Normalized to: Huiting, R.
[1]
oai:arXiv.org:2001.05151 [pdf] - 2050374
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated
Superconducting Spectrometer
Takekoshi, Tatsuya;
Karatsu, Kenichi;
Suzuki, Junya;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Baselmans, Jochem J. A.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Endo, Akira
Submitted: 2020-01-15
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep
Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip
filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate
dusty star-burst galaxies in the distant universe at millimeter and
submillimeter wavelength. An on-site experiment of DESHIMA was performed using
the ASTE 10-m telescope. We established a responsivity model that converts
frequency responses of the MKIDs to line-of-sight brightness temperature. We
estimated two parameters of the responsivity model using a set of skydip data
taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for
each MKID. The line-of-sight brightness temperature of sky is estimated using
an atmospheric transmission model and the PWVs. As a result, we obtain an
average temperature calibration uncertainty of $1\sigma=4$%, which is smaller
than other photometric biases. In addition, the average forward efficiency of
0.88 in our responsivity model is consistent with the value expected from the
geometrical support structure of the telescope. We also estimate line-of-sight
PWVs of each skydip observation using the frequency response of MKIDs, and
confirm the consistency with PWVs reported by the Atacama Large
Millimeter/submillimeter Array.
[2]
oai:arXiv.org:1906.10216 [pdf] - 1963690
First light demonstration of the integrated superconducting spectrometer
Endo, Akira;
Karatsu, Kenichi;
Tamura, Yoichi;
Oshima, Tai;
Taniguchi, Akio;
Takekoshi, Tatsuya;
Asayama, Shin'ichiro;
Bakx, Tom J. L. C.;
Bosma, Sjoerd;
Bueno, Juan;
Chin, Kah Wuy;
Fujii, Yasunori;
Fujita, Kazuyuki;
Huiting, Robert;
Ikarashi, Soh;
Ishida, Tsuyoshi;
Ishii, Shun;
Kawabe, Ryohei;
Klapwijk, Teun M.;
Kohno, Kotaro;
Kouchi, Akira;
Llombart, Nuria;
Maekawa, Jun;
Murugesan, Vignesh;
Nakatsubo, Shunichi;
Naruse, Masato;
Ohtawara, Kazushige;
Laguna, Alejandro Pascual;
Suzuki, Junya;
Suzuki, Koyo;
Thoen, David J.;
Tsukagoshi, Takashi;
Ueda, Tetsutaro;
de Visser, Pieter J.;
van der Werf, Paul P.;
Yates, Stephen J. C.;
Yoshimura, Yuki;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2019-06-24, last modified: 2019-09-18
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter
(mm-submm) band is an essential tool for uncovering the dust-enshrouded portion
of the cosmic history of star formation and galaxy evolution. However, it is
challenging to scale up conventional coherent heterodyne receivers or
free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and
numbers of spatial pixels (>$10^2$). Here we present the design and first
astronomical spectra of an intrinsically scalable, integrated superconducting
spectrometer, which covers 332-377 GHz with a spectral resolution of $F/\Delta
F \sim 380$. It combines the multiplexing advantage of microwave kinetic
inductance detectors (MKIDs) with planar superconducting filters for dispersing
the signal in a single, small superconducting integrated circuit. We
demonstrate the two key applications for an instrument of this type: as an
efficient redshift machine, and as a fast multi-line spectral mapper of
extended areas. The line detection sensitivity is in excellent agreement with
the instrument design and laboratory performance, reaching the atmospheric
foreground photon noise limit on sky. The design can be scaled to bandwidths in
excess of an octave, spectral resolution up to a few thousand and frequencies
up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$
allows for compact multi-pixel spectral imagers, which would enable
spectroscopic direct imaging and large volume spectroscopic surveys that are
several orders of magnitude faster than what is currently possible.
[3]
oai:arXiv.org:1901.06934 [pdf] - 1904696
Wideband on-chip terahertz spectrometer based on a superconducting
filterbank
Endo, Akira;
Karatsu, Kenichi;
Laguna, Alejandro Pascual;
Mirzaei, Behnam;
Huiting, Robert;
Thoen, David J.;
Murugesan, Vignesh;
Yates, Stephen J. C.;
Bueno, Juan;
van Marrewijk, Nuri;
Bosma, Sjoerd;
Yurduseven, Ozan;
Llombart, Nuria;
Suzuki, Junya;
Naruse, Masato;
de Visser, Pieter J.;
van der Werf, Paul P.;
Klapwijk, Teun M.;
Baselmans, Jochem J. A.
Submitted: 2019-01-21, last modified: 2019-06-21
Terahertz spectrometers with a wide instantaneous frequency coverage for
passive remote sensing are enormously attractive for many terahertz
applications, such as astronomy, atmospheric science and security. Here we
demonstrate a wide-band terahertz spectrometer based on a single
superconducting chip. The chip consists of an antenna coupled to a transmission
line filterbank, with a microwave kinetic inductance detector behind each
filter. Using frequency division multiplexing, all detectors are read-out
simultaneously creating a wide-band spectrometer with an instantaneous
bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral
resolution of $F/\Delta F=380$ and reaches photon-noise limited sensitivity. We
discuss the chip design and fabrication, as well as the system integration and
testing. We confirm full system operation by the detection of an emission line
spectrum of methanol gas. The proposed concept allows for spectroscopic
radiation detection over large bandwidths and resolutions up to $F/\Delta
F\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the
construction of medium resolution imaging spectrometers with unprecedented
speed and sensitivity.