Normalized to: Soma, A.
[1]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[2]
oai:arXiv.org:1403.5421 [pdf] - 862588
Limits on light WIMPs with a germanium detector at 177 eVee threshold at
the China Jinping Underground Laboratory
Liu, S. K.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Wong, H. T.;
Li, Y. J.;
Lin, S. T.;
Chang, J. P.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Q.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Lü, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wu, S. Y.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xiao, R. Q.;
Xing, H. Y.;
Xu, F. Z.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, C. W.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhao, W.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2014-03-21, last modified: 2014-08-01
The China Dark Matter Experiment reports results on light WIMP dark matter
searches at the China Jinping Underground Laboratory with a germanium detector
array with a total mass of 20 g. The physics threshold achieved is 177 eVee
("ee" represents electron equivalent energy) at 50% signal efficiency. With
0.784 kg-days of data, exclusion region on spin-independent coupling with the
nucleon is derived, improving over our earlier bounds at WIMP mass less than
4.6 GeV.
[3]
oai:arXiv.org:1306.4135 [pdf] - 719413
First results on low-mass WIMP from the CDEX-1 experiment at the China
Jinping underground Laboratory
Zhao, W.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Li, Y. J.;
Lin, S. T.;
Bai, Y.;
Bi, Y.;
Chang, J. P.;
Chen, N.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, C.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Hu, X. H.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Liu, S. K.;
Lv, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wong, H. T.;
Wu, S. Y.;
Wu, W.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xing, H. Y.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhong, S. N.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2013-06-18, last modified: 2013-08-08
The China Dark matter Experiment collaboration reports the first experimental
limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type
point-contact germanium detector at the China Jinping underground Laboratory
where the rock overburden is more than 2400 m. The energy threshold achieved
was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N=
1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent
cross-section at WIMP mass of 7 GeV before differentiating bulk signals from
the surface backgrounds.
[4]
oai:arXiv.org:1305.0401 [pdf] - 1166364
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark
Matter Searches
Kang, Ke-Jun;
Yue, Qian;
Wu, Yu-Cheng;
Cheng, Jian-Ping;
Li, Yuan-Jing;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Chuang, You-Chun;
Dend, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Huang, Teng-Rui;
Jiang, Hao;
Li, Hau-Bin;
Li, Jian-Min;
Li, Jin;
Li, Jun;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liao, Heng-Ye;
Lin, Fong-Kay;
Lin, Shin-Ted;
Liu, Shu-Kui;
Lv, Lan-Chun;
Ma, Hao;
Mao, Shao-Ji;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Singh, Lakhwinder;
Singh, Manoj Kumar;
Soma, Arun Kumar;
Su, Jian;
Tang, Chang-Jian;
Tseng, Chao-Hsiung;
Wang, Ji-Min;
Wang, Li;
Wang, Qing;
Wong, Tsz-King Henry;
Wu, Shi-Yong;
Wu, Wei;
Wu, Yu-Cheng;
Xing, Hao-Yang;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yang, Song-Wei;
Yi, Nan;
Yu, Chun-Xu;
Yu, Hao;
Yu, Xun-Zhen;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Yun-Hua;
Zhao, Ming-Gang;
Zhao, Wei;
Zhong, Su-Ning;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-05-02
The CDEX Collaboration has been established for direct detection of light
dark matter particles, using ultra-low energy threshold p-type point-contact
germanium detectors, in China JinPing underground Laboratory (CJPL). The first
1 kg point-contact germanium detector with a sub-keV energy threshold has been
tested in a passive shielding system located in CJPL. The outputs from both the
point-contact p+ electrode and the outside n+ electrode make it possible to
scan the lower energy range of less than 1 keV and at the same time to detect
the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode
may also provide a more powerful method for signal discrimination for dark
matter experiment. Some key parameters, including energy resolution, dead time,
decay times of internal X-rays, and system stability, have been tested and
measured. The results show that the 1 kg point-contact germanium detector,
together with its shielding system and electronics, can run smoothly with good
performances. This detector system will be deployed for dark matter search
experiments.