Normalized to: Yurduseven, O.
[1]
oai:arXiv.org:2001.05151 [pdf] - 2050374
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated
Superconducting Spectrometer
Takekoshi, Tatsuya;
Karatsu, Kenichi;
Suzuki, Junya;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Baselmans, Jochem J. A.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Endo, Akira
Submitted: 2020-01-15
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep
Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip
filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate
dusty star-burst galaxies in the distant universe at millimeter and
submillimeter wavelength. An on-site experiment of DESHIMA was performed using
the ASTE 10-m telescope. We established a responsivity model that converts
frequency responses of the MKIDs to line-of-sight brightness temperature. We
estimated two parameters of the responsivity model using a set of skydip data
taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for
each MKID. The line-of-sight brightness temperature of sky is estimated using
an atmospheric transmission model and the PWVs. As a result, we obtain an
average temperature calibration uncertainty of $1\sigma=4$%, which is smaller
than other photometric biases. In addition, the average forward efficiency of
0.88 in our responsivity model is consistent with the value expected from the
geometrical support structure of the telescope. We also estimate line-of-sight
PWVs of each skydip observation using the frequency response of MKIDs, and
confirm the consistency with PWVs reported by the Atacama Large
Millimeter/submillimeter Array.
[2]
oai:arXiv.org:1906.10216 [pdf] - 1963690
First light demonstration of the integrated superconducting spectrometer
Endo, Akira;
Karatsu, Kenichi;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Takekoshi, Tatsuya;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Junya;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2019-06-24, last modified: 2019-09-18
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter
(mm-submm) band is an essential tool for uncovering the dust-enshrouded portion
of the cosmic history of star formation and galaxy evolution. However, it is
challenging to scale up conventional coherent heterodyne receivers or
free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and
numbers of spatial pixels (>$10^2$). Here we present the design and first
astronomical spectra of an intrinsically scalable, integrated superconducting
spectrometer, which covers 332-377 GHz with a spectral resolution of $F/\Delta
F \sim 380$. It combines the multiplexing advantage of microwave kinetic
inductance detectors (MKIDs) with planar superconducting filters for dispersing
the signal in a single, small superconducting integrated circuit. We
demonstrate the two key applications for an instrument of this type: as an
efficient redshift machine, and as a fast multi-line spectral mapper of
extended areas. The line detection sensitivity is in excellent agreement with
the instrument design and laboratory performance, reaching the atmospheric
foreground photon noise limit on sky. The design can be scaled to bandwidths in
excess of an octave, spectral resolution up to a few thousand and frequencies
up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$
allows for compact multi-pixel spectral imagers, which would enable
spectroscopic direct imaging and large volume spectroscopic surveys that are
several orders of magnitude faster than what is currently possible.
[3]
oai:arXiv.org:1901.06934 [pdf] - 1904696
Wideband on-chip terahertz spectrometer based on a superconducting
filterbank
Endo, Akira;
Karatsu, Kenichi;
Laguna, Alejandro Pascual;
Mirzaei, Behnam;
Huiting, Robert;
Thoen, David J.;
Murugesan, Vignesh;
Yates, Stephen J. C.;
Bueno, Juan;
van Marrewijk, Nuri;
Bosma, Sjoerd;
Yurduseven, Ozan;
Llombart, Nuria;
Suzuki, Junya;
Naruse, Masato;
de Visser, Pieter J.;
van der Werf, Paul P.;
Klapwijk, Teun M.;
Baselmans, Jochem J. A.
Submitted: 2019-01-21, last modified: 2019-06-21
Terahertz spectrometers with a wide instantaneous frequency coverage for
passive remote sensing are enormously attractive for many terahertz
applications, such as astronomy, atmospheric science and security. Here we
demonstrate a wide-band terahertz spectrometer based on a single
superconducting chip. The chip consists of an antenna coupled to a transmission
line filterbank, with a microwave kinetic inductance detector behind each
filter. Using frequency division multiplexing, all detectors are read-out
simultaneously creating a wide-band spectrometer with an instantaneous
bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral
resolution of $F/\Delta F=380$ and reaches photon-noise limited sensitivity. We
discuss the chip design and fabrication, as well as the system integration and
testing. We confirm full system operation by the detection of an emission line
spectrum of methanol gas. The proposed concept allows for spectroscopic
radiation detection over large bandwidths and resolutions up to $F/\Delta
F\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the
construction of medium resolution imaging spectrometers with unprecedented
speed and sensitivity.
[4]
oai:arXiv.org:1809.04452 [pdf] - 1749362
Eliminating stray radiation inside large area imaging arrays
Yates, Stephen J. C.;
Doyle, Simon;
Barry, Peter;
Baryshev, Andrey M.;
Bueno, Juan;
Ferrari, Lorenza;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2018-09-11
With increasing array size, it is increasingly important to control stray
radiation inside the detector chips themselves. We demonstrate this effect with
focal plane arrays of absorber coupled Lumped Element microwave Kinetic
Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter
wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the
response from a point source at the pixel position is at a similar level to the
stray response integrated over the entire chip area. For the antenna coupled
arrays, we show that this effect can be suppressed by incorporating an on-chip
stray light absorber. A similar method should be possible with the LEKID array,
especially when they are lens coupled.
[5]
oai:arXiv.org:1707.02142 [pdf] - 1585646
Surface wave control for large arrays of microwave kinetic inductance
detectors
Yates, Stephen J. C.;
Baryshev, Andrey M.;
Yurduseven, Ozan;
Bueno, Juan;
Davis, Kristina K.;
Ferrari, Lorenza;
Jellema, Willem;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Baselmans, Jochem J. A.
Submitted: 2017-07-07
Large ultra-sensitive detector arrays are needed for present and future
observatories for far infra-red, submillimeter wave (THz), and millimeter wave
astronomy. With increasing array size, it is increasingly important to control
stray radiation inside the detector chips themselves, the surface wave. We
demonstrate this effect with focal plane arrays of 880 lens-antenna coupled
Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field
measurements of the MKID optical response versus the position on the array of a
reimaged optical source. We demonstrate that the optical response of a detector
in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the
peak pixel response. The result is that the power detected from a point source
at the pixel position is almost identical to the stray response integrated over
the chip area. With such a contribution, it would be impossible to measure
extended sources, while the point source sensitivity is degraded due to an
increase of the stray loading. However, we show that by incorporating an
on-chip stray light absorber, the surface wave contribution is reduced by a
factor $>$10. With the on-chip stray light absorber the point source response
is close to simulations down to the $\sim-35$ dB level, the simulation based on
an ideal Gaussian illumination of the optics. In addition, as a crosscheck we
show that the extended source response of a single pixel in the array with the
absorbing grid is in agreement with the integral of the point source
measurements.
[6]
oai:arXiv.org:1609.01952 [pdf] - 1574543
A kilo-pixel imaging system for future space based far-infrared
observatories using microwave kinetic inductance detectors
Baselmans, J. J. A.;
Bueno, J.;
Yates, S. J. C.;
Yurduseven, O.;
Llombart, N.;
Karatsu, K.;
Baryshev, A. M.;
Ferrari, L.;
Endo, A.;
Thoen, D. J.;
de Visser, P. J.;
Janssen, R. M. J.;
Murugesan, V.;
Driessen, E. F. C.;
Coiffard, G.;
Martin-Pintado, J.;
Hargrave, P.;
Griffin, M.
Submitted: 2016-09-07, last modified: 2017-03-01
Future astrophysics and cosmic microwave background space missions operating
in the far-infrared to millimetre part of the spectrum will require very large
arrays of ultra-sensitive detectors in combination with high multiplexing
factors and efficient low-noise and low-power readout systems. We have
developed a demonstrator system suitable for such applications. The system
combines a 961 pixel imaging array based upon Microwave Kinetic Inductance
Detectors (MKIDs) with a readout system capable of reading out all pixels
simultaneously with only one readout cable pair and a single cryogenic
amplifier. We evaluate, in a representative environment, the system performance
in terms of sensitivity, dynamic range, optical efficiency, cosmic ray
rejection, pixel-pixel crosstalk and overall yield at at an observation centre
frequency of 850 GHz and 20% fractional bandwidth. The overall system has an
excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19
W/rt(Hz) measured using a thermal calibration source. At a loading power per
pixel of 50fW we demonstrate white, photon noise limited detector noise down to
300 mHz. The dynamic range would allow the detection of 1 Jy bright sources
within the field of view without tuning the readout of the detectors. The
expected dead time due to cosmic ray interactions, when operated in an L2 or a
similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel
yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates
that MKID technology can provide multiplexing ratios on the order of a 1000
with state-of-the-art single pixel performance, and that the technology is now
mature enough to be considered for future space based observatories and
experiments.