[1]  oai:arXiv.org:1912.05894  [pdf] - 2115146
A Mini-Imaging Air Cherenkov Telescope
Comments: submitted to JINST
Submitted: 2019-12-12
In this paper we describe the different software and hardware elements of a mini-telescope for the detection of cosmic rays and gamma-rays using the Cherenkov light emitted by their induced particle showers in the atmosphere. We estimate the physics reach of the standalone mini-telescope and present some results of the measurements done at the Sauverny Observatory of the University of Geneva and at the Saint-Luc Observatory, which demonstrate the ability of the telescope to observe cosmic rays with energy above about 100 TeV. Such a mini-telescope can constitute a cost-effective out-trigger array that can surround other gamma-ray telescopes or extended air showers detector arrays. Its development was born out of the desire to illustrate to students and amateurs the cosmic ray and gamma-ray detection from ground, as an example of what is done in experiments using larger telescopes. As a matter of fact, a mini-telescope can be used in outreach night events. While outreach is becoming more and more important in the scientific community to raise interest in the general public, the realisation of the mini-telescope is also a powerful way to train students on instrumentation such as photosensors, their associated electronics, acquisition software and data taking. In particular, this mini-telescope uses silicon photomultipliers (SiPM) and the dedicated ASIC, CITIROC.
[2]  oai:arXiv.org:1908.06860  [pdf] - 1945116
Calibration and operation of SiPM-based cameras for gamma-ray astronomy in presence of high night-sky light
Comments:
Submitted: 2019-08-19
The next generation of Cherenkov telescope cameras feature Silicon Photo Multipliers (SiPM), which can guarantee excellent performance and allow for observation also under moonlight, increasing duty-cycle and therefore the physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree optical FoV and a 1296-pixel SiPM camera, has been designed to meet the requirements of the next generation of ground-based gamma-ray observatories at the highest energies. The large-scale production of the telescopes for array deployment has required the development of a fully automated calibration strategy which relies on a dedicated hardware, the Camera Test Setup (CTS). For each camera pixel, the CTS is equipped with two LEDs, one operated in pulsed mode to reproduce signal and one in continuous mode to reproduce night-sky background. In this contribution we will present the camera calibration strategy, from the laboratory measurement to the on-site monitoring with emphasis on the results obtained with the first camera prototype. In addition, key performances such as charge resolution, time resolution and trigger efficiencies and their degradation with increasing night-sky background level will be presented.
[3]  oai:arXiv.org:1907.08061  [pdf] - 1918999
Monte Carlo study of a single SST-1M prototype for the Cherenkov Telescope Array
Comments: 8 pages, 13 figures, ICRC 2019 proceeding
Submitted: 2019-07-18
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope for the Cherenkov Telescope Array observatory and it has been extensively tested in Krakow since 2017. In this contribution we present validation of the Monte Carlo model of the prototype and expected performance in Krakow conditions. We focus on gamma/hadron separation and mono reconstruction of energy and gamma photon arrival direction using Machine learning methods.
[4]  oai:arXiv.org:1901.04351  [pdf] - 1818883
Penetrating particle ANalyzer (PAN)
Comments:
Submitted: 2019-01-14, last modified: 2019-01-21
PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather and space travel. PAN will fill an observation gap of galactic cosmic rays in the GeV region, and provide precise information of the spectrum, composition and emission time of energetic particle originated from the Sun. The precise measurement and monitoring of the energetic particles is also a unique contribution to space weather studies. PAN will map the flux and composition of penetrating particles, which cannot be shielded effectively, precisely and continuously, providing valuable input for the assessment of the related health risk, and for the development of an adequate mitigation strategy. PAN has the potential to become a standard on-board instrument for deep space human travel. PAN is based on the proven detection principle of a magnetic spectrometer, but with novel layout and detection concept. It will adopt advanced particle detection technologies and industrial processes optimized for deep space application. The device will require limited mass (~20 kg) and power (~20 W) budget. Dipole magnet sectors built from high field permanent magnet Halbach arrays, instrumented in a modular fashion with high resolution silicon strip detectors, allow to reach an energy resolution better than 10\% for nuclei from H to Fe at 1 GeV/n.
[5]  oai:arXiv.org:1901.04207  [pdf] - 1857202
Detailed polarization measurements of the prompt emission of five Gamma-Ray Bursts
Comments: 34 pages, 15 figures (16 pages and 3 figures without supplementary information). Accepted for publication in Nature Astronomy, http://dx.doi.org/10.1038/s41550-018-0664-0
Submitted: 2019-01-14
Gamma-ray bursts are the strongest explosions in the Universe since the Big Bang, believed to be produced either in forming black holes at the end of massive star evolution or merging of compact objects. Spectral and timing properties of gamma-ray bursts suggest that the observed bright gamma-rays are produced in the most relativistic jets in the Universe; however, the physical properties, especially the structure and magnetic topologies in the jets are still not well known, despite several decades of studies. It is widely believed that precise measurements of the polarization properties of gamma-ray bursts should provide crucial information on the highly relativistic jets. As a result there have been many reports of gamma-ray burst polarization measurements with diverse results, see, however many such measurements suffered from substantial uncertainties, mostly systematic. After the first successful measurements by the GAP and COSI instruments, here we report a statistically meaningful sample of precise polarization measurements, obtained with the dedicated gamma-ray burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results suggest that the gamma-ray emission is at most polarized at a level lower than some popular models have predicted; although our results also show intrapulse evolution of the polarization angle. This indicates that the low polarization degrees could be due to an evolving polarization angle during a gamma-ray burst.
[6]  oai:arXiv.org:1812.04020  [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan; Santangelo, Andrea; Feroci, Marco; Xu, YuPeng; Lu, FangJun; Chen, Yong; Feng, Hua; Zhang, Shu; Brandt, Søren; Hernanz, Margarita; Baldini, Luca; Bozzo, Enrico; Campana, Riccardo; De Rosa, Alessandra; Dong, YongWei; Evangelista, Yuri; Karas, Vladimir; Meidinger, Norbert; Meuris, Aline; Nandra, Kirpal; Pan, Teng; Pareschi, Giovanni; Orleanski, Piotr; Huang, QiuShi; Schanne, Stephane; Sironi, Giorgia; Spiga, Daniele; Svoboda, Jiri; Tagliaferri, Gianpiero; Tenzer, Christoph; Vacchi, Andrea; Zane, Silvia; Walton, Dave; Wang, ZhanShan; Winter, Berend; Wu, Xin; Zand, Jean J. M. in 't; Ahangarianabhari, Mahdi; Ambrosi, Giovanni; Ambrosino, Filippo; Barbera, Marco; Basso, Stefano; Bayer, Jörg; Bellazzini, Ronaldo; Bellutti, Pierluigi; Bertucci, Bruna; Bertuccio, Giuseppe; Borghi, Giacomo; Cao, XueLei; Cadoux, Franck; Campana, Riccardo; Ceraudo, Francesco; Chen, TianXiang; Chen, YuPeng; Chevenez, Jerome; Civitani, Marta; Cui, Wei; Cui, WeiWei; Dauser, Thomas; Del Monte, Ettore; Di Cosimo, Sergio; Diebold, Sebastian; Doroshenko, Victor; Dovciak, Michal; Du, YuanYuan; Ducci, Lorenzo; Fan, QingMei; Favre, Yannick; Fuschino, Fabio; Gálvez, José Luis; Gao, Min; Ge, MingYu; Gevin, Olivier; Grassi, Marco; Gu, QuanYing; Gu, YuDong; Han, DaWei; Hong, Bin; Hu, Wei; Ji, Long; Jia, ShuMei; Jiang, WeiChun; Kennedy, Thomas; Kreykenbohm, Ingo; Kuvvetli, Irfan; Labanti, Claudio; Latronico, Luca; Li, Gang; Li, MaoShun; Li, Xian; Li, Wei; Li, ZhengWei; Limousin, Olivier; Liu, HongWei; Liu, XiaoJing; Lu, Bo; Luo, Tao; Macera, Daniele; Malcovati, Piero; Martindale, Adrian; Michalska, Malgorzata; Meng, Bin; Minuti, Massimo; Morbidini, Alfredo; Muleri, Fabio; Paltani, Stephane; Perinati, Emanuele; Picciotto, Antonino; Piemonte, Claudio; Qu, JinLu; Rachevski, Alexandre; Rashevskaya, Irina; Rodriguez, Jerome; Schanz, Thomas; Shen, ZhengXiang; Sheng, LiZhi; Song, JiangBo; Song, LiMing; Sgro, Carmelo; Sun, Liang; Tan, Ying; Uttley, Phil; Wang, Juan; Wang, LangPing; Wang, YuSa; Watts, Anna L.; Wen, XiangYang; Wilms, Jörn; Xiong, ShaoLin; Yang, JiaWei; Yang, Sheng; Yang, YanJi; Yu, Nian; Zhang, WenDa; Zampa, Gianluigi; Zampa, Nicola; Zdziarski, Andrzej A.; Zhang, AiMei; Zhang, ChengMo; Zhang, Fan; Zhang, Long; Zhang, Tong; Zhang, Yi; Zhang, XiaoLi; Zhang, ZiLiang; Zhao, BaoSheng; Zheng, ShiJie; Zhou, YuPeng; Zorzi, Nicola; Zwart, J. Frans
Comments: Accepted for publication on Sci. China Phys. Mech. Astron. (2019)
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
[7]  oai:arXiv.org:1807.11269  [pdf] - 1724303
The Large Area Detector onboard the eXTP mission
Comments: Paper presented at SPIE Space Telescopes and Instrumentation 2018
Submitted: 2018-07-30
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.
[8]  oai:arXiv.org:1806.10355  [pdf] - 1706640
In-flight performance of the DAMPE silicon tracker
Comments:
Submitted: 2018-06-27
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon conversions into electron-positron pairs. The STK is a crucial component of DAMPE, allowing to determine the direction of incoming photons, to reconstruct tracks of cosmic rays and to estimate their absolute charge (Z). We present the in-flight performance of the STK based on two years of in-flight DAMPE data, which includes the noise behavior, signal response, thermal and mechanical stability, alignment and position resolution.
[9]  oai:arXiv.org:1710.08918  [pdf] - 1724839
In-flight energy calibration of the space-borne Compton polarimeter POLAR
Comments: Submitted to Astroparticle Physics Journal on Dec. 15, 2017
Submitted: 2017-10-24, last modified: 2018-06-05
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.
[10]  oai:arXiv.org:1805.07605  [pdf] - 1690419
In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements
Comments: 43 pages, 30 figures, 1 table; Preprint accepted by NIMA
Submitted: 2018-05-19, last modified: 2018-05-28
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the Chinese space laboratory TG-2 on 15th September, 2016. In order to reliably reconstruct the polarization information a highly detailed understanding of the instrument is required for both data analysis and Monte Carlo studies. For this purpose a full study of the in-orbit performance was performed in order to obtain the instrument calibration parameters such as noise, pedestal, gain nonlinearity of the electronics, threshold, crosstalk and gain, as well as the effect of temperature on the above parameters. Furthermore the relationship between gain and high voltage of the multi-anode photomultiplier tube has been studied and the errors on all measurement values are presented. Finally the typical systematic error on polarization measurements of Gamma-Ray Bursts due to the measurement error of the calibration parameters are estimated using Monte Carlo simulations.
[11]  oai:arXiv.org:1709.07191  [pdf] - 1588657
Design and construction of the POLAR detector
Comments:
Submitted: 2017-09-21, last modified: 2017-09-28
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The construction of the instrument components is described in this article. Details are provided on problems encountered during the construction phase and their solutions. Initial performance of the instrument in orbit is as expected from ground tests and Monte Carlo simulation.
[12]  oai:arXiv.org:1709.04244  [pdf] - 1620692
Control Software for the SST-1M Small-Size Telescope prototype for the Cherenkov Telescope Array
Comments: In Proceedings of the 35th International Cosmic Ray Conference (ICRC2017), Busan, Korea. All CTA contributions at arXiv:1709.03483
Submitted: 2017-09-13, last modified: 2017-09-14
The SST-1M is a 4-m Davies--Cotton atmospheric Cherenkov telescope optimized to provide gamma-ray sensitivity above a few TeV. The SST-1M is proposed as part of the Small-Size Telescope array for the Cherenkov Telescope Array (CTA), the first prototype has already been deployed. The SST-1M control software of all subsystems (active mirror control, drive system, safety system, photo-detection plane, DigiCam, CCD cameras) and the whole telescope itself (master controller) uses the standard software design proposed for all CTA telescopes based on the ALMA Common Software (ACS) developed to control the Atacama Large Millimeter Array (ALMA). Each subsystem is represented by a separate ACS component, which handles the communication to and the operation of the subsystem. Interfacing with the actual hardware is performed via the OPC UA communication protocol, supported either natively by dedicated industrial standard servers (PLCs) or separate service applications developed to wrap lower level protocols (e.g. CAN bus, camera slow control) into OPC UA. Early operations of the telescope without the camera were already carried out. The camera is fully assembled and is capable to perform data acquisition using artificial light source.
[13]  oai:arXiv.org:1709.03914  [pdf] - 1620686
Performance of a small size telescope (SST-1M) camera for gamma-ray astronomy with the Cherenkov Telescope Array
Comments: All CTA contributions at arXiv:1709.03483
Submitted: 2017-09-12
The foreseen implementations of the Small Size Telescopes (SST) in CTA will provide unique insights into the highest energy gamma rays offering fundamental means to discover and under- stand the sources populating the Galaxy and our local neighborhood. Aiming at such a goal, the SST-1M is one of the three different implementations that are being prototyped and tested for CTA. SST-1M is a Davies-Cotton single mirror telescope equipped with a unique camera technology based on SiPMs with demonstrated advantages over classical photomultipliers in terms of duty-cycle. In this contribution, we describe the telescope components, the camera, and the trigger and readout system. The results of the commissioning of the camera using a dedicated test setup are then presented. The performances of the camera first prototype in terms of expected trigger rates and trigger efficiencies for different night-sky background conditions are presented, and the camera response is compared to end-to-end simulations.
[14]  oai:arXiv.org:1709.03920  [pdf] - 1620687
Development of a strategy for calibrating the novel SiPM camera of the SST-1M telescope proposed for the Cherenkov Telescope Array
Comments: All CTA contributions at arXiv:1709.03483
Submitted: 2017-09-12
CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with 9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the requirements of the next generation ground based gamma-ray observatory CTA in the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of gamma-ray telescopes can achieve good performance even during high night sky background conditions. Defining a fully automated calibration strategy of SiPM cameras is of great importance for large scale production validation and online calibration. The SST-1M sub-consortium developed a software compatible with CTA pipeline software (CTApipe). The calibration of the SST-1M camera is based on the Camera Test Setup (CTS), a set of LED boards mounted in front of the camera. The CTS LEDs are operated in pulsed or continuous mode to emulate signal and night sky background respectively. Continuous and pulsed light data analysis allows us to extract single pixel calibration parameters to be used during CTA operation.
[15]  oai:arXiv.org:1708.00664  [pdf] - 1586674
Instrument Performance and Simulation Verification of the POLAR Detector
Comments: Preprint Accepted for Publication in Nuclear Instruments and Methods in Physics Research A
Submitted: 2017-08-02
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
[16]  oai:arXiv.org:1704.06173  [pdf] - 1567780
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Comments: The paper was withdrawn by authors because the work has not yet finshed
Submitted: 2017-04-20, last modified: 2017-04-24
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
[17]  oai:arXiv.org:1703.04210  [pdf] - 1547762
Gain factor and parameter settings optimization of the new gamma-ray burst polarimeter POLAR
Comments: There still some disagreement about one of the conclusions presented in the paper among all the authors
Submitted: 2017-03-12, last modified: 2017-03-14
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In this article we present results on gain optimization togeter with verification data obtained in the course of broad laboratory and environmental tests. In particular we focus on exposures to the $^{137}$Cs radioactive source and determination of the gain dependence on the high voltage for all 1600 detection channels of the polarimeter. Performance of the instrument is described in detail with respect to the dynamic range, energy resolution and temperature dependence. Gain optimization algorithms and response non-uniformity studies are also broadly discussed. Results presented below constitute important parts for development of the POLAR calibration and operation database.
[18]  oai:arXiv.org:1612.04098  [pdf] - 1533322
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB Polarimeter
Comments:
Submitted: 2016-12-13
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measurements of the polarization of the emission from gamma-ray burst in the 50-500 keV energy range. This new polarimeter is expected to detect approximately 50 gamma-ray bursts per year while performing high precision polarization measurements on approximately 10 bursts per year. The instrument was launched into lower earth orbit as part of the second Chinese space lab, the Tiangong-2, on September 15th 2016 and has been taking data successfully since being switched on one week after. The instrument uses a segmented scintillator array consisting of 1600 plastic scintillator bars, read out by 25 flat-panel multi-anode photomultipliers, to measure the Compton scattering angles of incoming photons. The small segmentation and relatively large uniform effective area allow the instrument to measure the polarization of a large number of transient events, such as gamma-ray bursts, with an unprecedented precision during its two year life-time. The final flight model underwent detailed calibration prior to launch as well as intensive space qualification tests, a summary of which will be presented in this paper. The instrument design will be discussed first followed by an overview of the on-ground tests, finally the in-orbit behavior as measured during the first weeks of the mission will be presented.
[19]  oai:arXiv.org:1610.05151  [pdf] - 1497663
Contributions of the Cherenkov Telescope Array (CTA) to the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016)
Consortium, The CTA; :; Abchiche, A.; Abeysekara, U.; Abril, Ó.; Acero, F.; Acharya, B. S.; Adams, C.; Agnetta, G.; Aharonian, F.; Akhperjanian, A.; Albert, A.; Alcubierre, M.; Alfaro, J.; Alfaro, R.; Allafort, A. J.; Aloisio, R.; Amans, J. -P.; Amato, E.; Ambrogi, L.; Ambrosi, G.; Ambrosio, M.; Anderson, J.; Anduze, M.; Angüner, E. O.; Antolini, E.; Antonelli, L. A.; Antonucci, M.; Antonuccio, V.; Antoranz, P.; Aramo, C.; Aravantinos, A.; Araya, M.; Arcaro, C.; Arezki, B.; Argan, A.; Armstrong, T.; Arqueros, F.; Arrabito, L.; Arrieta, M.; Asano, K.; Ashley, M.; Aubert, P.; Singh, C. B.; Babic, A.; Backes, M.; Bais, A.; Bajtlik, S.; Balazs, C.; Balbo, M.; Balis, D.; Balkowski, C.; Ballester, O.; Ballet, J.; Balzer, A.; Bamba, A.; Bandiera, R.; Barber, A.; Barbier, C.; Barcelo, M.; Barkov, M.; Barnacka, A.; de Almeida, U. Barres; Barrio, J. A.; Basso, S.; Bastieri, D.; Bauer, C.; Becciani, U.; Becherini, Y.; Tjus, J. Becker; Beckmann, V.; Bednarek, W.; Benbow, W.; Ventura, D. Benedico; Berdugo, J.; Berge, D.; Bernardini, E.; Bernardini, M. G.; Bernhard, S.; Bernlöhr, K.; Bertucci, B.; Besel, M. -A.; Beshley, V.; Bhatt, N.; Bhattacharjee, P.; Bhattacharyya, W.; Bhattachryya, S.; Biasuzzi, B.; Bicknell, G.; Bigongiari, C.; Biland, A.; Bilinsky, A.; Bilnik, W.; Biondo, B.; Bird, R.; Bird, T.; Bissaldi, E.; Bitossi, M.; Blanch, O.; Blasi, P.; Blazek, J.; Bockermann, C.; Boehm, C.; Bogacz, L.; Bogdan, M.; Bohacova, M.; Boisson, C.; Boix, J.; Bolmont, J.; Bonanno, G.; Bonardi, A.; Bonavolontà, C.; Bonifacio, P.; Bonnarel, F.; Bonnoli, G.; Borkowski, J.; Bose, R.; Bosnjak, Z.; Böttcher, M.; Bousquet, J. -J.; Boutonnet, C.; Bouyjou, F.; Bowman, L.; Braiding, C.; Brantseg, T.; Brau-Nogué, S.; Bregeon, J.; Briggs, M.; Brigida, M.; Bringmann, T.; Brisken, W.; Bristow, D.; Britto, R.; Brocato, E.; Bron, S.; Brook, P.; Brooks, W.; Brown, A. M.; Brügge, K.; Brun, F.; Brun, P.; Brun, P.; Brunetti, G.; Brunetti, L.; Bruno, P.; Buanes, T.; Bucciantini, N.; Buchholtz, G.; Buckley, J.; Bugaev, V.; Bühler, R.; Bulgarelli, A.; Bulik, T.; Burton, M.; Burtovoi, A.; Busetto, G.; Buson, S.; Buss, J.; Byrum, K.; Cadoux, F.; Tovar, J. Calvo; Cameron, R.; Canelli, F.; Canestrari, R.; Capalbi, M.; Capasso, M.; Capobianco, G.; Caproni, A.; Caraveo, P.; Cardenzana, J.; Cardillo, M.; Carius, S.; Carlile, C.; Carosi, A.; Carosi, R.; Carquín, E.; Carr, J.; Carroll, M.; Carter, J.; Carton, P. -H.; Casandjian, J. -M.; Casanova, S.; Casanova, S.; Cascone, E.; Casiraghi, M.; Castellina, A.; Mora, J. Castroviejo; Catalani, F.; Catalano, O.; Catalanotti, S.; Cauz, D.; Cavazzani, S.; Cerchiara, P.; Chabanne, E.; Chadwick, P.; Chaleil, T.; Champion, C.; Chatterjee, A.; Chaty, S.; Chaves, R.; Chen, A.; Chen, X.; Chen, X.; Cheng, K.; Chernyakova, M.; Chiappetti, L.; Chikawa, M.; Chinn, D.; Chitnis, V. R.; Cho, N.; Christov, A.; Chudoba, J.; Cieślar, M.; Ciocci, M. A.; Clay, R.; Colafrancesco, S.; Colin, P.; Colley, J. -M.; Colombo, E.; Colome, J.; Colonges, S.; Conforti, V.; Connaughton, V.; Connell, S.; Conrad, J.; Contreras, J. L.; Coppi, P.; Corbel, S.; Coridian, J.; Cornat, R.; Corona, P.; Corti, D.; Cortina, J.; Cossio, L.; Costa, A.; Costantini, H.; Cotter, G.; Courty, B.; Covino, S.; Covone, G.; Crimi, G.; Criswell, S. J.; Crocker, R.; Croston, J.; Cuadra, J.; Cumani, P.; Cusumano, G.; Da Vela, P.; Dale, Ø.; D'Ammando, F.; Dang, D.; Dang, V. T.; Dangeon, L.; Daniel, M.; Davids, I.; Davids, I.; Dawson, B.; Dazzi, F.; Costa, B. de Aguiar; De Angelis, A.; Cardoso, R. F. de Araujo; De Caprio, V.; Anjos, R. de Cássia dos; De Cesare, G.; De Franco, A.; De Frondat, F.; Pino, E. M. de Gouveia Dal; de la Calle, I.; De Lisio, C.; Lopez, R. de los Reyes; De Lotto, B.; De Luca, A.; Neto, J. R. T. de Mello; de Naurois, M.; Wilhelmi, E. de Oña; De Palma, F.; De Persio, F.; de Souza, V.; Decock, G.; Decock, J.; Deil, C.; Del Santo, M.; Delagnes, E.; Deleglise, G.; Delgado, C.; Delgado, J.; della Volpe, D.; Deloye, P.; Detournay, M.; Dettlaff, A.; Devin, J.; Di Girolamo, T.; Di Giulio, C.; Di Paola, A.; Di Pierro, F.; Diaz, M. A.; Díaz, C.; Dib, C.; Dick, J.; Dickinson, H.; Diebold, S.; Digel, S.; Dipold, J.; Disset, G.; Distefano, A.; Djannati-Ataï, A.; Doert, M.; Dohmke, M.; Domínguez, A.; Dominik, N.; Dominique, J. -L.; Prester, D. Dominis; Donat, A.; Donnarumma, I.; Dorner, D.; Doro, M.; Dournaux, J. -L.; Downes, T.; Doyle, K.; Drake, G.; Drappeau, S.; Drass, H.; Dravins, D.; Drury, L.; Dubus, G.; Ducci, L.; Dumas, D.; Morå, K. Dundas; Durand, D.; D'Urso, D.; Dwarkadas, V.; Dyks, J.; Dyrda, M.; Ebr, J.; Edy, E.; Egberts, K.; Eger, P.; Egorov, A.; Einecke, S.; Eisch, J.; Eisenkolb, F.; Eleftheriadis, C.; Elsaesser, D.; Elsässer, D.; Emmanoulopoulos, D.; Engelbrecht, C.; Engelhaupt, D.; Ernenwein, J. -P.; Escarate, P.; Eschbach, S.; Espinoza, C.; Evans, P.; Fairbairn, M.; Falceta-Goncalves, D.; Falcone, A.; Ramazani, V. Fallah; Fantinel, D.; Farakos, K.; Farnier, C.; Farrell, E.; Fasola, G.; Favre, Y.; Fede, E.; Fedora, R.; Fedorova, E.; Fegan, S.; Ferenc, D.; Fernandez-Alonso, M.; Fernández-Barral, A.; Ferrand, G.; Ferreira, O.; Fesquet, M.; Fetfatzis, P.; Fiandrini, E.; Fiasson, A.; Filipčič, A.; Filipovic, M.; Fink, D.; Finley, C.; Finley, J. P.; Finoguenov, A.; Fioretti, V.; Fiorini, M.; Fleischhack, H.; Flores, H.; Florin, D.; Föhr, C.; Fokitis, E.; Fonseca, M. V.; Font, L.; Fontaine, G.; Fontes, B.; Fornasa, M.; Fornasa, M.; Förster, A.; Fortin, P.; Fortson, L.; Fouque, N.; Franckowiak, A.; Franckowiak, A.; Franco, F. J.; Albuquerque, I. Freire Mota; Coromina, L. Freixas; Fresnillo, L.; Fruck, C.; Fuessling, M.; Fugazza, D.; Fujita, Y.; Fukami, S.; Fukazawa, Y.; Fukuda, T.; Fukui, Y.; Funk, S.; Furniss, A.; Gäbele, W.; Gabici, S.; Gadola, A.; Galindo, D.; Gall, D. D.; Gallant, Y.; Galloway, D.; Gallozzi, S.; Galvez, J. A.; Gao, S.; Garcia, A.; Garcia, B.; Gil, R. García; López, R. Garcia; Garczarczyk, M.; Gardiol, D.; Gargano, C.; Gargano, F.; Garozzo, S.; Garrecht, F.; Garrido, L.; Garrido-Ruiz, M.; Gascon, D.; Gaskins, J.; Gaudemard, J.; Gaug, M.; Gaweda, J.; Gebhardt, B.; Gebyehu, M.; Geffroy, N.; Genolini, B.; Gerard, L.; Ghalumyan, A.; Ghedina, A.; Ghislain, P.; Giammaria, P.; Giannakaki, E.; Gianotti, F.; Giarrusso, S.; Giavitto, G.; Giebels, B.; Gieras, T.; Giglietto, N.; Gika, V.; Gimenes, R.; Giomi, M.; Giommi, P.; Giordano, F.; Giovannini, G.; Girardot, P.; Giro, E.; Giroletti, M.; Gironnet, J.; Giuliani, A.; Glicenstein, J. -F.; Gnatyk, R.; Godinovic, N.; Goldoni, P.; Gomez, G.; Gonzalez, M. M.; González, A.; Gora, D.; Gothe, K. S.; Gotz, D.; Goullon, J.; Grabarczyk, T.; Graciani, R.; Graham, J.; Grandi, P.; Granot, J.; Grasseau, G.; Gredig, R.; Green, A. J.; Green, A. M.; Greenshaw, T.; Grenier, I.; Griffiths, S.; Grillo, A.; Grondin, M. -H.; Grube, J.; Grudzinska, M.; Grygorczuk, J.; Guarino, V.; Guberman, D.; Gunji, S.; Gyuk, G.; Hadasch, D.; Hagedorn, A.; Hagge, L.; Hahn, J.; Hakobyan, H.; Hara, S.; Hardcastle, M. J.; Hassan, T.; Hatanaka, K.; Haubold, T.; Haupt, A.; Hayakawa, T.; Hayashida, M.; Heller, M.; Heller, R.; Helo, J. C.; Henault, F.; Henri, G.; Hermann, G.; Hermel, R.; Llorente, J. Herrera; Llorente, J. Herrera; Herrero, A.; Hervet, O.; Hidaka, N.; Hinton, J.; Hirai, W.; Hirotani, K.; Hnatyk, B.; Hoang, J.; Hoffmann, D.; Hofmann, W.; Holch, T.; Holder, J.; Hooper, S.; Horan, D.; Hörandel, J.; Hörbe, M.; Horns, D.; Horvath, P.; Hose, J.; Houles, J.; Hovatta, T.; Hrabovsky, M.; Hrupec, D.; Huet, J. -M.; Huetten, M.; Hughes, G.; Hui, D.; Humensky, T. B.; Hussein, M.; Iacovacci, M.; Ibarra, A.; Ikeno, Y.; Illa, J. M.; Impiombato, D.; Inada, T.; Incorvaia, S.; Infante, L.; Inome, Y.; Inoue, S.; Inoue, T.; Inoue, Y.; Iocco, F.; Ioka, K.; Iori, M.; Ishio, K.; Ishio, K.; Israel, G. L.; Iwamura, Y.; Jablonski, C.; Jacholkowska, A.; Jacquemier, J.; Jamrozy, M.; Janecek, P.; Janiak, M.; Jankowsky, D.; Jankowsky, F.; Jean, P.; Jegouzo, I.; Jenke, P.; Jimenez, J. J.; Jingo, M.; Jingo, M.; Jocou, L.; Jogler, T.; Johnson, C. A.; Jones, M.; Josselin, M.; Journet, L.; Jung, I.; Kaaret, P.; Kagaya, M.; Kakuwa, J.; Kalekin, O.; Kalkuhl, C.; Kamon, H.; Kankanyan, R.; Karastergiou, A.; Kärcher, K.; Karczewski, M.; Karkar, S.; Karn, P.; Kasperek, J.; Katagiri, H.; Kataoka, J.; Katarzyński, K.; Kato, S.; Katz, U.; Kawanaka, N.; Kaye, L.; Kazanas, D.; Kelley-Hoskins, N.; Kersten, J.; Khélifi, B.; Kieda, D. B.; Kihm, T.; Kimeswenger, S.; Kisaka, S.; Kishida, S.; Kissmann, R.; Klepser, S.; Kluźniak, W.; Knapen, J.; Knapp, J.; Knödlseder, J.; Koch, B.; Köck, F.; Kocot, J.; Kohri, K.; Kokkotas, K.; Kokkotas, K.; Kolitzus, D.; Komin, N.; Kominis, I.; Kong, A.; Konno, Y.; Kosack, K.; Koss, G.; Kossatz, M.; Kowal, G.; Koyama, S.; Kozioł, J.; Kraus, M.; Krause, J.; Krause, M.; Krawzcynski, H.; Krennrich, F.; Kretzschmann, A.; Kruger, P.; Kubo, H.; Kudryavtsev, V.; Mezek, G. Kukec; Kuklis, M.; Kuroda, H.; Kushida, J.; La Barbera, A.; La Palombara, N.; La Parola, V.; La Rosa, G.; Laffon, H.; Lahmann, R.; Lakicevic, M.; Lalik, K.; Lamanna, G.; Landriu, D.; Landt, H.; Lang, R. G.; Lapington, J.; Laporte, P.; Fèvre, J. -P. Le; Flour, T. Le; Sidaner, P. Le; Lee, S. -H.; Lee, W. H.; Lees, J. -P.; Lefaucheur, J.; Leffhalm, K.; Leich, H.; de Oliveira, M. A. Leigui; Lelas, D.; Lemière, A.; Lemoine-Goumard, M.; Lenain, J. -P.; Leonard, R.; Leoni, R.; Lessio, L.; Leto, G.; Leveque, A.; Lieunard, B.; Limon, M.; Lindemann, R.; Lindfors, E.; Linhoff, L.; Liolios, A.; Lipniacka, A.; Lockart, H.; Lohse, T.; Łokas, E.; Lombardi, S.; Longo, F.; Lopatin, A.; Lopez, M.; Loreggia, D.; Louge, T.; Louis, F.; Louys, M.; Lucarelli, F.; Lucchesi, D.; Lüdecke, H.; Luigi, T.; Luque-Escamilla, P. L.; Lyard, E.; Maccarone, M. C.; Maccarone, T.; Maccarone, T. J.; Mach, E.; Madejski, G. M.; Madonna, A.; Magniette, F.; Magniez, A.; Mahabir, M.; Maier, G.; Majumdar, P.; Majumdar, P.; Makariev, M.; Malaguti, G.; Malaspina, G.; Mallot, A. K.; Malouf, A.; Maltezos, S.; Malyshev, D.; Mancilla, A.; Mandat, D.; Maneva, G.; Manganaro, M.; Mangano, S.; Manigot, P.; Mankushiyil, N.; Mannheim, K.; Maragos, N.; Marano, D.; Marchegiani, P.; Marcomini, J. A.; Marcowith, A.; Mariotti, M.; Marisaldi, M.; Markoff, S.; Martens, C.; Martí, J.; Martin, J. -M.; Martin, L.; Martin, P.; Martínez, G.; Martínez, M.; Martínez, O.; Martynyuk-Lototskyy, K.; Marx, R.; Masetti, N.; Massimino, P.; Mastichiadis, A.; Mastroianni, S.; Mastropietro, M.; Masuda, S.; Matsumoto, H.; Matsuoka, S.; Matthews, N.; Mattiazzo, S.; Maurin, G.; Maxted, N.; Maxted, N.; Maya, J.; Mayer, M.; Mazin, D.; Mazziotta, M. N.; Comb, L. Mc; McCubbin, N.; McHardy, I.; Medina, C.; Mehrez, F.; Melioli, C.; Melkumyan, D.; Melse, T.; Mereghetti, S.; Merk, M.; Mertsch, P.; Meunier, J. -L.; Meures, T.; Meyer, M.; Meyrelles, J. L.; Miccichè, A.; Michael, T.; Michałowski, J.; Mientjes, P.; Mievre, I.; Mihailidis, A.; Miller, J.; Mineo, T.; Minuti, M.; Mirabal, N.; Mirabel, F.; Miranda, J. M.; Mirzoyan, R.; Mitchell, A.; Mizuno, T.; Moderski, R.; Mognet, I.; Mohammed, M.; Moharana, R.; Mohrmann, L.; Molinari, E.; Molyneux, P.; Monmarthe, E.; Monnier, G.; Montaruli, T.; Monte, C.; Monteiro, I.; Mooney, D.; Moore, P.; Moralejo, A.; Morello, C.; Moretti, E.; Mori, K.; Morris, P.; Morselli, A.; Moscato, F.; Motohashi, D.; Mottez, F.; Moudden, Y.; Moulin, E.; Mueller, S.; Mukherjee, R.; Munar, P.; Munari, M.; Mundell, C.; Mundet, J.; Muraishi, H.; Murase, K.; Muronga, A.; Murphy, A.; Nagar, N.; Nagataki, S.; Nagayoshi, T.; Nagesh, B. K.; Naito, T.; Nakajima, D.; Nakajima, D.; Nakamori, T.; Nakayama, K.; Nanni, J.; Naumann, D.; Nayman, P.; Nellen, L.; Nemmen, R.; Neronov, A.; Neyroud, N.; Nguyen, T.; Nguyen, T. T.; Trung, T. Nguyen; Nicastro, L.; Nicolau-Kukliński, J.; Niederwanger, F.; Niedźwiecki, A.; Niemiec, J.; Nieto, D.; Nievas-Rosillo, M.; Nikolaidis, A.; Nikołajuk, M.; Nishijima, K.; Nishikawa, K. -I.; Nishiyama, G.; Noda, K.; Noda, K.; Nogues, L.; Nolan, S.; Northrop, R.; Nosek, D.; Nöthe, M.; Novosyadlyj, B.; Nozka, L.; Nunio, F.; Oakes, L.; O'Brien, P.; Ocampo, C.; Occhipinti, G.; Ochoa, J. P.; de Bhroithe, A. OFaolain; Oger, R.; Ohira, Y.; Ohishi, M.; Ohm, S.; Ohoka, H.; Okazaki, N.; Okumura, A.; Olive, J. -F.; Olszowski, D.; Ong, R. A.; Ono, S.; Orienti, M.; Orito, R.; Orlati, A.; Osborne, J.; Ostrowski, M.; Ottaway, D.; Otte, N.; Öttl, S.; Ovcharov, E.; Oya, I.; Ozieblo, A.; Padovani, M.; Pagano, I.; Paiano, S.; Paizis, A.; Palacio, J.; Palatka, M.; Pallotta, J.; Panagiotidis, K.; Panazol, J. -L.; Paneque, D.; Panter, M.; Panzera, M. R.; Paoletti, R.; Paolillo, M.; Papayannis, A.; Papyan, G.; Paravac, A.; Paredes, J. M.; Pareschi, G.; Park, N.; Parsons, D.; Paśko, P.; Pavy, S.; Pech, M.; Peck, A.; Pedaletti, G.; Pe'er, A.; Peet, S.; Pelat, D.; Pepato, A.; Perez, M. d. C.; Perri, L.; Perri, M.; Persic, M.; Persic, M.; Petrashyk, A.; Petrucci, P. -O.; Petruk, O.; Peyaud, B.; Pfeifer, M.; Pfeiffer, G.; Piano, G.; Pieloth, D.; Pierre, E.; de Pinho, F. Pinto; García, C. Pio; Piret, Y.; Pisarski, A.; Pita, S.; Platos, Ł.; Platzer, R.; Podkladkin, S.; Pogosyan, L.; Pohl, M.; Poinsignon, P.; Pollo, A.; Porcelli, A.; Porthault, J.; Potter, W.; Poulios, S.; Poutanen, J.; Prandini, E.; Prandini, E.; Prast, J.; Pressard, K.; Principe, G.; Profeti, F.; Prokhorov, D.; Prokoph, H.; Prouza, M.; Pruchniewicz, R.; Pruteanu, G.; Pueschel, E.; Pühlhofer, G.; Puljak, I.; Punch, M.; Pürckhauer, S.; Pyzioł, R.; Queiroz, F.; Quel, E. J.; Quinn, J.; Quirrenbach, A.; Rafighi, I.; Rainò, S.; Rajda, P. J.; Rameez, M.; Rando, R.; Rannot, R. C.; Rataj, M.; Ravel, T.; Razzaque, S.; Reardon, P.; Reichardt, I.; Reimann, O.; Reimer, A.; Reimer, O.; Reisenegger, A.; Renaud, M.; Renner, S.; Reposeur, T.; Reville, B.; Rezaeian, A.; Rhode, W.; Ribeiro, D.; Prado, R. Ribeiro; Ribó, M.; Richards, G.; Richer, M. G.; Richtler, T.; Rico, J.; Ridky, J.; Rieger, F.; Riquelme, M.; Ristori, P. R.; Rivoire, S.; Rizi, V.; Roache, E.; Rodriguez, J.; Fernandez, G. Rodriguez; Vázquez, J. J. Rodríguez; Rojas, G.; Romano, P.; Romeo, G.; Roncadelli, M.; Rosado, J.; Rose, J.; Rosen, S.; Lees, S. Rosier; Ross, D.; Rouaix, G.; Rousselle, J.; Rovero, A. C.; Rowell, G.; Roy, F.; Royer, S.; Rubini, A.; Rudak, B.; Rugliancich, A.; Rujopakarn, W.; Rulten, C.; Rupiński, M.; Russo, F.; Russo, F.; Rutkowski, K.; Saavedra, O.; Sabatini, S.; Sacco, B.; Sadeh, I.; Saemann, E. O.; Safi-Harb, S.; Saggion, A.; Sahakian, V.; Saito, T.; Sakaki, N.; Sakurai, S.; Salamon, A.; Salega, M.; Salek, D.; Greus, F. Salesa; Salgado, J.; Salina, G.; Salinas, L.; Salini, A.; Sanchez, D.; Sanchez-Conde, M.; Sandaker, H.; Sandoval, A.; Sangiorgi, P.; Sanguillon, M.; Sano, H.; Santander, M.; Santangelo, A.; Santos, E. M.; Santos-Lima, R.; Sanuy, A.; Sapozhnikov, L.; Sarkar, S.; Satalecka, K.; Satalecka, K.; Sato, Y.; Savalle, R.; Sawada, M.; Sayède, F.; Schanne, S.; Schanz, T.; Schioppa, E. J.; Schlenstedt, S.; Schmid, J.; Schmidt, T.; Schmoll, J.; Schneider, M.; Schoorlemmer, H.; Schovanek, P.; Schubert, A.; Schullian, E. -M.; Schultze, J.; Schulz, A.; Schulz, S.; Schure, K.; Schussler, F.; Schwab, T.; Schwanke, U.; Schwarz, J.; Schweizer, T.; Schwemmer, S.; Schwendicke, U.; Schwerdt, C.; Sciacca, E.; Scuderi, S.; Segreto, A.; Seiradakis, J. -H.; Sembroski, G. H.; Semikoz, D.; Sergijenko, O.; Serre, N.; Servillat, M.; Seweryn, K.; Shafi, N.; Shalchi, A.; Sharma, M.; Shayduk, M.; Shellard, R. C.; Shibata, T.; Shigenaka, A.; Shilon, I.; Shum, E.; Sidoli, L.; Sidz, M.; Sieiro, J.; Siejkowski, H.; Silk, J.; Sillanpää, A.; Simone, D.; Simpson, H.; Singh, B. B.; Sinha, A.; Sironi, G.; Sitarek, J.; Sizun, P.; Sliusar, V.; Sliusar, V.; Smith, A.; Sobczyńska, D.; Sol, H.; Sottile, G.; Sowiński, M.; Spanier, F.; Spengler, G.; Spiga, R.; Stadler, R.; Stahl, O.; Stamerra, A.; Stanič, S.; Starling, R.; Staszak, D.; Stawarz, Ł.; Steenkamp, R.; Stefanik, S.; Stegmann, C.; Steiner, S.; Stella, C.; Stephan, M.; Stergioulas, N.; Sternberger, R.; Sterzel, M.; Stevenson, B.; Stinzing, F.; Stodulska, M.; Stodulski, M.; Stolarczyk, T.; Stratta, G.; Straumann, U.; Stringhetti, L.; Strzys, M.; Stuik, R.; Sulanke, K. -H.; Suomijärvi, T.; Supanitsky, A. D.; Suric, T.; Sushch, I.; Sutcliffe, P.; Sykes, J.; Szanecki, M.; Szepieniec, T.; Szwarnog, P.; Tacchini, A.; Tachihara, K.; Tagliaferri, G.; Tajima, H.; Takahashi, H.; Takahashi, K.; Takahashi, M.; Takalo, L.; Takami, S.; Takata, J.; Takeda, J.; Talbot, G.; Tam, T.; Tanaka, M.; Tanaka, S.; Tanaka, T.; Tanaka, Y.; Tanci, C.; Tanigawa, S.; Tavani, M.; Tavecchio, F.; Tavernet, J. -P.; Tayabaly, K.; Taylor, A.; Tejedor, L. A.; Telezhinsky, I.; Temme, F.; Temnikov, P.; Tenzer, C.; Terada, Y.; Terrazas, J. C.; Terrier, R.; Terront, D.; Terzic, T.; Tescaro, D.; Teshima, M.; Teshima, M.; Testa, V.; Tezier, D.; Thayer, J.; Thornhill, J.; Thoudam, S.; Thuermann, D.; Tibaldo, L.; Tiengo, A.; Timpanaro, M. C.; Tiziani, D.; Tluczykont, M.; Peixoto, C. J. Todero; Tokanai, F.; Tokarz, M.; Toma, K.; Tomastik, J.; Tomono, Y.; Tonachini, A.; Tonev, D.; Torii, K.; Tornikoski, M.; Torres, D. F.; Torres, M.; Torresi, E.; Toso, G.; Tosti, G.; Totani, T.; Tothill, N.; Toussenel, F.; Tovmassian, G.; Toyama, T.; Travnicek, P.; Trichard, C.; Trifoglio, M.; Pujadas, I. Troyano; Trzeciak, M.; Tsinganos, K.; Tsujimoto, S.; Tsuru, T.; Uchiyama, Y.; Umana, G.; Umetsu, Y.; Upadhya, S. S.; Uslenghi, M.; Vagelli, V.; Vagnetti, F.; Valdes-Galicia, J.; Valentino, M.; Vallania, P.; Valore, L.; van Driel, W.; van Eldik, C.; van Soelen, B.; Vandenbroucke, J.; Vanderwalt, J.; Vasileiadis, G.; Vassiliev, V.; Vázquez, J. R.; Acosta, M. L. Vázquez; Vecchi, M.; Vega, A.; Vegas, I.; Veitch, P.; Venault, P.; Venema, L.; Venter, C.; Vercellone, S.; Vergani, S.; Verma, K.; Verzi, V.; Vettolani, G. P.; Veyssiere, C.; Viana, A.; Viaux, N.; Vicha, J.; Vigorito, C.; Vincent, P.; Vincent, S.; Vink, J.; Vittorini, V.; Vlahakis, N.; Vlahos, L.; Voelk, H.; Voisin, V.; Vollhardt, A.; Volpicelli, A.; von Brand, H.; Vorobiov, S.; Vovk, I.; Vrastil, M.; Vu, L. V.; Vuillaume, T.; Wagner, R.; Wagner, R.; Wagner, S. J.; Wakely, S. P.; Walstra, T.; Walter, R.; Walther, T.; Ward, J. E.; Ward, M.; Warda, K.; Warren, D.; Wassberg, S.; Watson, J. J.; Wawer, P.; Wawrzaszek, R.; Webb, N.; Wegner, P.; Weiner, O.; Weinstein, A.; Wells, R.; Werner, F.; Wetteskind, H.; White, M.; White, R.; Więcek, M.; Wierzcholska, A.; Wiesand, S.; Wijers, R.; Wilcox, P.; Wild, N.; Wilhelm, A.; Wilkinson, M.; Will, M.; Will, M.; Williams, D. A.; Williams, J. T.; Willingale, R.; Wilson, N.; Winde, M.; Winiarski, K.; Winkler, H.; Winter, M.; Wischnewski, R.; Witt, E.; Wojcik, P.; Wolf, D.; Wood, M.; Wörnlein, A.; Wu, E.; Wu, T.; Yadav, K. K.; Yamamoto, H.; Yamamoto, T.; Yamane, N.; Yamazaki, R.; Yanagita, S.; Yang, L.; Yelos, D.; Yoshida, A.; Yoshida, M.; Yoshida, T.; Yoshiike, S.; Yoshikoshi, T.; Yu, P.; Zabalza, V.; Zaborov, D.; Zacharias, M.; Zaharijas, G.; Zajczyk, A.; Zampieri, L.; Zandanel, F.; Sanchez, R. Zanmar; Zaric, D.; Zavrtanik, D.; Zavrtanik, M.; Zdziarski, A.; Zech, A.; Zechlin, H.; Zhao, A.; Zhdanov, V.; Ziegler, A.; Ziemann, J.; Ziętara, K.; Zink, A.; Ziółkowski, J.; Zitelli, V.; Zoli, A.; Zorn, J.; Żychowski, P.
Comments: Index of CTA conference proceedings for the Gamma 2016, Heidelberg, Germany
Submitted: 2016-10-17
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
[20]  oai:arXiv.org:1610.01867  [pdf] - 1580349
The Single Mirror Small Sized Telescope For The Cherenkov Telescope Array
Comments: 7 pages, figure 6, Conference Gamma 2016 in Heildelberg
Submitted: 2016-10-06
The Small Size Telescope with Single Mirror (SST-1M) is one of the proposed types of Small Size Telescopes (SST) for the Cherenkov Telescope Array (CTA). About 70 SST telescopes will be part the CTA southern array which will also include Medium Sized Telescopes (MST) in its threshold configuration. Optimized for the detection of gamma rays in the energy range from 5 TeV to 300 TeV, the SST-1M uses a Davies-Cotton optics with a 4 m dish diameter with a field of view of 9 degrees. The Cherenkov light resulting from the interaction of the gamma-rays in the atmosphere is focused onto a 88 cm side-to-side hexagonal photo-detection plane. The latter is composed of 1296 hollow light guides coupled to large area hexagonal silicon photomultipliers (SiPM). The SiPM readout is fully digital readout as for the trigger system. The compact and lightweight design of the SST-1M camera offers very high performance ideal for gamma-ray observation requirement. In this contribution, the concept, design, performance and status of the first telescope prototype are presented.
[21]  oai:arXiv.org:1607.03412  [pdf] - 1542692
An innovative silicon photomultiplier digitizing camera for gamma-ray astronomy
Comments: 30 pages, 61 figures
Submitted: 2016-07-12
The single-mirror small-size telescope (SST-1M) is one of the three proposed designs for the small-size telescopes (SSTs) of the Cherenkov Telescope Array (CTA) project. The SST-1M will be equipped with a 4 m-diameter segmented mirror dish and an innovative fully digital camera based on silicon photo-multipliers (SiPMs). Since the SST sub-array will consist of up to 70 telescopes, the challenge is not only to build a telescope with excellent performance, but also to design it so that its components can be commissioned, assembled and tested by industry. In this paper we review the basic steps that led to the design concepts for the SST-1M camera and the ongoing realization of the first prototype, with focus on the innovative solutions adopted for the photodetector plane and the readout and trigger parts of the camera. In addition, we report on results of laboratory measurements on real scale elements that validate the camera design and show that it is capable of matching the CTA requirements of operating up to high-moon-light background conditions.
[22]  oai:arXiv.org:1509.01824  [pdf] - 1938100
Prototype of the SST-1M Telescope Structure for the Cherenkov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-09-06
A single-mirror small-size (SST-1M) Davies-Cotton telescope with a dish diameter of 4 m has been built by a consortium of Polish and Swiss institutions as a prototype for one of the proposed small-size telescopes for the southern observatory of the Cherenkov Telescope Array (CTA). The design represents a very simple, reliable, and cheap solution. The mechanical structure prototype with its drive system is now being tested at the Institute of Nuclear Physics PAS in Krakow. Here we present the design of the prototype and results of the performance tests of the structure and the drive and control system.
[23]  oai:arXiv.org:1509.00266  [pdf] - 1938092
Using muon rings for the optical throughput calibration of the SST-1M prototype for the Cherenkov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-09-01
Imaging Atmospheric Cherenkov Telescopes (IACTs) are ground-based instruments devoted to the study of very high energy gamma-rays coming from space. The detection technique consists of observing images created by the Cherenkov light emitted when gamma rays, or more generally cosmic rays, propagate through the atmosphere. While in the case of protons or gamma-rays the images present a filled and more or less elongated shape, energetic muons penetrating the atmosphere are visualised as characteristic circular rings or arcs. A relatively simple analysis of the ring images allows the reconstruction of all the relevant parameters of the detected muons, such as the energy, the impact parameter, and the incoming direction, with the final aim to use them to calibrate the total optical throughput of the given IACT telescope. We present the results of preliminary studies on the use of images created by muons as optical throughput calibrators of the single mirror small size telescope prototype SST-1M proposed for the Cherenkov Telescope Array.
[24]  oai:arXiv.org:1508.07472  [pdf] - 1941990
Software design for the control system for Small-Size Telescopes with single-mirror of the Cherenkov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-08-29
The Small-Size Telescope with single-mirror (SST-1M) is a 4 m Davies-Cotton telescope and is among the proposed telescope designs for the Cherenkov Telescope Array (CTA). It is conceived to provide the high-energy ($>$ few TeV) coverage. The SST-1M contains proven technology for the telescope structure and innovative electronics and photosensors for the camera. Its design is meant to be simple, low-budget and easy-to-build industrially. Each device subsystem of an SST-1M telescope is made visible to CTA through a dedicated industrial standard server. The software is being developed in collaboration with the CTA Medium-Size Telescopes to ensure compatibility and uniformity of the array control. Early operations of the SST-1M prototype will be performed with a subset of the CTA central array control system based on the Alma Common Software (ACS). The triggered event data are time stamped, formatted and finally transmitted to the CTA data acquisition. The software system developed to control the devices of an SST-1M telescope is described, as well as the interface between the telescope abstraction to the CTA central control and the data acquisition system.
[25]  oai:arXiv.org:1508.06795  [pdf] - 1938078
Development of the optical system for the SST-1M telescope of the Cherenkov Telescope Array observatory
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-08-27
The prototype of a Davies-Cotton small size telescope (SST-1M) has been designed and developed by a consortium of Polish and Swiss institutions and proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose of the optical system is to focus the Cherenkov light emitted by extensive air showers in the atmosphere onto the focal plane detectors. The main component of the system is a dish consisting of 18 hexagonal mirrors with a total effective collection area of 6.47 m2 (including the shadowing and estimated mirror reflectivity). Such a solution was chosen taking into account the analysis of the Cherenkov light propagation and based on optical simulations. The proper curvature and stability of the dish is ensured by the mirror alignment system and the isostatic interface to the telescope structure. Here we present the design of the optical subsystem together with the performance measurements of its components.
[26]  oai:arXiv.org:1508.06397  [pdf] - 1938071
Camera calibration strategy of the SST-1M prototype of the Cherenokov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-08-26
The SST-1M telescope is one of the prototypes under construction proposed to be part of the future Cherenkov Telescope Array. It uses a standard Davis-Cotton design for the optics and telescope structure, with a dish diameter of 4 meters and a large field-of-view of 9 degrees. The innovative camera design is composed of a photo-detection plane with 1296 pixels including entrance window, light concentrators, Silicon Photomultipliers (SiPMs), and pre-amplifier stages together with a fully digital readout and trigger electronics, DigiCam. In this contribution we give a general description of the analysis chain designed for the SST-1M prototype. In particular we focus on the calibration strategy used to convert the SiPM signals registered by DigiCam to the quantities needed for Cherenkov image analysis. The calibration is based on an online feedback system to stabilize the gain of the SiPMs, as well as dedicated events (dark count, pedestal, and light flasher events) to be taken during the normal operation of the prototype.
[27]  oai:arXiv.org:1508.06459  [pdf] - 1938074
Performance of the SST-1M telescope for the Cherenkov Telescope Array observatory
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-08-26
The single mirror small-size telescope (SST-1M) is one of the telescope projects being proposed for the Cherenkov Telescope Array observatory by a sub-consortium of Polish and Swiss institutions. The SST-1M prototype structure is currently being constructed at the Institute of Nuclear Physics in Cracow, Poland, while the camera will be assembled at the University of Geneva, Switzerland. This prototype enables measurements of parameters having a decisive influence on the telescope performance. We present results of numerical simulations of the SST-1M performance based on such measurements. The telescope effective area, the expected trigger rates and the optical point spread function are calculated.
[28]  oai:arXiv.org:1508.06453  [pdf] - 1266989
The SST-1M camera for the Cherenkov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894; Full consortium author list at http://cta-observatory.org
Submitted: 2015-08-26
The prototype camera of the single-mirror Small Size Telescopes (SST-1M) proposed for the Cherenkov Telescope Array (CTA) project has been designed to be very compact and to deliver high performance over thirty years of operation. The camera is composed of an hexagonal photo-detection plane made of custom designed large area hexagonal silicon photomultipliers and a high throughput, highly configurable, fully digital readout and trigger system (DigiCam). The camera will be installed on the telescope structure at the H. Niewodnicza{\'n}ski institute of Nuclear Physics in Krakow in fall 2015. In this contribution, we review the steps that led to the development of the innovative photo-detection plane and readout electronics, and we describe the test and calibration strategy adopted.
[29]  oai:arXiv.org:1508.06082  [pdf] - 1265844
DigiCam - Fully Digital Compact Read-out and Trigger Electronics for the SST-1M Telescope proposed for the Cherenkov Telescope Array
Comments: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.05894
Submitted: 2015-08-25
The SST-1M is one of three prototype small-sized telescope designs proposed for the Cherenkov Telescope Array, and is built by a consortium of Polish and Swiss institutions. The SST-1M will operate with DigiCam - an innovative, compact camera with fully digital read-out and trigger electronics. A high level of integration will be achieved by massively deploying state-of-the-art multi-gigabit transmission channels, beginning from the ADC flash converters, through the internal data and trigger signals transmission over backplanes and cables, to the camera's server link. Such an approach makes it possible to design the camera to fit the size and weight requirements of the SST-1M exactly, and provide low power consumption, high reliability and long lifetime. The structure of the digital electronics will be presented, along with main physical building blocks and the internal architecture of FPGA functional subsystems.
[30]  oai:arXiv.org:1503.07682  [pdf] - 1043181
The effect of the displacement damage on the Charge Collection Efficiency in Silicon Drift Detectors for the LOFT satellite
Comments: 17 pages, 7 figures. Accepted for publication by Journal of Instrumentation
Submitted: 2015-03-26
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displacement damage produced in the SDDs by the protons trapped in the Earth's magnetosphere. In a previous paper we discussed the effects of the Non Ionising Energy Losses from protons on the SDD leakage current. In this paper we report the measurement of the variation of Charge Collection Efficiency produced by displacement damage caused by protons and the comparison with the expected damage in orbit.
[31]  oai:arXiv.org:1408.6526  [pdf] - 864022
The Large Observatory For x-ray Timing
Feroci, M.; Herder, J. W. den; Bozzo, E.; Barret, D.; Brandt, S.; Hernanz, M.; van der Klis, M.; Pohl, M.; Santangelo, A.; Stella, L.; Watts, A.; Wilms, J.; Zane, S.; Ahangarianabhari, M.; Albertus, C.; Alford, M.; Alpar, A.; Altamirano, D.; Alvarez, L.; Amati, L.; Amoros, C.; Andersson, N.; Antonelli, A.; Argan, A.; Artigue, R.; Artigues, B.; Atteia, J. -L.; Azzarello, P.; Bakala, P.; Baldazzi, G.; Balman, S.; Barbera, M.; van Baren, C.; Bhattacharyya, S.; Baykal, A.; Belloni, T.; Bernardini, F.; Bertuccio, G.; Bianchi, S.; Bianchini, A.; Binko, P.; Blay, P.; Bocchino, F.; Bodin, P.; Bombaci, I.; Bidaud, J. -M. Bonnet; Boutloukos, S.; Bradley, L.; Braga, J.; Brown, E.; Bucciantini, N.; Burderi, L.; Burgay, M.; Bursa, M.; Budtz-Jørgensen, C.; Cackett, E.; Cadoux, F. R.; Cais, P.; Caliandro, G. A.; Campana, R.; Campana, S.; Capitanio, F.; Casares, J.; Casella, P.; Castro-Tirado, A. J.; Cavazzuti, E.; Cerda-Duran, P.; Chakrabarty, D.; Château, F.; Chenevez, J.; Coker, J.; Cole, R.; Collura, A.; Cornelisse, R.; Courvoisier, T.; Cros, A.; Cumming, A.; Cusumano, G.; D'Aì, A.; D'Elia, V.; Del Monte, E.; De Luca, A.; De Martino, D.; Dercksen, J. P. C.; De Pasquale, M.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; Diebold, S.; Di Salvo, T.; Donnarumma, I.; Drago, A.; Durant, M.; Emmanoulopoulos, D.; Erkut, M. H.; Esposito, P.; Evangelista, Y.; Fabian, A.; Falanga, M.; Favre, Y.; Feldman, C.; Ferrari, V.; Ferrigno, C.; Finger, M.; Finger, M. H.; Fraser, G. W.; Frericks, M.; Fuschino, F.; Gabler, M.; Galloway, D. K.; Sanchez, J. L. Galvez; Garcia-Berro, E.; Gendre, B.; Gezari, S.; Giles, A. B.; Gilfanov, M.; Giommi, P.; Giovannini, G.; Giroletti, M.; Gogus, E.; Goldwurm, A.; Goluchová, K.; Götz, D.; Gouiffes, C.; Grassi, M.; Groot, P.; Gschwender, M.; Gualtieri, L.; Guidorzi, C.; Guy, L.; Haas, D.; Haensel, P.; Hailey, M.; Hansen, F.; Hartmann, D. H.; Haswell, C. A.; Hebeler, K.; Heger, A.; Hermsen, W.; Homan, J.; Hornstrup, A.; Hudec, R.; Huovelin, J.; Ingram, A.; Zand, J. J. M. in't; Israel, G.; Iwasawa, K.; Izzo, L.; Jacobs, H. M.; Jetter, F.; Johannsen, T.; Jacobs, H. M.; Jonker, P.; Josè, J.; Kaaret, P.; Kanbach, G.; Karas, V.; Karelin, D.; Kataria, D.; Keek, L.; Kennedy, T.; Klochkov, D.; Kluzniak, W.; Kokkotas, K.; Korpela, S.; Kouveliotou, C.; Kreykenbohm, I.; Kuiper, L. M.; Kuvvetli, I.; Labanti, C.; Lai, D.; Lamb, F. K.; Laubert, P. P.; Lebrun, F.; Lin, D.; Linder, D.; Lodato, G.; Longo, F.; Lund, N.; Maccarone, T. J.; Macera, D.; Maestre, S.; Mahmoodifar, S.; Maier, D.; Malcovati, P.; Mandel, I.; Mangano, V.; Manousakis, A.; Marisaldi, M.; Markowitz, A.; Martindale, A.; Matt, G.; McHardy, I. M.; Melatos, A.; Mendez, M.; Mereghetti, S.; Michalska, M.; Migliari, S.; Mignani, R.; Miller, M. C.; Miller, J. M.; Mineo, T.; Miniutti, G.; Morsink, S.; Motch, C.; Motta, S.; Mouchet, M.; Mouret, G.; Mulačová, J.; Muleri, F.; Muñoz-Darias, T.; Negueruela, I.; Neilsen, J.; Norton, A. J.; Nowak, M.; O'Brien, P.; Olsen, P. E. H.; Orienti, M.; Orio, M.; Orlandini, M.; Orleanski, P.; Osborne, J. P.; Osten, R.; Ozel, F.; Pacciani, L.; Paolillo, M.; Papitto, A.; Paredes, J. M.; Patruno, A.; Paul, B.; Perinati, E.; Pellizzoni, A.; Penacchioni, A. V.; Perez, M. A.; Petracek, V.; Pittori, C.; Pons, J.; Portell, J.; Possenti, A.; Poutanen, J.; Prakash, M.; Provost, P. Le; Psaltis, D.; Rambaud, D.; Ramon, P.; Ramsay, G.; Rapisarda, M.; Rachevski, A.; Rashevskaya, I.; Ray, P. S.; Rea, N.; Reddy, S.; Reig, P.; Aranda, M. Reina; Remillard, R.; Reynolds, C.; Rezzolla, L.; Ribo, M.; de la Rie, R.; Riggio, A.; Rios, A.; Gil, P. Rodríguez-; Rodriguez, J.; Rohlfs, R.; Romano, P.; Rossi, E. M. R.; Rozanska, A.; Rousseau, A.; Ryde, F.; Sabau-Graziati, L.; Sala, G.; Salvaterra, R.; Sanna, A.; Sandberg, J.; Scaringi, S.; Schanne, S.; Schee, J.; Schmid, C.; Shore, S.; Schneider, R.; Schwenk, A.; Schwope, A. D.; Seyler, J. -Y.; Shearer, A.; Smith, A.; Smith, D. M.; Smith, P. J.; Sochora, V.; Soffitta, P.; Soleri, P.; Spencer, A.; Stappers, B.; Steiner, A. W.; Stergioulas, N.; Stratta, G.; Strohmayer, T. E.; Stuchlik, Z.; Suchy, S.; Sulemainov, V.; Takahashi, T.; Tamburini, F.; Tauris, T.; Tenzer, C.; Tolos, L.; Tombesi, F.; Tomsick, J.; Torok, G.; Torrejon, J. M.; Torres, D. F.; Tramacere, A.; Trois, A.; Turolla, R.; Turriziani, S.; Uter, P.; Uttley, P.; Vacchi, A.; Varniere, P.; Vaughan, S.; Vercellone, S.; Vrba, V.; Walton, D.; Watanabe, S.; Wawrzaszek, R.; Webb, N.; Weinberg, N.; Wende, H.; Wheatley, P.; Wijers, R.; Wijnands, R.; Wille, M.; Wilson-Hodge, C. A.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Zampieri, L.; Zdunik, L.; Zdziarski, A.; Zhang, B.; Zwart, F.; Ayre, M.; Boenke, T.; van Damme, C. Corral; Kuulkers, E.; Lumb, D.
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91442T
Submitted: 2014-08-27, last modified: 2014-08-29
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
[32]  oai:arXiv.org:1408.6538  [pdf] - 864030
Optimisation of the design for the LOFT Large Area Detector Module
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 914462
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is an X-ray timing observatory that, with four other candidates, was considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class instrument operating in the 2-30 keV range, which is designed to perform X-ray timing of compact objects with unprecedented resolution down to millisecond time scales. Although LOFT was not downselected for launch, during the assessment most of the trade-offs have been closed, leading to a robust and well documented design that will be reproposed in future ESA calls. The building block of the LAD instrument is the Module, and in this paper we summarize the rationale for the module concept, the characteristics of the module and the trade-offs/optimisations which have led to the current design.
[33]  oai:arXiv.org:1408.6539  [pdf] - 864031
The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91442W
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is one of the five candidates that were considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class instrument operating in the 2-30keV range, which holds the capability to revolutionise studies of variability from X-ray sources on the millisecond time scales. The LAD instrument has now completed the assessment phase but was not down-selected for launch. However, during the assessment, most of the trade-offs have been closed leading to a robust and well documented design that will be re- proposed in future ESA calls. In this talk, we will summarize the characteristics of the LAD design and give an overview of the expectations for the instrument capabilities.
[34]  oai:arXiv.org:1404.2734  [pdf] - 1937959
Design, optimization and characterization of the light concentrators of the single-mirror small size telescopes of the Cherenkov Telescope Array
Comments: 23 pages, 17 figures
Submitted: 2014-04-10
The focal-plane camera of $\gamma$-ray telescopes frequently uses light concentrators in front of light sensors. The purpose of these concentrators is to increase the effective area of the camera as well as to reduce the stray light coming at large incident angles. These light concentrators are usually based on the Winston cone design. In this contribution we present the design of an hexagonal hollow light concentrator with a lateral profile optimized using a cubic B\'ezier function to achieve a higher collection efficiency in the angular region of interest. The design presented here is optimized for a Davies-Cotton telescope with primary mirror of about 4 meters of diameter and focal length of 5.6 m. The described concentrators are part of an innovative camera made up of silicon-photomultipliers sensors, although a similar approach can be used for other sizes of single-mirror telescopes with different camera sensors, including photomultipliers. The challenge of our approach is to achieve a cost-effective design suitable for standard industrial productions of both the plastic concentrator substrate and the reflective coating. At the same time we maximize the optical performance. In this paper we also describe the optical set-up to measure the absolute collection efficiency of the light guides and demonstrate our good understanding of the measured data using a professional light tracing simulation.
[35]  oai:arXiv.org:1403.3573  [pdf] - 797027
FACT -- The G-APD revolution in Cherenkov astronomy
Comments: Proceedings of the Nuclear Science Symposium and Medical Imaging Conference (IEEE-NSS/MIC), 2013
Submitted: 2014-03-14
Since two years, the FACT telescope is operating on the Canary Island of La Palma. Apart from its purpose to serve as a monitoring facility for the brightest TeV blazars, it was built as a major step to establish solid state photon counters as detectors in Cherenkov astronomy. The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes (G-APD), equipped with solid light guides to increase the effective light collection area of each sensor. Since no sense-line is available, a special challenge is to keep the applied voltage stable although the current drawn by the G-APD depends on the flux of night-sky background photons significantly varying with ambient light conditions. Methods have been developed to keep the temperature and voltage dependent response of the G-APDs stable during operation. As a cross-check, dark count spectra with high statistics have been taken under different environmental conditions. In this presentation, the project, the developed methods and the experience from two years of operation of the first G-APD based camera in Cherenkov astronomy under changing environmental conditions will be presented.
[36]  oai:arXiv.org:1308.1512  [pdf] - 1934965
FACT - The First G-APD Cherenkov Telescope: Status and Results
Comments:
Submitted: 2013-08-07
The First G-APD Cherenkov telescope (FACT) is the first telescope using silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the HEGRA CT3 telescope, still located at the Observatorio del Roque de los Muchachos, and it is successfully in operation since Oct. 2011. The use of Silicon devices promises a higher photon detection efficiency, more robustness and higher precision than photo-multiplier tubes. The FACT collaboration is investigating with which precision these devices can be operated on the long-term. Currently, the telescope is successfully operated from remote and robotic operation is under development. During the past months of operation, the foreseen monitoring program of the brightest known TeV blazars has been carried out, and first physics results have been obtained including a strong flare of Mrk501. An instantaneous flare alert system is already in a testing phase. This presentation will give an overview of the project and summarize its goals, status and first results.
[37]  oai:arXiv.org:1307.7892  [pdf] - 699793
FACT: Towards Robotic Operation of an Imaging Air Cherenkov Telescope
Comments: Poster presented at the 33rd ICRC (2013), 4 pages, 3 figures
Submitted: 2013-07-30
The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in October 2011. Since summer 2012, due to very smooth and stable operation, it is the first telescope of its kind that is routinely operated from remote, without the need for a data-taking crew on site. In addition, many standard tasks of operation are executed automatically without the need for manual interaction. Based on the experience gained so far, some alterations to improve the safety of the system are under development to allow robotic operation in the future. We present the setup and precautions used to implement remote operations and the experience gained so far, as well as the work towards robotic operation.
[38]  oai:arXiv.org:1307.3137  [pdf] - 1937867
4 m Davies-Cotton telescope for the Cherenkov Telescope Array
Comments: In Proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), Rio de Janeiro (Brazil). All CTA contributions at arXiv:1307.2232
Submitted: 2013-07-11
The Cherenkov Telescope Array (CTA) is the next generation very high energy gamma-ray observatory. It will consist of three classes of telescopes, of large, medium and small sizes. The small telescopes, of 4 m diameter, will be dedicated to the observations of the highest energy gamma-rays, above several TeV. We present the technical characteristics of a single mirror, 4 m diameter, Davies-Cotton telescope for the CTA and the performance of the sub-array consisting of the telescopes of this type. The telescope will be equipped with a fully digital camera based on custom made, hexagonal Geiger-mode avalanche photodiodes. The development of cameras based on such devices is an RnD since traditionally photomultipliers are used. The photodiodes are now being characterized at various institutions of the CTA Consortium. Glass mirrors will be used, although an alternative is being considered: composite mirrors that could be adopted if they meet the project requirements. We present a design of the telescope structure, its components and results of the numerical simulations of the telescope performance.
[39]  oai:arXiv.org:1304.1710  [pdf] - 680263
Design and Operation of FACT -- The First G-APD Cherenkov Telescope
Comments: Corresponding authors: T. Bretz and Q. Weitzel
Submitted: 2013-04-05
The First G-APD Cherenkov Telescope (FACT) is designed to detect cosmic gamma-rays with energies from several hundred GeV up to about 10 TeV using the Imaging Atmospheric Cherenkov Technique. In contrast to former or existing telescopes, the camera of the FACT telescope is comprised of solid-state Geiger-mode Avalanche Photodiodes (G-APD) instead of photomultiplier tubes for photo detection. It is the first full-scale device of its kind employing this new technology. The telescope is operated at the Observatorio del Roque de los Muchachos (La Palma, Canary Islands, Spain) since fall 2011. This paper describes in detail the design, construction and operation of the system, including hardware and software aspects. Technical experiences gained after one year of operation are discussed and conclusions with regard to future projects are drawn.
[40]  oai:arXiv.org:1209.1497  [pdf] - 1151206
LOFT: the Large Observatory For X-ray Timing
Feroci, M.; Herder, J. W. den; Bozzo, E.; Barret, D.; Brandt, S.; Hernanz, M.; van der Klis, M.; Pohl, M.; Santangelo, A.; Stella, L.; Watts, A.; Wilms, J.; Zane, S.; Ahangarianabhari, M.; Alpar, A.; Altamirano, D.; Alvarez, L.; Amati, L.; Amoros, C.; Andersson, N.; Antonelli, A.; Argan, A.; Artigue, R.; Azzarello, P.; Baldazzi, G.; Balman, S.; Barbera, M.; Belloni, T.; Bertuccio, G.; Bianchi, S.; Bianchini, A.; Bodin, P.; Bidaud, J. -M. Bonnet; Boutloukos, S.; Braga, J.; Brown, E.; Bucciantini, N.; Burderi, L.; Bursa, M.; Budtz-Jørgensen, C.; Cackett, E.; Cadoux, F. R.; Cais, P.; Caliandro, G. A.; Campana, R.; Campana, S.; Casella, P.; Chakrabarty, D.; Chenevez, J.; Coker, J.; Cole, R.; Collura, A.; Courvoisier, T.; Cros, A.; Cumming, A.; Cusumano, G.; D'Aì, A.; D'Elia, V.; Del Monte, E.; De Martino, D.; De Rosa, A.; Di Cosimo, S.; Diebold, S.; Di Salvo, T.; Donnarumma, I.; Drago, A.; Durant, M.; Emmanoulopoulos, D.; Evangelista, Y.; Fabian, A.; Falanga, M.; Favre, Y.; Feldman, C.; Ferrigno, C.; Finger, M. H.; Fraser, G. W.; Fuschino, F.; Galloway, D. K.; Sanchez, J. L. Galvez; Garcia-Berro, E.; Gendre, B.; Gezari, S.; Giles, A. B.; Gilfanov, M.; Giommi, P.; Giovannini, G.; Giroletti, M.; Goldwurm, A.; Götz, D.; Gouiffes, C.; Grassi, M.; Guidorzi, P. Groot C.; Haas, D.; Hansen, F.; Hartmann, D. H.; Haswe, C. A.; Heger, A.; Homan, J.; Hornstrup, A.; Hudec, R.; Huovelin, J.; Ingram, A.; Zand, J. J. M. in't; Isern, J.; Israe, G.; Izzo, L.; Jonker, P.; Kaaret, P.; Karas, V.; Karelin, D.; Kataria, D.; Keek, L.; Kennedy, T.; Klochkov, D.; Kluzniak, W.; Kokkotas, K.; Korpela, S.; Kouveliotou, C.; Kreykenbohm, I.; Kuiper, L. M.; Kuvvetli, I.; Labanti, C.; Lai, D.; Lamb, F. K.; Lebrun, F.; Lin, D.; Linder, D.; Lodato, G.; Longo, F.; Lund, N.; Maccarone, T. J.; Macera, D.; Maier, D.; Malcovati, P.; Mangano, V.; Manousakis, A.; Marisaldi, M.; Markowitz, A.; Martindale, A.; Matt, G.; McHardy, I. M.; Melatos, A.; Mendez, M.; Migliari, S.; Mignani, R.; Miller, M. C.; Miller, J. M.; Mineo, T.; Miniutti, G.; Morsink, S.; Motch, C.; Motta, S.; Mouchet, M.; Muleri, F.; Norton, A. J.; Nowak, M.; O'Brien, P.; Orienti, M.; Orio, M.; Orlandini, M.; Orleanski, P.; Osborne, J. P.; Osten, R.; Ozel, F.; Pacciani, L.; Papitto, A.; Paul, B.; Perinati, E.; Petracek, V.; Portell, J.; Poutanen, J.; Psaltis, D.; Rambaud, D.; Ramsay, G.; Rapisarda, M.; Rachevski, A.; Ray, P. S.; Rea, N.; Reddy, S.; Reig, P.; Aranda, M. Reina; Remillard, R.; Reynolds, C.; Rodríguez-Gil, P.; Rodriguez, J.; Romano, P.; Rossi, E. M. R.; Ryde, F.; Sabau-Graziati, L.; Sala, G.; Salvaterra, R.; Sanna, A.; Schanne, S.; Schee, J.; Schmid, C.; Schwenk, A.; Schwope, A. D.; Seyler, J. -Y.; Shearer, A.; Smith, A.; Smith, D. M.; Smith, P. J.; Sochora, V.; Soffitta, P.; Soleri, P.; Stappers, B.; Stelzer, B.; Stergioulas, N.; Stratta, G.; Strohmayer, T. E.; Stuchlik, Z.; Suchy, S.; Sulemainov, V.; Takahashi, T.; Tamburini, F.; Tenzer, C.; Tolos, L.; Torok, G.; Torrejon, J. M.; Torres, D. F.; Tramacere, A.; Trois, A.; Turriziani, S.; Uter, P.; Uttley, P.; Vacchi, A.; Varniere, P.; Vaughan, S.; Vercellone, S.; Vrba, V.; Walton, D.; Watanabe, S.; Wawrzaszek, R.; Webb, N.; Weinberg, N.; Wende, H.; Wheatley, P.; Wijers, R.; Wijnands, R.; Wille, M.; Wilson-Hodge, C. A.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Zampieri, L.; Zdziarski, A.; Zhang, B.
Comments: Proceedings of SPIE, Vol. 8443, Paper No. 8443-85, 2012
Submitted: 2012-09-07
The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultra-dense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to year-long transient outbursts. In this paper we report the current status of the project.
[41]  oai:arXiv.org:1209.1498  [pdf] - 1151207
A Large Area Detector proposed for the Large Observatory for X-ray Timing (LOFT)
Comments: Proceedings of SPIE, Vo. 8443, Paper No. 8443-87
Submitted: 2012-09-07
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed instrument with 20 times the collecting area of the best past timing missions (such as RXTE) over the 2-30 keV range, which holds the capability to revolutionize studies of X-ray variability down to the millisecond time scales. Its ground-breaking characteristic is a low mass per unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable weight. The development of such large but light experiment, with low mass and power per unit area, is now made possible by the recent advancements in the field of large-area silicon detectors - able to time tag an X-ray photon with an accuracy <10 {\mu}s and an energy resolution of ~260 eV at 6 keV - and capillary-plate X-ray collimators. In this paper, we will summarize the characteristics of the LAD instrument and give an overview of its capabilities.