:arXiv.org:1910.09988 [pdf] - 2026091
New constraint on the atmosphere of (50000) Quaoar from a stellar
occultation
Arimatsu, Ko;
Ohsawa, Ryou;
Hashimoto, George L.;
Urakawa, Seitaro;
Takahashi, Jun;
Tozuka, Miyako;
Itoh, Yoichi;
Yamashita, Misato;
Usui, Fumihiko;
Aoki, Tsutomu;
Arima, Noriaki;
Doi, Mamoru;
Ichiki, Makoto;
Ikeda, Shiro;
Ita, Yoshifusa;
Kasuga, Toshihiro;
Kobayashi, Naoto;
Kokubo, Mitsuru;
Konishi, Masahiro;
Maehara, Hiroyuki;
Matsunaga, Noriyuki;
Miyata, Takashi;
Morii, Mikio;
Morokuma, Tomoki;
Motohara, Kentaro;
Nakada, Yoshikazu;
Okumura, Shin-ichiro;
Sako, Shigeyuki;
Sarugaku, Yuki;
Sato, Mikiya;
Shigeyama, Toshikazu;
Soyano, Takao;
Takahashi, Hidenori;
Tarusawa, Ken'ichi;
Tominaga, Nozomu;
Watanabe, Jun-ichi;
Yamashita, Takuya;
Yoshikawa, Makoto
Submitted: 2019-10-22
We report observations of a stellar occultation by the classical Kuiper belt
object (50000) Quaoar occurred on 28 June 2019. A single-chord high-cadence (2
Hz) photometry dataset was obtained with the Tomo-e Gozen CMOS camera mounted
on the 1.05 m Schmidt telescope at Kiso Observatory. The obtained ingress and
egress data do not show any indication of atmospheric refraction and allow to
set new $1\sigma$ and $3\sigma$ upper limits of 6 and 16 nbar, respectively,
for the surface pressure of a pure methane atmosphere. These upper limits are
lower than the saturation vapor pressure of methane at Quaoar's expected mean
surface temperature ($T \sim 44$ K) and imply the absence of a $\sim$10
nbar-level global atmosphere formed by methane ice on Quaoar's surface.
[5]
oai:arXiv.org:1809.05358 [pdf] - 1851548
Search for WIMP-$^{129}$Xe inelastic scattering with particle
identification in XMASS-I
XMASS Collaboration;
Suzuki, T.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-09-14, last modified: 2019-03-19
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with
the single-phase liquid-xenon detector XMASS through inelastic scattering in
which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times
800.0 \; days$) 48 times larger than that of our previous study. The inelastic
excitation sensitivity was improved by detailed evaluation of background, event
classification based on scintillation timing that distinguished $\gamma$-rays
and $\beta$-rays, and simultaneous fitting of the energy spectra of
$\gamma$-like and $\beta$-like samples. No evidence of a WIMP signal was found.
Thus, we set the upper limits of the inelastic channel cross section at 90\%
confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\;
{\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD
WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm
GeV}/c^2$ than the existing experimental limit.
[6]
oai:arXiv.org:1808.03617 [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I
detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct
detection of dark matter. To achieve the low background requirements necessary
in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a
hexagonal window was developed based on the R8778 PMT used in the XMASS
prototype detector. We screened the numerous component materials for their
radioactivity. During development, the largest contributions to the reduction
of radioactivity came from the stem and the dynode support. The glass stem was
exchanged to the Kovar alloy one and the ceramic support were changed to the
quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted
these materials for low background purposes and provided a groundbreaking step
for further reductions of radioactivity in PMTs. Measurements with germanium
detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of
$^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of
$^{60}$Co. In this paper, the radioactive details of the developed R10789 are
described together with our screening methods and the components of the PMT.
[7]
oai:arXiv.org:1804.02180 [pdf] - 1806000
A direct dark matter search in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon
detector was conducted at the Kamioka Observatory in Japan, particularly for
Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of
data in a fiducial volume containing 97 kg of liquid xenon at the center of the
detector. The event rate in the fiducial volume after the data reduction was
${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm
5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining
events are consistent with our background evaluation, mostly of the
"mis-reconstructed events" originated from $^{210}$Pb in the copper plates
lining the detector's inner surface. The obtained upper limit on a
spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \,
cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence
level, which was the most stringent limit among results from single-phase
liquid xenon detectors.
[8]
oai:arXiv.org:1808.06177 [pdf] - 1901740
Search for sub-GeV dark matter by annual modulation using XMASS-I
detector
Kobayashi, M.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-08-19, last modified: 2018-12-22
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV)
was conducted by looking for an annual modulation signal in XMASS, a
single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by
bremsstrahlung emission was used to search down to an electron equivalent
energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in
calendar time), resulting in a total exposure of 2.38 ton-years. No significant
modulation signal was observed and 90% confidence level upper limits of $1.6
\times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section.
This is the first experimental result of a search for DM mediated by the
bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV
region (4-20 GeV) was conducted with a lower energy threshold than previous
analysis of XMASS. Elastic nuclear scattering was used to search down to a
nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9
$\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
[9]
oai:arXiv.org:1807.08516 [pdf] - 1786927
Search for dark matter in the form of hidden photons and axion-like
particles in the XMASS detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-07-23, last modified: 2018-11-18
Hidden photons and axion-like particles are candidates for cold dark matter
if they were produced non-thermally in the early universe. We conducted a
search for both of these bosons using 800 live-days of data from the XMASS
detector with 327 kg of liquid xenon in the fiducial volume. No significant
signal was observed, and thus we set constraints on the $\alpha' / \alpha$
parameter related to kinetic mixing of hidden photons and the coupling constant
$g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$,
resulting in $\alpha' / \alpha < 6 \times 10^{-26}$ and $g_{Ae} < 4 \times
10^{-13}$. These limits are the most stringent derived from both direct and
indirect searches to date.
[10]
oai:arXiv.org:1801.10096 [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I
data
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be
one of the strongest indications of the direct detection of dark matter. In
2016, we reported a search for dark matter by looking for this annual
modulation with our single-phase liquid xenon XMASS-I detector. That analysis
resulted in a slightly negative modulation amplitude at low energy. In this
work, we included more than one year of additional data, which more than
doubles the exposure to 800 live days with the same 832 kg target mass. When we
assume weakly interacting massive particle (WIMP) dark matter elastically
scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon
cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8
GeV/c$^2$ at 90\% confidence level with our newly implemented data selection
through a likelihood method. For the model-independent case, without assuming
any specific dark matter model, we obtained more consistency with the null
hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy
region. This search probed this region with an exposure that was larger than
that of DAMA/LIBRA. We also did not find any significant amplitude in the data
for periodicity with periods between 50 and 600 days in the energy region
between 1 to 6 keV.
[11]
oai:arXiv.org:1707.08995 [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the
XMASS-I detector
XMASS Collaboration;
Oka, N.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional
spacetime, axions could propagate in such extra dimensions, and acquire
Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and
could solve unexplained heating of the solar corona. While most of the solar KK
axions escape from the solar system, a small fraction is gravitationally
trapped in orbits around the Sun. They would decay into two photons inside a
terrestrial detector. The event rate is expected to modulate annually depending
on the distance from the Sun. We have searched for the annual modulation
signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant
event rate modulation is found, and hence we set the first experimental
constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\,
\mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of
$\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number
of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$
that axions can propagate in.
[12]
oai:arXiv.org:1604.01503 [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy
gamma-rays in liquid xenon with the XMASS-I detector
XMASS Collaboration;
Takiya, H.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masuda, K.;
Fushimi, K.;
Martens, K.;
Suzuki, Y.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Onishi, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Nishijima, K.;
Nakamura, S.
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from
gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation
detector. Decay time constant was derived from a comparison of scintillation
photon timing distributions between the observed data and simulated samples in
order to take into account optical processes such as absorption and scattering
in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe,
$^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming
two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$
increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9
keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all
energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to
reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast
decay component were studied as a function of the kinetic energy of electrons
induced by gamma-rays. The obtained data almost reproduced previously reported
results and extended them to the lower energy region relevant to direct dark
matter searches.
[13]
oai:arXiv.org:1511.04807 [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Tasaka, S.;
Fushimi, K.;
Liu, J.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Onishi, Y.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masada, K.;
Takiya, H.;
Nishijima, K.;
Nakamura, S.
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation
signal due to the Earth's rotation around the Sun using XMASS, a single phase
liquid xenon detector. The data used for this analysis was 359.2 live days
times 832 kg of exposure accumulated between November 2013 and March 2015. When
we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically
scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon
cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we
exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range
at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without
assuming any specific dark matter model but including electron/$\gamma$ events,
showed a slight negative amplitude. The $p$-values obtained with two
independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we
obtained 90\% C.L. upper bounds that can be used to test various models. This
is the first extensive annual modulation search probing this region with an
exposure comparable to DAMA/LIBRA.
[14]
oai:arXiv.org:1603.02904 [pdf] - 1447692
Using 220Rn to calibrate liquid noble gas detectors
Submitted: 2016-03-07
In this paper, we describe 220Rn calibration source that was developed for
liquid noble gas detectors. The key advantage of this source is that it can
provide 212Bi-212Po consecutive events, which enables us to evaluate the vertex
resolution of a detector at low energy by comparing low-energy events of 212Bi
and corresponding higher-energy alpha-rays from 212Po. Since 220Rn is a noble
gas, a hot metal getter can be used when introduced using xenon as the carrier
gas. In addition, no long-life radioactive isotopes are left behind in the
detector after the calibration is complete; this has clear advantage over the
use of 222Rn which leaves long- life radioactivity, i.e., 210Pb. Using a small
liquid xenon test chamber, we developed a system to introduce 220Rn via the
xenon carrier gas; we demonstrated the successful introduction of 6 times 10^2
220Rn atoms in our test environment.
[15]
oai:arXiv.org:1511.07597 [pdf] - 1689089
Direct Dark Matter Search with XMASS-I
Submitted: 2015-11-24
XMASS-I uses single phase liquid xenon technology for aiming at the direct
detection of dark matter. The detector observes only scintillation light by 2
inch 642 PMTs which are placed in sphere shape around an active volume. With
its large mass target and high photoelectron yield, we conducted a search for
dark matter by annual modulation with 832 kg $\times$ 359.2 days exposure of
data. We find no modulation signal in the data so that we set an upper limit
4.3$\times10^{-41} \rm{cm}^{2} $ at WIMP mass of 8 GeV/$c^{2}$ which excluded
an interpreted DAMA/LIBRA allowed region.
[16]
oai:arXiv.org:1406.0502 [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles
with the XMASS-I detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Ichimura, K.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[17]
oai:arXiv.org:1401.4737 [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from
the XMASS-I experiment
Uchida, H.;
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
[18]
oai:arXiv.org:1212.6153 [pdf] - 753387
Search for solar axions in XMASS, a large liquid-xenon detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-12-26, last modified: 2013-05-29
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date.
[19]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[20]
oai:arXiv.org:1211.5404 [pdf] - 620998
Light WIMP search in XMASS
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-11-22, last modified: 2013-01-16
A search for light dark matter using low-threshold data from the single phase
liquid xenon scintillation detector XMASS, has been conducted. Using the entire
835 kg inner volume as target, the analysis threshold can be lowered to 0.3
keVee (electron-equivalent) to search for light dark matter. With low-threshold
data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and
without discriminating between nuclear-recoil and electronic events, XMASS
excludes part of the parameter space favored by other experiments.
[21]
oai:arXiv.org:1301.2815 [pdf] - 831840
XMASS detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Nishiie, H.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Nishitani, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2013-01-13
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar
neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon.
The first phase of the XMASS experiment searches for dark matter. In this
paper, we describe the XMASS detector in detail, including its configuration,
data acquisition equipment and calibration system.
[22]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[23]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[24]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[25]
oai:arXiv.org:0810.0274 [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon
Nuclear Recoils Below 10 keV
Aprile, E.;
Baudis, L.;
Choi, B.;
Giboni, K. L.;
Lim, K. E.;
Manalaysay, A.;
Monzani, M. E.;
Plante, G.;
Santorelli, R.;
Yamashita, M.
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter
experiments, which search for low-energy nuclear recoils produced by the
elastic scattering of WIMPs with quarks. The two existing measurements of the
relative scintillation efficiency of nuclear recoils below 20 keV lead to
inconsistent extrapolations at lower energies. This results in a different
energy scale and thus sensitivity reach of liquid xenon dark matter detectors.
We report a new measurement of the relative scintillation efficiency below 10
keV performed with a liquid xenon scintillation detector, optimized for maximum
light collection. Greater than 95% of the interior surface of this detector was
instrumented with photomultiplier tubes, giving a scintillation yield of 19.6
photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the
relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying
constant around this value up to 10 keV. For higher energy recoils we measure a
value around 20%, consistent with previously reported data. In light of this
new measurement, the XENON10 experiment's results on spin-independent
WIMP-nucleon cross section, which were calculated assuming a constant 0.19
relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to
$9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from
$4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30
GeV/c$^2$.
[26]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[27]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[28]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[29]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[30]
oai:arXiv.org:0704.1118 [pdf] - 231
Observation of Anti-correlation between Scintillation and Ionization for
MeV Gamma-Rays in Liquid Xenon
Submitted: 2007-04-09
A strong anti-correlation between ionization and scintillation signals
produced by MeV gamma-rays in liquid xenon has been measured and used to
improve the energy resolution by combining the two signals. The improvement is
explained by reduced electron-ion recombination fluctuations of the combined
signal compared to fluctuations of the individual signals. Simultaneous
measurements of ionization and scintillation signals were carried out with
Cs-137, Na-22 and Co-60 gamma rays, as a function of electric field in the
liquid. A resolution of 1.7%(sigma) at 662 keV was measured at 1 kV/cm,
significantly better than the resolution from either scintillation or
ionization alone. A detailed analysis indicates that further improvement to
less than 1%(sigma) is possible with higher light collection efficiency and
lower electronic noise.
[31]
oai:arXiv.org:astro-ph/0609714 [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Coelho, L.;
Dahl, E.;
DeViveiros, L.;
Ferella, A.;
Fernandes, L.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. -L.;
Gomez, R.;
Hasty, R.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santos, J.;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Winant, C.;
Yamashita, M.
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time
projection chamber (XeTPC) for dark matter search is described. Results from a
prototype detector (XENON3) are presented.
[32]
oai:arXiv.org:physics/0608034 [pdf] - 119179
Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Submitted: 2006-08-03, last modified: 2006-08-04
Scintillation light from gamma ray irradiation in liquid xenon is detected by
two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV
light reflector material, PTFE, is used to optimize the light collection
efficiency. The detector gives a high light yield of 6 photoelectron per keV
(pe/keV), which allows efficient detection of the 122 keV gamma-ray line from
Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best
achievable energy resolution, by removing the instrumental fluctuations, from
liquid xenon scintillation light is estimated to be around 6-8% (sigma) for
gamma-ray with energy between 662 keV and 122 keV.
[33]
oai:arXiv.org:astro-ph/0601552 [pdf] - 79410
Simultaneous Measurement of Ionization and Scintillation from Nuclear
Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Aprile, E.;
Dahl, C. E.;
DeViveiros, L.;
Gaitskell, R.;
Giboni, K. L.;
Kwong, J.;
Majewski, P.;
Ni, K.;
Shutt, T.;
Yamashita, M.
Submitted: 2006-01-24
We report the first measurements of the absolute ionization yield of nuclear
recoils in liquid xenon, as a function of energy and electric-field.
Independent experiments were carried out with two dual-phase time projection
chamber prototypes, developed for the XENON Dark Matter project. We find that
the charge yield increases with decreasing recoil energy, and exhibits only a
weak field dependence. These results are a first demonstration of the
capability of dual phase xenon detectors to discriminate between electron and
nuclear recoils, a key requirement for a sensitive dark matter search at recoil
energies down to 20 keV.
[34]
oai:arXiv.org:astro-ph/0503621 [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium
to search for dark matter in the form of Weakly Interacting Massive Particles
(WIMPs). Knowledge of LXe ionization and scintillation response to low energy
nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important
for determining the sensitivity of LXe direct detection experiments. Here we
report on new measurements of the scintillation yield of Xe recoils with
kinetic energy as low as 10 keV. The dependence of the scintillation yield on
applied electric field was also measured in the range of 0 to 4 kV/cm. Results
are in good agreement with recent theoretical predictions that take into
account the effect of biexcitonic collisions in addition to the nuclear
quenching effect.
[35]
oai:arXiv.org:physics/0502071 [pdf] - 119079
Performance of a Large Area Avalanche Photodiode in a Liquid Xenon
Ionization and Scintillation Chamber
Submitted: 2005-02-14
Scintillation light produced in liquid xenon (LXe) by alpha particles,
electrons and gamma-rays was detected with a large area avalanche photodiode
(LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a
function of applied electric field. We estimate the quantum efficiency of the
LAAPD to be 45%. The best energy resolution from the light measurement at zero
electric field is 7.5%(sigma) for 976 keV internal conversion electrons from
Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector
used for these measurements was also operated as a gridded ionization chamber
to measure the charge yield. We confirm that using a LAAPD in LXe does not
introduce impurities which inhibit the drifting of free electrons.
[36]
oai:arXiv.org:astro-ph/0407575 [pdf] - 66417
The XENON Dark Matter Search Experiment
Aprile, E.;
Giboni, K. L.;
Majewski, P.;
Ni, K.;
Yamashita, M.;
Gaitskell, R.;
Sorensen, P.;
DeViveiros, L.;
Baudis, L.;
Bernstein, A.;
Hagmann, C.;
Winant, C.;
Shutt, T.;
Kwong, J.;
Oberlack, U.;
McKinsey, D.;
Hasty, R.
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form
of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering
off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent
liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest
interaction cross section predicted by SUSY models. The TPCs are operated in
dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to
16keV energy, via simultaneous detection of the ionization, through secondary
scintillation in the gas, and primary scintillation in the liquid. Thedistinct
ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or
neutrons), and for electron recoils from background, iskey to the
event-by-event discrimination capability of XENON. A dual phase xenon prototype
has been realized and is currently being tested, along with otherprototypes
dedicated to other measurements relevant to the XENON program. As part of the
R&D phase, we will realize and move underground a first XENON module (XENON10)
with at least 10 kg fiducial mass to measure the background rejection
capability and to optimize the conditions for continuous and stable detector
operation underground. We present some of the results from the ongoing R&D and
summarize the expected performance of the 10 kg experiment, from MonteCarlo
simulations. The main design features of the 100 kg detector unit(XENON100),
with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will
also be presented.