Normalized to: Du, Q.
[1]
oai:arXiv.org:1802.03541 [pdf] - 1634379
Harmonics of Solar Radio Spikes at Metric Wavelengths
Submitted: 2018-02-10
This paper presents the latest observations from the newly-built solar radio
spectrograph at the \emph{Chashan Solar Observatory}. On July 18 2016, the
spectrograph records a solar spike burst event, which has several episodes
showing harmonic structures, with the second, third, and fourth harmonics. The
lower harmonic radio spike emissions are observed later than the higher
harmonic bands, and the temporal delay of the second (third) harmonic relative
to the fourth harmonic is about 30\ --\ 40 (10) ms. Based on the electron
cyclotron maser emission mechanism, we analyze possible causes of the temporal
delay and further infer relevant coronal parameters, such as the magnetic field
strength and the electron density at the radio source.
[2]
oai:arXiv.org:1706.07915 [pdf] - 1585109
A Solar Radio Dynamic Spectrograph with Flexible Temporal-spectral
Resolution
Du, Qing-Fu;
Chen, Lei;
Zhao, Yue-Chang;
Li, Xin;
Zhou, Yan;
Zhang, Jun-Rui;
Yan, Fa-Bao;
Feng, Shi-Wei;
Li, Chuan-Yang;
Chen, Yao
Submitted: 2017-06-24
The observation and research of the solar radio emission have unique
scientific values in solar and space physics and related space weather
forecasting applications, since the observed spectral structures may carry
important information about energetic electrons and underlying physical
mechanisms. In this study, we present the design of a novel dynamic
spectrograph that is installed at the Chashan solar radio station operated by
Laboratory for Radio Technologies, Institute of Space Sciences at Shandong
University. The spectrograph is characterized by the real-time storage of
digitized radio intensity data in the time domain and its capability to perform
off-line spectral analysis of the radio spectra. The analog signals received
via antennas and amplified with a low-noise amplifier are converted into
digital data at a speed reaching up to 32 k data points per millisecond. The
digital data are then saved into a high-speed electronic disk for further
off-line spectral analysis. Using different word length (1 k - 32 k) and time
cadence (5 ms - 10 s) for the off-line fast Fourier transform analysis, we can
obtain the dynamic spectrum of a radio burst with different (user-defined)
temporal (5 ms - 10 s) and spectral (3 kHz ~ 320 kHz) resolution. This brings a
great flexibility and convenience to data analysis of solar radio bursts,
especially when some specific fine spectral structures are under study.
[3]
oai:arXiv.org:1403.5421 [pdf] - 862588
Limits on light WIMPs with a germanium detector at 177 eVee threshold at
the China Jinping Underground Laboratory
Liu, S. K.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Wong, H. T.;
Li, Y. J.;
Lin, S. T.;
Chang, J. P.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Q.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Lü, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wu, S. Y.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xiao, R. Q.;
Xing, H. Y.;
Xu, F. Z.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, C. W.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhao, W.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2014-03-21, last modified: 2014-08-01
The China Dark Matter Experiment reports results on light WIMP dark matter
searches at the China Jinping Underground Laboratory with a germanium detector
array with a total mass of 20 g. The physics threshold achieved is 177 eVee
("ee" represents electron equivalent energy) at 50% signal efficiency. With
0.784 kg-days of data, exclusion region on spin-independent coupling with the
nucleon is derived, improving over our earlier bounds at WIMP mass less than
4.6 GeV.
[4]
oai:arXiv.org:1306.4135 [pdf] - 719413
First results on low-mass WIMP from the CDEX-1 experiment at the China
Jinping underground Laboratory
Zhao, W.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Li, Y. J.;
Lin, S. T.;
Bai, Y.;
Bi, Y.;
Chang, J. P.;
Chen, N.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, C.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Hu, X. H.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Liu, S. K.;
Lv, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wong, H. T.;
Wu, S. Y.;
Wu, W.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xing, H. Y.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhong, S. N.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2013-06-18, last modified: 2013-08-08
The China Dark matter Experiment collaboration reports the first experimental
limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type
point-contact germanium detector at the China Jinping underground Laboratory
where the rock overburden is more than 2400 m. The energy threshold achieved
was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N=
1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent
cross-section at WIMP mass of 7 GeV before differentiating bulk signals from
the surface backgrounds.
[5]
oai:arXiv.org:1305.0401 [pdf] - 1166364
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark
Matter Searches
Kang, Ke-Jun;
Yue, Qian;
Wu, Yu-Cheng;
Cheng, Jian-Ping;
Li, Yuan-Jing;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Chuang, You-Chun;
Dend, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Huang, Teng-Rui;
Jiang, Hao;
Li, Hau-Bin;
Li, Jian-Min;
Li, Jin;
Li, Jun;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liao, Heng-Ye;
Lin, Fong-Kay;
Lin, Shin-Ted;
Liu, Shu-Kui;
Lv, Lan-Chun;
Ma, Hao;
Mao, Shao-Ji;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Singh, Lakhwinder;
Singh, Manoj Kumar;
Soma, Arun Kumar;
Su, Jian;
Tang, Chang-Jian;
Tseng, Chao-Hsiung;
Wang, Ji-Min;
Wang, Li;
Wang, Qing;
Wong, Tsz-King Henry;
Wu, Shi-Yong;
Wu, Wei;
Wu, Yu-Cheng;
Xing, Hao-Yang;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yang, Song-Wei;
Yi, Nan;
Yu, Chun-Xu;
Yu, Hao;
Yu, Xun-Zhen;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Yun-Hua;
Zhao, Ming-Gang;
Zhao, Wei;
Zhong, Su-Ning;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-05-02
The CDEX Collaboration has been established for direct detection of light
dark matter particles, using ultra-low energy threshold p-type point-contact
germanium detectors, in China JinPing underground Laboratory (CJPL). The first
1 kg point-contact germanium detector with a sub-keV energy threshold has been
tested in a passive shielding system located in CJPL. The outputs from both the
point-contact p+ electrode and the outside n+ electrode make it possible to
scan the lower energy range of less than 1 keV and at the same time to detect
the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode
may also provide a more powerful method for signal discrimination for dark
matter experiment. Some key parameters, including energy resolution, dead time,
decay times of internal X-rays, and system stability, have been tested and
measured. The results show that the 1 kg point-contact germanium detector,
together with its shielding system and electronics, can run smoothly with good
performances. This detector system will be deployed for dark matter search
experiments.
[6]
oai:arXiv.org:1303.0601 [pdf] - 813786
Introduction of the CDEX experiment
Kang, Ke-Jun;
Cheng, Jian-Ping;
Li, Jin;
Li, Yuan-Jing;
Yue, Qian;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Deng, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Hong-Jian;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Jiang, Hao;
Li, Jian-Min;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liu, Shu-Kui;
Liu, Ya-Bin;
Lu, Lan-Chun;
Ma, Hao;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Su, Jian;
Tang, Chang-Jian;
Tang, Zhen-Yu;
Wang, Ji-Min;
Wang, Qing;
Wang, Xu-Feng;
Wu, Shi-Yong;
Wu, Yu-Cheng;
Xianyu, Zhong-Zhi;
Xing, Hao-Yang;
Xu, Xun-Jie;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yi, Nan;
Yu, Hao;
Yu, Chun-Xu;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Guang-Hua;
Zhao, Ming-Gang;
Zhong, Su-Ning;
Zhou, Jin;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-03-03
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark
matter in our universe. Up to now any direct interaction of WIMP with nuclei
has not been observed yet. The exclusion limits of the spin-independent cross
section of WIMP-nucleon which have been experimentally obtained is about
10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China
Jin-Ping underground laboratory CJPL is the deepest underground lab in the
world and provides a very promising environment for direct observation of dark
matter. The China Dark Matter Experiment (CDEX) experiment is going to directly
detect the WIMP flux with high sensitivity in the low mass region. Both CJPL
and CDEX have achieved a remarkable progress in recent two years. The CDEX
employs a point-contact germanium semi-conductor detector PCGe whose detection
threshold is less than 300 eV. We report the measurement results of Muon flux,
monitoring of radioactivity and Radon concentration carried out in CJPL, as
well describe the structure and performance of the 1 kg PCGe detector CDEX-1
and 10kg detector array CDEX-10 including the detectors, electronics, shielding
and cooling systems. Finally we discuss the physics goals of the CDEX-1,
CDEX-10 and the future CDEX-1T detectors.