Normalized to: Hollister, M.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:2001.08887 [pdf] - 2037597
Thermal Kinetic Inductance Detectors for Millimeter-Wave Astrophysics
Wandui, Albert;
Bock, Jamie;
Frez, Clifford;
Hollister, Matthew;
Minutolo, Lorenzo;
Nguyen, Hien;
Steinbach, Bryan;
Turner, Anthony;
Zmuidzinas, Jonas;
O'Brient, Roger
Submitted: 2020-01-24
Thermal Kinetic Inductance Detectors (TKIDs) combine the excellent noise
performance of traditional bolometers with a radio frequency (RF) multiplexing
architecture that enables the large detector counts needed for the next
generation of millimeter-wave instruments. Here we present dark prototype TKID
pixels that demonstrate a noise equivalent power NEP = $2 \times 10^{-17}
\mathrm{W}/\mathrm{\sqrt{Hz}} $ with a $1/f$ knee at 0.1 Hz, suitable for
background-limited noise performance at 150 GHz from a ground-based site. We
discuss the optimizations in the device design and fabrication techniques to
realize optimal electrical performance and high quality factors at a bath
temperature of 250 mK.
[3]
oai:arXiv.org:1802.04854 [pdf] - 1701561
Stacked Wafer Gradient Index Silicon Optics with Integral
Anti-reflection Layers
Defrance, F.;
Chattopadhyay, G.;
Connors, J.;
Golwala, S.;
Hollister, M. I.;
Jung-Kubiak, C.;
Padilla, E.;
Radford, S.;
Sayers, J.;
Tong, E. C.;
Yoshida, H.
Submitted: 2018-02-13, last modified: 2018-06-18
Silicon optics with wide bandwidth anti-reflection (AR) coatings, made of
multi-layer textured silicon surfaces, are developed for millimeter and
submillimeter wavelengths. Single and double layer AR coatings were designed
for an optimal transmission centered on 250 GHz, and fabricated using the DRIE
(Deep Reaction Ion Etching) technique. Tests of high resistivity silicon wafers
with single-layer coatings between 75 GHz and 330 GHz are presented and
compared with the simulations.
[4]
oai:arXiv.org:1803.05168 [pdf] - 1700956
A 1.6:1 Bandwidth Two-Layer Antireflection Structure for Silicon Matched
to the 190-310 GHz Atmospheric Window
Defrance, Fabien;
Jung-Kubiak, Cecile;
Sayers, Jack;
Connors, Jake;
deYoung, Clare;
Hollister, Matthew I.;
Yoshida, Hiroshige;
Chattopadhyay, Goutam;
Golwala, Sunil R.;
Radford, Simon J. E.
Submitted: 2018-03-14, last modified: 2018-05-28
Although high-resistivity, low-loss silicon is an excellent material for THz
transmission optics, its high refractive index necessitates antireflection
treatment. We fabricated a wide-bandwidth, two-layer antireflection treatment
by cutting subwavelength structures into the silicon surface using multi-depth
deep reactive ion etching (DRIE). A wafer with this treatment on both sides has
<-20 dB (<1%) reflectance over 190-310 GHz. We also demonstrated that bonding
wafers introduces no reflection features above the -20 dB level, reproducing
previous work. Together these developments immediately enable construction of
wide-bandwidth silicon vacuum windows and represent two important steps toward
gradient-index silicon optics with integral broadband antireflection treatment.
[5]
oai:arXiv.org:1803.02470 [pdf] - 1686778
Development of Aluminum LEKIDs for Balloon-Borne Far-IR Spectroscopy
Submitted: 2018-03-06, last modified: 2018-04-16
We are developing lumped-element kinetic inductance detectors (LEKIDs)
designed to achieve background-limited sensitivity for far-infrared (FIR)
spectroscopy on a stratospheric balloon. The Spectroscopic Terahertz Airborne
Receiver for Far-InfraRed Exploration (STARFIRE) will study the evolution of
dusty galaxies with observations of the [CII] 158 $\mu$m and other atomic
fine-structure transitions at $z=0.5-1.5$, both through direct observations of
individual luminous infrared galaxies, and in blind surveys using the technique
of line intensity mapping. The spectrometer will require large format
($\sim$1800 detectors) arrays of dual-polarization sensitive detectors with
NEPs of $1 \times 10^{-17}$ W Hz$^{-1/2}$. The low-volume LEKIDs are fabricated
with a single layer of aluminum (20 nm thick) deposited on a crystalline
silicon wafer, with resonance frequencies of $100-250$ MHz. The inductor is a
single meander with a linewidth of 0.4 $\mu$m, patterned in a grid to absorb
optical power in both polarizations. The meander is coupled to a circular
waveguide, fed by a conical feedhorn. Initial testing of a small array
prototype has demonstrated good yield, and a median NEP of $4 \times 10^{-18}$
W Hz$^{-1/2}$.
[6]
oai:arXiv.org:1509.02950 [pdf] - 1385376
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements
Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Sayers, Jack;
Zemcov, Michael;
Glenn, Jason;
Golwala, Sunil R.;
Maloney, Philip R.;
Siegel, Seth R.;
Wheeler, Jordan;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran P.;
Gao, Jiansong;
Hollister, Matthew I.;
Lam, Albert;
LeDuc, Henry G.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David A.;
Mroczkowski, Tony K.;
Noroozian, Omid;
Nguyen, Hien T.;
Radford, Simon J.;
Schlaerth, James A.;
Vayonakis, Anastasios;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2015-09-09, last modified: 2016-03-01
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images
towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech
Submillimeter Observatory with the Multiwavelength Submillimeter Inductance
Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As
part of our analysis, we have used higher frequency data from Herschel-SPIRE
and previously published lower frequency radio data to subtract the signal from
the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the
AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined
with X-ray spectroscopic measurements of the temperature of the intra-cluster
medium (ICM) from Chandra, we constrain the ICM optical depth to be $\tau_e =
7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar
velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both
quantities are limited by measurement noise rather than calibration
uncertainties or astrophysical contamination, and significant improvements are
possible with deeper observations. Our best-fit velocity is in good agreement
with one previously published SZ effect analysis and in mild tension with the
other, although some or all of that tension may be because that measurement
samples a much smaller cluster volume. Furthermore, our best-fit optical depth
implies a gas mass slightly larger than the Chandra-derived value, implying the
cluster is elongated along the line of sight.
[7]
oai:arXiv.org:1511.04488 [pdf] - 1347622
Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip
Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chapman, S.;
Che, G.;
Glenn, J.;
Hollister, M.;
Kovács, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Shiu, C.;
Tucker, C. E.;
Wheeler, J.;
Williamson, R.;
Zmuidzinas, J.
Submitted: 2015-11-13
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100 - 200 MHz. We have tested a new prototype device that achieves the targeted
R = 100 resolving power, and has better detector sensitivity and optical
efficiency than previous devices. We employ a new method for measuring photon
noise using both coherent and thermal sources of radiation to cleanly separate
the contributions of shot and wave noise. We report an upper limit to the
detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon
noise limited NEP for a ground-based R=100 spectrometer.
[8]
oai:arXiv.org:1501.02295 [pdf] - 1223953
Status of SuperSpec: A Broadband, On-Chip Millimeter-Wave Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chattopadhyay, G.;
Day, P.;
Doyle, S.;
Hollister, M.;
Kovacs, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C. M.;
Monroe, R.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Swenson, L.;
Tucker, C. E.;
Zmuidzinas, J.
Submitted: 2015-01-09
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100-200 MHz. We have tested a new prototype device that is more sensitive than
previous devices, and easier to fabricate. We present a characterization of a
representative R=282 channel at f = 236 GHz, including measurements of the
spectrometer detection efficiency, the detector responsivity over a large range
of optical loading, and the full system optical efficiency. We outline future
improvements to the current system that we expect will enable construction of a
photon-noise-limited R=100 filter bank, appropriate for a line intensity
mapping experiment targeting the [CII] 158 micron transition during the Epoch
of Reionization
[9]
oai:arXiv.org:1301.3650 [pdf] - 832812
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell
Telescope
Holland, W. S.;
Bintley, D.;
Chapin, E. L.;
Chrysostomou, A.;
Davis, G. R.;
Dempsey, J. T.;
Duncan, W. D.;
Fich, M.;
Friberg, P.;
Halpern, M.;
Irwin, K. D.;
Jenness, T.;
Kelly, B. D.;
MacIntosh, M. J.;
Robson, E. I.;
Scott, D.;
Ade, P. A. R.;
Atad-Ettedgui, E.;
Berry, D. S.;
Craig, S. C.;
Gao, X.;
Gibb, A. G.;
Hilton, G. C.;
Hollister, M. I.;
Kycia, J. B.;
Lunney, D. W.;
McGregor, H.;
Montgomery, D.;
Parkes, W.;
Tilanus, R. P. J.;
Ullom, J. N.;
Walther, C. A.;
Walton, A. J.;
Woodcraft, A. L.;
Amiri, M.;
Atkinson, D.;
Burger, B.;
Chuter, T.;
Coulson, I. M.;
Doriese, W. B.;
Dunare, C.;
Economou, F.;
Niemack, M. D.;
Parsons, H. A. L.;
Reintsema, C. D.;
Sibthorpe, B.;
Smail, I.;
Sudiwala, R.;
Thomas, H. S.
Submitted: 2013-01-16
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at
submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The
camera has the capability to carry out wide-field surveys to unprecedented
depths, addressing key questions relating to the origins of galaxies, stars and
planets. With two imaging arrays working simultaneously in the atmospheric
windows at 450 and 850 microns, the vast increase in pixel count means that
SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument.
In this paper we present an overview of the instrument, discuss the physical
characteristics of the superconducting detector arrays, outline the observing
modes and data acquisition, and present the early performance figures on the
telescope. We also showcase the capabilities of the instrument via some early
examples of the science SCUBA-2 has already undertaken. In February 2012,
SCUBA-2 began a series of unique legacy surveys for the JCMT community. These
surveys will take 2.5 years and the results are already providing complementary
data to the shorter wavelength, shallower, larger-area surveys from Herschel.
The SCUBA-2 surveys will also provide a wealth of information for further study
with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
[10]
oai:arXiv.org:1211.1652 [pdf] - 587352
MKID development for SuperSpec: an on-chip, mm-wave, filter-bank
spectrometer
Shirokoff, Erik;
Barry, Peter S.;
Bradford, Charles M.;
Chattopadhyay, Goutam;
Day, Peter;
Doyle, Simon;
Hailey-Dunsheath, Steve;
Hollister, Matthew I.;
Kovács, Attila;
McKenney, Christopher;
Leduc, Henry G.;
Llombart, Nuria;
Marrone, Daniel P.;
Mauskopf, Philip;
O'Brient, Roger;
Padin, Stephen;
Reck, Theodore;
Swenson, Loren J.;
Zmuidzinas, Jonas
Submitted: 2012-11-07
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and
submillimeter wavelength astronomy. Its very small size, wide spectral
bandwidth, and highly multiplexed readout will enable construction of powerful
multibeam spectrometers for high-redshift observations. The spectrometer
consists of a horn-coupled microstrip feedline, a bank of narrow-band
superconducting resonator filters that provide spectral selectivity, and
Kinetic Inductance Detectors (KIDs) that detect the power admitted by each
filter resonator. The design is realized using thin-film lithographic
structures on a silicon wafer. The mm-wave microstrip feedline and spectral
filters of the first prototype are designed to operate in the band from 195-310
GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed
to operate at hundreds of MHz and are fabricated from titanium nitride with a
Tc of 2K. Radiation incident on the horn travels along the mm-wave microstrip,
passes through the frequency-selective filter, and is finally absorbed by the
corresponding KID where it causes a measurable shift in the resonant frequency.
In this proceedings, we present the design of the KIDs employed in SuperSpec
and the results of initial laboratory testing of a prototype device. We will
also briefly describe the ongoing development of a demonstration instrument
that will consist of two 500-channel, R=700 spectrometers, one operating in the
1-mm atmospheric window and the other covering the 650 and 850 micron bands.
[11]
oai:arXiv.org:1211.0934 [pdf] - 585657
SuperSpec: design concept and circuit simulations
Kovács, Attila;
Barry, Peter S.;
Bradford, Charles M.;
Chattopadhyay, Goutam;
Day, Peter;
Doyle, Simon;
Hailey-Dunsheath, Steve;
Hollister, Matthew;
McKenney, Christopher;
LeDuc, Henry G.;
Llombart, Nuria;
Marrone, Daniel P.;
Mauskopf, Philip;
O'Brient, Roger;
Padin, Stephen;
Swenson, Loren J.;
Zmuidzinas, Jonas
Submitted: 2012-11-05
SuperSpec is a pathfinder for future lithographic spectrometer cameras, which
promise to energize extra-galactic astrophysics at (sub)millimeter wavelengths:
delivering 200--500 km/s spectral velocity resolution over an octave bandwidth
for every pixel in a telescope's field of view. We present circuit simulations
that prove the concept, which enables complete millimeter-band spectrometer
devices in just a few square-millimeter footprint. We evaluate both
single-stage and two-stage channelizing filter designs, which separate channels
into an array of broad-band detectors, such as bolometers or kinetic inductance
detector (KID) devices. We discuss to what degree losses (by radiation or by
absorption in the dielectric) and fabrication tolerances affect the resolution
or performance of such devices, and what steps we can take to mitigate the
degradation. Such design studies help us formulate critical requirements on the
materials and fabrication process, and help understand what practical limits
currently exist to the capabilities these devices can deliver today or over the
next few years.
[12]
oai:arXiv.org:1211.0595 [pdf] - 585603
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Golwala, Sunil R.;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran;
Gao, Jiansong;
Gill, Amandeep K.;
Glenn, Jason;
Hollister, Matthew I.;
LeDuc, Henry G.;
Maloney, Philip R.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David;
Noroozian, Omid;
Nguyen, Hien T.;
Sayers, Jack;
Schlaerth, James A.;
Siegel, Seth;
Vayonakis, Anastasios K.;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2012-11-03
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance
Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is
designed to have a 14', diffraction-limited field-of-view instrumented with
2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04,
1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies,
galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own
and nearby galaxies. MUSIC uses broadband superconducting phased-array
slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to
define spectral bands, and microwave kinetic inductance detectors to
senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72
spatial pixels each. It is coupled to the telescope via an ambient temperature
ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the
image of the primary mirror formed by the ellipsoidal mirror. Dielectric and
metal mesh filters are used to block thermal infrared and out-of-band
radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle
cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates
Earth's magnetic field. Each focal plane tile is read out by a single pair of
coaxes and a HEMT amplifier. The readout system consists of 16 copies of
custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We
focus on recent updates on the instrument design and results from the
commissioning of the full camera in 2012.
[13]
oai:arXiv.org:1211.0315 [pdf] - 585017
MAKO: a pathfinder instrument for on-sky demonstration of low-cost 350
micron imaging arrays
Swenson, Loren J.;
Day, Peter K.;
Dowell, Charles D.;
Eom, Byeong H.;
Hollister, Matthew I.;
Jarnot, Robert;
Kovãcs, Attila;
Leduc, Henry G.;
McKenney, Christopher M.;
Monroe, Ryan;
Mroczkowski, Tony;
Nguyen, Hien T.;
Zmuidzinas, Jonas
Submitted: 2012-11-01
Submillimeter cameras now have up to $10^4$ pixels (SCUBA 2). The proposed
CCAT 25-meter submillimeter telescope will feature a 1 degree field-of-view.
Populating the focal plane at 350 microns would require more than $10^6$
photon-noise limited pixels. To ultimately achieve this scaling, simple
detectors and high-density multiplexing are essential. We are addressing this
long-term challenge through the development of frequency-multiplexed
superconducting microresonator detector arrays. These arrays use
lumped-element, direct-absorption resonators patterned from titanium nitride
films. We will discuss our progress toward constructing a scalable 350 micron
pathfinder instrument focusing on fabrication simplicity, multiplexing density,
and ultimately a low per-pixel cost.
[14]
oai:arXiv.org:astro-ph/0606338 [pdf] - 82778
SCUBA-2: a 10,000 pixel submillimeter camera for the James Clerk Maxwell
Telescope
Holland, Wayne;
MacIntosh, Michael;
Fairley, Alasdair;
Kelly, Dennis;
Montgomery, David;
Gostick, David;
Atad-Ettedgui, Eli;
Ellis, Maureen;
Robson, Ian;
Hollister, Matthew;
Woodcraft, Adam;
Ade, Peter;
Walker, Ian;
Irwin, Kent;
Hilton, Gene;
Duncan, William;
Reintsema, Carl;
Walton, Anthony;
Parkes, William;
Dunare, Camelia;
Fich, Michel;
Kycia, Jan;
Halpern, Mark;
Scott, Douglas;
Gibb, Andy;
Molnar, Janos;
Chapin, Ed;
Bintley, Dan;
Craig, Simon;
Chylek, Tomas;
Jenness, Tim;
Economou, Frossie;
Davis, Gary
Submitted: 2006-06-14
SCUBA-2 is an innovative 10,000 pixel submillimeter camera due to be
delivered to the James Clerk Maxwell Telescope in late 2006. The camera is
expected to revolutionize submillimeter astronomy in terms of the ability to
carry out wide-field surveys to unprecedented depths addressing key questions
relating to the origins of galaxies, stars and planets. This paper presents an
update on the project with particular emphasis on the laboratory commissioning
of the instrument. The assembly and integration will be described as well as
the measured thermal performance of the instrument. A summary of the
performance results will be presented from the TES bolometer arrays, which come
complete with in-focal plane SQUID amplifiers and multiplexed readouts, and are
cooled to 100mK by a liquid cryogen-free dilution refrigerator. Considerable
emphasis has also been placed on the operating modes of the instrument and the
common-user aspect of the user interface and data reduction pipeline. These
areas will also be described in the paper.