sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mazin, Ben A.

Normalized to: Mazin, B.

39 article(s) in total. 283 co-authors, from 1 to 16 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:2007.06496  [pdf] - 2132084
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays
Comments: in IEEE Transactions on Applied Superconductivity
Submitted: 2020-07-13
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax
[2]  oai:arXiv.org:2004.14576  [pdf] - 2087011
Superconducting Materials for Microwave Kinetic Inductance Detectors
Comments: 19 pages, 4 figures. To appear in the Handbook of Superconducting Materials
Submitted: 2020-04-28
The superconducting materials that make up an MKID have a significant effect on its performance. The $T_\textrm{c}$ and normal state resistivity $\rho_\textrm{N}$ of the film determine the penetration depth $\lambda$ and therefore how much kinetic inductance it has. The ratio of kinetic inductance to total inductance ($\alpha$), the volume of the inductor, and $Q_\textrm{m}$ determines the magnitude of the response to incoming energy. The quasiparticle lifetime $\tau_\textrm{qp}$ is the characteristic time during which the MKID's surface impedance is modified by the incoming energy. Many materials have been explored for use in superconducting resonators and MKIDs, but that information is often not published or scattered around the literature. This chapter contains information and references on the work that has been done with thin film lithographed circuits for MKIDs over the last two decades. Note that measured material properties such as the internal loss quality factor $Q_\textrm{i}$ and quasiparticle lifetime $\tau_\textrm{qp}$ vary significantly depending on how the MKID superconducting thin film is made and the system they are measured in, so it is best to interpret all stated values as typical but not definitive. Values are omitted in cases when there aren't enough measurements or there is too much disagreement in the literature to estimate a typical value. In order to be as complete as possible some unpublished results from the author's lab are included and can be identified by the lack of a reference. Unless noted all films are polycrystalline or amorphous.
[3]  oai:arXiv.org:2004.00736  [pdf] - 2085203
Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
Comments: 9 pages, 8 figures, 1 table. Submitted to SUST
Submitted: 2020-04-01
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 \mu \Omega. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, we study how sputter conditions and especially the power applied to the target during the deposition, affect the hafnium $T_{C}$, resistivity, stress, texture and preferred crystal orientation. We find that the position of the target with respect to the substrate strongly affects the orientation of the crystallites in the films and the internal quality factor, $Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that a DC magnetron sputter deposition at a normal angle of incidence, low pressure, and low plasma power promotes the growth of compressive (002)-oriented films and that such films can be used to make high quality factor MKIDs with $Q_{i}$ up to 600,000.
[4]  oai:arXiv.org:1911.06434  [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Comments:
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $\mu$s and resolving powers of ~9 at 800 nm.
[5]  oai:arXiv.org:1907.07742  [pdf] - 1938551
Enabling the next generation of scientific discoveries by embracing photonic technologies
Comments: 11 pages, 3 figures, NAS astro2020 whitepaper
Submitted: 2019-07-17, last modified: 2019-08-13
The fields of Astronomy and Astrophysics are technology limited, where the advent and application of new technologies to astronomy usher in a flood of discoveries altering our understanding of the Universe (e.g., recent cases include LIGO and the GRAVITY instrument at the VLTI). Currently, the field of astronomical spectroscopy is rapidly approaching an impasse: the size and cost of instruments, especially multi-object and integral field spectrographs for extremely large telescopes (ELTs), are pushing the limits of what is feasible, requiring optical components at the very edge of achievable size and performance. For these reasons, astronomers are increasingly looking for innovative solutions like photonic technologies that promote instrument miniaturization and simplification, while providing superior performance. Astronomers have long been aware of the potential of photonic technologies. The goal of this white paper is to draw attention to key photonic technologies and developments over the past two decades and demonstrate there is new momentum in this arena. We outline where the most critical efforts should be focused over the coming decade in order to move towards realizing a fully photonic instrument. A relatively small investment in this technology will advance astronomical photonics to a level where it can reliably be used to solve challenging instrument design limitations. For the benefit of both ground and space borne instruments alike, an endorsement from the National Academy of Sciences decadal survey will ensure that such solutions are set on a path to their full scientific exploitation, which may one day address a broad range of science cases outlined in the KSPs.
[6]  oai:arXiv.org:1908.02775  [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Comments: Astro2020 APC Whitepaper. 16 pages, 10 figures
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
[7]  oai:arXiv.org:1907.05191  [pdf] - 1914761
Astro2020 Activity, Project of State of the Profession Consideration (APC) White Paper: All-Sky Near Infrared Space Astrometry. State of the Profession Considerations: Development of Scanning NIR Detectors for Astronomy
Comments:
Submitted: 2019-07-11
Gaia is a revolutionary space mission developed by ESA and is delivering 5 parameter astrometry, photometry and radial velocities over the whole sky with astrometric accuracies down to a few tens of micro-arcseconds. A weakness of Gaia is that it only operates at optical wavelengths. However, much of the Galactic centre and the spiral arm regions, important for certain studies, are obscured by interstellar extinction and this makes it difficult for Gaia to deeply probe. This problem can be overcome by switching to the Near Infra-Red (NIR) but this is not possible with silicon CCDs. Additionally, to scan the entire sky and make global absolute parallax measurements the spacecraft must have a constant rotation and this requires the detectors operate in Time Delayed Integration (TDI) mode or similar.
[8]  oai:arXiv.org:1907.03078  [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Comments:
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
[9]  oai:arXiv.org:1906.03354  [pdf] - 1975296
Stochastic Speckle Discrimination with Time-Tagged Photon Lists: Digging Below the Speckle Noise Floor
Comments:
Submitted: 2019-06-07
We present an algorithm that uses the distribution of photon arrival times to distinguish speckles from incoherent sources, like planets and disks, in high contrast images. Using simulated data, we show that our approach can overcome the noise limit from fluctuating speckle intensity. The algorithm is likely to be most advantageous when a coronagraph limits the coherent diffraction pattern in the image plane but the intensity is still strongly modulated by fast-timescale uncorrected stellar light, for example from atmospheric turbulence. These conditions are common at small inner working angles and will allow probing of exoplanet populations at smaller angular separations. The technique requires a fast science camera that can temporally resolve the speckle fluctuations, and the detection of many photons per speckle decorrelation time. Since the algorithm directly extracts the incoherent light, standard differential imaging post-processing techniques can be performed afterwards to further boost the signal.
[10]  oai:arXiv.org:1905.04275  [pdf] - 1881118
Directly Imaging Rocky Planets from the Ground
Comments: 8 pages, 1 figure, Astro2020 Science White Paper
Submitted: 2019-05-10
Over the past three decades instruments on the ground and in space have discovered thousands of planets outside the solar system. These observations have given rise to an astonishingly detailed picture of the demographics of short-period planets, but are incomplete at longer periods where both the sensitivity of transit surveys and radial velocity signals plummet. Even more glaring is that the spectra of planets discovered with these indirect methods are either inaccessible (radial velocity detections) or only available for a small subclass of transiting planets with thick, clear atmospheres. Direct detection can be used to discover and characterize the atmospheres of planets at intermediate and wide separations, including non-transiting exoplanets. Today, a small number of exoplanets have been directly imaged, but they represent only a rare class of young, self-luminous super-Jovian-mass objects orbiting tens to hundreds of AU from their host stars. Atmospheric characterization of planets in the <5 AU regime, where radial velocity (RV) surveys have revealed an abundance of other worlds, is technically feasible with 30-m class apertures in combination with an advanced AO system, coronagraph, and suite of spectrometers and imagers. There is a vast range of unexplored science accessible through astrometry, photometry, and spectroscopy of rocky planets, ice giants, and gas giants. In this whitepaper we will focus on one of the most ambitious science goals --- detecting for the first time habitable-zone rocky (<1.6 R_Earth) exoplanets in reflected light around nearby M-dwarfs
[11]  oai:arXiv.org:1903.05319  [pdf] - 1848658
Imaging Giant Protoplanets with the ELTs
Comments: Science white paper submitted to the Astro2020 Decadal Survey
Submitted: 2019-03-13
We have now accumulated a wealth of observations of the planet-formation environment and of mature planetary systems. These data allow us to test and refine theories of gas-giant planet formation by placing constraints on the conditions and timescale of this process. Yet a number of fundamental questions remain unanswered about how protoplanets accumulate material, their photospheric properties and compositions, and how they interact with protoplanetary disks. While we have begun to detect protoplanet candidates during the last several years, we are presently only sensitive to the widest separation, highest mass / accretion rate cases. Current observing facilities lack the angular resolution and inner working angle to probe the few-AU orbital separations where giant planet formation is thought to be most efficient. They also lack the contrast to detect accretion rates that would form lower mass gas giants and ice giants. Instruments and telescopes coming online over the next decade will provide high contrast in the inner giant-planet-forming regions around young stars, allowing us to build a protoplanet census and to characterize planet formation in detail for the first time.
[12]  oai:arXiv.org:1903.05468  [pdf] - 1848675
The Critical, Strategic Importance of Adaptive Optics-Assisted Ground-Based Telescopes for the Success of Future NASA Exoplanet Direct Imaging Missions
Comments: 5 pages, 3 figures; Astro2020 Decadal Survey submission; argues for strategic NASA support of ground-based exoplanet direct imaging science programs and tech development. arXiv admin note: substantial text overlap with arXiv:1803.05453
Submitted: 2019-03-11
Ground-based telescopes coupled with adaptive optics (AO) have been playing a leading role in exoplanet direct imaging science and technological development for the past two decades and will continue to have an indispensable role for the next decade and beyond. Over the next decade, extreme AO systems on 8-10m telescopes will 1) mitigate risk for WFIRST-CGI by identifying numerous planets the mission can spectrally characterize, 2) validate performance requirements and motivate improvements to atmosphere models needed to unambiguously characterize solar system-analogues from space, and 3) mature novel technological innovations useful for space. Extremely Large Telescopes can deliver the first thermal infrared (10 $\mu m$) images of rocky planets around Sun-like stars and identify biomarkers. These data provide a future NASA direct imaging flagship mission (i.e. HabEx, LUVOIR) with numerous exo-Earth candidates and critical ancillary information to help clarify whether these planets are habitable.
[13]  oai:arXiv.org:1809.08301  [pdf] - 1755190
SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies
Comments: 12 pages, 9 figures, conference proceedings (SPIE Astronomical telescopes and instrumentation 2018)
Submitted: 2018-09-21
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an extremely modular high-contrast instrument installed on the Subaru telescope in Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a 8-meter telescope makes it a prime instrument for the detection and characterization of exoplanets and stellar environments over a large portion of the sky. In addition, SCExAO's unique design makes it the ideal instrument to test innovative technologies and algorithms quickly in a laboratory setup and subsequently deploy them on-sky. SCExAO benefits from a first stage of wavefront correction with the facility adaptive optics AO188, and splits the 600-2400 nm spectrum towards a variety of modules, in visible and near infrared, optimized for a large range of science cases. The integral field spectrograph CHARIS, with its J, H or K-band high-resolution mode or its broadband low-resolution mode, makes SCExAO a prime instrument for exoplanet detection and characterization. Here we report on the recent developments and scientific results of the SCExAO instrument. Recent upgrades were performed on a number of modules, like the visible polarimetric module VAMPIRES, the high-performance infrared coronagraphs, various wavefront control algorithms, as well as the real-time controller of AO188. The newest addition is the 20k-pixel Microwave Kinetic Inductance Detector (MKIDS) Exoplanet Camera (MEC) that will allow for previously unexplored science and technology developments. MEC, coupled with novel photon-counting speckle control, brings SCExAO closer to the final design of future high-contrast instruments optimized for Giant Segmented Mirror Telescopes (GSMTs).
[14]  oai:arXiv.org:1808.09632  [pdf] - 1741340
Direct Imaging in Reflected Light: Characterization of Older, Temperate Exoplanets With 30-m Telescopes
Comments: (March 2018) Submitted to the Exoplanet Science Strategy committee of the NAS
Submitted: 2018-08-29
Direct detection, also known as direct imaging, is a method for discovering and characterizing the atmospheres of planets at intermediate and wide separations. It is the only means of obtaining spectra of non-transiting exoplanets. Characterizing the atmospheres of planets in the <5 AU regime, where RV surveys have revealed an abundance of other worlds, requires a 30-m-class aperture in combination with an advanced adaptive optics system, coronagraph, and suite of spectrometers and imagers - this concept underlies planned instruments for both TMT (the Planetary Systems Imager, or PSI) and the GMT (GMagAO-X). These instruments could provide astrometry, photometry, and spectroscopy of an unprecedented sample of rocky planets, ice giants, and gas giants. For the first time habitable zone exoplanets will become accessible to direct imaging, and these instruments have the potential to detect and characterize the innermost regions of nearby M-dwarf planetary systems in reflected light. High-resolution spectroscopy will not only illuminate the physics and chemistry of exo-atmospheres, but may also probe rocky, temperate worlds for signs of life in the form of atmospheric biomarkers (combinations of water, oxygen and other molecular species). By completing the census of non-transiting worlds at a range of separations from their host stars, these instruments will provide the final pieces to the puzzle of planetary demographics. This whitepaper explores the science goals of direct imaging on 30-m telescopes and the technology development needed to achieve them.
[15]  oai:arXiv.org:1808.03304  [pdf] - 1731144
The Planetary Systems Imager: 2-5 Micron Channel
Comments: 7 pages, 5 figures
Submitted: 2018-08-09
We summarize the red channel (2-5 micron) of the Planetary Systems Imager (PSI), a proposed second-generation instrument for the TMT. Cold exoplanets emit the majority of their light in the thermal infrared, which means these exoplanets can be detected at a more modest contrast than at other wavelengths. PSI-Red will be able to detect and characterize a wide variety of exoplanets, including radial-velocity planets on wide orbits, accreting protoplanets in nearby star-forming regions, and reflected-light planets around the nearest stars. PSI-Red will feature an imager, a low-resolution lenslet integral field spectrograph, a medium-resolution lenslet+slicer integral field spectrograph, and a fiber-fed high-resolution spectrograph.
[16]  oai:arXiv.org:1807.04315  [pdf] - 1714869
MagAO-X: project status and first laboratory results
Comments: Presented at SPIE Astronomical Telescopes and Instrumentation 2018
Submitted: 2018-07-11
MagAO-X is an entirely new "extreme" adaptive optics system for the Magellan Clay 6.5 m telescope, funded by the NSF MRI program starting in Sep 2016. The key science goal of MagAO-X is high-contrast imaging of accreting protoplanets at H$\alpha$. With 2040 actuators operating at up to 3630 Hz, MagAO-X will deliver high Strehls (>70%), high resolution (19 mas), and high contrast ($< 1\times10^{-4}$) at H$\alpha$ (656 nm). We present an overview of the MagAO-X system, review the system design, and discuss the current project status.
[17]  oai:arXiv.org:1807.04341  [pdf] - 1714873
Real-time estimation and correction of quasi-static aberrations in ground-based high contrast imaging systems with high frame-rates
Comments: 10 pages, 6 figures
Submitted: 2018-07-11
The success of ground-based, high contrast imaging for the detection of exoplanets in part depends on the ability to differentiate between quasi-static speckles caused by aberrations not corrected by adaptive optics (AO) systems, known as non-common path aberrations (NCPAs), and the planet intensity signal. Frazin (ApJ, 2013) introduced a post-processing algorithm demonstrating that simultaneous millisecond exposures in the science camera and wavefront sensor (WFS) can be used with a statistical inference procedure to determine both the series expanded NCPA coefficients and the planetary signal. We demonstrate, via simulation, that using this algorithm in a closed-loop AO system, real-time estimation and correction of the quasi-static NCPA is possible without separate deformable mirror (DM) probes. Thus the use of this technique allows for the removal of the quasi-static speckles that can be mistaken for planetary signals without the need for new optical hardware, improving the efficiency of ground-based exoplanet detection. In our simulations, we explore the behavior of the Frazin Algorithm (FA) and the dependence of its convergence to an accurate estimate on factors such as Strehl ratio, NCPA strength, and number of algorithm search basis functions. We then apply this knowledge to simulate running the algorithm in real-time in a nearly ideal setting. We then discuss adaptations that can be made to the algorithm to improve its real-time performance, and show their efficacy in simulation. A final simulation tests the technique's resilience against imperfect knowledge of the AO residual phase, motivating an analysis of the feasibility of using this technique in a real closed-loop Extreme AO system such as SCExAO or MagAO-X, in terms of computational complexity and the accuracy of the estimated quasi-static NCPA correction.
[18]  oai:arXiv.org:1803.10420  [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Comments: 17 pages, 17 figures. PASP Published
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
[19]  oai:arXiv.org:1712.08584  [pdf] - 1607148
Pioneering high contrast science instruments for planet characterization on giant segmented mirror telescopes
Comments: 11 pages, 3 figures, AO4ELTs4 conference
Submitted: 2017-12-22
A suite of science instruments is critical to any high contrast imaging facility, as it defines the science capabilities and observing modes available. SCExAO uses a modular approach which allows for state-of-the-art visitor modules to be tested within an observatory environment on an 8-m class telescope. This allows for rapid prototyping of new and innovative imaging techniques that otherwise take much longer in traditional instrument design. With the aim of maturing science modules for an advanced high contrast imager on an giant segmented mirror telescopes (GSMTs) that will be capable of imaging terrestrial planets, we offer an overview and status update on the various science modules currently under test within the SCExAO instrument.
[20]  oai:arXiv.org:1710.07318  [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Comments: 16 pages, 8 figures, published in Optics Express
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
[21]  oai:arXiv.org:1610.00725  [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
Comments: 5 pages, 5 figures, accepted by APL
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated PtSi microresonators with superconducting critical temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim 10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp} \approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$, of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.
[22]  oai:arXiv.org:1603.05270  [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Comments: 4 pages, 2 figures, accepted to MNRAS
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
[23]  oai:arXiv.org:1509.02950  [pdf] - 1385376
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Comments: Accepted for publication in ApJ
Submitted: 2015-09-09, last modified: 2016-03-01
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously published lower frequency radio data to subtract the signal from the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined with X-ray spectroscopic measurements of the temperature of the intra-cluster medium (ICM) from Chandra, we constrain the ICM optical depth to be $\tau_e = 7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both quantities are limited by measurement noise rather than calibration uncertainties or astrophysical contamination, and significant improvements are possible with deeper observations. Our best-fit velocity is in good agreement with one previously published SZ effect analysis and in mild tension with the other, although some or all of that tension may be because that measurement samples a much smaller cluster volume. Furthermore, our best-fit optical depth implies a gas mass slightly larger than the Chandra-derived value, implying the cluster is elongated along the line of sight.
[24]  oai:arXiv.org:1507.05631  [pdf] - 1259174
The ARCONS Pipeline: Data Reduction for MKID Arrays
Comments: 16 pages, 19 figures, pdflatex, accepted for ApJS
Submitted: 2015-07-20
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. We outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.
[25]  oai:arXiv.org:1506.07537  [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
Comments: 7 pages, 4 figures, accepted for publication in Applied Physics Letters
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.
[26]  oai:arXiv.org:1506.03458  [pdf] - 1161888
Science with KRAKENS
Comments: 19 pages, 17 figures
Submitted: 2015-06-10
The Keck science community is entering an era of unprecedented change. Powerful new instrument like ZTF, JWST, LSST, and the ELTs will catalyze this change, and we must be ready to take full advantage to maintain our position of scientific leadership. The best way to do this is to continue the UC and Caltech tradition of technical excellence in instrumentation. In this whitepaper we describe a new instrument called KRAKENS to help meet these challenges. KRAKENS uses a unique detector technology (MKIDs) to enable groundbreaking science across a wide range of astrophysical research topics. This document will lay out the detailed expected science return of KRAKENS.
[27]  oai:arXiv.org:1309.3270  [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
Comments: 5 pages, 5 figures. Updated to match revised version, accepted to ApJL Nov 7, 2013. Several additions and improved DM in timing solution
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
[28]  oai:arXiv.org:1309.4087  [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Comments: 8 pages, 7 figures, submitted to MNRAS
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.
[29]  oai:arXiv.org:1307.5066  [pdf] - 1172836
Giga-z: A 100,000 Object Superconducting Spectrophotometer for LSST Follow-up
Comments: 16 pages, 10 figures, 5 tables. Accepted for publication in ApJS
Submitted: 2013-07-18
We simulate the performance of a new type of instrument, a Superconducting Multi-Object Spectrograph (SuperMOS), that uses Microwave Kinetic Inductance Detectors (MKIDs). MKIDs, a new detector technology, feature good QE in the UVOIR, can count individual photons with microsecond timing accuracy and, like X-ray calorimeters, determine their energy to several percent. The performance of Giga-z, a SuperMOS designed for wide field imaging follow-up observations, is evaluated using simulated observations of the COSMOS mock catalog with an array of 100,000 R_{423 nm} = E/\Delta E = 30 MKID pixels. We compare our results against a simultaneous simulation of LSST observations. In three years on a dedicated 4 m-class telescope, Giga-z could observe ~ 2 billion galaxies, yielding a low resolution spectral energy distribution (SED) spanning 350 - 1350 nm for each; 1000 times the number measured with any currently proposed LSST spectroscopic follow-up, at a fraction of the cost and time. Giga-z would provide redshifts for galaxies up to z ~ 6 with magnitudes m_i < 25, with accuracy \sigma_{\Delta z/(1+z)} = 0.03 for the whole sample, and \sigma_{\Delta z/(1+z)} = 0.007 for a select subset. We also find catastrophic failure rates and biases that are consistently lower than for LSST. The added constraint on Dark Energy parameters for WL+CMB by Giga-z using the FoMSWG default model is equivalent to multiplying the LSST Fisher matrix by a factor of \alpha = 1.27 (w_p), 1.53 (w_a), or 1.98 (\Delta \gamma). This is equivalent to multiplying both the LSST coverage area and the training sets by \alpha, and reducing all systematics by a factor of 1/sqrt(\alpha), advantages that are robust to even more extreme models of intrinsic alignment.
[30]  oai:arXiv.org:1306.4674  [pdf] - 1172164
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
Comments: 12 pages, 16 figures, submitted to PASP
Submitted: 2013-06-19
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.
[31]  oai:arXiv.org:1211.0595  [pdf] - 585603
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Comments: 21 pages, 11 figures, presented at SPIE Astronomical Telescopes and Instrumentation 2012
Submitted: 2012-11-03
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.
[32]  oai:arXiv.org:1208.0871  [pdf] - 1150517
A titanium-nitride near-infrared kinetic inductance photon-counting detector and its anomalous electrodynamics
Comments: 4 pages, 3 figures
Submitted: 2012-08-03
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation response shows a shorter decay time than the frequency response at low temperatures. We suggest that the observed anomalous electrodynamics may be related to quasiparticle traps or subgap states in the disordered TiN films. Finally, the electron density-of-states is derived from the pulse response.
[33]  oai:arXiv.org:1203.5861  [pdf] - 698662
A readout for large arrays of Microwave Kinetic Inductance Detectors
Comments:
Submitted: 2012-03-26
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at microwave frequencies, allowing the construction and readout of large arrays. Due to the microwave FDM, MKIDs do not require the complex cryogenic multiplexing electronics used for similar detectors, such as Transition Edge Sensors (TESs), but instead transfer this complexity to room temperature electronics where they present a formidable signal processing challenge. In this paper we describe the first successful effort to build a readout for a photon counting optical/near-IR astronomical instrument, the ARray Camera for Optical to Near-infrared Spectrophotometry (ARCONS). This readout is based on open source hardware developed by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER). Designed principally for radio telescope backends, it is flexible enough to be used for a variety of signal processing applications.
[34]  oai:arXiv.org:1201.5904  [pdf] - 1093317
ARCONS: a highly multiplexed superconducting UV to near-IR camera
Comments: To appear in the proceedings of IAU symposium number 285; New Horizons in Time Domain Astronomy, eds. R.E.M Griffin, R. J. Hanisch & R. Seaman
Submitted: 2012-01-27
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was recently commissioned at the Coude focus of the 200-inch Hale Telescope at the Palomar Observatory. At the heart of this unique instrument is a 1024-pixel Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance effect to measure the energy of the incoming photon to better than several percent. The ground-breaking instrument is lens-coupled with a pixel scale of 0.23"/pixel, with each pixel recording the arrival time (<2 microsec) and energy of a photon (~10%) in the optical to near-IR (0.4-1.1 microns) range. The scientific objectives of the instrument include the rapid follow-up and classification of the transient phenomena.
[35]  oai:arXiv.org:1112.0004  [pdf] - 471685
A superconducting focal plane array for ultraviolet, optical, and near-infrared astrophysics
Comments: 9 pages, 5 figures, accepted for publication in Optics Express
Submitted: 2011-11-30
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectrum as well as a particle detector. Here we describe the first successful effort to create a photon-counting, energy-resolving ultraviolet, optical, and near infrared MKID focal plane array. These new Optical Lumped Element (OLE) MKID arrays have significant advantages over semiconductor detectors like charge coupled devices (CCDs). They can count individual photons with essentially no false counts and determine the energy and arrival time of every photon with good quantum efficiency. Their physical pixel size and maximum count rate is well matched with large telescopes. These capabilities enable powerful new astrophysical instruments usable from the ground and space. MKIDs could eventually supplant semiconductor detectors for most astronomical instrumentation, and will be useful for other disciplines such as quantum optics and biological imaging.
[36]  oai:arXiv.org:1007.0752  [pdf] - 1033500
ARCONS: A highly multiplexed superconducting optical to near-IR camera
Comments: 10 pages, 5 figures. To appear in Proc. SPIE Astronomical Telescopes and Instrumentation, San Diego, 2010
Submitted: 2010-07-05
We report on the development of ARCONS, the ARray Camera for Optical to Near-IR Spectrophotometry. This photon counting integral field unit (IFU), being built at UCSB and Caltech with detectors fabricated at JPL, will use a unique, highly multiplexed low temperature detector technology known as Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate at 100 mK, should provide photon counting with energy resolution of R = E/{\delta}E > 20 and time resolution of a microsecond, with a quantum efficiency of around 50%. We expect to field the instrument at the Palomar 200" telescope in the first quarter of 2011 with an array containing 1024 pixels in a 32x32 pixel form factor to yield a field of view of approximately 10x10 arcseconds. The bandwidth of the camera is limited by the rising sky count rate at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 {\mu}m will be achievable. A simple optical path and compact dewar utilizing a cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A highly expandable software defined radio (SDR) readout that can scale up to much larger arrays has been developed.
[37]  oai:arXiv.org:cond-mat/0610130  [pdf] - 110417
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
Comments: 4 pages, 2 figures. Submitted to Applied Physics Letters, August 25, 2006
Submitted: 2006-10-04
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon energy to the MKID. We present results on position sensitive X-ray detectors made by using two aluminum MKIDs on either side of a tantalum photon absorber strip. Diffusion constants, recombination times, and energy resolution are reported. MKIDs can easily be scaled into large arrays.
[38]  oai:arXiv.org:astro-ph/0307544  [pdf] - 58257
Optical Pulse-Phased Photopolarimetry of PSR B0656+14
Comments: 27 pages, 11 figures, accepted by ApJ (scheduled v597 n2, November 10, 2003)
Submitted: 2003-07-30
We have observed the optical pulse profile of PSR B0656+14 in 10 phase bins at a high signal-to-noise ratio, and have measured the linear polarization profile over 30% of the pulsar period with some significance. The pulse profile is double-peaked, with a bridge of emission between the two peaks, similar to gamma-ray profiles observed in other pulsars. There is no detectable unpulsed flux, to a 1-sigma limit of 16% of the pulse-averaged flux. The emission in the bridge is highly (~ 100%) polarized, with a position angle sweep in excellent agreement with the prediction of the Rotating Vector Model as determined from radio polarization observations. We are able to account for the gross features of the optical light curve (i.e., the phase separation of the peaks) using both polar cap and outer gap models. Using the polar cap model, we are also able to estimate the height of the optical emission regions.
[39]  oai:arXiv.org:astro-ph/0007420  [pdf] - 37258
Simulated Extragalactic Observations with a Cryogenic Imaging Spectrophotometer
Comments: 30 pages, 10 figures, accepted for publication in the Astronomical Journal
Submitted: 2000-07-27
In this paper we explore the application of cryogenic imaging spectrophotometers. Prototypes of this new class of detector, such as superconducting tunnel junctions (STJs) and transition edge sensors (TESs), currently deliver low resolution imaging spectrophotometry with high quantum efficiency (70-100%) and no read noise over a wide bandpass in the visible to near-infrared. In order to demonstrate their utility and the differences in observing strategy needed to maximize their scientific return, we present simulated observations of a deep extragalactic field. Using a simple analytic technique, we can estimate both the galaxy redshift and spectral type more accurately than is possible with current broadband techniques. From our simulated observations and a subsequent discussion of the expected migration path for this new technology, we illustrate the power and promise of these devices.