sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Yoneyama, Tomokage

Normalized to: Yoneyama, T.

5 article(s) in total. 39 co-authors, from 1 to 5 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:2007.04465  [pdf] - 2131627
Discovery of a transient X-ray source Suzaku J1305-4930 in NGC 4945
Comments: 17 pages, 10 figures
Submitted: 2020-07-08
We report the serendipitous discovery of a transient X-ray source, Suzaku J1305$-$4930, $\sim$3 kpc southwest of the nucleus of the Seyfert 2 galaxy NGC 4945. Among the seven Suzaku observations of NGC 4945 from 2005 to 2011, Suzaku J1305$-$4930 was detected four times in July and August in 2010. The X-ray spectra are better approximated with a multi-color disk model than a power-law model. At the first detection on 2010 July 4--5, its X-ray luminosity was $(8.9^{+0.2}_{-0.4}) \times 10^{38}$ erg s$^{-1}$ and the temperature at the inner-disk radius ($kT_{\rm in}$) was $1.12\pm0.04$ keV. At the last detection with Suzaku on 2010 August 4--5, the luminosity decreased to $(2.2^{+0.3}_{-0.8}) \times10^{38}$ erg s$^{-1}$ and $kT_{\rm in}$ was $0.62\pm0.07$ keV. The source was not detected on 2011 January 29, about six months after the first detection, with a luminosity upper limit of $2.4\times10^{38}$ erg s$^{-1}$. We also find an absorption feature which is similar to that reported in Cyg X-1. Assuming the standard disk, we suggest that Suzaku J1305$-$4930 consists of a black hole with a mass of $\sim$10 $M_{\odot}$. The relation between the disk luminosity and $kT_{\rm in}$ is not reproduced with the standard model of a constant inner radius but is better approximated with a slim-disk model.
[2]  oai:arXiv.org:1906.00171  [pdf] - 1893553
Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite
Comments: 10 pages, 6 figures, published in Journal of Instrumentation (JINST)
Submitted: 2019-06-01
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.
[3]  oai:arXiv.org:1906.00012  [pdf] - 1893538
X-ray imaging polarimetry with a 2.5-$\mathrm{\mu}$m pixel CMOS sensor for visible light at room temperature
Comments: 13 pages, 8 figures, 1 table, accepted for publication in JATIS
Submitted: 2019-05-31
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc., and has a pixel size of 2.5 $\mathrm{\mu}$m $\times$ 2.5 $\mathrm{\mu}$m. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63% $\pm$ 0.07% and 15.5% $\pm$ 0.4% at 12.4 keV and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.
[4]  oai:arXiv.org:1811.11982  [pdf] - 1791760
Universal detection of high-temperature emission in X-ray Isolated Neutron Stars
Comments:
Submitted: 2018-11-29
Strongly magnetized isolated neutron stars (NSs) are categorized into two families, according mainly to their magnetic field strength. The one with a higher magnetic field of $10^{14}$ - $10^{15}$ G is called magnetar, characterized with repeated short bursts, and the other is X-ray isolated neutron star (XINS) with $10^{13}$ G. Both magnetars and XINSs show thermal emission in X-rays, but it has been considered that the thermal spectrum of magnetars is reproduced with a two-temperature blackbody (2BB), while that of XINSs shows only a single-temperature blackbody (1BB) and the temperature is lower than that of magnetars. On the basis of the magnetic field and temperature, it is often speculated that XINSs may be old and cooled magnetars. Here we report that all the seven known XINSs show a high-energy component in addition to the 1BB model. Analyzing all the XMM-Newton data of the XINSs with the highest statistics ever achieved, we find that their X-ray spectra are all reproduced with a 2BB model, similar to magnetars. Their emission radii and temperature ratios are also similar to those of magnetars except for two XINSs, which show significantly smaller radii than the others. The remarkable similarity in the X-ray spectra between XINSs and magnetars suggests that their origins of the emission are also the same. The lower temperature in XINSs can be explained if XINSs are older than magnetars. Therefore, these results are the observational indication that supports the standard hypothesis on the classification of highly-magnetized NSs.
[5]  oai:arXiv.org:1703.05995  [pdf] - 1581980
Discovery of a keV-X-ray Excess in RX J1856.5--3754
Comments:
Submitted: 2017-03-17
RX J1856.5$-$3754 is the brightest and nearest ($\sim 120$ pc) source among thermally emitting isolated neutron stars. Its spectra observed with {\sl XMM-Newton} and {\sl Chandra} satellites are well-fitted with the two-temperature ($kT^\infty \sim$ 32 and 63 eV) blackbody model. Fitting ten sets of the data from {\sl Suzaku} XIS0, XIS1, XIS3 and {\sl XMM-Newton} EPIC-pn with the two-temperature blackbody model, we discover an excess emission, 16--26\% in 0.8--1.2\,keV. We examine possible causes of this keV-X-ray excess; uncertainty in the background, pile up of the low energy photons and confusion of other sources. None of them succeeds in explaining the keV-X-ray excess observed with different instruments. We thus consider this keV-X-ray excess is most likely originated in RX J1856.5$-$3754. However, it is difficult to constrain the spectral shape of the keV-X-ray excess. The third blackbody component with $kT^\infty = 137^{+18}_{-14}$ eV, additional power-law component with a photon index $\Gamma = 3.4^{+0.5}_{-0.6}$, or Comptonization of blackbody seed photons into power-law with a photon index $\Gamma_c = 4.3^{+0.8}_{-0.8}$ can reproduce the keV-X-ray excess. We also search for the periodicity of 0.8--1.2\,keV data, since 7.055 s pulsation is discovered from 0.15--1.2\,keV band in the XMM Newton EPIC-pn data ($\sim$1.5\%). We only obtain the upper limit of pulsed fraction $<$ 3\% in the keV-X-ray excess. We shortly discuss the possible origin of the keV-X-ray excess, such as synchrotron radiation and Comptonization of blackbody photons.