Normalized to: Chuang, Y.
[1]
oai:arXiv.org:1410.5325 [pdf] - 1222664
Ethyl cyanide on Titan: Spectroscopic detection and mapping using ALMA
Cordiner, M. A.;
Palmer, M. Y.;
Nixon, C. A.;
Irwin, P. G. J.;
Teanby, N. A.;
Charnley, S. B.;
Mumma, M. J.;
Kisiel, Z.;
Serigano, J.;
Kuan, Y. -J.;
Chuang, Y. -L.;
Wang, K. -S.
Submitted: 2014-10-20, last modified: 2015-03-10
We report the first spectroscopic detection of ethyl cyanide (C$_2$H$_5$CN)
in Titan's atmosphere, obtained using spectrally and spatially resolved
observations of multiple emission lines with the Atacama Large
Millimeter/submillimeter array (ALMA). The presence of C$_2$H$_5$CN in Titan's
ionosphere was previously inferred from Cassini ion mass spectrometry
measurements of C$_2$H$_5$CNH$^+$. Here we report the detection of 27
rotational lines from C$_2$H$_5$CN (in 19 separate emission features detected
at $>3\sigma$ confidence), in the frequency range 222-241 GHz. Simultaneous
detections of multiple emission lines from HC$_3$N, CH$_3$CN and CH$_3$CCH were
also obtained. In contrast to HC$_3$N, CH$_3$CN and CH$_3$CCH, which peak in
Titan's northern (spring) hemisphere, the emission from C$_2$H$_5$CN is found
to be concentrated in the southern (autumn) hemisphere, suggesting a distinctly
different chemistry for this species, consistent with a relatively short
chemical lifetime for C$_2$H$_5$CN. Radiative transfer models show that most of
the C$_2$H$_5$CN is concentrated at altitudes 300-600 km, suggesting production
predominantly in the mesosphere and above. Vertical column densities are found
to be in the range (2-5)$\times10^{14}$ cm$^{-2}$.
[2]
oai:arXiv.org:1408.2458 [pdf] - 1216228
Mapping the release of volatiles in the inner comae of comets C/2012 F6
(Lemmon) and C/2012 S1 (ISON) using the Atacama Large
Millimeter/Submillimeter Array
Cordiner, M. A.;
Remijan, A. J.;
Boissier, J.;
Milam, S. N.;
Mumma, M. J.;
Charnley, S. B.;
Paganini, L.;
Villanueva, G.;
Bockelee-Morvan, D.;
Kuan, Y. -J.;
Chuang, Y. -L.;
Lis, D. C.;
Biver, N.;
Crovisier, J.;
Minniti, D.;
Coulson, I. M.
Submitted: 2014-08-11
Results are presented from the first cometary observations using the Atacama
Large Millimeter/Submillimeter Array (ALMA), including measurements of the
spatially-resolved distributions of HCN, HNC, H$_2$CO and dust within the comae
of two comets: C/2012 F6 (Lemmon) and C/2012 S1 (ISON), observed at
heliocentric distances of 1.5 AU and 0.54 AU, respectively. These observations
(with angular resolution $\approx0.5''$), reveal an unprecedented level of
detail in the distributions of these fundamental cometary molecules, and
demonstrate the power of ALMA for quantitative measurements of the
distributions of molecules and dust in the inner comae of typical bright
comets. In both comets, HCN is found to originate from (or within a few hundred
km of) the nucleus, with a spatial distribution largely consistent with
spherically-symmetric, uniform outflow. By contrast, the HNC distributions are
clumpy and asymmetrical, with peaks at cometocentric radii $\sim$500-1000~km,
consistent with release of HNC in collimated outflow(s). Compared to HCN, the
H$_2$CO distribution in comet Lemmon is very extended. The interferometric
visibility amplitudes are consistent with coma production of H$_2$CO and HNC
from unidentified precursor material(s) in both comets. Adopting a Haser model,
the H$_2$CO parent scale-length is found to be a few thousand km in Lemmon and
only a few hundred km in ISON, consistent with destruction of the precursor by
photolysis or thermal degradation at a rate which scales in proportion to the
Solar radiation flux.
[3]
oai:arXiv.org:1403.5421 [pdf] - 862588
Limits on light WIMPs with a germanium detector at 177 eVee threshold at
the China Jinping Underground Laboratory
Liu, S. K.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Wong, H. T.;
Li, Y. J.;
Lin, S. T.;
Chang, J. P.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Q.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Lü, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wu, S. Y.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xiao, R. Q.;
Xing, H. Y.;
Xu, F. Z.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, C. W.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhao, W.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2014-03-21, last modified: 2014-08-01
The China Dark Matter Experiment reports results on light WIMP dark matter
searches at the China Jinping Underground Laboratory with a germanium detector
array with a total mass of 20 g. The physics threshold achieved is 177 eVee
("ee" represents electron equivalent energy) at 50% signal efficiency. With
0.784 kg-days of data, exclusion region on spin-independent coupling with the
nucleon is derived, improving over our earlier bounds at WIMP mass less than
4.6 GeV.
[4]
oai:arXiv.org:1407.2185 [pdf] - 1215496
Ground-based Multiwavelength Observations of Comet 103P/Hartley 2
Submitted: 2014-07-08
The Jupiter-family comet 103P/Hartley 2 (103P) was the target of the NASA
EPOXI mission. In support of this mission, we conducted observations from radio
to submillimeter wavelengths of comet 103P in the three weeks preceding the
spacecraft rendezvous on UT 2010 November 4.58. This time period included the
passage at perihelion and the closest approach of the comet to the Earth. Here
we report detections of HCN, H2CO, CS, and OH and upper limits for HNC and DCN
towards 103P, using the Arizona Radio Observatory Kitt Peak 12m telescope (ARO
12m) and submillimeter telescope (SMT), the James Clerk Maxwell Telescope
(JCMT) and the Greenbank Telescope (GBT). The water production rate, QH2O =
(0.67 - 1.07) x 10^28 s^-1, was determined from the GBT OH data. From the
average abundance ratios of HCN and H2CO relative to water (0.13 +/- 0.03 % and
0.14 +/- 0.03 %, respectively), we conclude that H2CO is depleted and HCN is
normal with respect to typically-observed cometary mixing ratios. However, the
abundance ratio of HCN with water shows a large diversity with time. Using the
JCMT data we measured an upper limit for the DCN/HCN ratio <0.01. Consecutive
observations of ortho- H2CO and para-H2CO on November 2 (from data obtained at
the JCMT), allowed us to derive an ortho : para ratio (OPR) ~ 2.12 +/- 0.59
(1sigma), corresponding to Tspin > 8 K (2sigma).
[5]
oai:arXiv.org:1306.4135 [pdf] - 719413
First results on low-mass WIMP from the CDEX-1 experiment at the China
Jinping underground Laboratory
Zhao, W.;
Yue, Q.;
Kang, K. J.;
Cheng, J. P.;
Li, Y. J.;
Lin, S. T.;
Bai, Y.;
Bi, Y.;
Chang, J. P.;
Chen, N.;
Chen, N.;
Chen, Q. H.;
Chen, Y. H.;
Chuang, Y. C.;
Deng, Z.;
Du, C.;
Du, Q.;
Gong, H.;
Hao, X. Q.;
He, H. J.;
He, Q. J.;
Hu, X. H.;
Huang, H. X.;
Huang, T. R.;
Jiang, H.;
Li, H. B.;
Li, J. M.;
Li, J.;
Li, J.;
Li, X.;
Li, X. Y.;
Li, Y. L.;
Liao, H. Y.;
Lin, F. K.;
Liu, S. K.;
Lv, L. C.;
Ma, H.;
Mao, S. J.;
Qin, J. Q.;
Ren, J.;
Ren, J.;
Ruan, X. C.;
Shen, M. B.;
Singh, L.;
Singh, M. K.;
Soma, A. K.;
Su, J.;
Tang, C. J.;
Tseng, C. H.;
Wang, J. M.;
Wang, L.;
Wang, Q.;
Wong, H. T.;
Wu, S. Y.;
Wu, W.;
Wu, Y. C.;
Wu, Y. C.;
Xianyu, Z. Z.;
Xing, H. Y.;
Xu, Y.;
Xu, X. J.;
Xue, T.;
Yang, L. T.;
Yang, S. W.;
Yi, N.;
Yu, C. X.;
Yu, H.;
Yu, X. Z.;
Zeng, X. H.;
Zeng, Z.;
Zhang, L.;
Zhang, Y. H.;
Zhao, M. G.;
Zhong, S. N.;
Zhou, Z. Y.;
Zhu, J. J.;
Zhu, W. B.;
Zhu, X. Z.;
Zhu, Z. H.
Submitted: 2013-06-18, last modified: 2013-08-08
The China Dark matter Experiment collaboration reports the first experimental
limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type
point-contact germanium detector at the China Jinping underground Laboratory
where the rock overburden is more than 2400 m. The energy threshold achieved
was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N=
1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent
cross-section at WIMP mass of 7 GeV before differentiating bulk signals from
the surface backgrounds.
[6]
oai:arXiv.org:1305.0401 [pdf] - 1166364
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark
Matter Searches
Kang, Ke-Jun;
Yue, Qian;
Wu, Yu-Cheng;
Cheng, Jian-Ping;
Li, Yuan-Jing;
Bai, Yang;
Bi, Yong;
Chang, Jian-Ping;
Chen, Nan;
Chen, Ning;
Chen, Qing-Hao;
Chen, Yun-Hua;
Chuang, You-Chun;
Dend, Zhi;
Du, Qiang;
Gong, Hui;
Hao, Xi-Qing;
He, Qing-Ju;
Hu, Xin-Hui;
Huang, Han-Xiong;
Huang, Teng-Rui;
Jiang, Hao;
Li, Hau-Bin;
Li, Jian-Min;
Li, Jin;
Li, Jun;
Li, Xia;
Li, Xin-Ying;
Li, Xue-Qian;
Li, Yu-Lan;
Liao, Heng-Ye;
Lin, Fong-Kay;
Lin, Shin-Ted;
Liu, Shu-Kui;
Lv, Lan-Chun;
Ma, Hao;
Mao, Shao-Ji;
Qin, Jian-Qiang;
Ren, Jie;
Ren, Jing;
Ruan, Xi-Chao;
Shen, Man-Bin;
Singh, Lakhwinder;
Singh, Manoj Kumar;
Soma, Arun Kumar;
Su, Jian;
Tang, Chang-Jian;
Tseng, Chao-Hsiung;
Wang, Ji-Min;
Wang, Li;
Wang, Qing;
Wong, Tsz-King Henry;
Wu, Shi-Yong;
Wu, Wei;
Wu, Yu-Cheng;
Xing, Hao-Yang;
Xu, Yin;
Xue, Tao;
Yang, Li-Tao;
Yang, Song-Wei;
Yi, Nan;
Yu, Chun-Xu;
Yu, Hao;
Yu, Xun-Zhen;
Zeng, Xiong-Hui;
Zeng, Zhi;
Zhang, Lan;
Zhang, Yun-Hua;
Zhao, Ming-Gang;
Zhao, Wei;
Zhong, Su-Ning;
Zhou, Zu-Ying;
Zhu, Jing-Jun;
Zhu, Wei-Bin;
Zhu, Xue-Zhou;
Zhu, Zhong-Hua
Submitted: 2013-05-02
The CDEX Collaboration has been established for direct detection of light
dark matter particles, using ultra-low energy threshold p-type point-contact
germanium detectors, in China JinPing underground Laboratory (CJPL). The first
1 kg point-contact germanium detector with a sub-keV energy threshold has been
tested in a passive shielding system located in CJPL. The outputs from both the
point-contact p+ electrode and the outside n+ electrode make it possible to
scan the lower energy range of less than 1 keV and at the same time to detect
the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode
may also provide a more powerful method for signal discrimination for dark
matter experiment. Some key parameters, including energy resolution, dead time,
decay times of internal X-rays, and system stability, have been tested and
measured. The results show that the 1 kg point-contact germanium detector,
together with its shielding system and electronics, can run smoothly with good
performances. This detector system will be deployed for dark matter search
experiments.