Normalized to: Yue, Q.
[1]
oai:arXiv.org:1802.09327 [pdf] - 1770540
Study on cosmogenic activation in germanium detectors for future
tonne-scale CDEX experiment
Ma, J. L.;
Yue, Q.;
Lin, S. T.;
Wong, H. T.;
Hu, J. W.;
Jia, L. P.;
Jiang, H.;
Li, J.;
Liu, S. K.;
Liu, Z. Z.;
Ma, H.;
Tang, W. Y.;
Tian, Y.;
Wang, L.;
Wang, Q.;
Yang, L. T.;
Zeng, Z.
Submitted: 2018-02-26, last modified: 2018-10-20
A study on cosmogenic activation in germanium was carried out to evaluate the
cosmogenic background level of natural and $^{70}$Ge depleted germanium
detectors. The production rates of long-lived radionuclides were calculated
with Geant4 and CRY. Results were validated by comparing the simulated and
experimental spectra of CDEX-1B detector. Based on the validated codes, the
cosmogenic background level was predicted for further tonne-scale CDEX
experiment. The suppression of cosmogenic background level could be achieved by
underground germanium crystal growth and high-purity germanium detector
fabrication to reach the sensitivity requirement for direct detection of dark
matter. With the low cosmogenic background, new physics channels, such as solar
neutrino research and neutrinoless double-beta decay experiments, were opened
and the corresponding simulations and evaluations were carried out.
[2]
oai:arXiv.org:1602.02462 [pdf] - 1426242
The CDEX Dark Matter Program at the China Jinping Underground Laboratory
Submitted: 2016-02-07
The China Jinping Underground Laboratory (CJPL) is a new facility for
conducting low event-rate experiments. We present an overview of CJPL and the
CDEX Dark Matter program based on germanium detectors with sub-keV
sensitivities. The achieved results, status as well as the R&D and technology
acquisition efforts towards a ton-scale experiment are reported.
[3]
oai:arXiv.org:1502.03800 [pdf] - 934951
Measurement of the quenching and channeling effects in a CsI crystal
used for a WIMP search
Lee, J. H.;
Kim, G. B.;
Seong, I. S.;
Kim, B. H.;
Kim, J. H.;
Li, J.;
Park, J. W.;
Lee, J. K.;
Kim, K. W.;
Bhang, H.;
Kim, S. C.;
Choi, Seonho;
Choi, J. H.;
Joo, H. W.;
Lee, S. J.;
Olsen, S. L.;
Myung, S. S.;
Kim, S. K.;
Kim, Y. D.;
Kang, W. G.;
So, J. H.;
Kim, H. J.;
Lee, H. S.;
Hahn, I. S.;
Leonard, D. S.;
Li, J.;
Li, Y. J.;
Yue, Q.;
Li, X. R.
Submitted: 2015-02-12
We have studied channeling effects in a Cesium Iodide (CsI) crystal that is
similar in composition to the ones being used in a search for Weakly
Interacting Massive Particles (WIMPs) dark matter candidates, and measured its
energy-dependent quenching factor, the relative scintillation yield for
electron and nuclear recoils. The experimental results are reproduced with a
GEANT4 simulation that includes a model of the scintillation efficiency as a
function of electronic stopping power. We present the measured and simulated
quenching factors and the estimated effects of channeling.
[4]
oai:arXiv.org:1404.3443 [pdf] - 878004
Search for Low-Mass Dark Matter with CsI(Tl) Crystal Detectors
Lee, H. S.;
Bhang, H.;
Choi, J. H.;
Choi, S.;
Hahn, I. S.;
Jeon, E. J.;
Joo, H. W.;
Kang, W. G.;
Kim, B. H.;
Kim, G. B.;
Kim, H. J.;
Kim, J. H.;
Kim, K. W.;
Kim, S. C.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Lee, J. H.;
Lee, J. K.;
Lee, S. J.;
Leonard, D. S.;
Li, J.;
Li, J.;
Li, Y. J.;
Li, X. R.;
Myung, S. S.;
Olsen, S. L.;
Park, J. W.;
Seong, I. S.;
So, J. H.;
Yue, Q.
Submitted: 2014-04-13, last modified: 2014-10-07
We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting
massive particles(WIMPs), strong candidates of dark matter particles,using the
low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS)
experiment. With a total data exposure of 24,324.3kg$\cdot$days,we search for
WIMP interaction signals produced by nuclei recoiling from WIMP-nuclear elastic
scattering with visible energies between 2 and 4keV. The observed energy
distribution of candidate events is consistent with null signals, and upper
limits of the WIMP-proton spin-independent interaction are set with a 90%
confidence level. The observed limit rejects most of the low mass region of
parameter space favored by the DAMA annual modulation signal.
[5]
oai:arXiv.org:1408.0590 [pdf] - 1500904
Measurement of intrinsic radioactive backgrounds from Cs-137 and U/Th
chains in CsI(Tl) crystals
Liu, S. K.;
Yue, Q.;
Lin, S. T.;
Li, Y. J.;
Tang, C. J.;
Wong, H. T.;
Xing, H. Y.;
Yang, C. W.;
Zhao, W.;
Zhu, J. J.
Submitted: 2014-08-04
The inorganic CsI(Tl) crystal scintillator is a candidate served as an
anti-compton detector for China Dark matter EXperiment (CDEX). Studying the
intrinsic radiopurity of CsI(Tl) crystal is an issue of major importance. The
timing, energy and spatial correlations, as well as the capability of pulse
shape discrimination provide powerful methods for the measurement of intrinsic
radiopurities. The experimental design, detector performance and
event-selection algorithms are described. A total of 359*3 kg-days data from
three prototypes of CsI(Tl) crystals were taken at China Jinping underground
laboratory where offers a good shielding environment. The contamination levels
of internal isotopes from Cs-137, Th-232 and U-238 series, as well as the upper
bounds of U-235 series are reported. Identification of the whole alpha8 peaks
from U/Th decay chains and derivation of those corresponding quenching factors
are achieved.
[6]
oai:arXiv.org:1403.5421 [pdf] - 862588
Limits on light WIMPs with a germanium detector at 177 eVee threshold at
the China Jinping Underground Laboratory
Liu, S. K.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Wong, H. T.;
Li, Y. J.;
Lin, S. T.;
Chang, J. P.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Q.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Lü, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wu, S. Y.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xiao, R. Q.;
Xing, H. Y.;
Xu, F. Z.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, C. W.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhao, W.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2014-03-21, last modified: 2014-08-01
The China Dark Matter Experiment reports results on light WIMP dark matter
searches at the China Jinping Underground Laboratory with a germanium detector
array with a total mass of 20 g. The physics threshold achieved is 177 eVee
("ee" represents electron equivalent energy) at 50% signal efficiency. With
0.784 kg-days of data, exclusion region on spin-independent coupling with the
nucleon is derived, improving over our earlier bounds at WIMP mass less than
4.6 GeV.
[7]
oai:arXiv.org:1306.4135 [pdf] - 719413
First results on low-mass WIMP from the CDEX-1 experiment at the China
Jinping underground Laboratory
Zhao, W.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Li, Y. J.;
Lin, S. T.;
Bai, Y.;
Bi, Y.;
Chang, J. P.;
Chen, N.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, C.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Hu, X. H.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Liu, S. K.;
Lv, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wong, H. T.;
Wu, S. Y.;
Wu, W.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xing, H. Y.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhong, S. N.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2013-06-18, last modified: 2013-08-08
The China Dark matter Experiment collaboration reports the first experimental
limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type
point-contact germanium detector at the China Jinping underground Laboratory
where the rock overburden is more than 2400 m. The energy threshold achieved
was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N=
1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent
cross-section at WIMP mass of 7 GeV before differentiating bulk signals from
the surface backgrounds.
[8]
oai:arXiv.org:1305.0899 [pdf] - 1166417
Measurement of Cosmic Ray Flux in China JinPing underground Laboratory
Wu, Yu-Cheng;
Hao, Xi-Qing;
Yue, Qian;
LI, Yuan-Jing;
Cheng, Jian-Ping;
Kang, Ke-Jun;
Chen, Yun-Hua;
Li, Jin;
Li, Jian-Min;
Li, Yu-Lan;
Liu, Shu-Kui;
Ma, Hao;
Ren, Jin-Bao;
Shen, Man-Bin;
Wang, Ji-Min;
Wu, Shi-Yong;
Xue, Tao;
YI, Nan;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhu, Zhong-Hua
Submitted: 2013-05-04
China JinPing underground Laboratory (CJPL) is the deepest underground
laboratory presently running in the world. In such a deep underground
laboratory, the cosmic ray flux is a very important and necessary parameter for
rare event experiments. A plastic scintillator telescope system has been set up
to measure the cosmic ray flux. The performance of the telescope system has
been studied using the cosmic ray on the ground laboratory near CJPL. Based on
the underground experimental data taken from November 2010 to December 2011 in
CJPL, which has effective live time of 171 days, the cosmic ray muon flux in
CJPL is measured to be (2.0+-0.4)*10^(-10)/(cm^2)/(s). The ultra-low cosmic ray
background guarantees CJPL's ideal environment for dark matter experiment.
[9]
oai:arXiv.org:1305.0401 [pdf] - 1166364
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark
Matter Searches
Kang, Ke-Jun;
Yue, Qian;
Wu, Yu-Cheng;
Cheng, Jian-Ping;
Li, Yuan-Jing;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Chuang, You-Chun;
Dend, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Huang, Teng-Rui;
Jiang, Hao;
Li, Hau-Bin;
Li, Jian-Min;
Li, Jin;
Li, Jun;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liao, Heng-Ye;
Lin, Fong-Kay;
Lin, Shin-Ted;
Liu, Shu-Kui;
Lv, Lan-Chun;
Ma, Hao;
Mao, Shao-Ji;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Singh, Lakhwinder;
Singh, Manoj Kumar;
Soma, Arun Kumar;
Su, Jian;
Tang, Chang-Jian;
Tseng, Chao-Hsiung;
Wang, Ji-Min;
Wang, Li;
Wang, Qing;
Wong, Tsz-King Henry;
Wu, Shi-Yong;
Wu, Wei;
Wu, Yu-Cheng;
Xing, Hao-Yang;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yang, Song-Wei;
Yi, Nan;
Yu, Chun-Xu;
Yu, Hao;
Yu, Xun-Zhen;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Yun-Hua;
Zhao, Ming-Gang;
Zhao, Wei;
Zhong, Su-Ning;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-05-02
The CDEX Collaboration has been established for direct detection of light
dark matter particles, using ultra-low energy threshold p-type point-contact
germanium detectors, in China JinPing underground Laboratory (CJPL). The first
1 kg point-contact germanium detector with a sub-keV energy threshold has been
tested in a passive shielding system located in CJPL. The outputs from both the
point-contact p+ electrode and the outside n+ electrode make it possible to
scan the lower energy range of less than 1 keV and at the same time to detect
the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode
may also provide a more powerful method for signal discrimination for dark
matter experiment. Some key parameters, including energy resolution, dead time,
decay times of internal X-rays, and system stability, have been tested and
measured. The results show that the 1 kg point-contact germanium detector,
together with its shielding system and electronics, can run smoothly with good
performances. This detector system will be deployed for dark matter search
experiments.
[10]
oai:arXiv.org:1303.0601 [pdf] - 813786
Introduction of the CDEX experiment
Kang, Ke-Jun;
Cheng, Jian-Ping;
Li, Jin;
Li, Yuan-Jing;
Yue, Qian;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Deng, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Hong-Jian;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Jiang, Hao;
Li, Jian-Min;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liu, Shu-Kui;
Liu, Ya-Bin;
Lu, Lan-Chun;
Ma, Hao;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Su, Jian;
Tang, Chang-Jian;
Tang, Zhen-Yu;
Wang, Ji-Min;
Wang, Qing;
Wang, Xu-Feng;
Wu, Shi-Yong;
Wu, Yu-Cheng;
Xianyu, Zhong-Zhi;
Xing, Hao-Yang;
Xu, Xun-Jie;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yi, Nan;
Yu, Hao;
Yu, Chun-Xu;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Guang-Hua;
Zhao, Ming-Gang;
Zhong, Su-Ning;
Zhou, Jin;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-03-03
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark
matter in our universe. Up to now any direct interaction of WIMP with nuclei
has not been observed yet. The exclusion limits of the spin-independent cross
section of WIMP-nucleon which have been experimentally obtained is about
10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China
Jin-Ping underground laboratory CJPL is the deepest underground lab in the
world and provides a very promising environment for direct observation of dark
matter. The China Dark Matter Experiment (CDEX) experiment is going to directly
detect the WIMP flux with high sensitivity in the low mass region. Both CJPL
and CDEX have achieved a remarkable progress in recent two years. The CDEX
employs a point-contact germanium semi-conductor detector PCGe whose detection
threshold is less than 300 eV. We report the measurement results of Muon flux,
monitoring of radioactivity and Radon concentration carried out in CJPL, as
well describe the structure and performance of the 1 kg PCGe detector CDEX-1
and 10kg detector array CDEX-10 including the detectors, electronics, shielding
and cooling systems. Finally we discuss the physics goals of the CDEX-1,
CDEX-10 and the future CDEX-1T detectors.
[11]
oai:arXiv.org:1108.4353 [pdf] - 554956
Low energy fast events from radon progenies at the surface of a CsI(Tl)
scintillator
Kim, S. C.;
Bhang, H.;
Choi, J. H.;
Kang, W. G.;
Kim, H. J.;
Kim, K. W.;
Kim, S. K.;
Kim, Y. D.;
Lee, H. S.;
Lee, J. I.;
Lee, J. H.;
Lee, J. K.;
Lee, M. J.;
Lee, S. J.;
Li, J.;
Li, J.;
Li, Y. J.;
Li, X.;
Myung, S. S.;
Olsen, S. L.;
Ryu, S.;
Seong, I. S.;
So, J. H.;
Yue, Q.
Submitted: 2011-08-22, last modified: 2012-08-27
In searches for rare phenomena such as elastic scattering of dark matter
particles or neutrinoless double beta decay, alpha decays of Rn222 progenies
attached to the surfaces of the detection material have been identified as a
serious source of background. In measurements with CsI(Tl) scintillator
crystals, we demonstrate that alpha decays of surface contaminants produce fast
signals with a characteristic mean-time distribution that is distinct from
those of neutron- and gamma-induced events.
[12]
oai:arXiv.org:1204.2646 [pdf] - 510346
New Limits on Interactions between Weakly Interacting Massive Particles
and Nucleons Obtained with CsI(Tl) Crystal Detectors
Kim, S. C.;
Bhang, H.;
Choi, J. H.;
Kang, W. G.;
Kim, B. H.;
Kim, H. J.;
Kim, K. W.;
Kim, S. K.;
Kim, Y. D.;
Lee, J.;
Lee, J. H.;
Lee, J. K.;
Lee, M. J.;
Lee, S. J.;
Li, J.;
Li, J.;
Li, X. R.;
Li, Y. J.;
Myung, S. S.;
Olsen, S. L.;
Ryu, S.;
Seong, I. S.;
So, J. H.;
Yue, Q.
Submitted: 2012-04-12, last modified: 2012-05-09
New limits are presented on the cross section for Weakly Interacting Massive
Particle (WIMP) nucleon scattering in the KIMS CsI(T) detector array at the
Yangyang Underground Laboratory. The exposure used for these results is 24524.3
kg\cdotdays. Nuclei recoiling from WIMP interactions are identified by a pulse
shape discrimination method. A low energy background due to alpha emitters on
the crystal surfaces is identified and taken into account in the analysis. The
detected numbers of nuclear recoils are consistent with zero and 90% confidence
level upper limits on the WIMP interaction rates are set for electron
equivalent energies from 3 keV to 11 keV. The 90% upper limit of NR event rate
for 3.6-5.8 keV corresponding to 2-4 keV in NaI(T) is 0.0098 counts/kg/keV/day
which is below the annual modulation amplitude reported by DAMA. This is
incompatible with interpretations that enhance the modulation amplitude such as
inelastic dark matter models. We establish the most stringent cross section
limits on spin-dependent WIMP-proton elastic scattering for the WIMP masses
greater than 20 GeV/c2.
[13]
oai:arXiv.org:1201.5373 [pdf] - 1937763
Dark Matter Search with sub-keV Germanium Detectors at the China Jinping
Underground Laboratory
Submitted: 2012-01-25
Germanium detectors with sub-keV sensitivities open a window to search for
low-mass WIMP dark matter. The CDEX-TEXONO Collaboration is conducting the
first research program at the new China Jinping Underground Laboratory with
this approach. The status and plans of the laboratory and the experiment are
discussed.
[14]
oai:arXiv.org:0704.0423 [pdf] - 166645
Limits on WIMP-nucleon interactions with CsI(Tl) crystal detectors
Lee, H. S.;
Bhang, H. C.;
Choi, J. H.;
Dao, H.;
Hahn, I. S.;
Hwang, M. J.;
Jung, S. W.;
Kang, W. G.;
Kim, D. W.;
Kim, H. J.;
Kim, S. C.;
Kim, S. K.;
Kim, Y. D.;
Kwak, J. W.;
Kwon, Y. J.;
Lee, J.;
Lee, J. H.;
Lee, J. I.;
Lee, M. J.;
Lee, S. J.;
Li, J.;
Li, X.;
Li, Y. J.;
Myung, S. S.;
Ryu, S.;
So, J. H.;
Yue, Q.;
Zhu, J. J.
Submitted: 2007-04-03, last modified: 2007-08-14
The Korea Invisible Mass Search(KIMS) experiment presents new limits on
WIMP-nucleon cross section using the data from an exposure of 3409 kgd taken
with low background CsI(Tl) crystals at Yangyang underground laboratory. The
most stringent limit on the spin dependent interaction for pure proton case is
obtained. The DAMA signal region for both spin independent and spin dependent
interactions for the WIMP mass higher than 20 GeV/c^2are excluded by the single
experiment with crystal scintillators.