Normalized to: Schlaerth, J.
[1]
oai:arXiv.org:1509.02950 [pdf] - 1385376
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements
Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Sayers, Jack;
Zemcov, Michael;
Glenn, Jason;
Golwala, Sunil R.;
Maloney, Philip R.;
Siegel, Seth R.;
Wheeler, Jordan;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran P.;
Gao, Jiansong;
Hollister, Matthew I.;
Lam, Albert;
LeDuc, Henry G.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David A.;
Mroczkowski, Tony K.;
Noroozian, Omid;
Nguyen, Hien T.;
Radford, Simon J.;
Schlaerth, James A.;
Vayonakis, Anastasios;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2015-09-09, last modified: 2016-03-01
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images
towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech
Submillimeter Observatory with the Multiwavelength Submillimeter Inductance
Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As
part of our analysis, we have used higher frequency data from Herschel-SPIRE
and previously published lower frequency radio data to subtract the signal from
the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the
AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined
with X-ray spectroscopic measurements of the temperature of the intra-cluster
medium (ICM) from Chandra, we constrain the ICM optical depth to be $\tau_e =
7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar
velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both
quantities are limited by measurement noise rather than calibration
uncertainties or astrophysical contamination, and significant improvements are
possible with deeper observations. Our best-fit velocity is in good agreement
with one previously published SZ effect analysis and in mild tension with the
other, although some or all of that tension may be because that measurement
samples a much smaller cluster volume. Furthermore, our best-fit optical depth
implies a gas mass slightly larger than the Chandra-derived value, implying the
cluster is elongated along the line of sight.
[2]
oai:arXiv.org:1211.0595 [pdf] - 585603
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Golwala, Sunil R.;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran;
Gao, Jiansong;
Gill, Amandeep K.;
Glenn, Jason;
Hollister, Matthew I.;
LeDuc, Henry G.;
Maloney, Philip R.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David;
Noroozian, Omid;
Nguyen, Hien T.;
Sayers, Jack;
Schlaerth, James A.;
Siegel, Seth;
Vayonakis, Anastasios K.;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2012-11-03
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance
Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is
designed to have a 14', diffraction-limited field-of-view instrumented with
2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04,
1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies,
galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own
and nearby galaxies. MUSIC uses broadband superconducting phased-array
slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to
define spectral bands, and microwave kinetic inductance detectors to
senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72
spatial pixels each. It is coupled to the telescope via an ambient temperature
ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the
image of the primary mirror formed by the ellipsoidal mirror. Dielectric and
metal mesh filters are used to block thermal infrared and out-of-band
radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle
cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates
Earth's magnetic field. Each focal plane tile is read out by a single pair of
coaxes and a HEMT amplifier. The readout system consists of 16 copies of
custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We
focus on recent updates on the instrument design and results from the
commissioning of the full camera in 2012.
[3]
oai:arXiv.org:0904.3943 [pdf] - 23655
Studies of Millimeter-Wave Atmospheric Noise Above Mauna Kea
Sayers, J.;
Golwala, S. R.;
Ade, P. A. R.;
Aguirre, J. E.;
Bock, J. J.;
Edgington, S. F.;
Glenn, J.;
Goldin, A.;
Haig, D.;
Lange, A. E.;
Laurent, G. T.;
Mauskopf, P. D.;
Nguyen, H. T.;
Rossinot, P.;
Schlaerth, J.
Submitted: 2009-04-24, last modified: 2009-11-20
We report measurements of the fluctuations in atmospheric emission
(atmospheric noise) above Mauna Kea recorded with Bolocam at 143 and 268 GHz
from the Caltech Submillimeter Observatory (CSO). The 143 GHz data were
collected during a 40 night observing run in late 2003, and the 268 GHz
observations were made in early 2004 and early 2005 over a total of 60 nights.
Below 0.5 Hz, the data time-streams are dominated by atmospheric noise in all
observing conditions. The atmospheric noise data are consistent with a
Kolmogorov-Taylor (K-T) turbulence model for a thin wind-driven screen, and the
median amplitude of the fluctuations is 280 mK^2 rad^(-5/3) at 143 GHz and 4000
mK^2 rad^(-5/3) at 268 GHz. Comparing our results with previous ACBAR data, we
find that the normalization of the power spectrum of the atmospheric noise
fluctuations is a factor of 80 larger above Mauna Kea than above the South Pole
at millimeter wavelengths. Most of this difference is due to the fact that the
atmosphere above the South Pole is much drier than the atmosphere above Mauna
Kea. However, the atmosphere above the South Pole is slightly more stable as
well: the fractional fluctuations in the column depth of precipitable water
vapor are a factor of sqrt(2) smaller at the South Pole compared to Mauna Kea.
Based on our atmospheric modeling, we developed several algorithms to remove
the atmospheric noise, and the best results were achieved when we described the
fluctuations using a low-order polynomial in detector position over the 8
arcmin field of view (FOV). However, even with these algorithms, we were not
able to reach photon-background-limited instrument photometer (BLIP)
performance at frequencies below 0.5 Hz in any observing conditions.