Normalized to: Cong, Y.
[1]
oai:arXiv.org:2006.05605 [pdf] - 2112121
The Tianlai Cylinder Pathfinder Array: System Functions and Basic
Performance Analysis
Li, Jixia;
Zuo, Shifan;
Wu, Fengquan;
Wang, Yougang;
Zhang, Juyong;
Sun, Shijie;
Xu, Yidong;
Yu, Zijie;
Ansari, Reza;
Li, Yichao;
Stebbins, Albert;
Timbie, Peter;
Cong, Yanping;
Geng, Jingchao;
Hao, Jie;
Huang, Qizhi;
Li, Jianbin;
Li, Rui;
Liu, Donghao;
Liu, Yingfeng;
Liu, Tao;
Marriner, John P.;
Niu, Chenhui;
Pen, Ue-Li;
Peterson, Jeffery B.;
Shi, Huli;
Shu, Lin;
Song, Yafang;
Tian, Haijun;
Wang, Guisong;
Wang, Qunxiong;
Wang, Rongli;
Wang, Weixia;
Yu, Kaifeng;
Zhang, Jiao;
Zhu, Boqin;
Zhu, Jialu;
Chen, Xuelei
Submitted: 2020-06-09
The Tianlai Cylinder Pathfinder is a radio interferometer array designed to
test techniques for 21 cm intensity mapping in the post-reionization Universe,
with the ultimate aim of mapping the large scale structure and measuring
cosmological parameters such as the dark energy equation of state. Each of its
three parallel cylinder reflectors is oriented in the north-south direction,
and the array has a large field of view. As the Earth rotates, the northern sky
is observed by drift scanning. The array is located in Hongliuxia, a
radio-quiet site in Xinjiang, and saw its first light in September 2016. In
this first data analysis paper for the Tianlai cylinder array, we discuss the
sub-system qualification tests, and present basic system performance obtained
from preliminary analysis of the commissioning observations during 2016-2018.
We show typical interferometric visibility data, from which we derive the
actual beam profile in the east-west direction and the frequency band-pass
response. We describe also the calibration process to determine the complex
gains for the array elements, either using bright astronomical point sources,
or an artificial on site calibrator source, and discuss the instrument response
stability, crucial for transit interferometry. Based on this analysis, we find
a system temperature of about 90 K, and we also estimate the sensitivity of the
array.
[2]
oai:arXiv.org:1806.04698 [pdf] - 1706586
Progress in the Construction and Testing of the Tianlai Radio
Interferometers
Das, Santanu;
Anderson, Christopher J.;
Ansari, Reza;
Campagne, Jean-Eric;
Charlet, Daniel;
Chen, Xuelei;
Chen, Zhiping;
Cianciara, Aleksander J.;
Colom, Pierre;
Cong, Yanping;
Gayley, Kevin G.;
Geng, Jingchao;
Hao, Jie;
Huang, Qizhi;
Keith, Celeste S.;
Li, Chao;
Li, Jixia;
Li, Yichao;
Liu, Chao;
Liu, Tao;
Magneville, Christophe;
Marriner, John P.;
Martin, Jean-Michel;
Moniez, Marc;
Oxholm, Trevor M.;
Pen, Ue-Li;
Perdereau, Olivier;
Peterson, Jeffrey B.;
Shi, Huli;
Shu, Lin;
Stebbins, Albert;
Sun, Shijie;
Timbie, Peter T.;
Torchinsky, Steve;
Tucker, Gregory S.;
Wang, Guisong;
Wang, Rongli;
Wang, Xin;
Wang, Yougang;
Wu, Fengquan;
Xu, Yidong;
Yu, Kaifeng;
Zhang, Jiao;
Zhang, Juyong;
Zhang, Le;
Zhu, Jialu;
Zuo, Shifan
Submitted: 2018-06-12, last modified: 2018-06-26
The Tianlai Pathfinder is designed to demonstrate the feasibility of using a
wide field of view radio interferometers to map the density of neutral hydrogen
in the Universe after the Epoch of Reionizaton. This approach, called 21~cm
intensity-mapping, promises an inexpensive means for surveying the large-scale
structure of the cosmos. The Tianlai Pathfinder presently consists of an array
of three, 15~m $\times$ 40~m cylinder telescopes and an array of sixteen, 6~m
diameter dish antennas located in a radio-quiet part of western China. The two
types of arrays were chosen to determine the advantages and disadvantages of
each approach. The primary goal of the Pathfinder is to make 3D maps by
surveying neutral hydrogen over large areas of the sky %$20,000 {\rm deg}^2$ in
two different redshift ranges: first at $1.03 > z > 0.78$ ($700 - 800$~MHz) and
later at $0.21 > z > 0.12$ ($1170 - 1270$~MHz). The most significant challenge
to $21$~cm intensity-mapping is the removal of strong foreground radiation that
dwarfs the cosmological signal. It requires exquisite knowledge of the
instrumental response, i.e. calibration. In this paper, we provide an overview
of the status of the Pathfinder and discuss the details of some of the analysis
that we have carried out to measure the beam function of both arrays. We
compare electromagnetic simulations of the arrays to measurements, discuss
measurements of the gain and phase stability of the instrument, and provide a
brief overview of the data processing pipeline.