sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Malasan, Hakim L.

Normalized to: Malasan, H.

3 article(s) in total. 46 co-authors. Median position in authors list is 3,0.

[1]  oai:arXiv.org:1512.07206  [pdf] - 1613042
Statistical Improvement in Detection Level of Gravitational Microlensing Events from their Light Curves
Comments: 19 pages, 13 figures, and 5 tables, accepted RAA: 13 December 2017
Submitted: 2015-12-21, last modified: 2018-01-03
In Astronomy, the brightness of a source is typically expressed in terms of magnitude. Conventionally, the magnitude is defined by the logarithm of the received flux. This relationship is known as the Pogson formula. For received flux with a small signal to noise ratio (S/N), however, the formula gives a large magnitude error. We investigate whether the use of Inverse Hyperbolic Sine function (after this referred to as the Asinh magnitude) in the modified formulae could allow for an alternative calculation of magnitudes for small S/N flux, and whether the new approach is better for representing the brightness of that region. We study the possibility of increasing the detection level of gravitational microlensing using 40 selected microlensing light curves from 2013 and 2014 season and by using the Asinh magnitude. The photometric data of the selected events is obtained from the Observational Gravitational Lensing Experiment (OGLE). We found that the utilization of the Asinh magnitude makes the events brighter compared to using the logarithmic magnitude, with an average of about $3.42 \times10^{-2}$ magnitude and the average of the difference of error between the logarithmic and the Asinh magnitude is about $2.21 \times10^{-2}$ magnitude. The microlensing events, OB 140847 and OB 140885 are found to have the largest difference values among the selected events. Using a Gaussian fit to find the peak for OB140847 and OB140885, we conclude statistically that the Asinh magnitude gives better mean squared values of the regression and narrower residual histograms than the Pogson magnitude. Based on these results, we also attempt to propose a limit of magnitude value from which the use of the Asinh magnitude is optimal for small S/N data.
[2]  oai:arXiv.org:0810.5607  [pdf] - 18046
Science with UT's Dichroic-Mirror Camera (DMC), 15-band simultaneous imager
Comments: 3 pages 6 figures Proceedings of 10th Asian-Pacific Regional IAU Meeting
Submitted: 2008-10-30
We introduce the Dichroic-Mirror Camera (DMC), an instrument developed at the University of Tokyo which is capable of performing simultaneous imaging in fifteen bands. The main feature of the DMC is the dichroic mirrors, which split incoming light into red and blue components. Combination of dichroic mirrors split light from the telescope focus into fifteen intermediate-width bands across 390 -- 950 nm. The fifteen bands of DMC provide measurements of the object's spectral energy distribution (SED) at fifteen wavelength points. During May -- June 2007 and March 2008, observing run of the DMC was carried out at Higashi-Hiroshima Observatory, Japan. We observed several objects i.e. planets, asteroids, standard stars & star clusters, planetary nebulae, galaxies, and supernovae. We describe several early scientific results from the DMC.
[3]  oai:arXiv.org:astro-ph/9609024  [pdf] - 95344
Asteroseismological Observations of the Central Star of the Planetary Nebula NGC 1501
Comments: 12 pages, AASTEX, 7 tables, 6 EPS figures, to appear in AJ, 12/96 Corrected version repairs table formatting and adds missing Table 7
Submitted: 1996-09-03, last modified: 1996-09-06
We report on a global CCD time-series photometric campaign to decode the pulsations of the nucleus of the planetary nebula NGC1501. The star is hot and hydrogen-deficient, similar to the pre-white-dwarf PG 1159 stars. NGC1501 shows pulsational brightness variations of a few percent with periods ranging from 19 to 87 minutes. The variations are very complex, suggesting a pulsation spectrum that requires a long unbroken time series to resolve. Our CCD photometry of the star covers a two-week period in 1991 November, and used a global network of observatories. We obtained nearly continuous coverage over an interval of one week in the middle of the run. We have identified 10 pulsation periods, ranging from 5235 s down to 1154 s. We find strong evidence that the modes are indeed nonradial g-modes. The ratios of the frequencies of the largest-amplitude modes agree with those expected for modes that are trapped by a density discontinuity in the outer layers. We offer a model for the pulsation spectrum that includes a common period spacing of 22.3 s and a rotation period of 1.17 days; the period spacing allows us to assign a seismological mass of 0.55+/-0.03 Msun.