sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Yamamoto, A.

Normalized to: Yamamoto, A.

31 article(s) in total. 344 co-authors, from 1 to 23 common article(s). Median position in authors list is 23,0.

[1]  oai:arXiv.org:1908.03013  [pdf] - 2105542
Application of the independent component analysis to the iKAGRA data
KAGRA Collaboration; Akutsu, T.; Ando, M.; Arai, K.; Arai, Y.; Araki, S.; Araya, A.; Aritomi, N.; Asada, H.; Aso, Y.; Atsuta, S.; Awai, K.; Bae, S.; Bae, Y.; Baiotti, L.; Bajpai, R.; Barton, M. A.; Cannon, K.; Capocasa, E.; Chan, M.; Chen, C.; Chen, K.; Chen, Y.; Chu, H.; Chu, Y-K.; Craig, K.; Creus, W.; Doi, K.; Eda, K.; Eguchi, S.; Enomoto, Y.; Flaminio, R.; Fujii, Y.; Fujimoto, M. -K.; Fukunaga, M.; Fukushima, M.; Furuhata, T.; Ge, G.; Hagiwara, A.; Haino, S.; Hasegawa, K.; Hashino, K.; Hayakawa, H.; Hayama, K.; Himemoto, Y.; Hiranuma, Y.; Hirata, N.; Hirobayashi, S.; Hirose, E.; Hong, Z.; Hsieh, B. H.; Huang, G-Z.; Huang, P.; Huang, Y.; Ikenoue, B.; Imam, S.; Inayoshi, K.; Inoue, Y.; Ioka, K.; Itoh, Y.; Izumi, K.; Jung, K.; Jung, P.; Kaji, T.; Kajita, T.; Kakizaki, M.; Kamiizumi, M.; Kanbara, S.; Kanda, N.; Kanemura, S.; Kaneyama, M.; Kang, G.; Kasuya, J.; Kataoka, Y.; Kawaguchi, K.; Kawai, N.; Kawamura, S.; Kawasaki, T.; Kim, C.; Kim, J. C.; Kim, W. S.; Kim, Y. -M.; Kimura, N.; Kinugawa, T.; Kirii, S.; Kita, N.; Kitaoka, Y.; Kitazawa, H.; Kojima, Y.; Kokeyama, K.; Komori, K.; Kong, A. K. H.; Kotake, K.; Kozakai, C.; Kozu, R.; Kumar, R.; Kume, J.; Kuo, C.; Kuo, H-S.; Kuroyanagi, S.; Kusayanagi, K.; Kwak, K.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Lee, R.; Leonardi, M.; Lin, C.; Lin, C-Y.; Lin, F-L.; Liu, G. C.; Liu, Y.; Luo, L.; Majorana, E.; Mano, S.; Marchio, M.; Matsui, T.; Matsushima, F.; Michimura, Y.; Mio, N.; Miyakawa, O.; Miyamoto, A.; Miyamoto, T.; Miyazaki, Y.; Miyo, K.; Miyoki, S.; Morii, W.; Morisaki, S.; Moriwaki, Y.; Morozumi, T.; Musha, M.; Nagano, K.; Nagano, S.; Nakamura, K.; Nakamura, T.; Nakano, H.; Nakano, M.; Nakao, K.; Nakashima, R.; Narikawa, T.; Naticchioni, L.; Negishi, R.; Quynh, L. Nguyen; Ni, W. -T.; Nishizawa, A.; Obuchi, Y.; Ochi, T.; Ogaki, W.; Oh, J. J.; Oh, S. H.; Ohashi, M.; Ohishi, N.; Ohkawa, M.; Okutomi, K.; Oohara, K.; Ooi, C. P.; Oshino, S.; Pan, K.; Pang, H.; Park, J.; Arellano, F. E. Pena; Pinto, I.; Sago, N.; Saijo, M.; Saito, S.; Saito, Y.; Sakai, K.; Sakai, Y.; Sakai, Y.; Sakuno, Y.; Sasaki, M.; Sasaki, Y.; Sato, S.; Sato, T.; Sawada, T.; Sekiguchi, T.; Sekiguchi, Y.; Seto, N.; Shibagaki, S.; Shibata, M.; Shimizu, R.; Shimoda, T.; Shimode, K.; Shinkai, H.; Shishido, T.; Shoda, A.; Somiya, K.; Son, E. J.; Sotani, H.; Suemasa, A.; Sugimoto, R.; Suzuki, T.; Suzuki, T.; Tagoshi, H.; Takahashi, H.; Takahashi, R.; Takamori, A.; Takano, S.; Takeda, H.; Takeda, M.; Tanaka, H.; Tanaka, K.; Tanaka, K.; Tanaka, T.; Tanaka, T.; Tanioka, S.; Martin, E. N. Tapia San; Tatsumi, D.; Telada, S.; Tomaru, T.; Tomigami, Y.; Tomura, T.; Travasso, F.; Trozzo, L.; Tsang, T.; Tsubono, K.; Tsuchida, S.; Tsuzuki, T.; Tuyenbayev, D.; Uchikata, N.; Uchiyama, T.; Ueda, A.; Uehara, T.; Ueki, S.; Ueno, K.; Ueshima, G.; Uraguchi, F.; Ushiba, T.; van Putten, M. H. P. M.; Vocca, H.; Wada, S.; Wakamatsu, T.; Wang, J.; Wu, C.; Wu, H.; Wu, S.; Xu, W-R.; Yamada, T.; Yamamoto, A.; Yamamoto, K.; Yamamoto, K.; Yamamoto, S.; Yamamoto, T.; Yokogawa, K.; Yokoyama, J.; Yokozawa, T.; Yoon, T. H.; Yoshioka, T.; Yuzurihara, H.; Zeidler, S.; Zhao, Y.; Zhu, Z. -H.
Comments: 27 pages, 12 figures : published in PTEP with added discussion about the relation between ICA and Wiener filtering
Submitted: 2019-08-08, last modified: 2020-06-01
We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, and calculate the correlations between the gravitational wave strain channel and 35 physical environmental channels. Using a couple of seismic channels which are found to be strongly correlated with the strain, we perform ICA. Injecting a sinusoidal continuous signal in the strain channel, we find that ICA recovers correct parameters with enhanced signal-to-noise ratio, which demonstrates usefulness of this method. Among the two implementations of ICA used here, we find the correlation method yields the optimal result for the case environmental noises act on the strain channel linearly.
[2]  oai:arXiv.org:1901.03569  [pdf] - 1979528
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
KAGRA Collaboration; Akutsu, T.; Ando, M.; Arai, K.; Arai, Y.; Araki, S.; Araya, A.; Aritomi, N.; Asada, H.; Aso, Y.; Atsuta, S.; Awai, K.; Bae, S.; Baiotti, L.; Barton, M. A.; Cannon, K.; Capocasa, E.; Chen, C-S.; Chiu, T-W.; Cho, K.; Chu, Y-K.; Craig, K.; Creus, W.; Doi, K.; Eda, K.; Enomoto, Y.; Flaminio, R.; Fujii, Y.; Fujimoto, M. -K.; Fukunaga, M.; Fukushima, M.; Furuhata, T.; Hagiwara, A.; Haino, S.; Hasegawa, K.; Hashino, K.; Hayama, K.; Hirobayashi, S.; Hirose, E.; Hsieh, B. H.; Huang, C-Z.; Ikenoue, B.; Inoue, Y.; Ioka, K.; Itoh, Y.; Izumi, K.; Kaji, T.; Kajita, T.; Kakizaki, M.; Kamiizumi, M.; Kanbara, S.; Kanda, N.; Kanemura, S.; Kaneyama, M.; Kang, G.; Kasuya, J.; Kataoka, Y.; Kawai, N.; Kawamura, S.; Kawasaki, T.; Kim, C.; Kim, J.; Kim, J. C.; Kim, W. S.; Kim, Y. -M.; Kimura, N.; Kinugawa, T.; Kirii, S.; Kitaoka, Y.; Kitazawa, H.; Kojima, Y.; Kokeyama, K.; Komori, K.; Kong, A. K. H.; Kotake, K.; Kozu, R.; Kumar, R.; Kuo, H-S.; Kuroyanagi, S.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Leonardi, M.; Lin, C-Y.; Lin, F-L.; Liu, G. C.; Liu, Y.; Majorana, E.; Mano, S.; Marchio, M.; Matsui, T.; Matsushima, F.; Michimura, Y.; Mio, N.; Miyakawa, O.; Miyamoto, A.; Miyamoto, T.; Miyo, K.; Miyoki, S.; Morii, W.; Morisaki, S.; Moriwaki, Y.; Morozumi, T.; Murakami, I.; Musha, M.; Nagano, K.; Nagano, S.; Nakamura, K.; Nakamura, T.; Nakano, H.; Nakano, M.; Nakao, K.; Namai, Y.; Narikawa, T.; Naticchioni, L.; Quynh, L. Nguyen; Ni, W. -T.; Nishizawa, A.; Obuchi, Y.; Ochi, T.; Oh, J. J.; Oh, S. H.; Ohashi, M.; Ohishi, N.; Ohkawa, M.; Okutomi, K.; Ono, K.; Oohara, K.; Ooi, C. P.; Pan, S-S.; Park, J.; Arellano, F. E. Peña; Pinto, I.; Sago, N.; Saijo, M.; Saito, Y.; Saitou, S.; Sakai, K.; Sakai, Y.; Sakai, Y.; Sasai, M.; Sasaki, M.; Sasaki, Y.; Sato, N.; Sato, S.; Sato, T.; Sekiguchi, Y.; Seto, N.; Shibata, M.; Shimoda, T.; Shinkai, H.; Shishido, T.; Shoda, A.; Somiya, K.; Son, E. J.; Suemasa, A.; Suzuki, T.; Suzuki, T.; Tagoshi, H.; Tahara, H.; Takahashi, H.; Takahashi, R.; Takamori, A.; Takeda, H.; Tanaka, H.; Tanaka, K.; Tanaka, T.; Tanioka, S.; Martin, E. N. Tapia San; Tatsumi, D.; Terashima, S.; Tomaru, T.; Tomura, T.; Travasso, F.; Tsubono, K.; Tsuchida, S.; Uchikata, N.; Uchiyama, T.; Ueda, A.; Uehara, T.; Ueki, S.; Ueno, K.; Uraguchi, F.; Ushiba, T.; van Putten, M. H. P. M.; Vocca, H.; Wada, S.; Wakamatsu, T.; Watanabe, Y.; Xu, W-R.; Yamada, T.; Yamamoto, A.; Yamamoto, K.; Yamamoto, K.; Yamamoto, S.; Yamamoto, T.; Yokogawa, K.; Yokoyama, J.; Yokozawa, T.; Yoon, T. H.; Yoshioka, T.; Yuzurihara, H.; Zeidler, S.; Zhu, Z. -H.
Comments: 23 pages, 11 figures
Submitted: 2019-01-11
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
[3]  oai:arXiv.org:1811.08079  [pdf] - 1979518
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Akutsu, T.; Ando, M.; Arai, K.; Arai, Y.; Araki, S.; Araya, A.; Aritomi, N.; Asada, H.; Aso, Y.; Atsuta, S.; Awai, K.; Bae, S.; Baiotti, L.; Barton, M. A.; Cannon, K.; Capocasa, E.; Chen, C-S.; Chiu, T-W.; Cho, K.; Chu, Y-K.; Craig, K.; Creus, W.; Doi, K.; Eda, K.; Enomoto, Y.; Flaminio, R.; Fujii, Y.; Fujimoto, M. -K.; Fukunaga, M.; Fukushima, M.; Furuhata, T.; Haino, S.; Hasegawa, K.; Hashino, K.; Hayama, K.; Hirobayashi, S.; Hirose, E.; Hsieh, B. H.; Huang, C-Z.; Ikenoue, B.; Inoue, Y.; Ioka, K.; Itoh, Y.; Izumi, K.; Kaji, T.; Kajita, T.; Kakizaki, M.; Kamiizumi, M.; Kanbara, S.; Kanda, N.; Kanemura, S.; Kaneyama, M.; Kang, G.; Kasuya, J.; Kataoka, Y.; Kawai, N.; Kawamura, S.; Kawasaki, T.; Kim, C.; Kim, J.; Kim, J. C.; Kim, W. S.; Kim, Y. -M.; Kimura, N.; Kinugawa, T.; Kirii, S.; Kitaoka, Y.; Kitazawa, H.; Kojima, Y.; Kokeyama, K.; Komori, K.; Kong, A. K. H.; Kotake, K.; Kozu, R.; Kumar, R.; Kuo, H-S.; Kuroyanagi, S.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Leonardi, M.; Lin, C-Y.; Lin, F-L.; Liu, G. C.; Liu, Y.; Majorana, E.; Mano, S.; Marchio, M.; Matsui, T.; Matsushima, F.; Michimura, Y.; Mio, N.; Miyakawa, O.; Miyamoto, A.; Miyamoto, T.; Miyo, K.; Miyoki, S.; Morii, W.; Morisaki, S.; Moriwaki, Y.; Morozumi, T.; Musha, M.; Nagano, K.; Nagano, S.; Nakamura, K.; Nakamura, T.; Nakano, H.; Nakano, M.; Nakao, K.; Narikawa, T.; Naticchioni, L.; Quynh, L. Nguyen; Ni, W. -T.; Nishizawa, A.; Ochi, T.; Oh, J. J.; Oh, S. H.; Ohashi, M.; Ohishi, N.; Ohkawa, M.; Okutomi, K.; Ono, K.; Oohara, K.; Ooi, C. P.; Pan, S-S.; Park, J.; Arellano, F. E. Peña; Pinto, I.; Sago, N.; Saijo, M.; Saito, Y.; Sakai, K.; Sakai, Y.; Sakai, Y.; Sasai, M.; Sasaki, M.; Sasaki, Y.; Sato, S.; Sato, T.; Sekiguchi, Y.; Seto, N.; Shibata, M.; Shimoda, T.; Shinkai, H.; Shishido, T.; Shoda, A.; Somiya, K.; Son, E. J.; Suemasa, A.; Suzuki, T.; Suzuki, T.; Tagoshi, H.; Tahara, H.; Takahashi, H.; Takahashi, R.; Takamori, A.; Takeda, H.; Tanaka, H.; Tanaka, K.; Tanaka, T.; Tanioka, S.; Martin, E. N. Tapia San; Tatsumi, D.; Tomaru, T.; Tomura, T.; Travasso, F.; Tsubono, K.; Tsuchida, S.; Uchikata, N.; Uchiyama, T.; Uehara, T.; Ueki, S.; Ueno, K.; Ushiba, T.; van Putten, M. H. P. M.; Vocca, H.; Wada, S.; Wakamatsu, T.; Watanabe, Y.; Xu, W-R.; Yamada, T.; Yamamoto, A.; Yamamoto, K.; Yamamoto, K.; Yamamoto, S.; Yamamoto, T.; Yokogawa, K.; Yokoyama, J.; Yokozawa, T.; Yoon, T. H.; Yoshioka, T.; Yuzurihara, H.; Zeidler, S.; Zhu, Z. -H.
Comments: 6 pages, 3 figures (quality of some figures has been reduced)
Submitted: 2018-11-20
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
[4]  oai:arXiv.org:1710.04823  [pdf] - 2104587
The status of KAGRA underground cryogenic gravitational wave telescope
KAGRA Collaboration; Akutsu, T.; Ando, M.; Araya, A.; Aritomi, N.; Asada, H.; Aso, Y.; Atsuta, S.; Awai, K.; Barton, M. A.; Cannon, K.; Craig, K.; Creus, W.; Doi, K.; Eda, K.; Enomoto, Y.; Flaminio, R.; Fujii, Y.; Fujimoto, M. -K.; Furuhata, T.; Haino, S.; Hasegawa, K.; Hashino, K.; Hayama, K.; Hirobayashi, S.; Hirose, E.; Hsieh, B. H.; Inoue, Y.; Ioka, K.; Itoh, Y.; Kaji, T.; Kajita, T.; Kakizaki, M.; Kamiizumi, M.; Kambara, S.; Kanda, N.; Kanemura, S.; Kaneyama, M.; Kang, G.; Kasuya, J.; Kataoka, Y.; Kawai, N.; Kawamura, S.; Kim, C.; Kim, H.; Kim, J.; Kim, Y.; Kimura, N.; Kinugawa, T.; Kirii, S.; Kitaoka, Y.; Kojima, Y.; Kokeyama, K.; Komori, K.; Kotake, K.; Kumar, R.; Lee, H.; Lee, H.; Liu, Y.; Luca, N.; Majorana, E.; Mano, S.; Marchio, M.; Matsui, T.; Matsushima, F.; Michimura, Y.; Miyakawa, O.; Miyamoto, T.; Miyamoto, A.; Miyo, K.; Miyoki, S.; Morii, W.; Morisaki, S.; Moriwaki, Y.; Morozumi, T.; Musha, M.; Nagano, S.; Nagano, K.; Nakamura, K.; Nakamura, T.; Nakano, H.; Nakano, M.; Nakao, K.; Narikawa, T.; Quynh, L. Nguyen; Ni, W. -T.; Ochi, T.; Oh, J.; Oh, S.; Ohashi, M.; Ohishi, N.; Ohkawa, M.; Okutomi, K.; Oohara, K.; Alleano, F. E. Peña; Pinto, I.; Sago, N.; Saijo, M.; Saito, Y.; Sakai, K.; Sakai, Y.; Sasaki, Y.; Sasaki, M.; Sato, S.; Sato, T.; Sekiguchi, Y.; Seto, N.; Shibata, M.; Shimoda, T.; Shinkai, H.; Shoda, A.; Somiya, K.; Son, E.; Suemasa, A.; Suzuki, T.; Suzuki, T.; Tagoshi, H.; Takahashi, H.; Takahashi, R.; Takamori, A.; Takeda, H.; Tanaka, H.; Tanaka, K.; Tanaka, T.; Tatsumi, D.; Tomaru, T.; Tomura, T.; Travasso, F.; Tsubono, K.; Tsuchida, S.; Uchikata, N.; Uchiyama, T.; Uehara, T.; Ueki, S.; Ueno, K.; Ushiba, T.; van Putten, M. H. P. M.; Vocca, H.; Wada, S.; Wakamatsu, T.; Yamada, T.; Yamamoto, S.; Yamamoto, T.; Yamamoto, K.; Yamamoto, A.; Yokoyama, J.; Yokozawa, T.; Yoon, T. H.; Yuzurihara, H.; Zeidler, S.; Zhu, Z. -H.
Comments: 7 pages, 2 figures. Proceedings for XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017), Sudbury, July 24-28, 2017
Submitted: 2017-10-13
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
[5]  oai:arXiv.org:1506.01267  [pdf] - 1470531
Measurements of cosmic-ray proton and helium spectra from the BESS-Polar long-duration balloon flights over Antarctica
Comments: 23 pages, 11 figures, Accepted for publication in The Astrophysical Journal
Submitted: 2015-06-03, last modified: 2016-08-30
The BESS-Polar Collaboration measured the energy spectra of cosmic-ray protons and helium during two long-duration balloon flights over Antarctica in December 2004 and December 2007, at substantially different levels of solar modulation. Proton and helium spectra probe the origin and propagation history of cosmic rays in the galaxy, and are essential to calculations of the expected spectra of cosmic-ray antiprotons, positrons, and electrons from interactions of primary cosmic-ray nuclei with the interstellar gas, and to calculations of atmospheric muons and neutrinos. We report absolute spectra at the top of the atmosphere for cosmic-ray protons in the kinetic energy range 0.2-160 GeV and helium nuclei 0.15-80 GeV/nucleon. The corresponding magnetic rigidity ranges are 0.6-160 GV for protons and 1.1-160 GV for helium. These spectra are compared to measurements from previous BESS flights and from ATIC-2, PAMELA, and AMS-02. We also report the ratio of the proton and helium fluxes from 1.1 GV to 160 GV and compare to ratios from PAMELA and AMS-02.
[6]  oai:arXiv.org:1201.4622  [pdf] - 467136
The Tokyo Axion Helioscope
Comments:
Submitted: 2012-01-22
The Tokyo Axion Helioscope experiment aims to detect axions which are produced in the solar core. The helioscope uses a strong magnetic field in order to convert axions into X-ray photons and has a mounting to follow the sun very accurately. The photons are detected by an X-ray detector which is made of 16 PIN-photodiodes. In addition, a gas container and a gas regulation system is adopted for recovering the coherence between axions and photons in the conversion region giving sensitivity to axions with masses up to 2 eV. In this paper, we report on the technical detail of the Tokyo Axion Helioscope.
[7]  oai:arXiv.org:1201.2967  [pdf] - 1092966
Search for Antihelium with the BESS-Polar Spectrometer
Comments: 4 pages, 4 figures
Submitted: 2012-01-13
In two long-duration balloon flights over Antarctica, the BESS-Polar collaboration has searched for antihelium in the cosmic radiation with higher sensitivity than any reported investigation. BESS- Polar I flew in 2004, observing for 8.5 days. BESS-Polar II flew in 2007-2008, observing for 24.5 days. No antihelium candidate was found in BESS-Polar I data among 8.4\times 10^6 |Z| = 2 nuclei from 1.0 to 20 GV or in BESS-Polar II data among 4.0\times 10^7 |Z| = 2 nuclei from 1.0 to 14 GV. Assuming antihelium to have the same spectral shape as helium, a 95% confidence upper limit of 6.9 \times 10^-8 was determined by combining all the BESS data, including the two BESS-Polar flights. With no assumed antihelium spectrum and a weighted average of the lowest antihelium efficiencies from 1.6 to 14 GV, an upper limit of 1.0 \times 10^-7 was determined for the combined BESS-Polar data. These are the most stringent limits obtained to date.
[8]  oai:arXiv.org:1107.6000  [pdf] - 1083080
Measurement of the cosmic-ray antiproton spectrum at solar minimum with a long-duration balloon flight over Antarctica
Comments: 4 pages, 4 figures, submitted to Physical Review Letters
Submitted: 2011-07-29, last modified: 2011-12-10
The energy spectrum of cosmic-ray antiprotons from 0.17 to 3.5 GeV has been measured using 7886 antiprotons detected by BESS-Polar II during a long-duration flight over Antarctica near solar minimum in December 2007 and January 2008. This shows good consistency with secondary antiproton calculations. Cosmologically primary antiprotons have been investigated by comparing measured and calculated antiproton spectra. BESS-Polar II data show no evidence of primary antiprotons from evaporation of primordial black holes.
[9]  oai:arXiv.org:1002.0468  [pdf] - 33408
Tokyo axion helioscope experiment
Comments: 5 pages, 4 figures. Identification of dark matter 2008 (idm2008), August 18-22, 2008, Stockholm, Sweden
Submitted: 2010-02-02
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of higher density to explore higher mass region. From December 2007 through April 2008, the axion mass region 0.84 < m < 1.00eV was newly explored, where the axions in the "photon-coupling vs. mass" parameter region of the preferred axion models were newly searched. From the absence of any evidence, a limit on axion-photon coupling constant was set to be g < 5.6-13.4e-10/GeV at 95% confidence level in the above mass region.
[10]  oai:arXiv.org:0912.4797  [pdf] - 1018904
The Hayabusa Spacecraft Asteroid Multi-Band Imaging Camera: AMICA
Comments: 107 pages, 22 figures, 9 tables. will appear in Icarus
Submitted: 2009-12-24
The Hayabusa Spacecraft Asteroid Multiband Imaging Camera (AMICA) has acquired more than 1400 multispectral and high-resolution images of its target asteroid, 25143 Itokawa, since late August 2005. In this paper, we summarize the design and performance of AMICA. In addition, we describe the calibration methods, assumptions, and models, based on measurements. Major calibration steps include corrections for linearity and modeling and subtraction of bias, dark current, read-out smear, and pixel-to-pixel responsivity variations. AMICA v-band data were calibrated to radiance using in-flight stellar observations. The other band data were calibrated to reflectance by comparing them to ground-based observations to avoid the uncertainty of the solar irradiation in those bands. We found that the AMICA signal was linear with respect to the input signal to an accuracy of << 1% when the signal level was < 3800 DN. We verified that the absolute radiance calibration of the AMICA v-band (0.55 micron) was accurate to 4% or less, the accuracy of the disk-integrated spectra with respect to the AMICA v-band was about 1%, and the pixel-to-pixel responsivity (flatfield) variation was 3% or less. The uncertainty in background zero-level was 5 DN. From wide-band observations of star clusters, we found that the AMICA optics have an effective focal length of 120.80 \pm 0.03 mm, yielding a field-of-view (FOV) of 5.83 deg x 5.69 deg. The resulting geometric distortion model was accurate to within a third of a pixel. We demonstrated an image-restoration technique using the point-spread functions of stars, and confirmed that the technique functions well in all loss-less images. An artifact not corrected by this calibration is scattered light associated with bright disks in the FOV.
[11]  oai:arXiv.org:0911.0738  [pdf] - 30267
Prospects of Search for Solar Axions with Mass over 1 eV and Hidden Sector Photons
Comments: 4 pages, 5 figures, contribution to 5th Patras Workshop on Axions, WIMPs and WISPs, Durham, UK, 13-17 July 2009
Submitted: 2009-11-04
We present prospects of two experiments using the Tokyo Axion Helioscope. One is a search for solar axions. In the past measurements, axion mass from 0 to 0.27 eV and from 0.84 to 1.00 eV have been scanned and no positive evidence was seen. We are now actively preparing a new phase of the experiment aiming at axion mass over 1 eV. The other is a search for hidden sector photons from the Sun. We have been designing and testing some additional equipments, which have to be installed on the helioscope to search for hidden photons with mass of over $10^{-3}$ eV.
[12]  oai:arXiv.org:0805.1754  [pdf] - 12554
Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight
Comments: 18 pages, 1 table, 5 figures, submitted to Physics Letters B
Submitted: 2008-05-12, last modified: 2008-09-21
The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.
[13]  oai:arXiv.org:0809.0596  [pdf] - 15935
Tokyo Axion Helioscope
Comments: 4th Patras Workshop on Axions, WIMPs and WISPs
Submitted: 2008-09-03
A new search result of the Tokyo axion helioscope is presented. The axion helioscope consists of a dedicated cryogen-free 4T superconducting magnet with an effective length of 2.3 m and PIN photodiodes as x-ray detectors. Solar axions, if exist, would be converted into X-ray photons through the inverse Primakoff process in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. The present third phase measurement sets a new limit of g_{a\gamma\gamma}<(5.6--13.4)\times10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.0 eV at 95% confidence level.
[14]  oai:arXiv.org:0806.2230  [pdf] - 369033
Search for solar axions with mass around 1 eV using coherent conversion of axions into photons
Comments: 13 pages, 6 figures, to be published in PLB
Submitted: 2008-06-13, last modified: 2008-08-26
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m-long 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. A mass region around m_a = 1eV was newly explored. From the absence of any evidence, analysis sets a limit on axion-photon coupling constant to be g < 5.6-13.4x10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.00eV at 95% confidence level. It is the first result to search for the axion in the g-m_a parameter region of the preferred axion models with a magnetic helioscope.
[15]  oai:arXiv.org:0806.1471  [pdf] - 341922
Status report of the Tokyo axion helioscope experiment
Comments: 3 pages, 3 figures, submitted to be included in the proceedings of TAUP 2007
Submitted: 2008-06-09
We have searched for solar axions with a detector which consists of a 4T x 2.3m superconducting magnet, PIN-photodiode X-ray detectors, and an altazimuth mount to track the sun. The conversion region is filled with cold helium gas which modifies the axion mass at which coherent conversion occurs. In the past measurements, axion mass from 0 to 0.27eV have been scanned. Since no positive evidence was seen, an upper limit to the axion-photon coupling constant was set to be g < 6-10E-10/GeV (95%CL) depending on the axion masses. We are now actively preparing for a new stage of the experiment aiming at one to a few eV solar axions. In this mass region, our detector might be able to check parameter regions which are preferable to the axion models.
[16]  oai:arXiv.org:astro-ph/0611388  [pdf] - 86774
Measurements of 0.2 to 20 GeV/n cosmic-ray proton and helium spectra from 1997 through 2002 with the BESS spectrometer
Comments: 27 pages, 7 Tables, 9 figures, Submitted to Astroparticle Physics
Submitted: 2006-11-13, last modified: 2007-04-21
We measured low energy cosmic-ray proton and helium spectra in the kinetic energy range 0.215 - 21.5 GeV/n at different solar activities during a period from 1997 to 2002. The observations were carried out with the BESS spectrometer launched on a balloon at Lynn Lake, Canada. A calculation for the correction of secondary particle backgrounds from the overlying atmosphere was improved by using the measured spectra at small atmospheric depths ranging from 5 through 37 g/cm^2. The uncertainties including statistical and systematic errors of the obtained spectra at the top of atmosphere are 5-7 % for protons and 6-9 % for helium nuclei in the energy range 0.5 - 5 GeV/n.
[17]  oai:arXiv.org:astro-ph/0509577  [pdf] - 76158
Measurements of Atmospheric Antiprotons
Comments: Accepted for publication in PLB
Submitted: 2005-09-20, last modified: 2005-11-17
We measured atmospheric antiproton spectra in the energy range 0.2 to 3.4 GeV, at sea level and at balloon altitude in the atmospheric depth range 4.5 to 26 g/cm^2. The observed energy spectra, including our previous measurements at mountain altitude, were compared with estimated spectra calculated on various assumptions regarding the energy distribution of antiprotons that interacted with air nuclei.
[18]  oai:arXiv.org:astro-ph/0504361  [pdf] - 387089
Search for Cosmic-Ray Antideuterons
Comments: 4 pages, 3 figures, submitted to Phys. Rev. Lett
Submitted: 2005-04-15, last modified: 2005-07-06
We performed a search for cosmic-ray antideuterons using data collected during four BESS balloon flights from 1997 to 2000. No candidate was found. We derived, for the first time, an upper limit of 1.9E-4 (m^2 s sr GeV/nucleon)^(-1) for the differential flux of cosmic-ray antideuterons, at the 95% confidence level, between 0.17 and 1.15 GeV/nucleon at the top of the atmosphere.
[19]  oai:arXiv.org:astro-ph/0403704  [pdf] - 880720
Measurements of Primary and Atmospheric Cosmic-Ray Spectra with the BESS-TeV Spectrometer
Comments: 26 pages, 9 figures, 3 tables, Submitted to Phys. Lett. B
Submitted: 2004-03-31
Primary and atmospheric cosmic-ray spectra were precisely measured with the BESS-TeV spectrometer. The spectrometer was upgraded from BESS-98 to achieve seven times higher resolution in momentum measurement. We report absolute fluxes of primary protons and helium nuclei in the energy ranges, 1-540 GeV and 1-250 GeV/n, respectively, and absolute flux of atmospheric muons in the momentum range 0.6-400 GeV/c.
[20]  oai:arXiv.org:astro-ph/0205427  [pdf] - 49501
Measurements of atmospheric muon spectra at mountain altitude
Comments: Mean momentum in Table 1 was corrected
Submitted: 2002-05-24, last modified: 2003-11-29
We report new measurements of the atmospheric muons at mountain altitude. The measurement was carried out with the BESS detector at the top of Mt. Norikura, Japan. The altitude is 2,770 m above sea level. Comparing our results and predictions given by some interaction models, a further appropriate model has been investigated. These studies would improve accuracy of atmospheric neutrino calculations.
[21]  oai:arXiv.org:astro-ph/0306582  [pdf] - 1233170
Measurement of Cosmic-Ray Proton and Antiproton Spectra at Mountain Altitude
Comments: 10 pages, 5 figures, Submitted to Phys. Lett. B
Submitted: 2003-06-27
Cosmic-ray proton and antiproton spectra were measured at mountain altitude, 2770 m above sea level. We observed more than 2 x 10^5 protons and 10^2 antiprotons in a kinetic energy range between 0.25 and 3.3 GeV. The zenith-angle dependence of proton flux was obtained. The observed spectra were compared with theoretical predictions.
[22]  oai:arXiv.org:astro-ph/0305529  [pdf] - 57002
Measurement of Cosmic-Ray Proton, Antiproton and Muon Spectra at Mountain Altitude
Comments: To be published in the proceedings of ICRC2003
Submitted: 2003-05-28
Measurement of cosmic-ray proton, antiproton and muon spectra was carried out at mountain altitude. We observed 2 x 10^5 protons and 10^2 antiprotons in a kinetic energy region of 0.25 -- 3.3 GeV. Zenith-angle dependence of proton fluxes was obtained. Atmospheric muon spectra were measured simultaneously. The observed antiproton spectrum showed some deviation from theoretical predictions particularly in a low energy region.
[23]  oai:arXiv.org:astro-ph/0304102  [pdf] - 56010
Measurements of Proton, Helium and Muon Spectra at Small Atmospheric Depths with the BESS Spectrometer
Comments: 21 pages, 11 figures, 4 tables
Submitted: 2003-04-05, last modified: 2003-05-06
The cosmic-ray proton, helium, and muon spectra at small atmospheric depths of 4.5 -- 28 g/cm^2 were precisely measured during the slow descending period of the BESS-2001 balloon flight. The variation of atmospheric secondary particle fluxes as a function of atmospheric depth provides fundamental information to study hadronic interactions of the primary cosmic rays with the atmosphere.
[24]  oai:arXiv.org:astro-ph/0205344  [pdf] - 49418
Precise Measurements of Atmospheric Muon Fluxes with the BESS Spectrometer
Comments: 35 pages, 9 figures. Submitted to Astroparticle Physics
Submitted: 2002-05-21
The vertical absolute fluxes of atmospheric muons and muon charge ratio have been measured precisely at different geomagnetic locations by using the BESS spectrometer. The observations had been performed at sea level (30 m above sea level) in Tsukuba, Japan, and at 360 m above sea level in Lynn Lake, Canada. The vertical cutoff rigidities in Tsukuba (36.2 N, 140.1 E) and in Lynn Lake (56.5 N, 101.0 W) are 11.4 GV and 0.4 GV, respectively. We have obtained vertical fluxes of positive and negative muons in a momentum range from 0.6 to 20 GeV/c with systematic errors less than 3 % in both measurements. By comparing the data collected at two different geomagnetic latitudes, we have seen an effect of cutoff rigidity. The dependence on the atmospheric pressure and temperature, and the solar modulation effect have been also clearly observed. We also clearly observed the decrease of charge ratio of muons at low momentum side with at higher cutoff rigidity region.
[25]  oai:arXiv.org:astro-ph/0204388  [pdf] - 48933
Search for sub-electronvolt solar axions using coherent conversion of axions into photons in magnetic field and gas helium
Comments: 12 pages, 6 PostScript figures, accepted for publication in Phys. Lett. B
Submitted: 2002-04-23
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m-long 4T superconducting magnet, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In addition, a gas container to hold dispersion-matching gas has been developed and a mass region up to m_a=0.27eV was newly explored. From the absence of any evidence, analysis sets a limit on axion-photon coupling constant to be $g_{a\gamma\gamma}<6.8-10.9\times10^{-10}GeV^{-1}$ for the axion mass of 0.05<m_a<0.27eV at 95% confidence level, which is more stringent than the limit inferred from the solar-age consideration. This result gives currently the most stringent observational limit on the existence of solar axions in this mass region.
[26]  oai:arXiv.org:astro-ph/0109007  [pdf] - 387045
Measurements of Cosmic-ray Low-energy Antiproton and Proton Spectra in a Transient Period of the Solar Field Reversal
Comments: 4 pages, 4 figures, revised version accepted for publication in Phys. Rev. Lett
Submitted: 2001-09-02, last modified: 2002-01-25
The energy spectra of cosmic-ray low-energy antiprotons and protons have been measured by BESS in 1999 and 2000, during a period covering the solar magnetic field reversal. Based on these measurements, a sudden increase of the antiproton to proton flux ratio following the solar magnetic field reversal was observed, and it generally agrees with a drift model of the solar modulation.
[27]  oai:arXiv.org:astro-ph/0012338  [pdf] - 1507850
Recent results from the Tokyo axion helioscope experiment
Comments: 6 pages, 4 PostScript figures; submitted to Proceedings of IDM2000 (World Scientific)
Submitted: 2000-12-15
We have searched for axions which could have been produced in the solar core using an axion helioscope with a 2.3m-long 4T superconducting magnet. Axion mass region up to m_a=0.26eV was newly explored by introducing dispersion-matching gas. Preliminary analysis sets a limit on axion-photon coupling constant to be less than (6.4--9.6)e-10 GeV^{-1} (95%CL) for this mass region from the absence of the axion signal. This is more stringent than the limit inferred from the solar age consideration and also more stringent than the recent helioseismological bound.
[28]  oai:arXiv.org:astro-ph/0002481  [pdf] - 34824
Precise Measurement of Cosmic-Ray Proton and Helium Spectra with the BESS Spectrometer
Comments: 12 pages, 4 figures
Submitted: 2000-02-25
We report cosmic-ray proton and helium spectra in energy ranges of 1 to 120 GeV and 1 to 54 GeV/nucleon, respectively, measured by a balloon flight of the BESS spectrometer in 1998. The magnetic-rigidity of the cosmic-rays was reliably determined by highly precise measurement of the circular track in a uniform solenoidal magnetic field of 1 Tesla. Those spectra were determined within overall uncertainties of +-5 % for protons and +- 10 % for helium nuclei including statistical and systematic errors.
[29]  oai:arXiv.org:astro-ph/9906426  [pdf] - 346614
Precision Measurement of Cosmic-Ray Antiproton Spectrum
Comments: REVTeX, 4 pages including 4 eps figures
Submitted: 1999-06-26
The energy spectrum of cosmic-ray antiprotons has been measured in the range 0.18 to 3.56 GeV, based on 458 antiprotons collected by BESS in recent solar-minimum period. We have detected for the first time a distinctive peak at 2 GeV of antiprotons originating from cosmic-ray interactions with the interstellar gas. The peak spectrum is reproduced by theoretical calculations, implying that the propagation models are basically correct and that different cosmic-ray species undergo a universal propagation. Future BESS flights toward the solar maximum will help us to study the solar modulation and the propagation in detail and to search for primary antiproton components.
[30]  oai:arXiv.org:astro-ph/9809326  [pdf] - 398741
Measurement of Low-Energy Cosmic-Ray Antiprotons at Solar Minimum
Comments: REVTeX, 4 pages including 4 eps figures. Submitted to PRL
Submitted: 1998-09-25
The absolute fluxes of the cosmic-ray antiprotons at solar minimum are measured in the energy range 0.18 to 1.4 GeV, based on 43 events unambiguously detected in BESS '95 data. The resultant energy spectrum appears to be flat below 1 GeV, compatible with a possible admixture of primary antiproton component with a soft energy spectrum, while the possibility of secondary antiprotons alone explaining the data cannot be excluded with the present accuracy. Further improvement of statistical accuracy and extension of the energy range are planned in future BESS flights.
[31]  oai:arXiv.org:astro-ph/9710228  [pdf] - 98987
A New Limit on the Flux of Cosmic Antihelium
Comments: REVTeX, 4 pages (including 5 EPS figures). Submitted to PRL
Submitted: 1997-10-21
A very sensitive search for cosmic-ray antihelium was performed using data obtained from three scientific flights of BESS magnetic rigidity spectrometer. We have not observed any antihelium; this places a model-independent upper limit (95 % C.L.) on the antihelium flux of 6*10**(-4) m**(-2)sr**(-1)s**(-1) at the top of the atmosphere in the rigidity region 1 to 16 GV, after correcting for the estimated interaction loss of antihelium in the air and in the instrument. The corresponding upper limit on the Hebar/He flux ratio is 3.1*10**(-6), 30 times more stringent than the limits obtained in similar rigidity regions with magnetic spectrometers previous to BESS.