Normalized to: Vayonakis, A.
[1]
oai:arXiv.org:1509.02950 [pdf] - 1385376
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements
Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Sayers, Jack;
Zemcov, Michael;
Glenn, Jason;
Golwala, Sunil R.;
Maloney, Philip R.;
Siegel, Seth R.;
Wheeler, Jordan;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran P.;
Gao, Jiansong;
Hollister, Matthew I.;
Lam, Albert;
LeDuc, Henry G.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David A.;
Mroczkowski, Tony K.;
Noroozian, Omid;
Nguyen, Hien T.;
Radford, Simon J.;
Schlaerth, James A.;
Vayonakis, Anastasios;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2015-09-09, last modified: 2016-03-01
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images
towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech
Submillimeter Observatory with the Multiwavelength Submillimeter Inductance
Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As
part of our analysis, we have used higher frequency data from Herschel-SPIRE
and previously published lower frequency radio data to subtract the signal from
the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the
AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined
with X-ray spectroscopic measurements of the temperature of the intra-cluster
medium (ICM) from Chandra, we constrain the ICM optical depth to be $\tau_e =
7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar
velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both
quantities are limited by measurement noise rather than calibration
uncertainties or astrophysical contamination, and significant improvements are
possible with deeper observations. Our best-fit velocity is in good agreement
with one previously published SZ effect analysis and in mild tension with the
other, although some or all of that tension may be because that measurement
samples a much smaller cluster volume. Furthermore, our best-fit optical depth
implies a gas mass slightly larger than the Chandra-derived value, implying the
cluster is elongated along the line of sight.
[2]
oai:arXiv.org:1211.0595 [pdf] - 585603
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Golwala, Sunil R.;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran;
Gao, Jiansong;
Gill, Amandeep K.;
Glenn, Jason;
Hollister, Matthew I.;
LeDuc, Henry G.;
Maloney, Philip R.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David;
Noroozian, Omid;
Nguyen, Hien T.;
Sayers, Jack;
Schlaerth, James A.;
Siegel, Seth;
Vayonakis, Anastasios K.;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2012-11-03
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance
Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is
designed to have a 14', diffraction-limited field-of-view instrumented with
2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04,
1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies,
galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own
and nearby galaxies. MUSIC uses broadband superconducting phased-array
slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to
define spectral bands, and microwave kinetic inductance detectors to
senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72
spatial pixels each. It is coupled to the telescope via an ambient temperature
ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the
image of the primary mirror formed by the ellipsoidal mirror. Dielectric and
metal mesh filters are used to block thermal infrared and out-of-band
radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle
cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates
Earth's magnetic field. Each focal plane tile is read out by a single pair of
coaxes and a HEMT amplifier. The readout system consists of 16 copies of
custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We
focus on recent updates on the instrument design and results from the
commissioning of the full camera in 2012.
[3]
oai:arXiv.org:astro-ph/0606366 [pdf] - 82806
Antenna-Coupled TES Bolometers for CMB Polarimetry
Kuo, C. L.;
Bock, J. J.;
Chattopadthyay, G.;
Goldin, A.;
Golwala, S.;
Holmes, W.;
Irwin, K.;
Kenyon, M.;
Lange, A. E.;
LeDuc, H. G.;
Rossinot, P.;
Vayonakis, A.;
Wang, G.;
Yun, M.;
Zmuidzinas, J.
Submitted: 2006-06-14
We have developed a completely lithographic antenna-coupled bolometer for CMB
polarimetry. The necessary components of a millimeter wave radiometer -- a beam
forming element, a band defining filter, and the TES detectors -- are
fabricated on a silicon chip with photolithography. The densely populated
antennas allow a very efficient use of the focal plane area. We have fabricated
and characterized a series of prototype devices. We find that their properties,
including the frequency and angular responses, are in good agreement with the
theoretical expectations. The devices are undergoing optimization for upcoming
CMB experiments.