Normalized to: Yates, S.
[1]
oai:arXiv.org:2002.03790 [pdf] - 2045588
Complex beam mapping and Fourier optics analysis of a wide field
Microwave Kinetic Inductance Detector camera
Submitted: 2020-02-10
For astronomical instruments, accurate knowledge of the optical pointing and
coupling are essential to characterize the alignment and performance of
(sub-)systems prior to integration and deployment. Ideally, this requires the
phase response of the optical system, which for direct (phase insensitive)
detectors was not previously accessible. Here we show development of the phase
sensitive complex beam pattern technique using a dual optical source heterodyne
technique for a large field of view Microwave Kinetic Inductance Detector
camera at 350 GHz. We show here how you can analyze the measured data with
Fourier optics, which allows integration into a telescope model to calculate
the on sky beam pattern and telescope aperture efficiency prior to deployment
at a telescope.
[2]
oai:arXiv.org:2001.05151 [pdf] - 2050374
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated
Superconducting Spectrometer
Takekoshi, Tatsuya;
Karatsu, Kenichi;
Suzuki, Junya;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Baselmans, Jochem J. A.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Endo, Akira
Submitted: 2020-01-15
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep
Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip
filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate
dusty star-burst galaxies in the distant universe at millimeter and
submillimeter wavelength. An on-site experiment of DESHIMA was performed using
the ASTE 10-m telescope. We established a responsivity model that converts
frequency responses of the MKIDs to line-of-sight brightness temperature. We
estimated two parameters of the responsivity model using a set of skydip data
taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for
each MKID. The line-of-sight brightness temperature of sky is estimated using
an atmospheric transmission model and the PWVs. As a result, we obtain an
average temperature calibration uncertainty of $1\sigma=4$%, which is smaller
than other photometric biases. In addition, the average forward efficiency of
0.88 in our responsivity model is consistent with the value expected from the
geometrical support structure of the telescope. We also estimate line-of-sight
PWVs of each skydip observation using the frequency response of MKIDs, and
confirm the consistency with PWVs reported by the Atacama Large
Millimeter/submillimeter Array.
[3]
oai:arXiv.org:1906.10216 [pdf] - 1963690
First light demonstration of the integrated superconducting spectrometer
Endo, Akira;
Karatsu, Kenichi;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Takekoshi, Tatsuya;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Junya;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2019-06-24, last modified: 2019-09-18
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter
(mm-submm) band is an essential tool for uncovering the dust-enshrouded portion
of the cosmic history of star formation and galaxy evolution. However, it is
challenging to scale up conventional coherent heterodyne receivers or
free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and
numbers of spatial pixels (>$10^2$). Here we present the design and first
astronomical spectra of an intrinsically scalable, integrated superconducting
spectrometer, which covers 332-377 GHz with a spectral resolution of $F/\Delta
F \sim 380$. It combines the multiplexing advantage of microwave kinetic
inductance detectors (MKIDs) with planar superconducting filters for dispersing
the signal in a single, small superconducting integrated circuit. We
demonstrate the two key applications for an instrument of this type: as an
efficient redshift machine, and as a fast multi-line spectral mapper of
extended areas. The line detection sensitivity is in excellent agreement with
the instrument design and laboratory performance, reaching the atmospheric
foreground photon noise limit on sky. The design can be scaled to bandwidths in
excess of an octave, spectral resolution up to a few thousand and frequencies
up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$
allows for compact multi-pixel spectral imagers, which would enable
spectroscopic direct imaging and large volume spectroscopic surveys that are
several orders of magnitude faster than what is currently possible.
[4]
oai:arXiv.org:1901.06934 [pdf] - 1904696
Wideband on-chip terahertz spectrometer based on a superconducting
filterbank
Endo, Akira;
Karatsu, Kenichi;
Laguna, Alejandro Pascual;
Mirzaei, Behnam;
Huiting, Robert;
Thoen, David J.;
Murugesan, Vignesh;
Yates, Stephen J. C.;
Bueno, Juan;
van Marrewijk, Nuri;
Bosma, Sjoerd;
Yurduseven, Ozan;
Llombart, Nuria;
Suzuki, Junya;
Naruse, Masato;
de Visser, Pieter J.;
van der Werf, Paul P.;
Klapwijk, Teun M.;
Baselmans, Jochem J. A.
Submitted: 2019-01-21, last modified: 2019-06-21
Terahertz spectrometers with a wide instantaneous frequency coverage for
passive remote sensing are enormously attractive for many terahertz
applications, such as astronomy, atmospheric science and security. Here we
demonstrate a wide-band terahertz spectrometer based on a single
superconducting chip. The chip consists of an antenna coupled to a transmission
line filterbank, with a microwave kinetic inductance detector behind each
filter. Using frequency division multiplexing, all detectors are read-out
simultaneously creating a wide-band spectrometer with an instantaneous
bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral
resolution of $F/\Delta F=380$ and reaches photon-noise limited sensitivity. We
discuss the chip design and fabrication, as well as the system integration and
testing. We confirm full system operation by the detection of an emission line
spectrum of methanol gas. The proposed concept allows for spectroscopic
radiation detection over large bandwidths and resolutions up to $F/\Delta
F\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the
construction of medium resolution imaging spectrometers with unprecedented
speed and sensitivity.
[5]
oai:arXiv.org:1809.08341 [pdf] - 1755195
Analysis techniques for complex-field radiation pattern measurements
Submitted: 2018-09-21
Complex field measurements are increasingly becoming the standard for
state-of-the-art astronomical instrumentation. Complex field measurements have
been used to characterize a suite of ground, airborne, and space-based
heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of
how to acquire coherent field maps for direct detector arrays was demonstrated
in Davis et. al. 2017. This technique has the ability to determine both
amplitude and phase radiation patterns from individual pixels on an array.
Phase information helps to better characterize the optical performance of the
array (as compared to total power radiation patterns) by constraining the fit
in an additional plane [4].
Here we discuss the mathematical framework used in an analysis pipeline
developed to process complex field radiation pattern measurements. This routine
determines and compensates misalignments of the instrument and scanning system.
We begin with an overview of Gaussian beam formalism and how it relates to
complex field pattern measurements. Next we discuss a scan strategy using an
offset in z along the optical axis that allows first-order optical standing
waves between the scanned source and optical system to be removed in
post-processing. Also discussed is a method by which the co- and
cross-polarization fields can be extracted individually for each pixel by
rotating the two orthogonal measurement planes until the signal is the
co-polarization map is maximized (and the signal in the cross-polarization
field is minimized). We detail a minimization function that can fit measurement
data to an arbitrary beam shape model. We conclude by discussing the angular
plane wave spectral (APWS) method for beam propagation, including the
near-field to far-field transformation.
[6]
oai:arXiv.org:1809.04452 [pdf] - 1749362
Eliminating stray radiation inside large area imaging arrays
Yates, Stephen J. C.;
Doyle, Simon;
Barry, Peter;
Baryshev, Andrey M.;
Bueno, Juan;
Ferrari, Lorenza;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2018-09-11
With increasing array size, it is increasingly important to control stray
radiation inside the detector chips themselves. We demonstrate this effect with
focal plane arrays of absorber coupled Lumped Element microwave Kinetic
Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter
wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the
response from a point source at the pixel position is at a similar level to the
stray response integrated over the entire chip area. For the antenna coupled
arrays, we show that this effect can be suppressed by incorporating an on-chip
stray light absorber. A similar method should be possible with the LEKID array,
especially when they are lens coupled.
[7]
oai:arXiv.org:1707.02142 [pdf] - 1585646
Surface wave control for large arrays of microwave kinetic inductance
detectors
Yates, Stephen J. C.;
Baryshev, Andrey M.;
Yurduseven, Ozan;
Bueno, Juan;
Davis, Kristina K.;
Ferrari, Lorenza;
Jellema, Willem;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Baselmans, Jochem J. A.
Submitted: 2017-07-07
Large ultra-sensitive detector arrays are needed for present and future
observatories for far infra-red, submillimeter wave (THz), and millimeter wave
astronomy. With increasing array size, it is increasingly important to control
stray radiation inside the detector chips themselves, the surface wave. We
demonstrate this effect with focal plane arrays of 880 lens-antenna coupled
Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field
measurements of the MKID optical response versus the position on the array of a
reimaged optical source. We demonstrate that the optical response of a detector
in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the
peak pixel response. The result is that the power detected from a point source
at the pixel position is almost identical to the stray response integrated over
the chip area. With such a contribution, it would be impossible to measure
extended sources, while the point source sensitivity is degraded due to an
increase of the stray loading. However, we show that by incorporating an
on-chip stray light absorber, the surface wave contribution is reduced by a
factor $>$10. With the on-chip stray light absorber the point source response
is close to simulations down to the $\sim-35$ dB level, the simulation based on
an ideal Gaussian illumination of the optics. In addition, as a crosscheck we
show that the extended source response of a single pixel in the array with the
absorbing grid is in agreement with the integral of the point source
measurements.
[8]
oai:arXiv.org:1609.01952 [pdf] - 1574543
A kilo-pixel imaging system for future space based far-infrared
observatories using microwave kinetic inductance detectors
Baselmans, J. J. A.;
Bueno, J.;
Yates, S. J. C.;
Yurduseven, O.;
Llombart, N.;
Karatsu, K.;
Baryshev, A. M.;
Ferrari, L.;
Endo, A.;
Thoen, D. J.;
de Visser, P. J.;
Janssen, R. M. J.;
Murugesan, V.;
Driessen, E. F. C.;
Coiffard, G.;
Martin-Pintado, J.;
Hargrave, P.;
Griffin, M.
Submitted: 2016-09-07, last modified: 2017-03-01
Future astrophysics and cosmic microwave background space missions operating
in the far-infrared to millimetre part of the spectrum will require very large
arrays of ultra-sensitive detectors in combination with high multiplexing
factors and efficient low-noise and low-power readout systems. We have
developed a demonstrator system suitable for such applications. The system
combines a 961 pixel imaging array based upon Microwave Kinetic Inductance
Detectors (MKIDs) with a readout system capable of reading out all pixels
simultaneously with only one readout cable pair and a single cryogenic
amplifier. We evaluate, in a representative environment, the system performance
in terms of sensitivity, dynamic range, optical efficiency, cosmic ray
rejection, pixel-pixel crosstalk and overall yield at at an observation centre
frequency of 850 GHz and 20% fractional bandwidth. The overall system has an
excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19
W/rt(Hz) measured using a thermal calibration source. At a loading power per
pixel of 50fW we demonstrate white, photon noise limited detector noise down to
300 mHz. The dynamic range would allow the detection of 1 Jy bright sources
within the field of view without tuning the readout of the detectors. The
expected dead time due to cosmic ray interactions, when operated in an L2 or a
similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel
yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates
that MKID technology can provide multiplexing ratios on the order of a 1000
with state-of-the-art single pixel performance, and that the technology is now
mature enough to be considered for future space based observatories and
experiments.
[9]
oai:arXiv.org:1609.00163 [pdf] - 1472993
Measurements and analysis of optical crosstalk in a microwave kinetic
inductance detector array
Submitted: 2016-09-01
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is
their multiplexing capability, which allows for building cameras with a large
number of pixels and good sensitivity, particularly suitable to perform large
blank galaxy surveys. However, to have as many pixels as possible it is
necessary to arrange detectors close in readout frequency. Consequently KIDs
overlap in frequency and are coupled to each other producing crosstalk. Because
crosstalk can be only minimised by improving the array design, in this work we
aim to correct for this effect a posteriori. We analysed a MKID array
consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the
beam patterns for every detector in the array and described the response of
each detector by using a two-dimensional Gaussian fit. Then, we identified
detectors affected by crosstalk above -30 dB level from the maximum and removed
the signal of the crosstalking detectors. Moreover, we modelled the crosstalk
level for each KID as a function of the readout frequency separation starting
from the assumption that the transmission of a KID is a Lorenztian function in
power. We were able to describe the general crosstalk level of the array and
the crosstalk of each KID within 5 dB, so enabling the design of future arrays
with the crosstalk as a design criterion. In this work, we demonstrate that it
is possible to process MKID images a posteriori to decrease the crosstalk
effect, subtracting the response of each coupled KID from the original map.
[10]
oai:arXiv.org:1507.04151 [pdf] - 1384120
Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic
Inductance Detectors
Submitted: 2015-07-15, last modified: 2016-04-01
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive
radiation detectors for far-infrared and sub-mm astronomy: They combine
ultimate sensitivity with the possibility to create very large detector arrays,
in excess of 10 000 pixels. This is possible by reading-out the arrays using RF
frequency division multiplexing, which allows multiplexing ratios in excess of
1000 pixels per readout line. We describe a novel readout system for large
arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout,
which is a combination of a digital front- and back-end and an analog up- and
down-converter system, can read out up to 4000 detectors simultaneously with 1
kHz datarate. The system achieves a readout noise power spectral density of -98
dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the
number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN
MKIDs can be read out without deteriorating their intrinsic performance.
[11]
oai:arXiv.org:1602.00442 [pdf] - 1356872
Calibration scheme for large Kinetic Inductance Detector Arrays based on
Readout Frequency Response
Submitted: 2016-02-01
Microwave kinetic inductance detector (MKID) provides a way to build large
ground based sub-mm instruments such as NIKA and A-MKID. For such instruments,
therefore, it is important to understand and characterize the response to
ensure good linearity and calibration over wide dynamic range. We propose to
use the MKID readout frequency response to determine the MKID responsivity to
an input optical source power. A signal can be measured in a KID as a change in
the phase of the readout signal with respect to the KID resonant circle.
Fundamentally, this phase change is due to a shift in the KID resonance
frequency, in turn due to a radiation induced change in the quasiparticle
number in the superconducting resonator. We show that shift in resonant
frequency can be determined from the phase shift by using KID phase versus
frequency dependence using a previously measured resonant frequency. Working in
this calculated resonant frequency, we gain near linearity and constant
calibration to a constant optical signal applied in a wide range of operating
points on the resonance and readout powers. This calibration method has three
particular advantages: first, it is fast enough to be used to calibrate large
arrays, with pixel counts in the thousand of pixels; second, it is based on
data that are already necessary to determine KID positions; third, it can be
done without applying any optical source in front of the array.
[12]
oai:arXiv.org:1505.06191 [pdf] - 1238361
The non-equilibrium response of a superconductor to pair-breaking
radiation measured over a broad frequency band
de Visser, P. J.;
Yates, S. J. C.;
Guruswamy, T.;
Goldie, D. J.;
Withington, S.;
Neto, A.;
Llombart, N.;
Baryshev, A. M.;
Klapwijk, T. M.;
Baselmans, J. J. A.
Submitted: 2015-05-22
We have measured the absorption of terahertz radiation in a BCS
superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using
a broadband antenna-lens system and a tantalum microwave resonator. From low
frequencies, the response of the resonator rises rapidly to a maximum at the
gap edge of the superconductor. From there on the response drops to half the
maximum response at twice the pair-breaking energy. At higher frequencies, the
response rises again due to trapping of pair-breaking phonons in the
superconductor. In practice this is the first measurement of the frequency
dependence of the quasiparticle creation efficiency due to pair-breaking in a
superconductor. The efficiency, calculated from the different non-equilibrium
quasiparticle distribution functions at each frequency, is in agreement with
the measurements.
[13]
oai:arXiv.org:1408.3314 [pdf] - 863527
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as
Direct Detectors for Sub-millimeter Astronomy
Submitted: 2014-08-14
In the next decades millimeter and sub-mm astronomy requires large format
imaging arrays and broad-band spectrometers to complement the high spatial and
spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The
desired sensors for these instruments should have a background limited
sensitivity and a high optical efficiency and enable arrays thousands of pixels
in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and
Al have shown to satisfy these requirements. We present the second generation
hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and
amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the
increased responsivity, the photon noise level achieved in phase allows us to
simultaneously read out approximately 8000 pixels using state-of-the-art
electronics. In addition, the choice of superconducting materials and the use
of a Si lens in combination with a planar antenna gives these resonators the
flexibility to operate within the frequency range $0.09 < \nu < 1.1$ THz. Given
these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable
kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
[14]
oai:arXiv.org:1311.2429 [pdf] - 747105
High optical efficiency and photon noise limited sensitivity of
microwave kinetic inductance detectors using phase readout
Submitted: 2013-11-11
We demonstrate photon noise limited performance in both phase and amplitude
readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN
and Al, down to 100 fW of optical power. We simulate the far field beam pattern
of the lens-antenna system used to couple radiation into the MKID and derive an
aperture efficiency of 75%. This is close to the theoretical maximum of 80% for
a single-moded detector. The beam patterns are verified by a detailed analysis
of the optical coupling within our measurement setup.
[15]
oai:arXiv.org:1309.4317 [pdf] - 720075
Design and Testing of Kinetic Inductance Detectors Made of Titanium
Nitride
Submitted: 2013-09-17
To use highly resistive material for Kinetic Inductance Detectors (KID), new
designs have to be done, in part due to the impedance match needed between the
KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid
designs, with an aluminum throughline coupled to titanium nitride
microresonators, have been measured and compared to a TiN only chip. In the
hybrid chips, parasitic temperature dependent box resonances are absent. The
dark KID properties have been measured in a large set of resonators. A
surprisingly long lifetime, up to 5.6 ms is observed in a few KIDs. For the
other more reproducible devices, the mean electrical Noise Equivalent Power is
5.4 10-19 W.Hz1/2.
[16]
oai:arXiv.org:1303.7151 [pdf] - 683399
On-chip filter bank spectroscopy at 600-700 GHz using NbTiN
superconducting resonators
Submitted: 2013-03-28, last modified: 2013-06-21
We experimentally demonstrate the principle of an on-chip submillimeter wave
filter bank spectrometer, using superconducting microresonators as narrow
band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip
line resonators, which have a resonance frequency in the range of 614-685
GHz---two orders of magnitude higher in frequency than what is currently
studied for use in circuit quantum electrodynamics and photodetectors. The
frequency resolution of the filters decreases from 350 to 140 with increasing
frequency, most likely limited by dissipation of the resonators.
[17]
oai:arXiv.org:1107.4330 [pdf] - 1078138
Photon noise limited radiation detection with lens-antenna coupled
Microwave Kinetic Inductance Detectors
Submitted: 2011-07-21
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for
sub-mm instrumentation because of the high scalability of the technology. Here
we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon
noise limited performance of a small antenna coupled MKID detector array and we
describe the relation between photon noise and MKID intrinsic
generation-recombination noise. Additionally we use the observed photon noise
to measure the optical efficiency of detectors to be 0.8+-0.2.
[18]
oai:arXiv.org:1107.3333 [pdf] - 1078024
Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph
Based on Superconducting Resonators
Submitted: 2011-07-17
An integrated filterbank (IFB) in combination with microwave kinetic
inductance detectors (MKIDs), both based on superconducting resonators, could
be used to make broadband submillimeter imaging spectrographs that are compact
and flexible. In order to investigate the possibility of adopting an IFB
configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic
properties of a coplanar-waveguide-based IFB using electromagnetic simulation.
We show that a coupling efficiency greater than 1/2 can be achieved if
transmission losses are negligible. We arrive at a practical design for a 9
pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer,
which instantaneously covers multiple submillimeter telluric windows with a
dispersion of f/df = 1000.
[19]
oai:arXiv.org:1103.0758 [pdf] - 353813
Number fluctuations of sparse quasiparticles in a superconductor
Submitted: 2011-03-03, last modified: 2011-03-25
We have directly measured quasiparticle number fluctuations in a thin film
superconducting Al resonator in thermal equilibrium. The spectrum of these
fluctuations provides a measure of both the density and the lifetime of the
quasiparticles. We observe that the quasiparticle density decreases
exponentially with decreasing temperature, as theoretically predicted, but
saturates below 160 mK to 25-55 per cubic micron. We show that this saturation
is consistent with the measured saturation in the quasiparticle lifetime, which
also explains similar observations in qubit decoherence times.
[20]
oai:arXiv.org:1102.0870 [pdf] - 958350
A dual-band millimeter-wave kinetic inductance camera for the IRAM
30-meter telescope
Monfardini, A.;
Benoit, A.;
Bideaud, A.;
Swenson, L. J.;
Roesch, M.;
Desert, F. X.;
Doyle, S.;
Endo, A.;
Cruciani, A.;
Ade, P.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Bourrion, O.;
Calvo, M.;
Camus, P.;
Ferrari, L.;
Giordano, C.;
Hoffmann, C.;
Leclercq, S.;
Macias-Perez, J. F.;
Mauskopf, P.;
Schuster, K. F.;
Tucker, C.;
Vescovi, C.;
Yates, S. J. C.
Submitted: 2011-02-04, last modified: 2011-02-08
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement
system based on kinetic inductance detectors (KIDs) currently being developed
for millimeter wave astronomy. In a first technical run, NIKA was successfully
tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter
telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel
camera imaging at 150 GHz. Subsequently, an improved system has been developed
and tested in October 2010 at the Pico Veleta telescope. The instrument
upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and
220 GHz, faster sampling electronics enabling synchronous measurement of up to
112 pixels per measurement band, improved single-pixel sensitivity, and the
fabrication of a sky simulator to replicate conditions present at the
telescope. Results. The new dual-band NIKA was successfully tested in October
2010, performing in-line with sky simulator predictions. Initially the sources
targeted during the 2009 run were re-imaged, verifying the improved system
performance. An optical NEP was then calculated to be around 2 \dot 10-16
W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is
approaching the target sensitivity for photon-noise limited ground-based
detectors. Taking advantage of the larger arrays and increased sensitivity, a
number of scientifically-relevant faint and extended objects were then imaged
including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the
NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the
150 GHz and 220 GHz atmospheric windows.
[21]
oai:arXiv.org:1004.2209 [pdf] - 301556
NIKA: A millimeter-wave kinetic inductance camera
Monfardini, A.;
Swenson, L. J.;
Bideaud, A.;
Désert, F. X.;
Yates, S. J. C.;
Benoit, A.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Doyle, S.;
Klein, B.;
Roesch, M.;
Tucker, C.;
Ade, P.;
Calvo, M.;
Camus, P.;
Giordano, C.;
Guesten, R.;
Hoffmann, C.;
Leclercq, S.;
Mauskopf, P.;
Schuster, K. F.
Submitted: 2010-04-13, last modified: 2010-06-20
Current generation millimeter wavelength detectors suffer from scaling limits
imposed by complex cryogenic readout electronics. To circumvent this it is
imperative to investigate technologies that intrinsically incorporate strong
multiplexing. One possible solution is the kinetic inductance detector (KID).
In order to assess the potential of this nascent technology, a prototype
instrument optimized for the 2 mm atmospheric window was constructed. Known as
the N\'eel IRAM KIDs Array (NIKA), it was recently tested at the Institute for
Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain.
The measurement resulted in the imaging of a number of sources, including
planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar
3C345, and galaxy M87 are presented. From these results, the optical NEP was
calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10
improvement is expected to be readily feasible by improvements in the detector
materials and reduction of performance-degrading spurious radiation.
[22]
oai:arXiv.org:0903.2431 [pdf] - 22358
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
Submitted: 2009-03-13
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large
very sensitive detector arrays for use in, for example, sub-mm imaging. Being
intrinsically readout in the frequency domain, they are particularly suited for
frequency domain multiplexing allowing $\sim$1000s of devices to be readout
with one pair of coaxial cables. However, this moves the complexity of the
detector from the cryogenics to the warm electronics. We present here the
concept and experimental demonstration of the use of Fast Fourier Transform
Spectrometer (FFTS) readout, showing no deterioration of the noise performance
compared to low noise analog mixing while allowing high multiplexing ratios.