Normalized to: Kole, M.
[1]
oai:arXiv.org:1910.07941 [pdf] - 1981865
Phase-resolved gamma-ray spectroscopy of the Crab pulsar observed by
POLAR
Li, Han-Cheng;
Gauvin, Neal;
Ge, Ming-Yu;
Hajdas, Wojtek;
Kole, Merlin;
Li, Zheng-Heng;
Produit, Nicolas;
Song, Li-Ming;
Sun, Jian-Chao;
Szabelski, Jacek;
Tymieniecka, Teresa;
Yuan-HaoWang;
Wu, Bo-Bing;
Wu, Xin;
Xiong, Shao-Lin;
Shuang-NanZhang;
Zhang, Yong-Jie;
Zheng, Shi-Jie
Submitted: 2019-10-17
The POLAR detector is a space based Gamma-Ray Burst (GRB) polarimeter
sensitive in the 15-500 keV energy range. Apart from its main scientific goal
as a Gamma-Ray Burst polarimeter it is also able to detect photons from pulsars
in orbit. By using the six-months in-orbit observation data, significant
pulsation from the PSR B0531+21 (Crab pulsar) was obtained. In this work, we
present the precise timing analysis of the Crab pulsar, together with a
phase-resolved spectroscopic study using a joint-fitting method adapted for
wide field of view instruments like POLAR. By using single power law fitting
over the pulsed phase, we obtained spectral indices ranging from 1.718 to
2.315, and confirmed the spectral evolution in a reverse S shape which is
homogenous with results from other missions over broadband. We will also show,
based on the POLAR in-orbit performance and Geant4 Monte-Carlo simulation, the
inferred capabilities of POLAR-2, the proposed follow-up mission of POLAR on
board the China Space Station (CSS), for pulsars studies.
[2]
oai:arXiv.org:1901.04719 [pdf] - 1935513
Time-Resolved GRB Polarization with POLAR and GBM
Submitted: 2019-01-15, last modified: 2019-08-12
Simultaneous $\gamma$-ray measurements of gamma-ray burst (GRB) spectra and
polarization offer a unique way to determine the underlying emission
mechanism(s) in these objects as well as probing the particle acceleration
mechanism(s) that lead to the observed $\gamma$-ray emission. Herein we examine
the jointly-observed data from POLAR and GBM of GRB 170114A to determine its
spectral and polarization properties and seek to understand the emission
processes that generate these observations. We aim to develop an extensible and
statistically sound framework for these types of measurements applicable to
other instruments. We leverage the existing 3ML analysis framework to develop a
new analysis pipeline for simultaneously modeling the spectral and polarization
data. We derive the proper Poisson likelihood for $\gamma$-ray polarization
measurements in the presence of background. The developed framework is publicly
available for similar measurements with other $\gamma$-ray polarimeters. The
data are analyzed within a Bayesian probabilistic context and the spectral data
from both instruments are simultaneously modeled with a physical, numerical
synchrotron code. The spectral modeling of the data is consistent with a
synchrotron photon model as has been found in a majority of similarly analyzed
single-pulse GRBs. The polarization results reveal a slight trend of growing
polarization in time reaching values of ~30% at the temporal peak of the
emission. Additionally, it is observed that the polarization angle evolves with
time throughout the emission. These results hint at a synchrotron origin of the
emission but further observations of many GRBs are required to verify these
evolutionary trends. Furthermore, we encourage the development of time-resolved
polarization models for the prompt emission of GRBs as the current models are
not predictive enough to enable a full modeling of our current data.
[3]
oai:arXiv.org:1901.04351 [pdf] - 1818883
Penetrating particle ANalyzer (PAN)
Wu, X.;
Ambrosi, G.;
Azzarello, P.;
Bergmann, B.;
Bertucci, B.;
Cadoux, F.;
Campbell, M.;
Duranti, M.;
Ionica, M.;
Kole, M.;
Krucker, S.;
Maehlum, G.;
Meier, D.;
Paniccia, M.;
Pinsky, L.;
Plainaki, C.;
Pospisil, S.;
Stein, T.;
Thonet, P. A.;
Tomassetti, N.;
Tykhonov, A.
Submitted: 2019-01-14, last modified: 2019-01-21
PAN is a scientific instrument suitable for deep space and interplanetary
missions. It can precisely measure and monitor the flux, composition, and
direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep
space, over at least one full solar cycle (~11 years). The science program of
PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar
physics, space weather and space travel. PAN will fill an observation gap of
galactic cosmic rays in the GeV region, and provide precise information of the
spectrum, composition and emission time of energetic particle originated from
the Sun. The precise measurement and monitoring of the energetic particles is
also a unique contribution to space weather studies. PAN will map the flux and
composition of penetrating particles, which cannot be shielded effectively,
precisely and continuously, providing valuable input for the assessment of the
related health risk, and for the development of an adequate mitigation
strategy. PAN has the potential to become a standard on-board instrument for
deep space human travel.
PAN is based on the proven detection principle of a magnetic spectrometer,
but with novel layout and detection concept. It will adopt advanced particle
detection technologies and industrial processes optimized for deep space
application. The device will require limited mass (~20 kg) and power (~20 W)
budget. Dipole magnet sectors built from high field permanent magnet Halbach
arrays, instrumented in a modular fashion with high resolution silicon strip
detectors, allow to reach an energy resolution better than 10\% for nuclei from
H to Fe at 1 GeV/n.
[4]
oai:arXiv.org:1901.04207 [pdf] - 1857202
Detailed polarization measurements of the prompt emission of five
Gamma-Ray Bursts
Zhang, Shuang-Nan;
Kole, Merlin;
Bao, Tian-Wei;
Batsch, Tadeusz;
Bernasconi, Tancredi;
Cadoux, Franck;
Chai, Jun-Ying;
Dai, Zi-Gao;
Dong, Yong-Wei;
Gauvin, Neal;
Hajdas, Wojtek;
Lan, Mi-Xiang;
Li, Han-Cheng;
Li, Lu;
Li, Zheng-Heng;
Liu, Jiang-Tao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Produit, Nicolas;
Pohl, Martin;
Rybka, Dominik;
Shi, Hao-Li;
Song, Li-Ming;
Sun, Jian-Chao;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Rui-Jie;
Wang, Yuan-Hao;
Wen, Xing;
Wu, Bo-Bing;
Wu, Xin;
Wu, Xue-Feng;
Xiao, Hua-Lin;
Xiong, Shao-Lin;
Zhang, Lai-Yu;
Zhang, Li;
Zhang, Xiao-Feng;
Zhang, Yong-Jie;
Zwolinska, Anna
Submitted: 2019-01-14
Gamma-ray bursts are the strongest explosions in the Universe since the Big
Bang, believed to be produced either in forming black holes at the end of
massive star evolution or merging of compact objects. Spectral and timing
properties of gamma-ray bursts suggest that the observed bright gamma-rays are
produced in the most relativistic jets in the Universe; however, the physical
properties, especially the structure and magnetic topologies in the jets are
still not well known, despite several decades of studies. It is widely believed
that precise measurements of the polarization properties of gamma-ray bursts
should provide crucial information on the highly relativistic jets. As a result
there have been many reports of gamma-ray burst polarization measurements with
diverse results, see, however many such measurements suffered from substantial
uncertainties, mostly systematic. After the first successful measurements by
the GAP and COSI instruments, here we report a statistically meaningful sample
of precise polarization measurements, obtained with the dedicated gamma-ray
burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results
suggest that the gamma-ray emission is at most polarized at a level lower than
some popular models have predicted; although our results also show intrapulse
evolution of the polarization angle. This indicates that the low polarization
degrees could be due to an evolving polarization angle during a gamma-ray
burst.
[5]
oai:arXiv.org:1711.01265 [pdf] - 1774557
Science with e-ASTROGAM (A space mission for MeV-GeV gamma-ray
astrophysics)
De Angelis, A.;
Tatischeff, V.;
Grenier, I. A.;
McEnery, J.;
Mallamaci, M.;
Tavani, M.;
Oberlack, U.;
Hanlon, L.;
Walter, R.;
Argan, A.;
Von Ballmoos, P.;
Bulgarelli, A.;
Bykov, A.;
Hernanz, M.;
Kanbach, G.;
Kuvvetli, I.;
Pearce, M.;
Zdziarski, A.;
Conrad, J.;
Ghisellini, G.;
Harding, A.;
Isern, J.;
Leising, M.;
Longo, F.;
Madejski, G.;
Martinez, M.;
Mazziotta, M. N.;
Paredes, J. M.;
Pohl, M.;
Rando, R.;
Razzano, M.;
Aboudan, A.;
Ackermann, M.;
Addazi, A.;
Ajello, M.;
Albertus, C.;
Alvarez, J. M.;
Ambrosi, G.;
Anton, S.;
Antonelli, L. A.;
Babic, A.;
Baibussinov, B.;
Balbo, M.;
Baldini, L.;
Balman, S.;
Bambi, C.;
de Almeida, U. Barres;
Barrio, J. A.;
Bartels, R.;
Bastieri, D.;
Bednarek, W.;
Bernard, D.;
Bernardini, E.;
Bernasconi, T.;
Bertucci, B.;
Biland, A.;
Bissaldi, E.;
Boettcher, M.;
Bonvicini, V.;
Ramon, V. Bosch;
Bottacini, E.;
Bozhilov, V.;
Bretz, T.;
Branchesi, M.;
Brdar, V.;
Bringmann, T.;
Brogna, A.;
Jorgensen, C. Budtz;
Busetto, G.;
Buson, S.;
Busso, M.;
Caccianiga, A.;
Camera, S.;
Campana, R.;
Caraveo, P.;
Cardillo, M.;
Carlson, P.;
Celestin, S.;
Cermeno, M.;
Chen, A.;
Cheung, C. C;
Churazov, E.;
Ciprini, S.;
Coc, A.;
Colafrancesco, S.;
Coleiro, A.;
Collmar, W.;
Coppi, P.;
da Silva, R. Curado;
Cutini, S.;
DAmmando, F.;
De Lotto, B.;
de Martino, D.;
De Rosa, A.;
Del Santo, M.;
Delgado, L.;
Diehl, R.;
Dietrich, S.;
Dolgov, A. D.;
Dominguez, A.;
Prester, D. Dominis;
Donnarumma, I.;
Dorner, D.;
Doro, M.;
Dutra, M.;
Elsaesser, D.;
Fabrizio, M.;
FernandezBarral, A.;
Fioretti, V.;
Foffano, L.;
Formato, V.;
Fornengo, N.;
Foschini, L.;
Franceschini, A.;
Franckowiak, A.;
Funk, S.;
Fuschino, F.;
Gaggero, D.;
Galanti, G.;
Gargano, F.;
Gasparrini, D.;
Gehrz, R.;
Giammaria, P.;
Giglietto, N.;
Giommi, P.;
Giordano, F.;
Giroletti, M.;
Ghirlanda, G.;
Godinovic, N.;
Gouiffes, C.;
Grove, J. E.;
Hamadache, C.;
Hartmann, D. H.;
Hayashida, M.;
Hryczuk, A.;
Jean, P.;
Johnson, T.;
Jose, J.;
Kaufmann, S.;
Khelifi, B.;
Kiener, J.;
Knodlseder, J.;
Kole, M.;
Kopp, J.;
Kozhuharov, V.;
Labanti, C.;
Lalkovski, S.;
Laurent, P.;
Limousin, O.;
Linares, M.;
Lindfors, E.;
Lindner, M.;
Liu, J.;
Lombardi, S.;
Loparco, F.;
LopezCoto, R.;
Moya, M. Lopez;
Lott, B.;
Lubrano, P.;
Malyshev, D.;
Mankuzhiyil, N.;
Mannheim, K.;
Marcha, M. J.;
Marciano, A.;
Marcote, B.;
Mariotti, M.;
Marisaldi, M.;
McBreen, S.;
Mereghetti, S.;
Merle, A.;
Mignani, R.;
Minervini, G.;
Moiseev, A.;
Morselli, A.;
Moura, F.;
Nakazawa, K.;
Nava, L.;
Nieto, D.;
Orienti, M.;
Orio, M.;
Orlando, E.;
Orleanski, P.;
Paiano, S.;
Paoletti, R.;
Papitto, A.;
Pasquato, M.;
Patricelli, B.;
PerezGarcia, M. A.;
Persic, M.;
Piano, G.;
Pichel, A.;
Pimenta, M.;
Pittori, C.;
Porter, T.;
Poutanen, J.;
Prandini, E.;
Prantzos, N.;
Produit, N.;
Profumo, S.;
Queiroz, F. S.;
Raino, S.;
Raklev, A.;
Regis, M.;
Reichardt, I.;
Rephaeli, Y.;
Rico, J.;
Rodejohann, W.;
Fernandez, G. Rodriguez;
Roncadelli, M.;
Roso, L.;
Rovero, A.;
Ruffini, R.;
Sala, G.;
SanchezConde, M. A.;
Santangelo, A.;
Parkinson, P. Saz;
Sbarrato, T.;
Shearer, A.;
Shellard, R.;
Short, K.;
Siegert, T.;
Siqueira, C.;
Spinelli, P.;
Stamerra, A.;
Starrfield, S.;
Strong, A.;
Strumke, I.;
Tavecchio, F.;
Taverna, R.;
Terzic, T.;
Thompson, D. J.;
Tibolla, O.;
Torres, D. F.;
Turolla, R.;
Ulyanov, A.;
Ursi, A.;
Vacchi, A.;
Abeele, J. Van den;
Kirilovai, G. Vankova;
Venter, C.;
Verrecchia, F.;
Vincent, P.;
Wang, X.;
Weniger, C.;
Wu, X.;
Zaharijas, G.;
Zampieri, L.;
Zane, S.;
Zimmer, S.;
Zoglauer, A.;
collaboration, the eASTROGAM
Submitted: 2017-11-03, last modified: 2018-08-08
e-ASTROGAM (enhanced ASTROGAM) is a breakthrough Observatory space mission,
with a detector composed by a Silicon tracker, a calorimeter, and an
anticoincidence system, dedicated to the study of the non-thermal Universe in
the photon energy range from 0.3 MeV to 3 GeV - the lower energy limit can be
pushed to energies as low as 150 keV for the tracker, and to 30 keV for
calorimetric detection. The mission is based on an advanced space-proven
detector technology, with unprecedented sensitivity, angular and energy
resolution, combined with polarimetric capability. Thanks to its performance in
the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will
open a new window on the non-thermal Universe, making pioneering observations
of the most powerful Galactic and extragalactic sources, elucidating the nature
of their relativistic outflows and their effects on the surroundings. With a
line sensitivity in the MeV energy range one to two orders of magnitude better
than previous generation instruments, e-ASTROGAM will determine the origin of
key isotopes fundamental for the understanding of supernova explosion and the
chemical evolution of our Galaxy. The mission will provide unique data of
significant interest to a broad astronomical community, complementary to
powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT,
LSST, JWST, Athena, CTA, IceCube, KM3NeT, and LISA.
[6]
oai:arXiv.org:1710.08918 [pdf] - 1724839
In-flight energy calibration of the space-borne Compton polarimeter
POLAR
Xiao, Hualin;
Hajdas, Wojtek;
Wu, Bobing;
Produit, Nicolas;
Sun, Jianchao;
Kole, Merlin;
Bao, Tianwei;
Bernasconi, Tancredi;
Batsch, Tadeusz;
Cadoux, Franck;
Chai, Junying;
Dong, Yongwei;
Egli, Ken;
Gauvin, Neal;
Kong, Minnan;
Kramert, Reinhold;
Kong, Siwei;
Li, Hancheng;
Li, Lu;
Li, Zhengheng;
Liu, Jiangtao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Rybka, Dominik K.;
Pohl, Martin;
Shi, Haoli;
Song, Liming;
Xiong, Shaolin;
Szabelski, Jacek;
Socha, Patryk;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Zhang, Laiyu;
Zhang, Ping;
Zhang, Shuangnan;
Zhang, Xiaofeng;
Zhang, Yongjie;
Zhao, Yi;
Zwolinska, Anna
Submitted: 2017-10-24, last modified: 2018-06-05
POLAR is a compact wide-field space-borne detector for precise measurements
of the linear polarisation of hard X-rays emitted by transient sources in the
energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of
plastic scintillator bars used as a detection material. The bars are grouped in
25 detector modules. The energy range sensitivity of POLAR is optimized to
match with the prompt emission photons from the gamma-ray bursts (GRBs).
Polarization measurements of the prompt emission would probe source geometries,
emission mechanisms and magnetic structures in GRB jets. The instrument can
also detect hard X-rays from solar flares and be used for precise measurement
of their polarisation. POLAR was launched into a low Earth orbit on-board the
Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in
polarisation measurements it is essential to assure both before and during the
flight a precise energy calibration. Such calibrations are performed with four
low activity $^{22}$Na radioactive sources placed inside the instrument. Energy
conversion factors are related to Compton edge positions from the collinear
annihilation photons from the sources. This paper presents main principles of
the in-flight calibration, describes studies of the method based on Monte Carlo
simulations and its laboratory verification and finally provides some
observation results based on the in-flight data analysis.
[7]
oai:arXiv.org:1805.07605 [pdf] - 1690419
In-Orbit Instrument Performance Study and Calibration for POLAR
Polarization Measurements
Li, Zhengheng;
Kole, Merlin;
Sun, Jianchao;
Song, Liming;
Produit, Nicolas;
Wu, Bobing;
Bao, Tianwei;
Bernasconi, Tancredi;
Cadoux, Franck;
Dong, Yongwei;
Feng, Minzi;
Gauvin, Neal;
Hajdas, Wojtek;
Li, Hancheng;
Li, Lu;
Liu, Xin;
Marcinkowski, Radoslaw;
Pohl, Martin;
Rybka, Dominik K.;
Shi, Haoli;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Xiong, Shaolin;
Zwolinska, Anna;
Zhang, Li;
Zhang, Laiyu;
Zhang, Shuangnan;
Zhang, Yongjie;
Zhao, Yi
Submitted: 2018-05-19, last modified: 2018-05-28
POLAR is a compact space-borne detector designed to perform reliable
measurements of the polarization for transient sources like Gamma-Ray Bursts in
the energy range 50-500keV. The instrument works based on the Compton
Scattering principle with the plastic scintillators as the main detection
material along with the multi-anode photomultiplier tube. POLAR has been
launched successfully onboard the Chinese space laboratory TG-2 on 15th
September, 2016. In order to reliably reconstruct the polarization information
a highly detailed understanding of the instrument is required for both data
analysis and Monte Carlo studies. For this purpose a full study of the in-orbit
performance was performed in order to obtain the instrument calibration
parameters such as noise, pedestal, gain nonlinearity of the electronics,
threshold, crosstalk and gain, as well as the effect of temperature on the
above parameters. Furthermore the relationship between gain and high voltage of
the multi-anode photomultiplier tube has been studied and the errors on all
measurement values are presented. Finally the typical systematic error on
polarization measurements of Gamma-Ray Bursts due to the measurement error of
the calibration parameters are estimated using Monte Carlo simulations.
[8]
oai:arXiv.org:1804.04864 [pdf] - 1665531
Polarimetry with POLAR
Submitted: 2018-04-13
In the first half year of operation the satellite borne POLAR instrument
detected a total of 55 Gamma-Ray Bursts about 10 of which were bright enough to
allow for detailed polarization studies, thereby forming the start of the first
Gamma-Ray Burst polarization catalog. In this paper a brief overview of the
previous GRB polarization studies will be presented followed by an overview of
the POLAR detector along with the first result of the in-flight performance.
The detected Gamma-Ray bursts will be presented and finally prospects for
polarization measurements of these events will be discussed.
[9]
oai:arXiv.org:1709.07191 [pdf] - 1588657
Design and construction of the POLAR detector
Produit, N.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Britvich, I.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
Kole, M.;
Kong, M. N.;
Kramert, R.;
Li, L.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Rutczynska, A.;
Shi, H. L.;
Socha, P.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Traseira, I.;
Xiao, H. L.;
Wang, R. J.;
Wen, X.;
Wu, B. B.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-09-21, last modified: 2017-09-28
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a
wide field of view, which covers almost half the sky. The instrument uses
Compton scattering of gamma rays on a plastic scintillator hodoscope to measure
the polarization of the incoming photons. The instrument has been successfully
launched on board of the Chinese space laboratory Tiangong~2 on September 15,
2016. The construction of the instrument components is described in this
article. Details are provided on problems encountered during the construction
phase and their solutions. Initial performance of the instrument in orbit is as
expected from ground tests and Monte Carlo simulation.
[10]
oai:arXiv.org:1708.00664 [pdf] - 1586674
Instrument Performance and Simulation Verification of the POLAR Detector
Kole, M.;
Li, Z. H.;
Produit, N.;
Tymieniecka, T.;
Zhang, J.;
Zwolinska, A.;
Bao, T. W.;
Bernasconi, T.;
Cadoux, F.;
Feng, M. Z.;
Gauvin, N.;
Hajdas, W.;
Kong, S. W.;
Li, H. C.;
Li, L.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rybka, D.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zhao, Y.
Submitted: 2017-08-02
POLAR is a new satellite-born detector aiming to measure the polarization of
an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The
instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of
September 2016, is designed to measure the polarization of the hard X-ray flux
by measuring the distribution of the azimuthal scattering angles of the
incoming photons. A detailed understanding of the polarimeter and specifically
of the systematic effects induced by the instrument's non-uniformity are
required for this purpose. In order to study the instrument's response to
polarization, POLAR underwent a beam test at the European Synchrotron Radiation
Facility in France. In this paper both the beam test and the instrument
performance will be described. This is followed by an overview of the Monte
Carlo simulation tools developed for the instrument. Finally a comparison of
the measured and simulated instrument performance will be provided and the
instrument response to polarization will be presented.
[11]
oai:arXiv.org:1703.04210 [pdf] - 1547762
Gain factor and parameter settings optimization of the new gamma-ray
burst polarimeter POLAR
Zhang, X. F.;
Hajdas, W.;
Xiao, H. L.;
Wen, X.;
Wu, B. B.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
He, J. J.;
Kole, M.;
Kong, M. N.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wu, X.;
Xiong, S. L.;
Xu, M.;
Zhang, L.;
Zhang, L. Y.;
Zhang, P.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-03-12, last modified: 2017-03-14
As a space-borne detector POLAR is designed to conduct hard X-ray
polarization measurements of gamma-ray bursts on the statistically significant
sample of events and with an unprecedented accuracy. During its development
phase a number of tests, calibrations runs and verification measurements were
carried out in order to validate instrument functionality and optimize
operational parameters. In this article we present results on gain optimization
togeter with verification data obtained in the course of broad laboratory and
environmental tests. In particular we focus on exposures to the $^{137}$Cs
radioactive source and determination of the gain dependence on the high voltage
for all 1600 detection channels of the polarimeter. Performance of the
instrument is described in detail with respect to the dynamic range, energy
resolution and temperature dependence. Gain optimization algorithms and
response non-uniformity studies are also broadly discussed. Results presented
below constitute important parts for development of the POLAR calibration and
operation database.
[12]
oai:arXiv.org:1612.04098 [pdf] - 1533322
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB
Polarimeter
Kole, M.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
He, J. J.;
Kong, M. N.;
Kong, S. W.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. J.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Xiong, S. L.;
Xu, H. H.;
Xu, M.;
Zhang, J.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2016-12-13
Gamma-ray polarimetry is a new powerful tool to study the processes
responsible for the emission from astrophysical sources and the environments in
which this emission takes place. Few successful polarimetric measurements have
however been performed thus far in the gamma-ray energy band due to the
difficulties involved. POLAR is a dedicated polarimeter designed to perform
high precision measurements of the polarization of the emission from gamma-ray
burst in the 50-500 keV energy range. This new polarimeter is expected to
detect approximately 50 gamma-ray bursts per year while performing high
precision polarization measurements on approximately 10 bursts per year. The
instrument was launched into lower earth orbit as part of the second Chinese
space lab, the Tiangong-2, on September 15th 2016 and has been taking data
successfully since being switched on one week after. The instrument uses a
segmented scintillator array consisting of 1600 plastic scintillator bars, read
out by 25 flat-panel multi-anode photomultipliers, to measure the Compton
scattering angles of incoming photons. The small segmentation and relatively
large uniform effective area allow the instrument to measure the polarization
of a large number of transient events, such as gamma-ray bursts, with an
unprecedented precision during its two year life-time. The final flight model
underwent detailed calibration prior to launch as well as intensive space
qualification tests, a summary of which will be presented in this paper. The
instrument design will be discussed first followed by an overview of the
on-ground tests, finally the in-orbit behavior as measured during the first
weeks of the mission will be presented.
[13]
oai:arXiv.org:1606.04504 [pdf] - 1424762
Optimising a balloon-borne polarimeter in the hard X-ray domain: from
the PoGOLite Pathfinder to PoGO+
Submitted: 2016-06-14
PoGOLite is a balloon-borne hard X-ray polarimeter dedicated to the study of
point sources. Compton scattered events are registered using an array of
plastic scintillator units to determine the polarisation of incident X-rays in
the energy range 20 - 240 keV. In 2013, a near circumpolar balloon flight of 14
days duration was completed after launch from Esrange, Sweden, resulting in a
measurement of the linear polarisation of the Crab emission. Building on the
experience gained from this Pathfinder flight, the polarimeter is being
modified to improve performance for a second flight in 2016. Such
optimisations, based on Geant4 Monte Carlo simulations, take into account the
source characteristics, the instrument response and the background environment
which is dominated by atmospheric neutrons. This paper describes the
optimisation of the polarimeter and details the associated increase in
performance. The resulting design, PoGO+, is expected to improve the Minimum
Detectable Polarisation (MDP) for the Crab from 19.8% to 11.1% for a 5 day
flight. Assuming the same Crab polarisation fraction as measured during the
2013 flight, this improvement in MDP will allow a 5{\sigma} constrained result.
It will also allow the study of the nebula emission only (Crab off-pulse) and
Cygnus X-1 if in the hard state.
[14]
oai:arXiv.org:1512.02784 [pdf] - 1515698
Calibration of Gamma-ray Burst Polarimeter POLAR
Xiao, H. L.;
Hajdas, W.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Kole, M.;
Kong, M. N.;
Kong, S. W.;
Li, L.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wu, B. B.;
Wang, R. J.;
Wen, X.;
Xu, H. H.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2015-12-09
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which
might be associated with creation of black holes. Magnetic field structure and
burst dynamics may influence polarization of the emitted gamma-rays. Precise
polarization detection can be an ultimate tool to unveil the true GRB
mechanism. POLAR is a space-borne Compton scattering detector for precise
measurements of the GRB polarization. It consists of a 40$\times$40 array of
plastic scintillator bars read out by 25 multi-anode PMTs (MaPMTs). It is
scheduled to be launched into space in 2016 onboard of the Chinese space
laboratory TG2. We present a dedicated methodology for POLAR calibration and
some calibration results based on the combined use of the laboratory
radioactive sources and polarized X-ray beams from the European Synchrotron
Radiation Facility. They include calibration of the energy response,
computation of the energy conversion factor vs. high voltage as well as
determination of the threshold values, crosstalk contributions and polarization
modulation factors.
[15]
oai:arXiv.org:1511.02735 [pdf] - 1331098
Observation of polarised hard X-ray emission from the Crab by the
PoGOLite Pathfinder
Chauvin, M.;
Florén, H. -G.;
Jackson, M.;
Kamae, T.;
Kawano, T.;
Kiss, M.;
Kole, M.;
Mikhalev, V.;
Moretti, E.;
Olofsson, G.;
Rydström, S.;
Takahashi, H.;
Iyudin, A.;
Arimoto, M.;
Fukazawa, Y.;
Kataoka, J.;
Kawai, N.;
Mizuno, T.;
Ryde, F.;
Tajima, H.;
Takahashi, T.;
Pearce, M.
Submitted: 2015-11-09, last modified: 2015-11-30
We have measured the linear polarisation of hard X-ray emission from the Crab
in a previously unexplored energy interval, 20-120 keV. The introduction of two
new observational parameters, the polarisation fraction and angle stands to
disentangle geometrical and physical effects, thereby providing information on
the pulsar wind geometry and magnetic field environment. Measurements are
conducted using the PoGOLite Pathfinder - a balloon-borne polarimeter.
Polarisation is determined by measuring the azimuthal Compton scattering angle
of incident X-rays in an array of plastic scintillators housed in an
anticoincidence well. The polarimetric response has been characterised prior to
flight using both polarised and unpolarised calibration sources. We address
possible systematic effects through observations of a background field. The
measured polarisation fraction for the integrated Crab light-curve is
($18.4^{+9.8}_{-10.6}$)%, corresponding to an upper limit (99% credibility) of
42.4%, for a polarisation angle of ($149.2\pm16.0)^\circ$.
[16]
oai:arXiv.org:1508.03345 [pdf] - 1450593
The design and flight performance of the PoGOLite Pathfinder
balloon-borne hard X-ray polarimeter
Chauvin, M.;
Florén, H. -G.;
Jackson, M.;
Kamae, T.;
Kawano, T.;
Kiss, M.;
Kole, M.;
Mikhalev, V.;
Moretti, E.;
Olofsson, G.;
Rydström, S.;
Takahashi, H.;
Lind, J.;
Strömberg, J. -E.;
Welin, O.;
Iyudin, A.;
Shifrin, D.;
Pearce, M.
Submitted: 2015-08-13
In the 50 years since the advent of X-ray astronomy there have been many
scientific advances due to the development of new experimental techniques for
detecting and characterising X-rays. Observations of X-ray polarisation have,
however, not undergone a similar development. This is a shortcoming since a
plethora of open questions related to the nature of X-ray sources could be
resolved through measurements of the linear polarisation of emitted X-rays. The
PoGOLite Pathfinder is a balloon-borne hard X-ray polarimeter operating in the
25 - 240 keV energy band from a stabilised observation platform. Polarisation
is determined using coincident energy deposits in a segmented array of plastic
scintillators surrounded by a BGO anticoincidence system and a polyethylene
neutron shield. The PoGOLite Pathfinder was launched from the SSC Esrange Space
Centre in July 2013. A near-circumpolar flight was achieved with a duration of
approximately two weeks. The flight performance of the Pathfinder design is
discussed for the three Crab observations conducted. The signal-to-background
ratio for the observations is shown to be 0.25$\pm$0.03 and the Minimum
Detectable Polarisation (99% C.L.) is (28.4$\pm$2.2)%. A strategy for the
continuation of the PoGOLite programme is outlined based on experience gained
during the 2013 maiden flight.
[17]
oai:arXiv.org:1505.08093 [pdf] - 1085885
Preflight performance studies of the PoGOLite hard X-ray polarimeter
Submitted: 2015-05-29
Polarimetric studies of astrophysical sources can make important
contributions to resolve the geometry of the emitting region and determine the
photon emission mechanism. PoGOLite is a balloon-borne polarimeter operating in
the hard X-ray band (25-240 keV), with a Pathfinder mission focussing on Crab
observations. Within the polarimeter, the distribution of Compton scattering
angles is used to determine the polarisation fraction and angle of incident
photons. To assure an unbiased measurement of the polarisation during a balloon
flight it is crucial to characterise the performance of the instrument before
the launch. This paper presents the results of the PoGOLite calibration tests
and simulations performed before the 2013 balloon flight. The tests performed
confirm that the polarimeter does not have any intrinsic asymmetries and
therefore does not induce bias into the measurements. Generally, good agreement
is found between results from test data and simulations which allows the
polarimeter performance to be estimated for Crab observations.
[18]
oai:arXiv.org:1410.2377 [pdf] - 878528
PoGOLino: a scintillator-based balloon-borne neutron detector
Kole, Merlin;
Chauvin, Maxime;
Fukazawa, Yasushi;
Fukuda, Kentaro;
Ishizu, Sumito;
Jackson, Miranda;
Kamae, Tune;
Kawaguchi, Noriaki;
Kawano, Takafumi;
Kiss, Mozsi;
Moretti, Elena;
Pearce, Mark;
Rydström, Stefan;
Takahashi, Hiromitsu;
Yanagida, Takayuki
Submitted: 2014-10-09
PoGOLino is a balloon-borne scintillator-based experiment developed to study
the largely unexplored high altitude neutron environment at high geomagnetic
latitudes. The instrument comprises two detectors that make use of LiCAF, a
novel neutron sensitive scintillator, sandwiched by BGO crystals for background
reduction. The experiment was launched on March 20th 2013 from the Esrange
Space Centre, Northern Sweden (geomagnetic latitude of $65^\circ$), for a three
hour flight during which the instrument took data up to an altitude of 30.9 km.
The detector design and ground calibration results are presented together with
the measurement results from the balloon flight.
[19]
oai:arXiv.org:1410.1364 [pdf] - 1555763
A Model of the Cosmic Ray Induced Atmospheric Neutron Environment
Submitted: 2014-10-06
In order to optimise the design of space instruments making use of detection
materials with low atomic numbers, an understanding of the atmospheric neutron
environment and its dependencies on time and position is needed. To produce a
simple equation based model, Monte Carlo simulations were performed to obtain
the atmospheric neutron fluxes produced by charged galactic cosmic ray
interactions with the atmosphere. Based on the simulation results the
omnidirectional neutron environment was parametrised including dependencies on
altitude, magnetic latitude and solar activity. The upward- and downward-moving
component of the atmospheric neutron flux are considered separately. The energy
spectra calculated using these equations were found to be in good agreement
with data from a purpose built balloon-borne neutron detector, high altitude
aircraft data and previously published simulation based spectra.
[20]
oai:arXiv.org:1311.5531 [pdf] - 749865
A Balloon-borne Measurement of High Latitude Atmospheric Neutrons Using
a LiCAF Neutron Detector
Kole, Merlin;
Fukazawa, Yasushi;
Fukuda, Kentaro;
Ishizu, Sumito;
Jackson, Miranda;
Kamae, Tune;
Kawaguchi, Noriaki;
Kawano, Takafumi;
Kiss, Mózsi;
Moretti, Elena;
Salinas, Maria Fernanda Muñoz;
Pearce, Mark;
Rydström, Stefan;
Takahashi, Hiromitsu;
Yanagida, Takayuki
Submitted: 2013-11-21
PoGOLino is a scintillator-based neutron detector. Its main purpose is to
provide data on the neutron flux in the upper stratosphere at high latitudes at
thermal and nonthermal energies for the PoGOLite instrument. PoGOLite is a
balloon borne hard X-ray polarimeter for which the main source of background
stems from high energy neutrons. No measurements of the neutron environment for
the planned flight latitude and altitude exist. Furthermore this neutron
environment changes with altitude, latitude and solar activity, three variables
that will vary throughout the PoGOLite flight. PoGOLino was developed to study
the neutron environment and the influences from these three variables upon it.
PoGOLino consists of two Europium doped Lithium Calcium Aluminium Fluoride
(Eu:LiCAF) scintillators, each of which is sandwiched between 2 Bismuth
Germanium Oxide (BGO) scintillating crystals, which serve to veto signals
produced by gamma-rays and charged particles. This allows the neutron flux to
be measured even in high radiation environments. Measurements of neutrons in
two separate energy bands are achieved by placing one LiCAF detector inside a
moderating polyethylene shield while the second detector remains unshielded.
The PoGOLino instrument was launched on March 20th 2013 from the Esrange Space
Center in Northern Sweden to an altitude of 30.9 km. A description of the
detector design and read-out system is presented. A detailed set of simulations
of the atmospheric neutron environment performed using both PLANETOCOSMICS and
Geant4 will also be described. The comparison of the neutron flux measured
during flight to predictions based on these simulations will be presented and
the consequences for the PoGOLite background will be discussed.
[21]
oai:arXiv.org:1211.5094 [pdf] - 1513465
Balloon-borne hard X-ray polarimetry with PoGOLite
Pearce, Mark;
Florén, Hans-Gustav;
Jackson, Miranda;
Kamae, Tune;
Kiss, Mózsi;
Kole, Merlin;
Moretti, Elena;
Olofsson, Göran;
Rydström, Stefan;
Strömberg, Jan-Erik;
Takahashi, Hiromitsu
Submitted: 2012-11-21, last modified: 2013-03-08
PoGOLite is a hard X-ray polarimeter operating in the 25-100 keV energy band.
The instrument design is optimised for the observation of compact astrophysical
sources. Observations are conducted from a stabilised stratospheric balloon
platform at an altitude of approximately 40 km. The primary targets for first
balloon flights of a reduced effective area instrument are the Crab and
Cygnus-X1. The polarisation of incoming photons is determined using coincident
Compton scattering and photo-absorption events reconstructed in an array of
plastic scintillator detector cells surrounded by a bismuth germanate oxide
(BGO) side anticoincidence shield and a polyethylene neutron shield. A custom
attitude control system keeps the polarimeter field-of-view aligned to targets
of interest, compensating for sidereal motion and perturbations such as
torsional forces in the balloon rigging. An overview of the PoGOLite project is
presented and the outcome of the ill-fated maiden balloon flight is discussed.