Normalized to: Miyaguchi, K.
[1]
oai:arXiv.org:1101.5673 [pdf] - 1051767
In Orbit Performance of the MAXI/SSC onboard the ISS
Submitted: 2011-01-29
We report here the in orbit performance of the CCD camera (MAXI/SSC) onboard
the International Space Station (ISS). It was commissioned in August, 2009.
This is the first all-sky survey mission employing X-ray CCDs. It consists of
32 CCDs each of which is 1 inch square. It is a slit camera with a field of
view of 1deg.5x 90deg and scans the sky as the rotation of the ISS. The CCD on
the SSC is cooled down to the working temperature around -60degC by the
combination of the peltier cooler, a loop heat pipe and a radiator. The
standard observation mode of the CCD is in a parallel sum mode (64-binning).
The CCD functions properly although it suffers an edge glow when the Sun is
near the field of view (FOV) which reduces the observation efficiency of the
SSC down to about 30%. The performance of the CCD is continuously monitored
both by the Mn-K X-rays and by the Cu-K X-rays. There are many sources
detected, not only point sources but extended sources. Due to the lack of the
effective observation time, we need more observation time to obtain an extended
emission analysis extraction process.
[2]
oai:arXiv.org:1101.3651 [pdf] - 1051536
Solid-state Slit Camera (SSC) on Board MAXI
Tomida, Hiroshi;
Tsunemi, Hiroshi;
Kimura, Masashi;
Kitayama, Hiroki;
Matsuoka, Masaru;
Ueno, Shiro;
Kawasaki, Kazuyoshi;
Katayama, Haruyoshi;
Miyaguchi, Kazuhisa;
Maeda, Kentaro;
Daikyuji, Arata;
Isobe, Naoki
Submitted: 2011-01-19
Solid-state Slit Camera (SSC) is an X-ray camera onboard the MAXI mission of
the International Space Station. Two sets of SSC sensors view X-ray sky using
charge-coupled devices (CCDs) in 0.5--12\,keV band. The total area for the
X-ray detection is about 200\,cm$\rm ^2$ which is the largest among the
missions of X-ray astronomy. The energy resolution at the CCD temperature of
$-$70 \degc is 145\,eV in full width at the half maximum (FWHM) at 5.9\,keV,
and the field of view is 1\deg .5 (FWHM) $\times$ 90\deg for each sensor. The
SSC could make a whole-sky image with the energy resolution good enough to
resolve line emissions, and monitor the whole-sky at the energy band of $<$
2\,keV for the first time in these decades.
[3]
oai:arXiv.org:0710.0785 [pdf] - 5637
Development of an n-channel CCD, CCD-NeXT1, for Soft X-ray Imager
onboard the NeXT satellite
Takagi, Shin-ichiro;
Tsuru, Takeshi Go;
Inui, Tatsuya;
Matsumoto, Hironori;
Koyama, Katsuji;
Ozawa, Hideki;
Tohiguchi, Masakuni;
Matsuura, Daisuke;
Miyata, Emi;
Tsunemi, Hiroshi;
Miyaguchi, Kazuhisa;
Maeda, Kentaro;
Kohno, Hirohiko
Submitted: 2007-10-03
NeXT (New X-ray Telescope) is the next Japanese X-ray astronomical satellite
mission after the Suzaku satellite. NeXT aims to perform wide band imaging
spectroscopy. Due to the successful development of a multilayer coated mirror,
called a supermirror, NeXT can focus X-rays in the energy range from 0.1 keV up
to 80 keV. To cover this wide energy range, we are in the process of developing
a hybrid X-ray camera, Wideband X-ray Imager (WXI) as a focal plane detector of
the supermirror. The WXI consists of X-ray CCDs (SXI) and CdTe pixelized
detectors (HXI), which cover the lower and higher X-ray energy bands of 0.1-80
keV, respectively. The X-ray CCDs of the SXI are stacked above the CdTe
pixelized detectors of the HXI. The X-ray CCDs of the SXI detect soft X-rays
below $\sim$ 10 keV and allow hard X-rays pass into the CdTe detectors of the
HXI without loss. Thus, we have been developing a "back-supportless CCD" with a
thick depletion layer, a thinned silicon wafer, and a back-supportless
structure. In this paper, we report the development and performances of an
evaluation model of CCD for the SXI, "CCD-NeXT1". We successfully fabricated
two types of CCD-NeXT1, unthinned CCDs with 625-um thick wafer and 150-um thick
thinned CCDs. By omitting the polishing process when making the thinned CCDs,
we confirmed that the polishing process does not impact the X-ray performance.
In addition, we did not find significant differences in the X-ray performance
between the two types of CCDs. The energy resolution and readout noise are
$\sim$ 140 eV (FWHM) at 5.9 keV and $\sim$5 electrons (RMS), respectively. The
estimated thickness of the depletion layer is $\sim$80 um. The performances
almost satisfy the requirements of the baseline plan of the SXI.
[4]
oai:arXiv.org:physics/0208090 [pdf] - 118996
Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of
the Monitor of All-sky X-ray Image mission onboard the International Space
Station: I. Experimental Setup and Measurement of the Charge Transfer
Inefficiency
Miyata, E.;
Kamazuka, T.;
Kouno, H.;
Mihara, M. Fukuda M.;
Matsuta, K.;
Tsunemi, H.;
Tanaka, K.;
Minamisono, T;
Tomida, H.;
Miyaguchi, K.
Submitted: 2002-08-26
We have investigated the radiation damage effects on a CCD to be employed in
the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray
Image (MAXI) onboard the International Space Station (ISS). Since low energy
protons release their energy mainly at the charge transfer channel, resulting a
decrease of the charge transfer efficiency, we thus focused on the low energy
protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to
a given device. We measured the degradation of the charge transfer inefficiency
(CTI) as a function of incremental fluence. A 292 keV proton beam degraded the
CTI most seriously. Taking into account the proton energy dependence of the
CTI, we confirmed that the transfer channel has the lowest radiation tolerance.
We have also developed the different device architectures to reduce the
radiation damage in orbit. Among them, the ``notch'' CCD, in which the buried
channel implant concentration is increased, resulting in a deeper potential
well than outside, has three times higher radiation tolerance than that of the
normal CCD. We then estimated the charge transfer inefficiency of the CCD in
the orbit of ISS, considering the proton energy spectrum. The CTI value is
estimated to be 1.1e-5 per each transfer after two years of mission life in the
worse case analysis if the highest radiation-tolerant device is employed. This
value is well within the acceptable limit and we have confirmed the high
radiation-tolerance of CCDs for the MAXI mission.
[5]
oai:arXiv.org:physics/0206021 [pdf] - 118991
Application of the Mesh Experiment for the Back-Illuminated CCD: I.
Experiment and the Charge Cloud Shape
Submitted: 2002-06-09
We have employed a mesh experiment for back-illuminated (BI) CCDs. BI CCDs
possess the same structure to those of FI CCDs. Since X-ray photons enter from
the back surface of the CCD, a primary charge cloud is formed far from the
electrodes. The primary charge cloud expands through diffusion process until it
reaches the potential well that is just below the electrodes. Therefore, the
diffusion time for the charge cloud produced is longer than that in the FI CCD,
resulting a larger charge cloud shape expected.
The mesh experiment enables us to specify the X-ray point of interaction with
a subpixel resolution. We then have measured a charge cloud shape produced in
the BI CCD. We found that there are two components of the charge cloud shape
having different size: a narrow component and a broad component. The size of
the narrow component is $2.8-5.7 \mu$m in unit of a standard deviation and
strongly depends on the attenuation length in Si of incident X-rays. The
shorter the attenuation length of X-rays is, the larger the charge cloud
becomes. This result is qualitatively consistent with a diffusion model inside
the CCD. On the other hand, the size of the broad component is roughly constant
of $\simeq 13 \mu$m and does not depend on X-ray energies. Judging from the
design value of the CCD and the fraction of each component, we conclude that
the narrow component is originated in the depletion region whereas the broad
component is in the field-free region.
[6]
oai:arXiv.org:astro-ph/0204014 [pdf] - 48559
Direct X-ray Imaging of $\mu$m precision using Back-Illuminated CCD
Submitted: 2002-04-01
A charge-coupled device (CCD) is a standard imager in optical region in which
the image quality is limited by its pixel size. CCDs also function in X-ray
region but with substantial differences in performance. An optical photon
generates only one electron while an X-ray photon generates many electrons at a
time. We developed a method to precisely determine the X-ray point of
interaction with subpixel resolution. In particular, we found that a
back-illuminated CCD efficiently functions as a fine imager. We present here
the validity of our method through an actual imaging experiment.