Normalized to: Matsuura, D.
[1]
oai:arXiv.org:1509.00588 [pdf] - 1270723
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray
Detector (SGD)
Watanabe, Shin;
Tajima, Hiroyasu;
Fukazawa, Yasushi;
Ichinohe, Yuto;
Takeda, Shin'ichiro;
Enoto, Teruaki;
Fukuyama, Taro;
Furui, Shunya;
Genba, Kei;
Hagino, Kouichi;
Harayama, Astushi;
Kuroda, Yoshikatsu;
Matsuura, Daisuke;
Nakamura, Ryo;
Nakazawa, Kazuhiro;
Noda, Hirofumi;
Odaka, Hirokazu;
Ohta, Masayuki;
Onishi, Mitsunobu;
Saito, Shinya;
Sato, Goro;
Sato, Tamotsu;
Takahashi, Tadayuki;
Tanaka, Takaaki;
Togo, Atsushi;
Tomizuka, Shinji
Submitted: 2015-09-02
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard
ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level
10 times better than instruments currently in orbit. The SGD achieves low
background by combining a Compton camera scheme with a narrow field-of-view
active shield. The Compton camera in the SGD is realized as a hybrid
semiconductor detector system which consists of silicon and cadmium telluride
(CdTe) sensors. The design of the SGD Compton camera has been finalized and the
final prototype, which has the same configuration as the flight model, has been
fabricated for performance evaluation. The Compton camera has overall
dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel
sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel
sensors. The detection efficiency of the Compton camera reaches about 15% and
3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si
and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed
by 208 ASICs developed for the SGD. Good energy resolution is afforded by
semiconductor sensors and low noise ASICs, and the obtained energy resolutions
with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV
and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good
background rejection capability due to better constraints on Compton
kinematics. Compton camera energy resolutions achieved with the final prototype
are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively,
which satisfy the instrument requirements for the SGD Compton camera (better
than 2%). Moreover, a low intrinsic background has been confirmed by the
background measurement with the final prototype.
[2]
oai:arXiv.org:1102.2472 [pdf] - 317830
Development of the analog ASIC for multi-channel readout X-ray CCD
camera
Nakajima, Hiroshi;
Matsuura, Daisuke;
Idehara, Toshihiro;
Anabuki, Naohisa;
Tsunemi, Hiroshi;
Doty, John P.;
Ikeda, Hirokazu;
Katayama, Haruyoshi;
Kitamura, Hisashi;
Uchihori, Yukio
Submitted: 2011-02-11
We report on the performance of an analog application-specific integrated
circuit (ASIC) developed aiming for the front-end electronics of the X-ray
CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has
four identical channels that simultaneously process the CCD signals.
Distinctive capability of analog-to-digital conversion enables us to construct
a CCD camera body that outputs only digital signals. As the result of the
front-end electronics test, it works properly with low input noise of =<30 uV
at the pixel rate below 100 kHz. The power consumption is sufficiently low of
about 150 mW/chip. The input signal range of 720 mV covers the effective energy
range of the typical X-ray photon counting CCD (up to 20 keV). The integrated
non-linearity is 0.2% that is similar as those of the conventional CCDs in
orbit. We also performed a radiation tolerance test against the total ionizing
dose (TID) effect and the single event effect. The irradiation test using 60Co
and proton beam showed that the ASIC has the sufficient tolerance against TID
up to 200 krad, which absolutely exceeds the expected amount of dose during the
period of operating in a low-inclination low-earth orbit. The irradiation of Fe
ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup
(SEL), although there were some possible single event upsets. The threshold
against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough
that the SEL event should not be one of major causes of instrument downtime in
orbit.
[3]
oai:arXiv.org:0710.0785 [pdf] - 5637
Development of an n-channel CCD, CCD-NeXT1, for Soft X-ray Imager
onboard the NeXT satellite
Takagi, Shin-ichiro;
Tsuru, Takeshi Go;
Inui, Tatsuya;
Matsumoto, Hironori;
Koyama, Katsuji;
Ozawa, Hideki;
Tohiguchi, Masakuni;
Matsuura, Daisuke;
Miyata, Emi;
Tsunemi, Hiroshi;
Miyaguchi, Kazuhisa;
Maeda, Kentaro;
Kohno, Hirohiko
Submitted: 2007-10-03
NeXT (New X-ray Telescope) is the next Japanese X-ray astronomical satellite
mission after the Suzaku satellite. NeXT aims to perform wide band imaging
spectroscopy. Due to the successful development of a multilayer coated mirror,
called a supermirror, NeXT can focus X-rays in the energy range from 0.1 keV up
to 80 keV. To cover this wide energy range, we are in the process of developing
a hybrid X-ray camera, Wideband X-ray Imager (WXI) as a focal plane detector of
the supermirror. The WXI consists of X-ray CCDs (SXI) and CdTe pixelized
detectors (HXI), which cover the lower and higher X-ray energy bands of 0.1-80
keV, respectively. The X-ray CCDs of the SXI are stacked above the CdTe
pixelized detectors of the HXI. The X-ray CCDs of the SXI detect soft X-rays
below $\sim$ 10 keV and allow hard X-rays pass into the CdTe detectors of the
HXI without loss. Thus, we have been developing a "back-supportless CCD" with a
thick depletion layer, a thinned silicon wafer, and a back-supportless
structure. In this paper, we report the development and performances of an
evaluation model of CCD for the SXI, "CCD-NeXT1". We successfully fabricated
two types of CCD-NeXT1, unthinned CCDs with 625-um thick wafer and 150-um thick
thinned CCDs. By omitting the polishing process when making the thinned CCDs,
we confirmed that the polishing process does not impact the X-ray performance.
In addition, we did not find significant differences in the X-ray performance
between the two types of CCDs. The energy resolution and readout noise are
$\sim$ 140 eV (FWHM) at 5.9 keV and $\sim$5 electrons (RMS), respectively. The
estimated thickness of the depletion layer is $\sim$80 um. The performances
almost satisfy the requirements of the baseline plan of the SXI.
[4]
oai:arXiv.org:0708.3968 [pdf] - 1530002
Spectral evolution of GRB 060904A observed with Swift and Suzaku --
Possibility of Inefficient Electron Acceleration
Yonetoku, Daisuke;
Tanabe, Sachiko;
Murakami, Toshio;
Emura, Naomi;
Aoyama, Yuka;
Kidamura, Takashi;
Kodaira, Hironobu;
Kodama, Yoshiki;
Kozaka, Ryota;
Nashimoto, Takuro;
Okuno, Shinya;
Yokota, Satoshi;
Yoshinari, Satoru;
Abe, Keiichi;
Onda, Kaori;
Tashiro, Makoto S.;
Urata, Yuji;
Nakagawa, Yujin E.;
Sugita, Satoshi;
Yamaoka, Kazutaka;
Yoshida, Atsumasa;
Ishimura, Takuto;
Kawai, Nobuyuki;
Shimokawabe, Takashi;
Kinugasa, Kenzo;
Kohmura, Takayoshi;
Kubota, Kaori;
Sugiyasu, Kei;
Ueda, Yoshihiro;
Masui, Kensuke;
Nakazawa, Kazuhiro;
Takahashi, Tadayuki;
Maeno, Shouta;
Sonoda, Eri;
Yamauchi, Makoto;
Kuwahara, Makoto;
Tamagawa, Toru;
Matsuura, Daisuke;
Suzuki, Motoko;
Barthelmy, Scott;
Gehrels, Neil;
Nousek, John
Submitted: 2007-08-29
We observed an X-ray afterglow of GRB 060904A with the Swift and Suzaku
satellites. We found rapid spectral softening during both the prompt tail phase
and the decline phase of an X-ray flare in the BAT and XRT data. The observed
spectra were fit by power-law photon indices which rapidly changed from $\Gamma
= 1.51^{+0.04}_{-0.03}$ to $\Gamma = 5.30^{+0.69}_{-0.59}$ within a few hundred
seconds in the prompt tail. This is one of the steepest X-ray spectra ever
observed, making it quite difficult to explain by simple electron acceleration
and synchrotron radiation. Then, we applied an alternative spectral fitting
using a broken power-law with exponential cutoff (BPEC) model. It is valid to
consider the situation that the cutoff energy is equivalent to the synchrotron
frequency of the maximum energy electrons in their energy distribution. Since
the spectral cutoff appears in the soft X-ray band, we conclude the electron
acceleration has been inefficient in the internal shocks of GRB 060904A. These
cutoff spectra suddenly disappeared at the transition time from the prompt tail
phase to the shallow decay one. After that, typical afterglow spectra with the
photon indices of 2.0 are continuously and preciously monitored by both XRT and
Suzaku/XIS up to 1 day since the burst trigger time. We could successfully
trace the temporal history of two characteristic break energies (peak energy
and cutoff energy) and they show the time dependence of $\propto t^{-3} \sim
t^{-4}$ while the following afterglow spectra are quite stable. This fact
indicates that the emitting material of prompt tail is due to completely
different dynamics from the shallow decay component. Therefore we conclude the
emission sites of two distinct phenomena obviously differ from each other.
[5]
oai:arXiv.org:0705.1771 [pdf] - 1529986
Performance of the Charge Injection Capability of Suzaku XIS
Nakajima, H.;
Yamaguchi, H.;
Matsumoto, H.;
Tsuru, T. G.;
Koyama, K.;
Tsunemi, H.;
Hayashida, K.;
Torii, K.;
Namiki, M.;
Katsuda, S.;
Shoji, M.;
Matsuura, D.;
Miyauchi, T.;
Dotani, T.;
Ozaki, M.;
Murakami, H.;
Bautz, M. W.;
Kissel, S. E.;
LaMarr, B.;
Prigozhin, G. Y.
Submitted: 2007-05-12
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray
Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in
each CCD column (vertical transfer channel) is measured by the injection of
charge packets into a transfer channel and subsequent readout. This paper
reports the performances of the charge injection capability based on the ground
experiments using a radiation damaged device, and in-orbit measurements of the
XIS. The ground experiments show that charges are stably injected with the
dispersion of 91eV in FWHM in a specific column for the charges equivalent to
the X-ray energy of 5.1keV. This dispersion width is significantly smaller than
that of the X-ray events of 113eV (FWHM) at approximately the same energy. The
amount of charge loss during transfer in a specific column, which is measured
with the charge injection capability, is consistent with that measured with the
calibration source. These results indicate that the charge injection technique
can accurately measure column-dependent charge losses rather than the
calibration sources. The column-to-column CTI correction to the calibration
source spectra significantly reduces the line widths compared to those with a
column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at
the time of one year after the launch). In addition, this method significantly
reduces the low energy tail in the line profile of the calibration source
spectrum.