Normalized to: Haze, K.
[1]
oai:arXiv.org:1710.00108 [pdf] - 1686641
Laboratory demonstration of a cryogenic deformable mirror for wavefront
correction of space-borne infrared telescopes
Takahashi, Aoi;
Enya, Keigo;
Haze, Kanae;
Kataza, Hirokazu;
Kotani, Takayuki;
Matsuhara, Hideo;
Kamiya, Tomohiro;
Yamamuro, Tomoyasu;
Bierden, Paul;
Cornelissen, Steven;
Lam, Charlie;
Feinberg, Michael
Submitted: 2017-09-29
This paper demonstrates a cryogenic deformable mirror (DM) with 1,020
actuators based on micro-electrical mechanical systems (MEMS) technology.
Cryogenic space-borne infrared telescopes can experience a wavefront error due
to a figure error of their mirror surface, which makes the imaging performance
worse. For on-orbit wavefront correction as one solution, we developed a
MEMS-processed electro-static DM with a special surrounding structure for use
under the cryogenic temperature. We conducted a laboratory demonstration of its
operation in three cooling cycles between 5 K and 295 K. Using a laser
interferometer, we detected the deformation corresponding to the applied
voltages under the cryogenic temperature for the first time. The relationship
between voltages and displacements was qualitatively expressed by the quadratic
function, which is assumed based on the principle of electro-static DMs. We
also found that it had a high operating repeatability of a few nm RMS and no
significant hysteresis. Using the measured values of repeatability, we
simulated the improvement of PSF by wavefront correction with our DM. These
results show that our developed DM is effective in improving imaging
performance and PSF contrast of space-borne infrared telescopes.
[2]
oai:arXiv.org:1603.09374 [pdf] - 1383745
Experimental demonstration of binary shaped pupil mask coronagraphs for
telescopes with obscured pupils
Submitted: 2016-03-30
We present the fabrication and experimental demonstration of three
free-standing binary shaped pupil mask coronagraphs, which are applicable for
telescopes with partially obscured pupils. Three masks, designed to be
complementary (labeled Mask-A, Mask-B, and Mask-C), were formed in 5 micron
thick nickel. The design of Mask-A is based on a one-dimensional barcode mask.
The design principle of Mask-B is similar, but has a smaller inner working
angle and a lower contrast than Mask-A. Mask-C is based on a concentric ring
mask and provides the widest dark region and a symmetric point spread function.
Mask-A and Mask-C were both designed to produce a flexibly tailored dark region
(i.e., non-uniform contrast). The contrast was evaluated using a light source
comprising a broadband super-luminescent light-emitting diode with a center
wavelength of 650 nm, and the measurements were carried out in a large vacuum
chamber. Active wavefront control was not applied in this work. The
coronagraphic images obtained by experiment were mostly consistent with the
designs. The contrast of Mask-A within the ranges 3.3 - 8 lambda/D and 8 - 12
lambda/D was ~10^{-4} - 10^{-7} and ~10^{-7}, respectively, where lambda is the
wavelength and D is the pupil diameter. The contrast close to the center of
Mask-B was ~10^{-4} and that of Mask-C over an extended field of view (5 - 25
lambda/D) was ~10^{-5} - 10^{-6}. The effect of tilting the masks was
investigated, and found to be irrelevant at the ~10^{-7} contrast level.
Therefore the masks can be tilted to avoid ghosting. These high-contrast
free-standing masks have the potential to enable coronagraphic imaging over a
wide wavelength range using both ground-based and space-borne general-purpose
telescopes with pupil structures not specifically designed for coronagraphy.
[3]
oai:arXiv.org:1509.01411 [pdf] - 1370209
Coronagraphic demonstration experiment using aluminum mirrors for space
infrared astronomical observations
Oseki, Shinji;
Oyabu, Shinki;
Ishihara, Daisuke;
Enya, Keigo;
Haze, Kanae;
Kotani, Takayuki;
Kaneda, Hidehiro;
Nishiyama, Miho;
Abe, Lyu;
Yamamuro, Tomoyasu
Submitted: 2015-09-04
For future space infrared astronomical coronagraphy, we perform experimental
studies on the application of aluminum mirrors to a coronagraph. Cooled
reflective optics is required for broad-band mid-infrared observations in
space, while high-precision optics is required for coronagraphy. For the
coronagraph instrument originally proposed for the next-generation infrared
astronomical satellite project SPICA (SCI: SPICA Coronagraph Instrument), we
fabricated and evaluated the optics consisting of high-precision aluminum
off-axis mirrors with diamond-turned surfaces, and conducted a coronagraphic
demonstration experiment using the optics with a coronagraph mask. We first
measured the wave front errors (WFEs) of the aluminum mirrors with a He-Ne
Fizeau interferometer to confirm that the power spectral densities of the WFEs
satisfy the SCI requirements. Then we integrated the mirrors into an optical
system and evaluated the overall performance of the system. As a result, we
estimate the total WFE of the optics to be 33 nm (rms), each mirror
contributing 10-20 nm (rms) for the central 14 mm area of the optics, and
obtain a contrast of 10^(-5.4) as a coronagraph in the visible light. At a
wavelength of 5 um, the coronagraphic system is expected to achieve a contrast
of ~10^(-7) based on our model calculation with the measured optical
performance. Thus our experiment demonstrates that aluminum mirror optics is
applicable to a highly WFE-sensitive instrument such as a coronagraph in space.
[4]
oai:arXiv.org:1206.0349 [pdf] - 1123842
Comparative study of manufacturing techniques for coronagraphic binary
pupil masks: masks on substrates and free-standing masks
Submitted: 2012-06-02
We present a comparative study of the manufacture of binary pupil masks for
coronagraphic observations of exoplanets. A checkerboard mask design, a type of
binary pupil mask design, was adopted, and identical patterns of the same size
were used for all the masks in order that we could compare the differences
resulting from the different manufacturing methods. The masks on substrates had
aluminum checkerboard patterns with thicknesses of 0.1/0.2/0.4/0.8/1.6$\mu$m
constructed on substrates of BK7 glass, silicon, and germanium using
photolithography and chemical processes. Free-standing masks made of copper and
nickel with thicknesses of 2/5/10/20$\mu$m were also realized using
photolithography and chemical processes, which included careful release from
the substrate used as an intermediate step in the manufacture. Coronagraphic
experiments using a visible laser were carried out for all the masks on BK7
glass substrate and the free-standing masks. The average contrasts were
8.4$\times10^{-8}$, 1.2$\times10^{-7}$, and 1.2$\times10^{-7}$ for the masks on
BK7 substrates, the free-standing copper masks, and the free-standing nickel
masks, respectively. No significant correlation was concluded between the
contrast and the mask properties. The high contrast masks have the potential to
cover the needs of coronagraphs for both ground-based and space-borne
telescopes over a wide wavelength range. Especially, their application to the
infrared space telescope, SPICA, is appropriate.
[5]
oai:arXiv.org:1112.6301 [pdf] - 461637
Development of binary shaped pupil mask coronagraph for the observation
of exoplanets
Submitted: 2011-12-29, last modified: 2012-01-10
Direct observation of extra-solar planets (exoplanets) is essential to
understand how planetary systems were born, how they evolve, and ultimately, to
identify biological signatures on these planets. However, the enormous contrast
in flux between the central star and associated planets is the primary
difficulty in the direct observation. This has required stellar coronagraphs
which can improve the contrast between the star and the planet to be developed.
Of the various kinds of coronagraphs, we focused on a binary-shaped pupil mask
coronagraph. The reasons for using this coronagraph are robust against pointing
errors, essentially achromatic and relatively simple. We conducted a number of
coronagraph experiments using a vacuum chamber and a checker-board mask, a kind
of binary-shaped pupil mask, without active wavefront control. We demonstrated
PSF subtraction is potentially beneficial for improving contrast of a
binary-shaped pupil mask coronagraph, this coronagraph produces a significant
improvement in contrast with multi-color/broadband light sources, and the new
free-standing mask for practical use provides superior performance of improving
contrast. We performed the tasks necessary to make the coronagraph fit for
practical use. In conclusion, we carried out verification test for more real
coronagraphic observations.
[6]
oai:arXiv.org:1108.3157 [pdf] - 398626
The SPICA coronagraphic instrument (SCI) for the study of exoplanets
Enya, K.;
Kotani, T.;
Haze, K.;
Aono, K.;
Nakagawa, T.;
Matsuhara, H.;
Kataza, H.;
Wada, T.;
Kawada, M.;
Fujiwara, K.;
Mita, M.;
Takeuchi, S.;
Komatsu, K.;
Sakai, S.;
Uchida, H.;
Mitani, S.;
Yamawaki, T.;
Miyata, T.;
Sako, S.;
Nakamura, T.;
Asano, K.;
Yamashita, T.;
Narita, N.;
Matsuo, T.;
Tamura, M.;
Nishikawa, J.;
Kokubo, E.;
Hayano, Y.;
Oya, S.;
Fukagawa, M.;
Shibai, H.;
Baba, N.;
Murakami, N.;
Itoh, Y.;
Honda, M.;
Okamoto, B.;
Ida, S.;
Takami, M.;
Abe, L.;
Guyon, O.;
Bierden, P.;
Yamamuro, T.
Submitted: 2011-08-16
We present the SPICA Coronagraphic Instrument (SCI), which has been designed
for a concentrated study of extra-solar planets (exoplanets). SPICA mission
provides us with a unique opportunity to make high contrast observations
because of its large telescope aperture, the simple pupil shape, and the
capability for making infrared observations from space. The primary objectives
for the SCI are the direct coronagraphic detection and spectroscopy of Jovian
exoplanets in infrared, while the monitoring of transiting planets is another
important target. The specification and an overview of the design of the
instrument are shown. In the SCI, coronagraphic and non-coronagraphic modes are
applicable for both an imaging and a spectroscopy. The core wavelength range
and the goal contrast of the coronagraphic mode are 3.5--27$\mu$m, and
10$^{-6}$, respectively. Two complemental designs of binary shaped pupil mask
coronagraph are presented. The SCI has capability of simultaneous observations
of one target using two channels, a short channel with an InSb detector and a
long wavelength channel with a Si:As detector. We also give a report on the
current progress in the development of key technologies for the SCI.
[7]
oai:arXiv.org:1108.3194 [pdf] - 398632
High contrast experiment of an AO-free coronagraph with a checkerboard
pupil mask
Submitted: 2011-08-16
A high contrast coronagraph is expected to provide one of the promising ways
to directly observe extra-solar planets. We present the newest results of our
laboratory experiment investigating "rigid" coronagraph with a binary shaped
checkerboard pupil mask, which should offer a highly stable solution for
telescopes without adaptive optics (AO) for wavefront correction in space
missions. The primary aim of this work was to study the stability of the
coronagraph, and to demonstrate its performance without adaptive wavefront
correction. Estimation of both the raw contrast and the gain of the point
spread function (PSF) subtraction were needed. The limiting factor of the
contrast was also important. A binary shaped pupil mask of a checkerboard type
has been designed. The mask, consisting of an aluminum film on a glass
substrate, was manufactured using nano-fabrication techniques with electron
beam lithography. Careful evaluation of coronagraphic performance, including
PSF subtraction, was carried out in air using the developed mask. A contrast of
$6.7 \times 10^{-8}$ was achieved for the raw coronagraphic image by areal
averaging of all of the observed dark regions. Following PSF subtraction, the
contrast reached $6.8 \times 10^{-9}$. Speckles were a major limiting factor
throughout the dark regions of both the raw image and the PSF subtracted image.
A rigid coronagraph with PSF subtraction without AO is a useful method to
achieve high contrast observations. Applications of a rigid coronagraph to a
Space Infrared telescope for Cosmology and Astrophysics (SPICA) and other
platforms are discussed.
[8]
oai:arXiv.org:1105.2154 [pdf] - 1076546
Multi-Color Coronagraph Experiment in a Vacuum Testbed with a Binary
Shaped Pupil Mask
Submitted: 2011-05-11
We conducted a number of multi-band coronagraph experiments using a vacuum
chamber and a binary-shaped pupil mask which in principle should work at all
wavelengths, in the context of the research and development on a coronagraph to
observe extra-solar planets (exoplanets) directly. The aim of this work is to
demonstrate that subtraction of Point Spread Function (PSF) and multi-band
experiments using a binary-shaped pupil mask coronagraph would help improve the
contrast in the observation of exoplanets. A checkerboard mask, a kind of
binary-shaped pupil mask, was used. We improved the temperature stability by
installing the coronagraph optics in a vacuum chamber, controlling the
temperature of the optical bench, and covering the vacuum chamber with thermal
insulation layers. We evaluated how much the PSF subtraction contributes to the
high contrast observation by subtracting the images obtained through the
coronagraph. We also carried out multi- band experiments in order to
demonstrate a more realistic observation using Super luminescent Light Emitting
Diodes (SLEDs) with center wavelengths of 650nm, 750nm, 800nm and 850nm. A
contrast of 2.3x10-7 was obtained for the raw coronagraphic image and a
contrast of 1.3x10-9 was achieved after PSF subtraction with a He-Ne laser at
632.8nm wavelength. Thus, the contrast was improved by around two orders of
magnitude from the raw contrast by subtracting the PSF. We achieved contrasts
of 3.1x10-7, 1.1x10-6, 1.6x10-6 and 2.5x10-6 at the bands of 650nm, 750nm,
800nm and 850nm, respectively, in the multi-band experiments. The results show
that contrast within each of the wavelength bands was significantly improved
compared with non-coronagraphic optics. We demonstrated PSF subtraction is
potentially beneficial for improving contrast of the coronagraph, and this
coronagraph produces a significant improvement in contrast with multi-band
light sources.
[9]
oai:arXiv.org:0706.0253 [pdf] - 1000410
Detection of an H-alpha Emission Line on a Quasar, RX J1759.4+6638, at
z=4.3 with AKARI
Oyabu, Shinki;
Wada, Takehiko;
Ohyama, Youichi;
Matsuhara, Hideo;
Takagi, Toshinobu;
Nakagawa, Takao;
Onaka, Takashi;
Fujishiro, Naofumi;
Ishihara, Daisuke;
Ita, Yoshifusa;
Kataza, Hirokazu;
Kim, Woojung;
Matsumoto, Toshio;
Murakami, Hiroshi;
Sakon, Itsuki;
Tanabe, Toshihiko;
Uemizu, Kazunori;
Ueno, Munetaka;
Usui, Fumihiko;
Watarai, Hidenori;
Haze, Kanae
Submitted: 2007-06-02
We report the detection of an H-alpha emission line in the low resolution
spectrum of a quasar, RX J1759.4+6638, at a redshift of 4.3 with the InfraRed
Camera (IRC) onboard the AKARI. This is the first spectroscopic detection of an
H-alpha emission line in a quasar beyond z=4. The overall spectral energy
distribution (SED) of RX J1759.4+6638 in the near- and mid-infrared wavelengths
agrees with a median SED of the nearby quasars and the flux ratio of
F(Ly-alpha)/F(H-alpha) is consistent with those of previous reports for
lower-redshift quasars.