Normalized to: Kouno, H.
[1]
oai:arXiv.org:1307.0681 [pdf] - 698746
Determination of quark-hadron transition from lattice QCD and
neutron-star observation
Submitted: 2013-07-02, last modified: 2013-07-26
We determine the quark-hadron transition line in the whole region of
temperature (T) and baryon-number chemical potential (\mu_B) from lattice QCD
results and neutron-star mass measurements, making the quark-hadron hybrid
model that is consistent with the two solid constraints. The quark part of the
hybrid model is the Polyakov-loop extended Nambu-Jona-Lasinio (PNJL) model with
entanglement vertex that reproduces lattice QCD results at mu_B/T=0, while the
hadron part is the hadron resonance gas model with volume-exclusion effect that
reproduces neutron-star mass measurements and the neutron-matter equation of
state calculated from two- and three-nucleon forces based on the chiral
effective field theory. The lower bound of the critical mu_B of the
quark-hadron transition at zero T is mu_B = 1.6 GeV. The interplay between the
heavy-ion collision physics around mu_B/T =6 and the neutron-star physics where
mu_B/T is infinity is discussed.
[2]
oai:arXiv.org:nucl-th/0407004 [pdf] - 118705
Effective meson masses, effective meson-nucleon couplings and neutron
star radii
Submitted: 2004-07-01
Using the generalized mean field theory, we have studied the relation among
the effective meson masses, the effective meson-nucleon couplings and the
equation of state (EOS) in asymmetric nuclear matter. If the effective
omega-meson mass becomes smaller at high density, the EOS becomes stiffer.
However, if we require that the omega-meson mean field is proportional to the
baryon density, the effective omega-nucleon coupling automatically becomes
smaller at the same time as the effective omega-meson mass becomes smaller.
Consequently, the EOS becomes softer. A similar relation is found for the
effective rho-meson mass and the effective rho-nucleon coupling. We have also
studied the relation among the effective meson masses, the effective
meson-nucleon couplings and a radius R of a neutron star. The R depends
somewhat on the value of the effective omega-meson mass and the effective
omega-nucleon coupling.
[3]
oai:arXiv.org:physics/0208090 [pdf] - 118996
Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of
the Monitor of All-sky X-ray Image mission onboard the International Space
Station: I. Experimental Setup and Measurement of the Charge Transfer
Inefficiency
Miyata, E.;
Kamazuka, T.;
Kouno, H.;
Mihara, M. Fukuda M.;
Matsuta, K.;
Tsunemi, H.;
Tanaka, K.;
Minamisono, T;
Tomida, H.;
Miyaguchi, K.
Submitted: 2002-08-26
We have investigated the radiation damage effects on a CCD to be employed in
the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray
Image (MAXI) onboard the International Space Station (ISS). Since low energy
protons release their energy mainly at the charge transfer channel, resulting a
decrease of the charge transfer efficiency, we thus focused on the low energy
protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to
a given device. We measured the degradation of the charge transfer inefficiency
(CTI) as a function of incremental fluence. A 292 keV proton beam degraded the
CTI most seriously. Taking into account the proton energy dependence of the
CTI, we confirmed that the transfer channel has the lowest radiation tolerance.
We have also developed the different device architectures to reduce the
radiation damage in orbit. Among them, the ``notch'' CCD, in which the buried
channel implant concentration is increased, resulting in a deeper potential
well than outside, has three times higher radiation tolerance than that of the
normal CCD. We then estimated the charge transfer inefficiency of the CCD in
the orbit of ISS, considering the proton energy spectrum. The CTI value is
estimated to be 1.1e-5 per each transfer after two years of mission life in the
worse case analysis if the highest radiation-tolerant device is employed. This
value is well within the acceptable limit and we have confirmed the high
radiation-tolerance of CCDs for the MAXI mission.
[4]
oai:arXiv.org:physics/0206021 [pdf] - 118991
Application of the Mesh Experiment for the Back-Illuminated CCD: I.
Experiment and the Charge Cloud Shape
Submitted: 2002-06-09
We have employed a mesh experiment for back-illuminated (BI) CCDs. BI CCDs
possess the same structure to those of FI CCDs. Since X-ray photons enter from
the back surface of the CCD, a primary charge cloud is formed far from the
electrodes. The primary charge cloud expands through diffusion process until it
reaches the potential well that is just below the electrodes. Therefore, the
diffusion time for the charge cloud produced is longer than that in the FI CCD,
resulting a larger charge cloud shape expected.
The mesh experiment enables us to specify the X-ray point of interaction with
a subpixel resolution. We then have measured a charge cloud shape produced in
the BI CCD. We found that there are two components of the charge cloud shape
having different size: a narrow component and a broad component. The size of
the narrow component is $2.8-5.7 \mu$m in unit of a standard deviation and
strongly depends on the attenuation length in Si of incident X-rays. The
shorter the attenuation length of X-rays is, the larger the charge cloud
becomes. This result is qualitatively consistent with a diffusion model inside
the CCD. On the other hand, the size of the broad component is roughly constant
of $\simeq 13 \mu$m and does not depend on X-ray energies. Judging from the
design value of the CCD and the fraction of each component, we conclude that
the narrow component is originated in the depletion region whereas the broad
component is in the field-free region.
[5]
oai:arXiv.org:astro-ph/0204014 [pdf] - 48559
Direct X-ray Imaging of $\mu$m precision using Back-Illuminated CCD
Submitted: 2002-04-01
A charge-coupled device (CCD) is a standard imager in optical region in which
the image quality is limited by its pixel size. CCDs also function in X-ray
region but with substantial differences in performance. An optical photon
generates only one electron while an X-ray photon generates many electrons at a
time. We developed a method to precisely determine the X-ray point of
interaction with subpixel resolution. In particular, we found that a
back-illuminated CCD efficiently functions as a fine imager. We present here
the validity of our method through an actual imaging experiment.