Normalized to: Llombart, N.
[1]
oai:arXiv.org:2001.05151 [pdf] - 2050374
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated
Superconducting Spectrometer
Takekoshi, Tatsuya;
Karatsu, Kenichi;
Suzuki, Junya;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Baselmans, Jochem J. A.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Endo, Akira
Submitted: 2020-01-15
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep
Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip
filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate
dusty star-burst galaxies in the distant universe at millimeter and
submillimeter wavelength. An on-site experiment of DESHIMA was performed using
the ASTE 10-m telescope. We established a responsivity model that converts
frequency responses of the MKIDs to line-of-sight brightness temperature. We
estimated two parameters of the responsivity model using a set of skydip data
taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for
each MKID. The line-of-sight brightness temperature of sky is estimated using
an atmospheric transmission model and the PWVs. As a result, we obtain an
average temperature calibration uncertainty of $1\sigma=4$%, which is smaller
than other photometric biases. In addition, the average forward efficiency of
0.88 in our responsivity model is consistent with the value expected from the
geometrical support structure of the telescope. We also estimate line-of-sight
PWVs of each skydip observation using the frequency response of MKIDs, and
confirm the consistency with PWVs reported by the Atacama Large
Millimeter/submillimeter Array.
[2]
oai:arXiv.org:1906.10216 [pdf] - 1963690
First light demonstration of the integrated superconducting spectrometer
Endo, Akira;
Karatsu, Kenichi;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Takekoshi, Tatsuya;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Junya;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2019-06-24, last modified: 2019-09-18
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter
(mm-submm) band is an essential tool for uncovering the dust-enshrouded portion
of the cosmic history of star formation and galaxy evolution. However, it is
challenging to scale up conventional coherent heterodyne receivers or
free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and
numbers of spatial pixels (>$10^2$). Here we present the design and first
astronomical spectra of an intrinsically scalable, integrated superconducting
spectrometer, which covers 332-377 GHz with a spectral resolution of $F/\Delta
F \sim 380$. It combines the multiplexing advantage of microwave kinetic
inductance detectors (MKIDs) with planar superconducting filters for dispersing
the signal in a single, small superconducting integrated circuit. We
demonstrate the two key applications for an instrument of this type: as an
efficient redshift machine, and as a fast multi-line spectral mapper of
extended areas. The line detection sensitivity is in excellent agreement with
the instrument design and laboratory performance, reaching the atmospheric
foreground photon noise limit on sky. The design can be scaled to bandwidths in
excess of an octave, spectral resolution up to a few thousand and frequencies
up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$
allows for compact multi-pixel spectral imagers, which would enable
spectroscopic direct imaging and large volume spectroscopic surveys that are
several orders of magnitude faster than what is currently possible.
[3]
oai:arXiv.org:1901.06934 [pdf] - 1904696
Wideband on-chip terahertz spectrometer based on a superconducting
filterbank
Endo, Akira;
Karatsu, Kenichi;
Laguna, Alejandro Pascual;
Mirzaei, Behnam;
Huiting, Robert;
Thoen, David J.;
Murugesan, Vignesh;
Yates, Stephen J. C.;
Bueno, Juan;
van Marrewijk, Nuri;
Bosma, Sjoerd;
Yurduseven, Ozan;
Llombart, Nuria;
Suzuki, Junya;
Naruse, Masato;
de Visser, Pieter J.;
van der Werf, Paul P.;
Klapwijk, Teun M.;
Baselmans, Jochem J. A.
Submitted: 2019-01-21, last modified: 2019-06-21
Terahertz spectrometers with a wide instantaneous frequency coverage for
passive remote sensing are enormously attractive for many terahertz
applications, such as astronomy, atmospheric science and security. Here we
demonstrate a wide-band terahertz spectrometer based on a single
superconducting chip. The chip consists of an antenna coupled to a transmission
line filterbank, with a microwave kinetic inductance detector behind each
filter. Using frequency division multiplexing, all detectors are read-out
simultaneously creating a wide-band spectrometer with an instantaneous
bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral
resolution of $F/\Delta F=380$ and reaches photon-noise limited sensitivity. We
discuss the chip design and fabrication, as well as the system integration and
testing. We confirm full system operation by the detection of an emission line
spectrum of methanol gas. The proposed concept allows for spectroscopic
radiation detection over large bandwidths and resolutions up to $F/\Delta
F\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the
construction of medium resolution imaging spectrometers with unprecedented
speed and sensitivity.
[4]
oai:arXiv.org:1809.04452 [pdf] - 1749362
Eliminating stray radiation inside large area imaging arrays
Yates, Stephen J. C.;
Doyle, Simon;
Barry, Peter;
Baryshev, Andrey M.;
Bueno, Juan;
Ferrari, Lorenza;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2018-09-11
With increasing array size, it is increasingly important to control stray
radiation inside the detector chips themselves. We demonstrate this effect with
focal plane arrays of absorber coupled Lumped Element microwave Kinetic
Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter
wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the
response from a point source at the pixel position is at a similar level to the
stray response integrated over the entire chip area. For the antenna coupled
arrays, we show that this effect can be suppressed by incorporating an on-chip
stray light absorber. A similar method should be possible with the LEKID array,
especially when they are lens coupled.
[5]
oai:arXiv.org:1707.02142 [pdf] - 1585646
Surface wave control for large arrays of microwave kinetic inductance
detectors
Yates, Stephen J. C.;
Baryshev, Andrey M.;
Yurduseven, Ozan;
Bueno, Juan;
Davis, Kristina K.;
Ferrari, Lorenza;
Jellema, Willem;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Baselmans, Jochem J. A.
Submitted: 2017-07-07
Large ultra-sensitive detector arrays are needed for present and future
observatories for far infra-red, submillimeter wave (THz), and millimeter wave
astronomy. With increasing array size, it is increasingly important to control
stray radiation inside the detector chips themselves, the surface wave. We
demonstrate this effect with focal plane arrays of 880 lens-antenna coupled
Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field
measurements of the MKID optical response versus the position on the array of a
reimaged optical source. We demonstrate that the optical response of a detector
in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the
peak pixel response. The result is that the power detected from a point source
at the pixel position is almost identical to the stray response integrated over
the chip area. With such a contribution, it would be impossible to measure
extended sources, while the point source sensitivity is degraded due to an
increase of the stray loading. However, we show that by incorporating an
on-chip stray light absorber, the surface wave contribution is reduced by a
factor $>$10. With the on-chip stray light absorber the point source response
is close to simulations down to the $\sim-35$ dB level, the simulation based on
an ideal Gaussian illumination of the optics. In addition, as a crosscheck we
show that the extended source response of a single pixel in the array with the
absorbing grid is in agreement with the integral of the point source
measurements.
[6]
oai:arXiv.org:1609.01952 [pdf] - 1574543
A kilo-pixel imaging system for future space based far-infrared
observatories using microwave kinetic inductance detectors
Baselmans, J. J. A.;
Bueno, J.;
Yates, S. J. C.;
Yurduseven, O.;
Llombart, N.;
Karatsu, K.;
Baryshev, A. M.;
Ferrari, L.;
Endo, A.;
Thoen, D. J.;
de Visser, P. J.;
Janssen, R. M. J.;
Murugesan, V.;
Driessen, E. F. C.;
Coiffard, G.;
Martin-Pintado, J.;
Hargrave, P.;
Griffin, M.
Submitted: 2016-09-07, last modified: 2017-03-01
Future astrophysics and cosmic microwave background space missions operating
in the far-infrared to millimetre part of the spectrum will require very large
arrays of ultra-sensitive detectors in combination with high multiplexing
factors and efficient low-noise and low-power readout systems. We have
developed a demonstrator system suitable for such applications. The system
combines a 961 pixel imaging array based upon Microwave Kinetic Inductance
Detectors (MKIDs) with a readout system capable of reading out all pixels
simultaneously with only one readout cable pair and a single cryogenic
amplifier. We evaluate, in a representative environment, the system performance
in terms of sensitivity, dynamic range, optical efficiency, cosmic ray
rejection, pixel-pixel crosstalk and overall yield at at an observation centre
frequency of 850 GHz and 20% fractional bandwidth. The overall system has an
excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19
W/rt(Hz) measured using a thermal calibration source. At a loading power per
pixel of 50fW we demonstrate white, photon noise limited detector noise down to
300 mHz. The dynamic range would allow the detection of 1 Jy bright sources
within the field of view without tuning the readout of the detectors. The
expected dead time due to cosmic ray interactions, when operated in an L2 or a
similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel
yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates
that MKID technology can provide multiplexing ratios on the order of a 1000
with state-of-the-art single pixel performance, and that the technology is now
mature enough to be considered for future space based observatories and
experiments.
[7]
oai:arXiv.org:1505.06191 [pdf] - 1238361
The non-equilibrium response of a superconductor to pair-breaking
radiation measured over a broad frequency band
de Visser, P. J.;
Yates, S. J. C.;
Guruswamy, T.;
Goldie, D. J.;
Withington, S.;
Neto, A.;
Llombart, N.;
Baryshev, A. M.;
Klapwijk, T. M.;
Baselmans, J. J. A.
Submitted: 2015-05-22
We have measured the absorption of terahertz radiation in a BCS
superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using
a broadband antenna-lens system and a tantalum microwave resonator. From low
frequencies, the response of the resonator rises rapidly to a maximum at the
gap edge of the superconductor. From there on the response drops to half the
maximum response at twice the pair-breaking energy. At higher frequencies, the
response rises again due to trapping of pair-breaking phonons in the
superconductor. In practice this is the first measurement of the frequency
dependence of the quasiparticle creation efficiency due to pair-breaking in a
superconductor. The efficiency, calculated from the different non-equilibrium
quasiparticle distribution functions at each frequency, is in agreement with
the measurements.
[8]
oai:arXiv.org:1502.00619 [pdf] - 1300145
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Chattopadhyay, G.;
Davis, G.;
Day, P. K.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V.;
Hui, H.;
Irwin, K. D.;
Jones, W. C.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leduc, H. G.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Mason, P.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Rahlin, A. S.;
Reintsema, C. D.;
Richter, S.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Trangsrud, A.;
Tucker, R. S.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.;
Zmuidzinas, J.
Submitted: 2015-02-02
We have developed antenna-coupled transition-edge sensor (TES) bolometers for
a wide range of cosmic microwave background (CMB) polarimetry experiments,
including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors
have reached maturity and this paper reports on their design principles,
overall performance, and key challenges associated with design and production.
Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at
95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric
co-aligned beams with controlled side-lobe levels. Cross-polarized response on
boresight is typically ~0.5%, consistent with cross-talk in our multiplexed
readout system. End-to-end optical efficiencies in our cameras are routinely
35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the
scalability of this design, we have deployed 2560 detectors as 1280 matched
pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as
measured directly from CMB maps in the 2013 season. Similar arrays have
recently flown in the SPIDER instrument, and development of this technology is
ongoing.
[9]
oai:arXiv.org:1403.4302 [pdf] - 862577
BICEP2 II: Experiment and Three-Year Data Set
BICEP2 Collaboration;
Ade, P. A. R;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V. V.;
Irwin, K. D.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Story, K. T.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.
Submitted: 2014-03-17, last modified: 2014-07-31
We report on the design and performance of the BICEP2 instrument and on its
three-year data set. BICEP2 was designed to measure the polarization of the
cosmic microwave background (CMB) on angular scales of 1 to 5 degrees
($\ell$=40-200), near the expected peak of the B-mode polarization signature of
primordial gravitational waves from cosmic inflation. Measuring B-modes
requires dramatic improvements in sensitivity combined with exquisite control
of systematics. The BICEP2 telescope observed from the South Pole with a 26~cm
aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new
detector design in which beam-defining slot antenna arrays couple to
transition-edge sensor (TES) bolometers, all fabricated on a common substrate.
The antenna-coupled TES detectors supported scalable fabrication and
multiplexed readout that allowed BICEP2 to achieve a high detector count of 500
bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree
angular scales. After optimization of detector and readout parameters, BICEP2
achieved an instrument noise-equivalent temperature of 15.8 $\mu$K sqrt(s). The
full data set reached Stokes Q and U map depths of 87.2 nK in square-degree
pixels (5.2 $\mu$K arcmin) over an effective area of 384 square degrees within
a 1000 square degree field. These are the deepest CMB polarization maps at
degree angular scales to date. The power spectrum analysis presented in a
companion paper has resulted in a significant detection of B-mode polarization
at degree scales.
[10]
oai:arXiv.org:1305.4281 [pdf] - 665294
Operation of a titanium nitride superconducting microresonator detector
in the nonlinear regime
Submitted: 2013-05-18
If driven sufficiently strongly, superconducting microresonators exhibit
nonlinear behavior including response bifurcation. This behavior can arise from
a variety of physical mechanisms including heating effects, grain boundaries or
weak links, vortex penetration, or through the intrinsic nonlinearity of the
kinetic inductance. Although microresonators used for photon detection are
usually driven fairly hard in order to optimize their sensitivity, most
experiments to date have not explored detector performance beyond the onset of
bifurcation. Here we present measurements of a lumped-element superconducting
microresonator designed for use as a far-infrared detector and operated deep
into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm
thick titanium nitride film with a critical temperature of 2 K and a
normal-state resistivity of $100\, \mu \Omega\,$cm. We measured the response of
the device when illuminated with 6.4 pW optical loading using microwave readout
powers that ranged from the low-power, linear regime to 18 dB beyond the onset
of bifurcation. Over this entire range, the nonlinear behavior is well
described by a nonlinear kinetic inductance. The best noise-equivalent power of
$2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout
power, and represents a $\sim$10 fold improvement compared with operating below
the onset of bifurcation.
[11]
oai:arXiv.org:1211.1652 [pdf] - 587352
MKID development for SuperSpec: an on-chip, mm-wave, filter-bank
spectrometer
Shirokoff, Erik;
Barry, Peter S.;
Bradford, Charles M.;
Chattopadhyay, Goutam;
Day, Peter;
Doyle, Simon;
Hailey-Dunsheath, Steve;
Hollister, Matthew I.;
Kovács, Attila;
McKenney, Christopher;
Leduc, Henry G.;
Llombart, Nuria;
Marrone, Daniel P.;
Mauskopf, Philip;
O'Brient, Roger;
Padin, Stephen;
Reck, Theodore;
Swenson, Loren J.;
Zmuidzinas, Jonas
Submitted: 2012-11-07
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and
submillimeter wavelength astronomy. Its very small size, wide spectral
bandwidth, and highly multiplexed readout will enable construction of powerful
multibeam spectrometers for high-redshift observations. The spectrometer
consists of a horn-coupled microstrip feedline, a bank of narrow-band
superconducting resonator filters that provide spectral selectivity, and
Kinetic Inductance Detectors (KIDs) that detect the power admitted by each
filter resonator. The design is realized using thin-film lithographic
structures on a silicon wafer. The mm-wave microstrip feedline and spectral
filters of the first prototype are designed to operate in the band from 195-310
GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed
to operate at hundreds of MHz and are fabricated from titanium nitride with a
Tc of 2K. Radiation incident on the horn travels along the mm-wave microstrip,
passes through the frequency-selective filter, and is finally absorbed by the
corresponding KID where it causes a measurable shift in the resonant frequency.
In this proceedings, we present the design of the KIDs employed in SuperSpec
and the results of initial laboratory testing of a prototype device. We will
also briefly describe the ongoing development of a demonstration instrument
that will consist of two 500-channel, R=700 spectrometers, one operating in the
1-mm atmospheric window and the other covering the 650 and 850 micron bands.
[12]
oai:arXiv.org:1211.0934 [pdf] - 585657
SuperSpec: design concept and circuit simulations
Kovács, Attila;
Barry, Peter S.;
Bradford, Charles M.;
Chattopadhyay, Goutam;
Day, Peter;
Doyle, Simon;
Hailey-Dunsheath, Steve;
Hollister, Matthew;
McKenney, Christopher;
LeDuc, Henry G.;
Llombart, Nuria;
Marrone, Daniel P.;
Mauskopf, Philip;
O'Brient, Roger;
Padin, Stephen;
Swenson, Loren J.;
Zmuidzinas, Jonas
Submitted: 2012-11-05
SuperSpec is a pathfinder for future lithographic spectrometer cameras, which
promise to energize extra-galactic astrophysics at (sub)millimeter wavelengths:
delivering 200--500 km/s spectral velocity resolution over an octave bandwidth
for every pixel in a telescope's field of view. We present circuit simulations
that prove the concept, which enables complete millimeter-band spectrometer
devices in just a few square-millimeter footprint. We evaluate both
single-stage and two-stage channelizing filter designs, which separate channels
into an array of broad-band detectors, such as bolometers or kinetic inductance
detector (KID) devices. We discuss to what degree losses (by radiation or by
absorption in the dielectric) and fabrication tolerances affect the resolution
or performance of such devices, and what steps we can take to mitigate the
degradation. Such design studies help us formulate critical requirements on the
materials and fabrication process, and help understand what practical limits
currently exist to the capabilities these devices can deliver today or over the
next few years.
[13]
oai:arXiv.org:1009.3685 [pdf] - 1040693
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Orlando, A.;
Aikin, R. W;
Amiri, M.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Chattopadthyay, G.;
Day, P. K.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Irwin, K. D.;
Kenyon, M.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
LeDuc, H. G.;
Llombart, N.;
Nguyen, H. T.;
Ogburn, R. W.;
Reintsema, C. D.;
Runyan, M. C.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Trangsrud, A. R.;
Turner, A. D.;
Wilson, P.
Submitted: 2010-09-19
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters
targeting the B-mode polarization induced by primordial gravitational waves
from inflation. They will be using planar arrays of polarization sensitive
antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220
GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays
are assembled together to make a focal plane, for a total of 256
dual-polarization elements (512 TES sensors). The detector arrays are
integrated with a time-domain SQUID multiplexer developed at NIST and read out
using the multi-channels electronics (MCE) developed at the University of
British Columbia. Following our progress in improving detector parameters
uniformity across the arrays and fabrication yield, our main effort has focused
on improving detector arrays optical and noise performances, in order to
produce science grade focal planes achieving target sensitivities. We report on
changes in detector design implemented to optimize such performances and
following focal plane arrays characterization. BICEP2 has deployed a first 150
GHz science grade focal plane to the South Pole in December 2009.