Normalized to: Cadoux, F.
[1]
oai:arXiv.org:1912.05894 [pdf] - 2115146
A Mini-Imaging Air Cherenkov Telescope
Ekoume, S. Njoh;
Alispach, C.;
Cadoux, F.;
Coco, V.;
della Volpe, D.;
Favre, Y.;
Heller, M.;
Montaruli, T.;
Nagai, A.;
Neronov, A.;
Renier, Y.;
Troyano, I.
Submitted: 2019-12-12
In this paper we describe the different software and hardware elements of a
mini-telescope for the detection of cosmic rays and gamma-rays using the
Cherenkov light emitted by their induced particle showers in the atmosphere. We
estimate the physics reach of the standalone mini-telescope and present some
results of the measurements done at the Sauverny Observatory of the University
of Geneva and at the Saint-Luc Observatory, which demonstrate the ability of
the telescope to observe cosmic rays with energy above about 100 TeV. Such a
mini-telescope can constitute a cost-effective out-trigger array that can
surround other gamma-ray telescopes or extended air showers detector arrays.
Its development was born out of the desire to illustrate to students and
amateurs the cosmic ray and gamma-ray detection from ground, as an example of
what is done in experiments using larger telescopes. As a matter of fact, a
mini-telescope can be used in outreach night events. While outreach is becoming
more and more important in the scientific community to raise interest in the
general public, the realisation of the mini-telescope is also a powerful way to
train students on instrumentation such as photosensors, their associated
electronics, acquisition software and data taking. In particular, this
mini-telescope uses silicon photomultipliers (SiPM) and the dedicated ASIC,
CITIROC.
[2]
oai:arXiv.org:1908.06860 [pdf] - 1945116
Calibration and operation of SiPM-based cameras for gamma-ray astronomy
in presence of high night-sky light
Samarai, Imen Al;
Alispach, Cyril Martin;
Balbo, Matteo;
Barbano, Anastasia Maria;
Beshley, Vasyl;
Biland, Adrian;
Blazek, Jiri;
Błocki, Jacek;
Borkowski, Jerzy;
Bulik, Tomek;
Cadoux, Frank Raphael;
Chytka, Ladislav;
Coco, Victor;
De Angelis, Nicolas;
Della Volpe, Domenico;
Favre, Yannick;
Gieras, Tomasz;
Grudzińska, Mira;
Hamal, Petr;
Heller, Matthieu;
Hrabovsky, Miroslav;
Juryšek, Jakub;
Kasperek, Jerzy;
Koncewicz, Katarzyna;
Kotarba, Andrzej;
Lyard, Étienne;
Mach, Emil;
Mandat, Dusan;
Michal, Stanislav;
Michałowski, Jerzy;
Moderski, Rafal;
Montaruli, Teresa;
Nagai, Andrii;
Neise, Dominik;
Niemiec, Jacek;
Ekoume, Theodore Rodrigue Njoh;
Ostrowski, Michal;
Palatka, Miroslav;
Paśko, Paweł;
Pech, Miroslav;
Pilszyk, Bartłomiej;
Przybilski, Henry;
Rajda, Paweł;
Renier, Yves;
Rozwadowski, Paweł;
Schovanek, Petr;
Seweryn, Karol;
Sliusar, Vitali;
Smakulska, Dorota;
Sobczyńska, Dorota;
Stawarz, Łukasz;
Świerblewski, Jacek;
Świerk, Paweł;
Travnicek, Petr;
Pujadas, Isaac Troyano;
Walter, Roland;
Wiecek, Marek;
Zagdański, Aleksander;
Ziȩtara, Krzysztof
Submitted: 2019-08-19
The next generation of Cherenkov telescope cameras feature Silicon Photo
Multipliers (SiPM), which can guarantee excellent performance and allow for
observation also under moonlight, increasing duty-cycle and therefore the
physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree
optical FoV and a 1296-pixel SiPM camera, has been designed to meet the
requirements of the next generation of ground-based gamma-ray observatories at
the highest energies.
The large-scale production of the telescopes for array deployment has
required the development of a fully automated calibration strategy which relies
on a dedicated hardware, the Camera Test Setup (CTS). For each camera pixel,
the CTS is equipped with two LEDs, one operated in pulsed mode to reproduce
signal and one in continuous mode to reproduce night-sky background.
In this contribution we will present the camera calibration strategy, from
the laboratory measurement to the on-site monitoring with emphasis on the
results obtained with the first camera prototype. In addition, key performances
such as charge resolution, time resolution and trigger efficiencies and their
degradation with increasing night-sky background level will be presented.
[3]
oai:arXiv.org:1907.08061 [pdf] - 1918999
Monte Carlo study of a single SST-1M prototype for the Cherenkov
Telescope Array
Jurysek, Jakub;
Samarai, Imen Al;
Alispach, Cyril;
Balbo, Matteo;
Barbano, Anastasia Maria;
Beshley, Vasyl;
Biland, Adrian;
Blazek, Jiri;
Błocki, Jacek;
Borkowski, Jerzy;
Bulik, Tomek;
Cadoux, Frank Raphael;
Chytka, Ladislav;
Coco, Victor;
De Angelis, Nicolas;
Della Volpe, Domenico;
Favre, Yannick;
Gieras, Tomasz;
Grudzińska, Mira;
Hamal, Petr;
Heller, Mathieu;
Hrabovsky, Miroslav;
Kasperek, Jerzy;
Koncewicz, Katarzyna;
Kotarba, Andrzej;
Lyard, Etienne;
Mach, Emil;
Mandat, Dusan;
Michal, Stanislav;
Michalowski, Jerzy;
Moderski, Rafal;
Montaruli, Teresa;
Nagai, Andrii;
Neise, Dominik;
Niemiec, Jacek;
Ekoume, Theodore Rodrigue Njoh;
Ostrowski, Michal;
Palatka, Miroslav;
Pasko, Pawel;
Pech, Miroslav;
Pilszyk, Bartłomiej;
Przybilski, Henry;
Rajda, Pawel;
Renier, Yves;
Rozwadowski, Paweł;
Schovanek, Petr;
Seweryn, K.;
Sliusar, Vitalii;
Smakulska, Dorota;
Sobczyńska, Dorota;
Stawarz, Łukasz;
Świerblewski, Jacek;
Świerk, Paweł;
Travnicek, Petr;
Pujadas, Isaac Troyano;
Walter, Roland;
Wiecek, Marek;
Zagdański, Aleksander;
Zietara, Krzystof
Submitted: 2019-07-18
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope
for the Cherenkov Telescope Array observatory and it has been extensively
tested in Krakow since 2017. In this contribution we present validation of the
Monte Carlo model of the prototype and expected performance in Krakow
conditions. We focus on gamma/hadron separation and mono reconstruction of
energy and gamma photon arrival direction using Machine learning methods.
[4]
oai:arXiv.org:1901.04351 [pdf] - 1818883
Penetrating particle ANalyzer (PAN)
Wu, X.;
Ambrosi, G.;
Azzarello, P.;
Bergmann, B.;
Bertucci, B.;
Cadoux, F.;
Campbell, M.;
Duranti, M.;
Ionica, M.;
Kole, M.;
Krucker, S.;
Maehlum, G.;
Meier, D.;
Paniccia, M.;
Pinsky, L.;
Plainaki, C.;
Pospisil, S.;
Stein, T.;
Thonet, P. A.;
Tomassetti, N.;
Tykhonov, A.
Submitted: 2019-01-14, last modified: 2019-01-21
PAN is a scientific instrument suitable for deep space and interplanetary
missions. It can precisely measure and monitor the flux, composition, and
direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep
space, over at least one full solar cycle (~11 years). The science program of
PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar
physics, space weather and space travel. PAN will fill an observation gap of
galactic cosmic rays in the GeV region, and provide precise information of the
spectrum, composition and emission time of energetic particle originated from
the Sun. The precise measurement and monitoring of the energetic particles is
also a unique contribution to space weather studies. PAN will map the flux and
composition of penetrating particles, which cannot be shielded effectively,
precisely and continuously, providing valuable input for the assessment of the
related health risk, and for the development of an adequate mitigation
strategy. PAN has the potential to become a standard on-board instrument for
deep space human travel.
PAN is based on the proven detection principle of a magnetic spectrometer,
but with novel layout and detection concept. It will adopt advanced particle
detection technologies and industrial processes optimized for deep space
application. The device will require limited mass (~20 kg) and power (~20 W)
budget. Dipole magnet sectors built from high field permanent magnet Halbach
arrays, instrumented in a modular fashion with high resolution silicon strip
detectors, allow to reach an energy resolution better than 10\% for nuclei from
H to Fe at 1 GeV/n.
[5]
oai:arXiv.org:1901.04207 [pdf] - 1857202
Detailed polarization measurements of the prompt emission of five
Gamma-Ray Bursts
Zhang, Shuang-Nan;
Kole, Merlin;
Bao, Tian-Wei;
Batsch, Tadeusz;
Bernasconi, Tancredi;
Cadoux, Franck;
Chai, Jun-Ying;
Dai, Zi-Gao;
Dong, Yong-Wei;
Gauvin, Neal;
Hajdas, Wojtek;
Lan, Mi-Xiang;
Li, Han-Cheng;
Li, Lu;
Li, Zheng-Heng;
Liu, Jiang-Tao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Produit, Nicolas;
Pohl, Martin;
Rybka, Dominik;
Shi, Hao-Li;
Song, Li-Ming;
Sun, Jian-Chao;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Rui-Jie;
Wang, Yuan-Hao;
Wen, Xing;
Wu, Bo-Bing;
Wu, Xin;
Wu, Xue-Feng;
Xiao, Hua-Lin;
Xiong, Shao-Lin;
Zhang, Lai-Yu;
Zhang, Li;
Zhang, Xiao-Feng;
Zhang, Yong-Jie;
Zwolinska, Anna
Submitted: 2019-01-14
Gamma-ray bursts are the strongest explosions in the Universe since the Big
Bang, believed to be produced either in forming black holes at the end of
massive star evolution or merging of compact objects. Spectral and timing
properties of gamma-ray bursts suggest that the observed bright gamma-rays are
produced in the most relativistic jets in the Universe; however, the physical
properties, especially the structure and magnetic topologies in the jets are
still not well known, despite several decades of studies. It is widely believed
that precise measurements of the polarization properties of gamma-ray bursts
should provide crucial information on the highly relativistic jets. As a result
there have been many reports of gamma-ray burst polarization measurements with
diverse results, see, however many such measurements suffered from substantial
uncertainties, mostly systematic. After the first successful measurements by
the GAP and COSI instruments, here we report a statistically meaningful sample
of precise polarization measurements, obtained with the dedicated gamma-ray
burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results
suggest that the gamma-ray emission is at most polarized at a level lower than
some popular models have predicted; although our results also show intrapulse
evolution of the polarization angle. This indicates that the low polarization
degrees could be due to an evolving polarization angle during a gamma-ray
burst.
[6]
oai:arXiv.org:1812.04020 [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan;
Santangelo, Andrea;
Feroci, Marco;
Xu, YuPeng;
Lu, FangJun;
Chen, Yong;
Feng, Hua;
Zhang, Shu;
Brandt, Søren;
Hernanz, Margarita;
Baldini, Luca;
Bozzo, Enrico;
Campana, Riccardo;
De Rosa, Alessandra;
Dong, YongWei;
Evangelista, Yuri;
Karas, Vladimir;
Meidinger, Norbert;
Meuris, Aline;
Nandra, Kirpal;
Pan, Teng;
Pareschi, Giovanni;
Orleanski, Piotr;
Huang, QiuShi;
Schanne, Stephane;
Sironi, Giorgia;
Spiga, Daniele;
Svoboda, Jiri;
Tagliaferri, Gianpiero;
Tenzer, Christoph;
Vacchi, Andrea;
Zane, Silvia;
Walton, Dave;
Wang, ZhanShan;
Winter, Berend;
Wu, Xin;
Zand, Jean J. M. in 't;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Barbera, Marco;
Basso, Stefano;
Bayer, Jörg;
Bellazzini, Ronaldo;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Cao, XueLei;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, TianXiang;
Chen, YuPeng;
Chevenez, Jerome;
Civitani, Marta;
Cui, Wei;
Cui, WeiWei;
Dauser, Thomas;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Doroshenko, Victor;
Dovciak, Michal;
Du, YuanYuan;
Ducci, Lorenzo;
Fan, QingMei;
Favre, Yannick;
Fuschino, Fabio;
Gálvez, José Luis;
Gao, Min;
Ge, MingYu;
Gevin, Olivier;
Grassi, Marco;
Gu, QuanYing;
Gu, YuDong;
Han, DaWei;
Hong, Bin;
Hu, Wei;
Ji, Long;
Jia, ShuMei;
Jiang, WeiChun;
Kennedy, Thomas;
Kreykenbohm, Ingo;
Kuvvetli, Irfan;
Labanti, Claudio;
Latronico, Luca;
Li, Gang;
Li, MaoShun;
Li, Xian;
Li, Wei;
Li, ZhengWei;
Limousin, Olivier;
Liu, HongWei;
Liu, XiaoJing;
Lu, Bo;
Luo, Tao;
Macera, Daniele;
Malcovati, Piero;
Martindale, Adrian;
Michalska, Malgorzata;
Meng, Bin;
Minuti, Massimo;
Morbidini, Alfredo;
Muleri, Fabio;
Paltani, Stephane;
Perinati, Emanuele;
Picciotto, Antonino;
Piemonte, Claudio;
Qu, JinLu;
Rachevski, Alexandre;
Rashevskaya, Irina;
Rodriguez, Jerome;
Schanz, Thomas;
Shen, ZhengXiang;
Sheng, LiZhi;
Song, JiangBo;
Song, LiMing;
Sgro, Carmelo;
Sun, Liang;
Tan, Ying;
Uttley, Phil;
Wang, Juan;
Wang, LangPing;
Wang, YuSa;
Watts, Anna L.;
Wen, XiangYang;
Wilms, Jörn;
Xiong, ShaoLin;
Yang, JiaWei;
Yang, Sheng;
Yang, YanJi;
Yu, Nian;
Zhang, WenDa;
Zampa, Gianluigi;
Zampa, Nicola;
Zdziarski, Andrzej A.;
Zhang, AiMei;
Zhang, ChengMo;
Zhang, Fan;
Zhang, Long;
Zhang, Tong;
Zhang, Yi;
Zhang, XiaoLi;
Zhang, ZiLiang;
Zhao, BaoSheng;
Zheng, ShiJie;
Zhou, YuPeng;
Zorzi, Nicola;
Zwart, J. Frans
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission -
eXTP. eXTP is a space science mission designed to study fundamental physics
under extreme conditions of density, gravity and magnetism. The mission aims at
determining the equation of state of matter at supra-nuclear density, measuring
effects of QED, and understanding the dynamics of matter in strong-field
gravity. In addition to investigating fundamental physics, eXTP will be a very
powerful observatory for astrophysics that will provide observations of
unprecedented quality on a variety of galactic and extragalactic objects. In
particular, its wide field monitoring capabilities will be highly instrumental
to detect the electro-magnetic counterparts of gravitational wave sources. The
paper provides a detailed description of: (1) the technological and technical
aspects, and the expected performance of the instruments of the scientific
payload; (2) the elements and functions of the mission, from the spacecraft to
the ground segment.
[7]
oai:arXiv.org:1807.11269 [pdf] - 1724303
The Large Area Detector onboard the eXTP mission
Feroci, Marco;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Argan, Andrea;
Barbera, Marco;
Bayer, Joerg;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Bozzo, Enrico;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, Tianxiang;
Cirrincione, Daniela;
De Rosa, Alessandra;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Evangelista, Yuri;
Fan, Qingmei;
Favre, Yannick;
Ficorella, Francesco;
Fuschino, Fabio;
Gevin, Olivier;
Grassi, Marco;
Hong, Bin;
Mao, Hanqi;
Karas, Vladimir;
Kennedy, Tom;
Labanti, Claudio;
Limousin, Olivier;
Cicero, Ugo Lo;
Lu, Fang-Jun;
Luo, Tao;
Malcovati, Piero;
Martindale, Adrian;
Meuris, Aline;
Michalska, Malgorzata;
Morbidini, Alfredo;
Muleri, Fabio;
Orleanski, Piotr;
Paltani, Stephane;
Pan, Teng;
Perinati, Emanuele;
Picciotto, Antonino;
Pohl, Martin;
Rashevskaia, Irina;
Santangelo, Andrea;
Schanne, Stephane;
Skup, Konrad;
Svoboda, Jiri;
Tenzer, Chris;
Vacchi, Andrea;
Walton, Dave;
Winter, Berend;
Wu, Xin;
Xu, Yupeng;
Zampa, Ganluigi;
Zampa, Nicola;
Zane, Silvia;
Zdziarski, Andrzej;
Zhang, Long;
Zhang, Shu;
Zhang, Shuang-Nan;
Zhang, Wenda;
Zhang, Xiaoli;
Zhou, Yupeng;
Zorzi, Nicola
Submitted: 2018-07-30
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project
of the Chinese Academy of Sciences (CAS) and China National Space
Administration (CNSA) currently performing an extended phase A study and
proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload
envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry
Focusing Array, Large Area Detector and Wide Field Monitor) offering
unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry
sensitivity. A large European consortium is contributing to the eXTP study and
it is expected to provide key hardware elements, including a Large Area
Detector (LAD). The LAD instrument for eXTP is based on the design originally
proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a
deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through
the technology of the large-area Silicon Drift Detectors - offering a spectral
resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators -
limiting the field of view to about 1 degree. In this paper we provide an
overview of the LAD instrument design, including new elements with respect to
the earlier LOFT configuration.
[8]
oai:arXiv.org:1806.10355 [pdf] - 1706640
In-flight performance of the DAMPE silicon tracker
Tykhonov, A.;
Ambrosi, G.;
Asfandiyarov, R.;
Azzarello, P.;
Bernardini, P.;
Bertucci, B.;
Bolognini, A.;
Cadoux, F.;
D'Amone, A.;
De Benedittis, A.;
De Mitri, I.;
Di Santo, M.;
Dong, Y. F.;
Duranti, M.;
D'Urso, D.;
Fan, R. R.;
Fusco, P.;
Gallo, V.;
Gao, M.;
Gargano, F.;
Garrappa, S.;
Gong, K.;
Ionica, M.;
La Marra, D.;
Loparco, F.;
Marsella, G.;
Mazziotta, M. N.;
Peng, W. X.;
Qiao, R.;
Salinas, M. M.;
Surdo, A.;
Vagelli, V.;
Vitillo, S.;
Wang, H. Y.;
Wang, J. Z.;
Wang, Z. M.;
Wu, D.;
Wu, X.;
Zhang, F.;
Zhang, J. Y.;
Zhao, H.;
Zimmer, S.
Submitted: 2018-06-27
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray
and gamma-ray detector, successfully launched in December 2015. It is designed
to probe astroparticle physics in the broad energy range from few GeV to 100
TeV. The scientific goals of DAMPE include the identification of possible
signatures of Dark Matter annihilation or decay, the study of the origin and
propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE
consists of four sub-detectors: a plastic scintillator strip detector, a
Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron
detector. The STK is composed of six double layers of single-sided silicon
micro-strip detectors interleaved with three layers of tungsten for photon
conversions into electron-positron pairs. The STK is a crucial component of
DAMPE, allowing to determine the direction of incoming photons, to reconstruct
tracks of cosmic rays and to estimate their absolute charge (Z). We present the
in-flight performance of the STK based on two years of in-flight DAMPE data,
which includes the noise behavior, signal response, thermal and mechanical
stability, alignment and position resolution.
[9]
oai:arXiv.org:1710.08918 [pdf] - 1724839
In-flight energy calibration of the space-borne Compton polarimeter
POLAR
Xiao, Hualin;
Hajdas, Wojtek;
Wu, Bobing;
Produit, Nicolas;
Sun, Jianchao;
Kole, Merlin;
Bao, Tianwei;
Bernasconi, Tancredi;
Batsch, Tadeusz;
Cadoux, Franck;
Chai, Junying;
Dong, Yongwei;
Egli, Ken;
Gauvin, Neal;
Kong, Minnan;
Kramert, Reinhold;
Kong, Siwei;
Li, Hancheng;
Li, Lu;
Li, Zhengheng;
Liu, Jiangtao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Rybka, Dominik K.;
Pohl, Martin;
Shi, Haoli;
Song, Liming;
Xiong, Shaolin;
Szabelski, Jacek;
Socha, Patryk;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Zhang, Laiyu;
Zhang, Ping;
Zhang, Shuangnan;
Zhang, Xiaofeng;
Zhang, Yongjie;
Zhao, Yi;
Zwolinska, Anna
Submitted: 2017-10-24, last modified: 2018-06-05
POLAR is a compact wide-field space-borne detector for precise measurements
of the linear polarisation of hard X-rays emitted by transient sources in the
energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of
plastic scintillator bars used as a detection material. The bars are grouped in
25 detector modules. The energy range sensitivity of POLAR is optimized to
match with the prompt emission photons from the gamma-ray bursts (GRBs).
Polarization measurements of the prompt emission would probe source geometries,
emission mechanisms and magnetic structures in GRB jets. The instrument can
also detect hard X-rays from solar flares and be used for precise measurement
of their polarisation. POLAR was launched into a low Earth orbit on-board the
Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in
polarisation measurements it is essential to assure both before and during the
flight a precise energy calibration. Such calibrations are performed with four
low activity $^{22}$Na radioactive sources placed inside the instrument. Energy
conversion factors are related to Compton edge positions from the collinear
annihilation photons from the sources. This paper presents main principles of
the in-flight calibration, describes studies of the method based on Monte Carlo
simulations and its laboratory verification and finally provides some
observation results based on the in-flight data analysis.
[10]
oai:arXiv.org:1805.07605 [pdf] - 1690419
In-Orbit Instrument Performance Study and Calibration for POLAR
Polarization Measurements
Li, Zhengheng;
Kole, Merlin;
Sun, Jianchao;
Song, Liming;
Produit, Nicolas;
Wu, Bobing;
Bao, Tianwei;
Bernasconi, Tancredi;
Cadoux, Franck;
Dong, Yongwei;
Feng, Minzi;
Gauvin, Neal;
Hajdas, Wojtek;
Li, Hancheng;
Li, Lu;
Liu, Xin;
Marcinkowski, Radoslaw;
Pohl, Martin;
Rybka, Dominik K.;
Shi, Haoli;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Xiong, Shaolin;
Zwolinska, Anna;
Zhang, Li;
Zhang, Laiyu;
Zhang, Shuangnan;
Zhang, Yongjie;
Zhao, Yi
Submitted: 2018-05-19, last modified: 2018-05-28
POLAR is a compact space-borne detector designed to perform reliable
measurements of the polarization for transient sources like Gamma-Ray Bursts in
the energy range 50-500keV. The instrument works based on the Compton
Scattering principle with the plastic scintillators as the main detection
material along with the multi-anode photomultiplier tube. POLAR has been
launched successfully onboard the Chinese space laboratory TG-2 on 15th
September, 2016. In order to reliably reconstruct the polarization information
a highly detailed understanding of the instrument is required for both data
analysis and Monte Carlo studies. For this purpose a full study of the in-orbit
performance was performed in order to obtain the instrument calibration
parameters such as noise, pedestal, gain nonlinearity of the electronics,
threshold, crosstalk and gain, as well as the effect of temperature on the
above parameters. Furthermore the relationship between gain and high voltage of
the multi-anode photomultiplier tube has been studied and the errors on all
measurement values are presented. Finally the typical systematic error on
polarization measurements of Gamma-Ray Bursts due to the measurement error of
the calibration parameters are estimated using Monte Carlo simulations.
[11]
oai:arXiv.org:1709.07191 [pdf] - 1588657
Design and construction of the POLAR detector
Produit, N.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Britvich, I.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
Kole, M.;
Kong, M. N.;
Kramert, R.;
Li, L.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Rutczynska, A.;
Shi, H. L.;
Socha, P.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Traseira, I.;
Xiao, H. L.;
Wang, R. J.;
Wen, X.;
Wu, B. B.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-09-21, last modified: 2017-09-28
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a
wide field of view, which covers almost half the sky. The instrument uses
Compton scattering of gamma rays on a plastic scintillator hodoscope to measure
the polarization of the incoming photons. The instrument has been successfully
launched on board of the Chinese space laboratory Tiangong~2 on September 15,
2016. The construction of the instrument components is described in this
article. Details are provided on problems encountered during the construction
phase and their solutions. Initial performance of the instrument in orbit is as
expected from ground tests and Monte Carlo simulation.
[12]
oai:arXiv.org:1709.04244 [pdf] - 1620692
Control Software for the SST-1M Small-Size Telescope prototype for the
Cherenkov Telescope Array
Sliusar, V.;
Walter, R.;
Alispach, C.;
Samarai, I. Al;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Coco, V.;
della Volpe, D.;
Favre, Y.;
Frankowski, A.;
Grudzińska, M.;
Heller, M.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Michałowski, J.;
Moderski, R.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ekoume, T. R. S. Njoh;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Rajda, P.;
Rafalski, J.;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Pujadas, I. Troyano;
Wiȩcek, M.;
Zagdański, A.;
Ziȩtara, K.
Submitted: 2017-09-13, last modified: 2017-09-14
The SST-1M is a 4-m Davies--Cotton atmospheric Cherenkov telescope optimized
to provide gamma-ray sensitivity above a few TeV. The SST-1M is proposed as
part of the Small-Size Telescope array for the Cherenkov Telescope Array (CTA),
the first prototype has already been deployed. The SST-1M control software of
all subsystems (active mirror control, drive system, safety system,
photo-detection plane, DigiCam, CCD cameras) and the whole telescope itself
(master controller) uses the standard software design proposed for all CTA
telescopes based on the ALMA Common Software (ACS) developed to control the
Atacama Large Millimeter Array (ALMA). Each subsystem is represented by a
separate ACS component, which handles the communication to and the operation of
the subsystem. Interfacing with the actual hardware is performed via the OPC UA
communication protocol, supported either natively by dedicated industrial
standard servers (PLCs) or separate service applications developed to wrap
lower level protocols (e.g. CAN bus, camera slow control) into OPC UA. Early
operations of the telescope without the camera were already carried out. The
camera is fully assembled and is capable to perform data acquisition using
artificial light source.
[13]
oai:arXiv.org:1709.03914 [pdf] - 1620686
Performance of a small size telescope (SST-1M) camera for gamma-ray
astronomy with the Cherenkov Telescope Array
Samarai, I. Al;
Alispach, C.;
Cadoux, F.;
Coco, V.;
della Volpe, D.;
Favre, Y.;
Heller, M.;
Montaruli, T.;
Nagai, A.;
Ekoume, T. R. S. Njoh;
Pujadas, I. Troyano;
Lyard, E.;
Neronov, A.;
Walter, R.;
Sliusar, V.;
Mach, E.;
Michałowski, J.;
Niemiec, J.;
Rafalski, J.;
Skowron, K.;
Stodulska, M.;
Stodulski, M.;
Bulik, T.;
Grudzińska, M.;
Jamrozy, M.;
Ostrowski, M.;
Stawarz, Ł.;
Zagdański, A.;
Ziȩtara, K.;
Paśko, P.;
Seweryn, K.;
Borkowski, J.;
Moderski, R.;
Kasperek, J.;
Rajda, P.;
Mandat, D.;
Pech, M.;
Schovanek, P.;
Travnicek, P.
Submitted: 2017-09-12
The foreseen implementations of the Small Size Telescopes (SST) in CTA will
provide unique insights into the highest energy gamma rays offering fundamental
means to discover and under- stand the sources populating the Galaxy and our
local neighborhood. Aiming at such a goal, the SST-1M is one of the three
different implementations that are being prototyped and tested for CTA. SST-1M
is a Davies-Cotton single mirror telescope equipped with a unique camera
technology based on SiPMs with demonstrated advantages over classical
photomultipliers in terms of duty-cycle. In this contribution, we describe the
telescope components, the camera, and the trigger and readout system. The
results of the commissioning of the camera using a dedicated test setup are
then presented. The performances of the camera first prototype in terms of
expected trigger rates and trigger efficiencies for different night-sky
background conditions are presented, and the camera response is compared to
end-to-end simulations.
[14]
oai:arXiv.org:1709.03920 [pdf] - 1620687
Development of a strategy for calibrating the novel SiPM camera of the
SST-1M telescope proposed for the Cherenkov Telescope Array
Samarai, I. Al;
Alispach, C.;
Cadoux, F.;
Coco, V.;
della Volpe, D.;
Favre, Y.;
Heller, M.;
Montaruli, T.;
Nagai, A.;
Ekoume, T. R. S. Njoh;
Pujadas, I. Troyano;
Lyard, E.;
Neronov, A.;
Walter, R.;
Sliusar, V.;
Mach, E.;
Michałowski, J.;
Niemiec, J.;
Rafalski, J.;
Skowron, K.;
Stodulska, M.;
Stodulski, M.;
Bulik, T.;
Grudzińska, M.;
Jamrozy, M.;
Ostrowski, M.;
Stawarz, Ł.;
Zagdański, A.;
Ziȩtara, K.;
Paśko, P.;
Seweryn, K.;
Borkowski, J.;
Moderski, R.;
Kasperek, J.;
Rajda, P.;
Mandat, D.;
Pech, M.;
Schovanek, P.;
Travnicek, P.
Submitted: 2017-09-12
CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the
southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with
9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the
requirements of the next generation ground based gamma-ray observatory CTA in
the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of
gamma-ray telescopes can achieve good performance even during high night sky
background conditions. Defining a fully automated calibration strategy of SiPM
cameras is of great importance for large scale production validation and online
calibration. The SST-1M sub-consortium developed a software compatible with CTA
pipeline software (CTApipe). The calibration of the SST-1M camera is based on
the Camera Test Setup (CTS), a set of LED boards mounted in front of the
camera. The CTS LEDs are operated in pulsed or continuous mode to emulate
signal and night sky background respectively. Continuous and pulsed light data
analysis allows us to extract single pixel calibration parameters to be used
during CTA operation.
[15]
oai:arXiv.org:1708.00664 [pdf] - 1586674
Instrument Performance and Simulation Verification of the POLAR Detector
Kole, M.;
Li, Z. H.;
Produit, N.;
Tymieniecka, T.;
Zhang, J.;
Zwolinska, A.;
Bao, T. W.;
Bernasconi, T.;
Cadoux, F.;
Feng, M. Z.;
Gauvin, N.;
Hajdas, W.;
Kong, S. W.;
Li, H. C.;
Li, L.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rybka, D.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zhao, Y.
Submitted: 2017-08-02
POLAR is a new satellite-born detector aiming to measure the polarization of
an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The
instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of
September 2016, is designed to measure the polarization of the hard X-ray flux
by measuring the distribution of the azimuthal scattering angles of the
incoming photons. A detailed understanding of the polarimeter and specifically
of the systematic effects induced by the instrument's non-uniformity are
required for this purpose. In order to study the instrument's response to
polarization, POLAR underwent a beam test at the European Synchrotron Radiation
Facility in France. In this paper both the beam test and the instrument
performance will be described. This is followed by an overview of the Monte
Carlo simulation tools developed for the instrument. Finally a comparison of
the measured and simulated instrument performance will be provided and the
instrument response to polarization will be presented.
[16]
oai:arXiv.org:1704.06173 [pdf] - 1567780
Calibration of the Space-borne Compton Polarimeter POLAR flight model
with 100% polarized X-ray beams
Xiao, H. L.;
Hajdas, W.;
Socha, P.;
Marcinkowski, R.;
Wu, B. B.;
Bao, T. W.;
Chai, J. Y.;
Dong, Y. W.;
Kong, M. N.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Xiong, S. L.;
Zhang, J.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Cadoux, F.;
Pohl, M.;
Wu, X.;
Batsch, T.;
Rybka, D.;
Rutczynska, A.;
Szabelski, J.;
Zwolinska, A.;
Gauvin, N.;
Produit, N.;
Bernasconi, T.
Submitted: 2017-04-20, last modified: 2017-04-24
POLAR is space-borne detector designed for a precise measurement of gamma-ray
polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50
keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$
40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we
performed a series of tests of the POLAR flight model with 100\% polarized
x-rays beams at the European Synchrotron Radiation Facility beam-line ID11
aming to study thresholds, crosstalk between channels and responses of POLAR
flight model to polarized X-ray beams. In this paper we present the data
analysis method and some analysis results. According the results, POLAR FM has
good polarimetric capabilities.
[17]
oai:arXiv.org:1703.04210 [pdf] - 1547762
Gain factor and parameter settings optimization of the new gamma-ray
burst polarimeter POLAR
Zhang, X. F.;
Hajdas, W.;
Xiao, H. L.;
Wen, X.;
Wu, B. B.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
He, J. J.;
Kole, M.;
Kong, M. N.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wu, X.;
Xiong, S. L.;
Xu, M.;
Zhang, L.;
Zhang, L. Y.;
Zhang, P.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-03-12, last modified: 2017-03-14
As a space-borne detector POLAR is designed to conduct hard X-ray
polarization measurements of gamma-ray bursts on the statistically significant
sample of events and with an unprecedented accuracy. During its development
phase a number of tests, calibrations runs and verification measurements were
carried out in order to validate instrument functionality and optimize
operational parameters. In this article we present results on gain optimization
togeter with verification data obtained in the course of broad laboratory and
environmental tests. In particular we focus on exposures to the $^{137}$Cs
radioactive source and determination of the gain dependence on the high voltage
for all 1600 detection channels of the polarimeter. Performance of the
instrument is described in detail with respect to the dynamic range, energy
resolution and temperature dependence. Gain optimization algorithms and
response non-uniformity studies are also broadly discussed. Results presented
below constitute important parts for development of the POLAR calibration and
operation database.
[18]
oai:arXiv.org:1612.04098 [pdf] - 1533322
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB
Polarimeter
Kole, M.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
He, J. J.;
Kong, M. N.;
Kong, S. W.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. J.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Xiong, S. L.;
Xu, H. H.;
Xu, M.;
Zhang, J.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2016-12-13
Gamma-ray polarimetry is a new powerful tool to study the processes
responsible for the emission from astrophysical sources and the environments in
which this emission takes place. Few successful polarimetric measurements have
however been performed thus far in the gamma-ray energy band due to the
difficulties involved. POLAR is a dedicated polarimeter designed to perform
high precision measurements of the polarization of the emission from gamma-ray
burst in the 50-500 keV energy range. This new polarimeter is expected to
detect approximately 50 gamma-ray bursts per year while performing high
precision polarization measurements on approximately 10 bursts per year. The
instrument was launched into lower earth orbit as part of the second Chinese
space lab, the Tiangong-2, on September 15th 2016 and has been taking data
successfully since being switched on one week after. The instrument uses a
segmented scintillator array consisting of 1600 plastic scintillator bars, read
out by 25 flat-panel multi-anode photomultipliers, to measure the Compton
scattering angles of incoming photons. The small segmentation and relatively
large uniform effective area allow the instrument to measure the polarization
of a large number of transient events, such as gamma-ray bursts, with an
unprecedented precision during its two year life-time. The final flight model
underwent detailed calibration prior to launch as well as intensive space
qualification tests, a summary of which will be presented in this paper. The
instrument design will be discussed first followed by an overview of the
on-ground tests, finally the in-orbit behavior as measured during the first
weeks of the mission will be presented.
[20]
oai:arXiv.org:1610.01867 [pdf] - 1580349
The Single Mirror Small Sized Telescope For The Cherenkov Telescope
Array
Heller, M.;
Schioppa, E. jr;
Porcelli, A.;
Pujadas, I. Troyano;
Zietara, K.;
della Volpe, D.;
Montaruli, T.;
Cadoux, F.;
Favre, Y.;
Aguilar, J. A.;
Christov, A.;
Prandini, E.;
Rajda, P.;
Rameez, M.;
Bilnik, W.;
Blocki, J.;
Bogacz, L.;
Borkowski, J.;
Bulik, T.;
Frankowski, A.;
Grudzinska, M.;
Idzkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszalek, A.;
Miranda, L. D. Medina;
Michalowski, J.;
Moderski, R.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Pasko, P.;
Pech, M.;
Schovanek, P.;
Seweryn, K.;
Sliusar, V.;
Skowron, K.;
Stawarz, L.;
Stodulska, M.;
Stodulski, M.;
Walter, R.;
Wiecek, M.;
Zagdanski, A.;
consortium, the CTA
Submitted: 2016-10-06
The Small Size Telescope with Single Mirror (SST-1M) is one of the proposed
types of Small Size Telescopes (SST) for the Cherenkov Telescope Array (CTA).
About 70 SST telescopes will be part the CTA southern array which will also
include Medium Sized Telescopes (MST) in its threshold configuration. Optimized
for the detection of gamma rays in the energy range from 5 TeV to 300 TeV, the
SST-1M uses a Davies-Cotton optics with a 4 m dish diameter with a field of
view of 9 degrees. The Cherenkov light resulting from the interaction of the
gamma-rays in the atmosphere is focused onto a 88 cm side-to-side hexagonal
photo-detection plane. The latter is composed of 1296 hollow light guides
coupled to large area hexagonal silicon photomultipliers (SiPM). The SiPM
readout is fully digital readout as for the trigger system. The compact and
lightweight design of the SST-1M camera offers very high performance ideal for
gamma-ray observation requirement. In this contribution, the concept, design,
performance and status of the first telescope prototype are presented.
[21]
oai:arXiv.org:1607.03412 [pdf] - 1542692
An innovative silicon photomultiplier digitizing camera for gamma-ray
astronomy
Heller, Matthieu;
Schioppa, Enrico Junior;
Porcelli, Alessio;
Pujadas, Isaac Troyano;
Zietara, Krzysztof;
Della Volpe, Domenico;
Montaruli, Teresa;
Cadoux, Franck;
Favre, Yannick;
Sanchez, Juan Antonio Aguilar;
Christov, Asen;
Prandini, Elisa;
Rajda, Pawel;
Rameez, Mohamed;
Blinik, Woijciech;
Blocki, Jacek;
Bogacz, Leszek;
Borkowski, Jurek;
Bulik, Tomasz;
Frankowski, Adam;
Grudzinska, Mira;
Idzkowski, Bartosz;
Jamrozy, Mateusz;
Janiak, Mateusz;
Kasperek, Jerzy;
Lalik, Krzysztof;
Lyard, Etienne;
Mach, Emil;
Mandat, Dusan;
Marszalek, Adrian;
Miranda, Luis David Medina;
Michalowski, Jerzy;
Neronov, Andrii;
Niemiec, Jacek;
Ostrowski, Michal;
Pasko, Pawel;
Pech, Miroslav;
Schovanek, Petr;
Seweryn, Karol;
Sliusar, Vitalii;
Skowron, Krzysztof;
Stawarz, Lukasz;
Stodulska, Magdalena;
Stodulski, Marek;
Walter, Roland;
Wiecek, Marek;
Zagdanski, Aleksander
Submitted: 2016-07-12
The single-mirror small-size telescope (SST-1M) is one of the three proposed
designs for the small-size telescopes (SSTs) of the Cherenkov Telescope Array
(CTA) project. The SST-1M will be equipped with a 4 m-diameter segmented mirror
dish and an innovative fully digital camera based on silicon photo-multipliers
(SiPMs). Since the SST sub-array will consist of up to 70 telescopes, the
challenge is not only to build a telescope with excellent performance, but also
to design it so that its components can be commissioned, assembled and tested
by industry. In this paper we review the basic steps that led to the design
concepts for the SST-1M camera and the ongoing realization of the first
prototype, with focus on the innovative solutions adopted for the photodetector
plane and the readout and trigger parts of the camera. In addition, we report
on results of laboratory measurements on real scale elements that validate the
camera design and show that it is capable of matching the CTA requirements of
operating up to high-moon-light background conditions.
[22]
oai:arXiv.org:1509.01824 [pdf] - 1938100
Prototype of the SST-1M Telescope Structure for the Cherenkov Telescope
Array
Niemiec, J.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Borkowski, J.;
Bulik, T .;
Cadoux, F.;
Christov, A.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Montaruli, T.;
Neronov, A.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Prandini, E.;
Rajda, P.;
Rameez, M.;
Schioppa, E. jr.;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Pujadas, I. Troyano;
Toscano, S.;
Walter, R.;
Wiȩcek, M.;
Zagdański, A.;
Ziȩtara, K.;
Żychowski, P.
Submitted: 2015-09-06
A single-mirror small-size (SST-1M) Davies-Cotton telescope with a dish
diameter of 4 m has been built by a consortium of Polish and Swiss institutions
as a prototype for one of the proposed small-size telescopes for the southern
observatory of the Cherenkov Telescope Array (CTA). The design represents a
very simple, reliable, and cheap solution. The mechanical structure prototype
with its drive system is now being tested at the Institute of Nuclear Physics
PAS in Krakow. Here we present the design of the prototype and results of the
performance tests of the structure and the drive and control system.
[23]
oai:arXiv.org:1509.00266 [pdf] - 1938092
Using muon rings for the optical throughput calibration of the SST-1M
prototype for the Cherenkov Telescope Array
Toscano, S.;
Prandini, E.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Rameez, M.;
Rajda, P.;
Schioppa, E. jr.;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Pujadas, I. Troyano;
Walter, R.;
Więcek, M.;
Zagdański, A.;
Ziętara, K.;
Żychowski, P.
Submitted: 2015-09-01
Imaging Atmospheric Cherenkov Telescopes (IACTs) are ground-based instruments
devoted to the study of very high energy gamma-rays coming from space. The
detection technique consists of observing images created by the Cherenkov light
emitted when gamma rays, or more generally cosmic rays, propagate through the
atmosphere. While in the case of protons or gamma-rays the images present a
filled and more or less elongated shape, energetic muons penetrating the
atmosphere are visualised as characteristic circular rings or arcs. A
relatively simple analysis of the ring images allows the reconstruction of all
the relevant parameters of the detected muons, such as the energy, the impact
parameter, and the incoming direction, with the final aim to use them to
calibrate the total optical throughput of the given IACT telescope. We present
the results of preliminary studies on the use of images created by muons as
optical throughput calibrators of the single mirror small size telescope
prototype SST-1M proposed for the Cherenkov Telescope Array.
[24]
oai:arXiv.org:1508.07472 [pdf] - 1941990
Software design for the control system for Small-Size Telescopes with
single-mirror of the Cherenkov Telescope Array
Porcelli, A.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Borkowski, J.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Rameez, M.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Prandini, E.;
Rajda, P.;
Schioppa, E. jr;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Pujadas, I. Troyano;
Toscano, S.;
Walter, R.;
Wiȩcek, M.;
Zagdański, A.;
Ziȩtara, K.;
Zychowski, P.
Submitted: 2015-08-29
The Small-Size Telescope with single-mirror (SST-1M) is a 4 m Davies-Cotton
telescope and is among the proposed telescope designs for the Cherenkov
Telescope Array (CTA). It is conceived to provide the high-energy ($>$ few TeV)
coverage. The SST-1M contains proven technology for the telescope structure and
innovative electronics and photosensors for the camera. Its design is meant to
be simple, low-budget and easy-to-build industrially.
Each device subsystem of an SST-1M telescope is made visible to CTA through a
dedicated industrial standard server. The software is being developed in
collaboration with the CTA Medium-Size Telescopes to ensure compatibility and
uniformity of the array control. Early operations of the SST-1M prototype will
be performed with a subset of the CTA central array control system based on the
Alma Common Software (ACS). The triggered event data are time stamped,
formatted and finally transmitted to the CTA data acquisition.
The software system developed to control the devices of an SST-1M telescope
is described, as well as the interface between the telescope abstraction to the
CTA central control and the data acquisition system.
[25]
oai:arXiv.org:1508.06795 [pdf] - 1938078
Development of the optical system for the SST-1M telescope of the
Cherenkov Telescope Array observatory
Seweryn, K.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Chruślińska, M.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Prandini, E.;
Pueschel, E.;
Rajda, P.;
Rameez, M.;
Rozwadowski, P.;
Schioppa, E. jr;
Schovanek, P.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Toscano, S.;
Pujadas, I. Troyano;
Walter, R.;
Wiȩcek, M.;
Zagdański, A.;
Ziȩtara, K.;
Żychowski, P.;
Barciński, T.;
Karczewski, M.;
Kukliński, J. Nicolau;
Płatos, Ł.;
Rataj, M.;
Wawer, P.;
Wawrzaszek, R.
Submitted: 2015-08-27
The prototype of a Davies-Cotton small size telescope (SST-1M) has been
designed and developed by a consortium of Polish and Swiss institutions and
proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose
of the optical system is to focus the Cherenkov light emitted by extensive air
showers in the atmosphere onto the focal plane detectors. The main component of
the system is a dish consisting of 18 hexagonal mirrors with a total effective
collection area of 6.47 m2 (including the shadowing and estimated mirror
reflectivity). Such a solution was chosen taking into account the analysis of
the Cherenkov light propagation and based on optical simulations. The proper
curvature and stability of the dish is ensured by the mirror alignment system
and the isostatic interface to the telescope structure. Here we present the
design of the optical subsystem together with the performance measurements of
its components.
[26]
oai:arXiv.org:1508.06397 [pdf] - 1938071
Camera calibration strategy of the SST-1M prototype of the Cherenokov
Telescope Array
Prandini, E.;
Heller, M.;
Lyard, E.;
Schioppa, E. jr.;
Neronov, A.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Montaruli, T.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Rameez, M.;
Rajda, P.;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Toscano, S.;
Pujadas, I. Troyano;
Walter, R.;
Więcek, M.;
Zagdański, A.;
Ziętara, K.;
Żychowski, P.
Submitted: 2015-08-26
The SST-1M telescope is one of the prototypes under construction proposed to
be part of the future Cherenkov Telescope Array. It uses a standard
Davis-Cotton design for the optics and telescope structure, with a dish
diameter of 4 meters and a large field-of-view of 9 degrees.
The innovative camera design is composed of a photo-detection plane with 1296
pixels including entrance window, light concentrators, Silicon Photomultipliers
(SiPMs), and pre-amplifier stages together with a fully digital readout and
trigger electronics, DigiCam.
In this contribution we give a general description of the analysis chain
designed for the SST-1M prototype. In particular we focus on the calibration
strategy used to convert the SiPM signals registered by DigiCam to the
quantities needed for Cherenkov image analysis. The calibration is based on an
online feedback system to stabilize the gain of the SiPMs, as well as dedicated
events (dark count, pedestal, and light flasher events) to be taken during the
normal operation of the prototype.
[27]
oai:arXiv.org:1508.06459 [pdf] - 1938074
Performance of the SST-1M telescope for the Cherenkov Telescope Array
observatory
Moderski, R.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Chruślińska, M.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Prandini, E.;
Pueschel, E.;
Rajda, P.;
Rameez, M.;
Rozwadowski, P.;
Schioppa, E. jr;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Toscano, S.;
Pujadas, I. Troyano;
Walter, R.;
Wiȩcek, M.;
Zagdański, A.;
Ziȩtara, K.;
Żychowski, P.
Submitted: 2015-08-26
The single mirror small-size telescope (SST-1M) is one of the telescope
projects being proposed for the Cherenkov Telescope Array observatory by a
sub-consortium of Polish and Swiss institutions. The SST-1M prototype structure
is currently being constructed at the Institute of Nuclear Physics in Cracow,
Poland, while the camera will be assembled at the University of Geneva,
Switzerland. This prototype enables measurements of parameters having a
decisive influence on the telescope performance. We present results of
numerical simulations of the SST-1M performance based on such measurements. The
telescope effective area, the expected trigger rates and the optical point
spread function are calculated.
[28]
oai:arXiv.org:1508.06453 [pdf] - 1266989
The SST-1M camera for the Cherenkov Telescope Array
Schioppa, E. J.;
Cadoux, F.;
Christov, A.;
della Volpe, D.;
Favre, Y.;
Heller, M.;
Montaruli, T.;
Porcelli, A.;
Rameez, M.;
Pujadas, I. Troyano;
Bilnik, W.;
Blocki, J.;
Bogacz, L.;
Bulik, T.;
Curylo, M.;
Dyrda, M.;
Frankowski, A.;
Grudniki, L.;
Grudzinska, M.;
Idzkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszalek, A.;
Michaowski, J.;
Moderski, R.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Pasko, P.;
Pech, M.;
Prandini, E.;
Rajda, P.;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowinski, M.;
Stawarz, L.;
Stodulska, M.;
Stodulski, M.;
Toscano, S.;
Walter, R.;
Wiecek, M.;
Zagdanski, A.;
Zietara, K.;
Zychowski, P.
Submitted: 2015-08-26
The prototype camera of the single-mirror Small Size Telescopes (SST-1M)
proposed for the Cherenkov Telescope Array (CTA) project has been designed to
be very compact and to deliver high performance over thirty years of operation.
The camera is composed of an hexagonal photo-detection plane made of custom
designed large area hexagonal silicon photomultipliers and a high throughput,
highly configurable, fully digital readout and trigger system (DigiCam). The
camera will be installed on the telescope structure at the H.
Niewodnicza{\'n}ski institute of Nuclear Physics in Krakow in fall 2015. In
this contribution, we review the steps that led to the development of the
innovative photo-detection plane and readout electronics, and we describe the
test and calibration strategy adopted.
[29]
oai:arXiv.org:1508.06082 [pdf] - 1265844
DigiCam - Fully Digital Compact Read-out and Trigger Electronics for the
SST-1M Telescope proposed for the Cherenkov Telescope Array
Rajda, P.;
Ziętara, K.;
Bilnik, W.;
Błocki, J.;
Bogacz, L.;
Bulik, T.;
Cadoux, F.;
Christov, A.;
Curyło, M.;
della Volpe, D.;
Dyrda, M.;
Favre, Y.;
Frankowski, A.;
Grudnik, Ł.;
Grudzińska, M.;
Heller, M.;
Idźkowski, B.;
Jamrozy, M.;
Janiak, M.;
Kasperek, J.;
Lalik, K.;
Lyard, E.;
Mach, E.;
Mandat, D.;
Marszałek, A.;
Michałowski, J.;
Moderski, R.;
Rameez, M.;
Montaruli, T.;
Neronov, A.;
Niemiec, J.;
Ostrowski, M.;
Paśko, P.;
Pech, M.;
Porcelli, A.;
Prandini, E.;
Schioppa, E. jr;
Schovanek, P.;
Seweryn, K.;
Skowron, K.;
Sliusar, V.;
Sowiński, M.;
Stawarz, Ł.;
Stodulska, M.;
Stodulski, M.;
Toscano, S.;
Pujadas, I. Troyano;
Walter, R.;
Więcek, M.;
Zagdański, A.;
Żychowski, P.
Submitted: 2015-08-25
The SST-1M is one of three prototype small-sized telescope designs proposed
for the Cherenkov Telescope Array, and is built by a consortium of Polish and
Swiss institutions. The SST-1M will operate with DigiCam - an innovative,
compact camera with fully digital read-out and trigger electronics. A high
level of integration will be achieved by massively deploying state-of-the-art
multi-gigabit transmission channels, beginning from the ADC flash converters,
through the internal data and trigger signals transmission over backplanes and
cables, to the camera's server link. Such an approach makes it possible to
design the camera to fit the size and weight requirements of the SST-1M
exactly, and provide low power consumption, high reliability and long lifetime.
The structure of the digital electronics will be presented, along with main
physical building blocks and the internal architecture of FPGA functional
subsystems.
[30]
oai:arXiv.org:1503.07682 [pdf] - 1043181
The effect of the displacement damage on the Charge Collection
Efficiency in Silicon Drift Detectors for the LOFT satellite
Del Monte, E.;
Evangelista, Y.;
Bozzo, E.;
Cadoux, F.;
Rachevski, A.;
Zampa, G.;
Zampa, N.;
Feroci, M.;
Pohl, M.;
Vacchi, A.
Submitted: 2015-03-26
The technology of Silicon Drift Detectors (SDDs) has been selected for the
two instruments aboard the Large Observatory For X-ray Timing (LOFT) space
mission. LOFT underwent a three year long assessment phase as candidate for the
M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science
plan of the European Space Agency. During the LOFT assessment phase, we studied
the displacement damage produced in the SDDs by the protons trapped in the
Earth's magnetosphere. In a previous paper we discussed the effects of the Non
Ionising Energy Losses from protons on the SDD leakage current. In this paper
we report the measurement of the variation of Charge Collection Efficiency
produced by displacement damage caused by protons and the comparison with the
expected damage in orbit.
[31]
oai:arXiv.org:1408.6526 [pdf] - 864022
The Large Observatory For x-ray Timing
Feroci, M.;
Herder, J. W. den;
Bozzo, E.;
Barret, D.;
Brandt, S.;
Hernanz, M.;
van der Klis, M.;
Pohl, M.;
Santangelo, A.;
Stella, L.;
Watts, A.;
Wilms, J.;
Zane, S.;
Ahangarianabhari, M.;
Albertus, C.;
Alford, M.;
Alpar, A.;
Altamirano, D.;
Alvarez, L.;
Amati, L.;
Amoros, C.;
Andersson, N.;
Antonelli, A.;
Argan, A.;
Artigue, R.;
Artigues, B.;
Atteia, J. -L.;
Azzarello, P.;
Bakala, P.;
Baldazzi, G.;
Balman, S.;
Barbera, M.;
van Baren, C.;
Bhattacharyya, S.;
Baykal, A.;
Belloni, T.;
Bernardini, F.;
Bertuccio, G.;
Bianchi, S.;
Bianchini, A.;
Binko, P.;
Blay, P.;
Bocchino, F.;
Bodin, P.;
Bombaci, I.;
Bidaud, J. -M. Bonnet;
Boutloukos, S.;
Bradley, L.;
Braga, J.;
Brown, E.;
Bucciantini, N.;
Burderi, L.;
Burgay, M.;
Bursa, M.;
Budtz-Jørgensen, C.;
Cackett, E.;
Cadoux, F. R.;
Cais, P.;
Caliandro, G. A.;
Campana, R.;
Campana, S.;
Capitanio, F.;
Casares, J.;
Casella, P.;
Castro-Tirado, A. J.;
Cavazzuti, E.;
Cerda-Duran, P.;
Chakrabarty, D.;
Château, F.;
Chenevez, J.;
Coker, J.;
Cole, R.;
Collura, A.;
Cornelisse, R.;
Courvoisier, T.;
Cros, A.;
Cumming, A.;
Cusumano, G.;
D'Aì, A.;
D'Elia, V.;
Del Monte, E.;
De Luca, A.;
De Martino, D.;
Dercksen, J. P. C.;
De Pasquale, M.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
Diebold, S.;
Di Salvo, T.;
Donnarumma, I.;
Drago, A.;
Durant, M.;
Emmanoulopoulos, D.;
Erkut, M. H.;
Esposito, P.;
Evangelista, Y.;
Fabian, A.;
Falanga, M.;
Favre, Y.;
Feldman, C.;
Ferrari, V.;
Ferrigno, C.;
Finger, M.;
Finger, M. H.;
Fraser, G. W.;
Frericks, M.;
Fuschino, F.;
Gabler, M.;
Galloway, D. K.;
Sanchez, J. L. Galvez;
Garcia-Berro, E.;
Gendre, B.;
Gezari, S.;
Giles, A. B.;
Gilfanov, M.;
Giommi, P.;
Giovannini, G.;
Giroletti, M.;
Gogus, E.;
Goldwurm, A.;
Goluchová, K.;
Götz, D.;
Gouiffes, C.;
Grassi, M.;
Groot, P.;
Gschwender, M.;
Gualtieri, L.;
Guidorzi, C.;
Guy, L.;
Haas, D.;
Haensel, P.;
Hailey, M.;
Hansen, F.;
Hartmann, D. H.;
Haswell, C. A.;
Hebeler, K.;
Heger, A.;
Hermsen, W.;
Homan, J.;
Hornstrup, A.;
Hudec, R.;
Huovelin, J.;
Ingram, A.;
Zand, J. J. M. in't;
Israel, G.;
Iwasawa, K.;
Izzo, L.;
Jacobs, H. M.;
Jetter, F.;
Johannsen, T.;
Jacobs, H. M.;
Jonker, P.;
Josè, J.;
Kaaret, P.;
Kanbach, G.;
Karas, V.;
Karelin, D.;
Kataria, D.;
Keek, L.;
Kennedy, T.;
Klochkov, D.;
Kluzniak, W.;
Kokkotas, K.;
Korpela, S.;
Kouveliotou, C.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kuvvetli, I.;
Labanti, C.;
Lai, D.;
Lamb, F. K.;
Laubert, P. P.;
Lebrun, F.;
Lin, D.;
Linder, D.;
Lodato, G.;
Longo, F.;
Lund, N.;
Maccarone, T. J.;
Macera, D.;
Maestre, S.;
Mahmoodifar, S.;
Maier, D.;
Malcovati, P.;
Mandel, I.;
Mangano, V.;
Manousakis, A.;
Marisaldi, M.;
Markowitz, A.;
Martindale, A.;
Matt, G.;
McHardy, I. M.;
Melatos, A.;
Mendez, M.;
Mereghetti, S.;
Michalska, M.;
Migliari, S.;
Mignani, R.;
Miller, M. C.;
Miller, J. M.;
Mineo, T.;
Miniutti, G.;
Morsink, S.;
Motch, C.;
Motta, S.;
Mouchet, M.;
Mouret, G.;
Mulačová, J.;
Muleri, F.;
Muñoz-Darias, T.;
Negueruela, I.;
Neilsen, J.;
Norton, A. J.;
Nowak, M.;
O'Brien, P.;
Olsen, P. E. H.;
Orienti, M.;
Orio, M.;
Orlandini, M.;
Orleanski, P.;
Osborne, J. P.;
Osten, R.;
Ozel, F.;
Pacciani, L.;
Paolillo, M.;
Papitto, A.;
Paredes, J. M.;
Patruno, A.;
Paul, B.;
Perinati, E.;
Pellizzoni, A.;
Penacchioni, A. V.;
Perez, M. A.;
Petracek, V.;
Pittori, C.;
Pons, J.;
Portell, J.;
Possenti, A.;
Poutanen, J.;
Prakash, M.;
Provost, P. Le;
Psaltis, D.;
Rambaud, D.;
Ramon, P.;
Ramsay, G.;
Rapisarda, M.;
Rachevski, A.;
Rashevskaya, I.;
Ray, P. S.;
Rea, N.;
Reddy, S.;
Reig, P.;
Aranda, M. Reina;
Remillard, R.;
Reynolds, C.;
Rezzolla, L.;
Ribo, M.;
de la Rie, R.;
Riggio, A.;
Rios, A.;
Gil, P. Rodríguez-;
Rodriguez, J.;
Rohlfs, R.;
Romano, P.;
Rossi, E. M. R.;
Rozanska, A.;
Rousseau, A.;
Ryde, F.;
Sabau-Graziati, L.;
Sala, G.;
Salvaterra, R.;
Sanna, A.;
Sandberg, J.;
Scaringi, S.;
Schanne, S.;
Schee, J.;
Schmid, C.;
Shore, S.;
Schneider, R.;
Schwenk, A.;
Schwope, A. D.;
Seyler, J. -Y.;
Shearer, A.;
Smith, A.;
Smith, D. M.;
Smith, P. J.;
Sochora, V.;
Soffitta, P.;
Soleri, P.;
Spencer, A.;
Stappers, B.;
Steiner, A. W.;
Stergioulas, N.;
Stratta, G.;
Strohmayer, T. E.;
Stuchlik, Z.;
Suchy, S.;
Sulemainov, V.;
Takahashi, T.;
Tamburini, F.;
Tauris, T.;
Tenzer, C.;
Tolos, L.;
Tombesi, F.;
Tomsick, J.;
Torok, G.;
Torrejon, J. M.;
Torres, D. F.;
Tramacere, A.;
Trois, A.;
Turolla, R.;
Turriziani, S.;
Uter, P.;
Uttley, P.;
Vacchi, A.;
Varniere, P.;
Vaughan, S.;
Vercellone, S.;
Vrba, V.;
Walton, D.;
Watanabe, S.;
Wawrzaszek, R.;
Webb, N.;
Weinberg, N.;
Wende, H.;
Wheatley, P.;
Wijers, R.;
Wijnands, R.;
Wille, M.;
Wilson-Hodge, C. A.;
Winter, B.;
Wood, K.;
Zampa, G.;
Zampa, N.;
Zampieri, L.;
Zdunik, L.;
Zdziarski, A.;
Zhang, B.;
Zwart, F.;
Ayre, M.;
Boenke, T.;
van Damme, C. Corral;
Kuulkers, E.;
Lumb, D.
Submitted: 2014-08-27, last modified: 2014-08-29
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3
Cosmic Vision framework and participated in the final down-selection for a
launch slot in 2022-2024. Thanks to the unprecedented combination of effective
area and spectral resolution of its main instrument, LOFT will study the
behaviour of matter under extreme conditions, such as the strong gravitational
field in the innermost regions of accretion flows close to black holes and
neutron stars, and the supra-nuclear densities in the interior of neutron
stars. The science payload is based on a Large Area Detector (LAD, 10 m 2
effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of
view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1
arcmin source location accuracy, 300 eV spectral resolution). The WFM is
equipped with an on-board system for bright events (e.g. GRB) localization. The
trigger time and position of these events are broadcast to the ground within 30
s from discovery. In this paper we present the status of the mission at the end
of its Phase A study.
[32]
oai:arXiv.org:1408.6538 [pdf] - 864030
Optimisation of the design for the LOFT Large Area Detector Module
Walton, D.;
Winter, B.;
Zane, S.;
Kennedy, T.;
Coker, A. J.;
Feroci, M.;
Herder, J. -W. Den;
Argan, A.;
Azzarello, P.;
Barret, D.;
Bradley, L.;
Cadoux, F.;
Cros, A.;
Evangelista, Y.;
Favre, Y.;
Fraser, G.;
Hailey, M. R.;
Hunt, T.;
Martindale, A.;
Muleri, F.;
Pacciani, L.;
Pohl, M.;
Smith, P.;
Santangelo, A.;
Suchy, S.;
Tenzer, C.;
Zampa, G.;
Zampa, N.
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is an X-ray timing observatory
that, with four other candidates, was considered by ESA as an M3 mission (with
launch in 2022-2024) and has been studied during an extensive assessment phase.
Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class
instrument operating in the 2-30 keV range, which is designed to perform X-ray
timing of compact objects with unprecedented resolution down to millisecond
time scales. Although LOFT was not downselected for launch, during the
assessment most of the trade-offs have been closed, leading to a robust and
well documented design that will be reproposed in future ESA calls. The
building block of the LAD instrument is the Module, and in this paper we
summarize the rationale for the module concept, the characteristics of the
module and the trade-offs/optimisations which have led to the current design.
[33]
oai:arXiv.org:1408.6539 [pdf] - 864031
The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
Zane, S.;
Walton, D.;
Kennedy, T.;
Feroci, M.;
Herder, J. -W. Den;
Ahangarianabhari, M.;
Argan, A.;
Azzarello, P.;
Baldazzi, G.;
Barbera, M.;
Barret, D.;
Bertuccio, G.;
Bodin, P.;
Bozzo, E.;
Bradley, L.;
Cadoux, F.;
Cais, P.;
Campana, R.;
Coker, J.;
Cros, A.;
Del Monte, E.;
De Rosa, A.;
Di Cosimo, S.;
Donnarumma, I.;
Evangelista, Y.;
Favre, Y.;
Feldman, C.;
Fraser, G.;
Fuschino, F.;
Grassi, M.;
Hailey, M. R.;
Hudec, R.;
Labanti, C.;
Macera, D.;
Malcovati, P.;
Marisaldi, M.;
Martindale, A.;
Mineo, T.;
Muleri, F.;
Nowak, M.;
Orlandini, M.;
Pacciani, L.;
Perinati, E.;
Petracek, V.;
Pohl, M.;
Rachevski, A.;
Smith, P.;
Santangelo, A.;
Seyler, J. -Y.;
Schmid, C.;
Soffitta, P.;
Suchy, S.;
Tenzer, C.;
Uttley, P.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Wilms, J.;
Winter, B.
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is one of the five candidates that
were considered by ESA as an M3 mission (with launch in 2022-2024) and has been
studied during an extensive assessment phase. It is specifically designed to
perform fast X-ray timing and probe the status of the matter near black holes
and neutron stars. Its pointed instrument is the Large Area Detector (LAD), a
10 m 2 -class instrument operating in the 2-30keV range, which holds the
capability to revolutionise studies of variability from X-ray sources on the
millisecond time scales. The LAD instrument has now completed the assessment
phase but was not down-selected for launch. However, during the assessment,
most of the trade-offs have been closed leading to a robust and well documented
design that will be re- proposed in future ESA calls. In this talk, we will
summarize the characteristics of the LAD design and give an overview of the
expectations for the instrument capabilities.
[34]
oai:arXiv.org:1404.2734 [pdf] - 1937959
Design, optimization and characterization of the light concentrators of
the single-mirror small size telescopes of the Cherenkov Telescope Array
Submitted: 2014-04-10
The focal-plane camera of $\gamma$-ray telescopes frequently uses light
concentrators in front of light sensors. The purpose of these concentrators is
to increase the effective area of the camera as well as to reduce the stray
light coming at large incident angles. These light concentrators are usually
based on the Winston cone design. In this contribution we present the design of
an hexagonal hollow light concentrator with a lateral profile optimized using a
cubic B\'ezier function to achieve a higher collection efficiency in the
angular region of interest. The design presented here is optimized for a
Davies-Cotton telescope with primary mirror of about 4 meters of diameter and
focal length of 5.6 m. The described concentrators are part of an innovative
camera made up of silicon-photomultipliers sensors, although a similar approach
can be used for other sizes of single-mirror telescopes with different camera
sensors, including photomultipliers. The challenge of our approach is to
achieve a cost-effective design suitable for standard industrial productions of
both the plastic concentrator substrate and the reflective coating. At the same
time we maximize the optical performance. In this paper we also describe the
optical set-up to measure the absolute collection efficiency of the light
guides and demonstrate our good understanding of the measured data using a
professional light tracing simulation.
[35]
oai:arXiv.org:1403.3573 [pdf] - 797027
FACT -- The G-APD revolution in Cherenkov astronomy
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. S.;
Knoetig, M. L.;
Köhne, J. H.;
Krähenbühl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Müuller, S.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Röser, U.;
Stucki, J. P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zänglein, M.
Submitted: 2014-03-14
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.
[36]
oai:arXiv.org:1308.1512 [pdf] - 1934965
FACT - The First G-APD Cherenkov Telescope: Status and Results
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-08-07
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results.
[37]
oai:arXiv.org:1307.7892 [pdf] - 699793
FACT: Towards Robotic Operation of an Imaging Air Cherenkov Telescope
Biland, A.;
Anderhub, H.;
Backes, M.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-07-30
The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in
October 2011. Since summer 2012, due to very smooth and stable operation, it is
the first telescope of its kind that is routinely operated from remote, without
the need for a data-taking crew on site. In addition, many standard tasks of
operation are executed automatically without the need for manual interaction.
Based on the experience gained so far, some alterations to improve the safety
of the system are under development to allow robotic operation in the future.
We present the setup and precautions used to implement remote operations and
the experience gained so far, as well as the work towards robotic operation.
[38]
oai:arXiv.org:1307.3137 [pdf] - 1937867
4 m Davies-Cotton telescope for the Cherenkov Telescope Array
Moderski, R.;
Aguilar, J. A.;
Barnacka, A.;
Basili, A.;
Boccone, V.;
Bogacz, L.;
Cadoux, F.;
Christov, A.;
Della Volpe, M.;
Dyrda, M.;
Frankowski, A.;
Grudzińska, M.;
Janiak, M.;
Karczewski, M.;
Kasperek, J.;
Kochański, W.;
Korohoda, P.;
Kozioł, J.;
Lubiński, P.;
Ludwin, J.;
Lyard, E.;
Marszałek, A.;
Michałowski, J.;
Montaruli, T.;
Nicolau-Kukliński, J.;
Niemiec, J.;
Ostrowski, M.;
Płatos, Ł.;
Rajda, P. J.;
Rameez, M.;
Romaszkan, W.;
Rupiński, M.;
Seweryn, K.;
Stodulska, M.;
Stodulski, M.;
Walter, R.;
Winiarski, K.;
Wiśniewski, Ł.;
Zagdański, A.;
Zietara, K.;
Ziółkowski, P.;
Żychowski, P.
Submitted: 2013-07-11
The Cherenkov Telescope Array (CTA) is the next generation very high energy
gamma-ray observatory. It will consist of three classes of telescopes, of
large, medium and small sizes. The small telescopes, of 4 m diameter, will be
dedicated to the observations of the highest energy gamma-rays, above several
TeV. We present the technical characteristics of a single mirror, 4 m diameter,
Davies-Cotton telescope for the CTA and the performance of the sub-array
consisting of the telescopes of this type. The telescope will be equipped with
a fully digital camera based on custom made, hexagonal Geiger-mode avalanche
photodiodes. The development of cameras based on such devices is an RnD since
traditionally photomultipliers are used. The photodiodes are now being
characterized at various institutions of the CTA Consortium. Glass mirrors will
be used, although an alternative is being considered: composite mirrors that
could be adopted if they meet the project requirements. We present a design of
the telescope structure, its components and results of the numerical
simulations of the telescope performance.
[39]
oai:arXiv.org:1304.1710 [pdf] - 680263
Design and Operation of FACT -- The First G-APD Cherenkov Telescope
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
K"ohne, J. H.;
Kr"ahenb"uhl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
R"oser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Z"anglein, M.
Submitted: 2013-04-05
The First G-APD Cherenkov Telescope (FACT) is designed to detect cosmic
gamma-rays with energies from several hundred GeV up to about 10 TeV using the
Imaging Atmospheric Cherenkov Technique. In contrast to former or existing
telescopes, the camera of the FACT telescope is comprised of solid-state
Geiger-mode Avalanche Photodiodes (G-APD) instead of photomultiplier tubes for
photo detection. It is the first full-scale device of its kind employing this
new technology. The telescope is operated at the Observatorio del Roque de los
Muchachos (La Palma, Canary Islands, Spain) since fall 2011. This paper
describes in detail the design, construction and operation of the system,
including hardware and software aspects. Technical experiences gained after one
year of operation are discussed and conclusions with regard to future projects
are drawn.
[40]
oai:arXiv.org:1209.1497 [pdf] - 1151206
LOFT: the Large Observatory For X-ray Timing
Feroci, M.;
Herder, J. W. den;
Bozzo, E.;
Barret, D.;
Brandt, S.;
Hernanz, M.;
van der Klis, M.;
Pohl, M.;
Santangelo, A.;
Stella, L.;
Watts, A.;
Wilms, J.;
Zane, S.;
Ahangarianabhari, M.;
Alpar, A.;
Altamirano, D.;
Alvarez, L.;
Amati, L.;
Amoros, C.;
Andersson, N.;
Antonelli, A.;
Argan, A.;
Artigue, R.;
Azzarello, P.;
Baldazzi, G.;
Balman, S.;
Barbera, M.;
Belloni, T.;
Bertuccio, G.;
Bianchi, S.;
Bianchini, A.;
Bodin, P.;
Bidaud, J. -M. Bonnet;
Boutloukos, S.;
Braga, J.;
Brown, E.;
Bucciantini, N.;
Burderi, L.;
Bursa, M.;
Budtz-Jørgensen, C.;
Cackett, E.;
Cadoux, F. R.;
Cais, P.;
Caliandro, G. A.;
Campana, R.;
Campana, S.;
Casella, P.;
Chakrabarty, D.;
Chenevez, J.;
Coker, J.;
Cole, R.;
Collura, A.;
Courvoisier, T.;
Cros, A.;
Cumming, A.;
Cusumano, G.;
D'Aì, A.;
D'Elia, V.;
Del Monte, E.;
De Martino, D.;
De Rosa, A.;
Di Cosimo, S.;
Diebold, S.;
Di Salvo, T.;
Donnarumma, I.;
Drago, A.;
Durant, M.;
Emmanoulopoulos, D.;
Evangelista, Y.;
Fabian, A.;
Falanga, M.;
Favre, Y.;
Feldman, C.;
Ferrigno, C.;
Finger, M. H.;
Fraser, G. W.;
Fuschino, F.;
Galloway, D. K.;
Sanchez, J. L. Galvez;
Garcia-Berro, E.;
Gendre, B.;
Gezari, S.;
Giles, A. B.;
Gilfanov, M.;
Giommi, P.;
Giovannini, G.;
Giroletti, M.;
Goldwurm, A.;
Götz, D.;
Gouiffes, C.;
Grassi, M.;
Guidorzi, P. Groot C.;
Haas, D.;
Hansen, F.;
Hartmann, D. H.;
Haswe, C. A.;
Heger, A.;
Homan, J.;
Hornstrup, A.;
Hudec, R.;
Huovelin, J.;
Ingram, A.;
Zand, J. J. M. in't;
Isern, J.;
Israe, G.;
Izzo, L.;
Jonker, P.;
Kaaret, P.;
Karas, V.;
Karelin, D.;
Kataria, D.;
Keek, L.;
Kennedy, T.;
Klochkov, D.;
Kluzniak, W.;
Kokkotas, K.;
Korpela, S.;
Kouveliotou, C.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kuvvetli, I.;
Labanti, C.;
Lai, D.;
Lamb, F. K.;
Lebrun, F.;
Lin, D.;
Linder, D.;
Lodato, G.;
Longo, F.;
Lund, N.;
Maccarone, T. J.;
Macera, D.;
Maier, D.;
Malcovati, P.;
Mangano, V.;
Manousakis, A.;
Marisaldi, M.;
Markowitz, A.;
Martindale, A.;
Matt, G.;
McHardy, I. M.;
Melatos, A.;
Mendez, M.;
Migliari, S.;
Mignani, R.;
Miller, M. C.;
Miller, J. M.;
Mineo, T.;
Miniutti, G.;
Morsink, S.;
Motch, C.;
Motta, S.;
Mouchet, M.;
Muleri, F.;
Norton, A. J.;
Nowak, M.;
O'Brien, P.;
Orienti, M.;
Orio, M.;
Orlandini, M.;
Orleanski, P.;
Osborne, J. P.;
Osten, R.;
Ozel, F.;
Pacciani, L.;
Papitto, A.;
Paul, B.;
Perinati, E.;
Petracek, V.;
Portell, J.;
Poutanen, J.;
Psaltis, D.;
Rambaud, D.;
Ramsay, G.;
Rapisarda, M.;
Rachevski, A.;
Ray, P. S.;
Rea, N.;
Reddy, S.;
Reig, P.;
Aranda, M. Reina;
Remillard, R.;
Reynolds, C.;
Rodríguez-Gil, P.;
Rodriguez, J.;
Romano, P.;
Rossi, E. M. R.;
Ryde, F.;
Sabau-Graziati, L.;
Sala, G.;
Salvaterra, R.;
Sanna, A.;
Schanne, S.;
Schee, J.;
Schmid, C.;
Schwenk, A.;
Schwope, A. D.;
Seyler, J. -Y.;
Shearer, A.;
Smith, A.;
Smith, D. M.;
Smith, P. J.;
Sochora, V.;
Soffitta, P.;
Soleri, P.;
Stappers, B.;
Stelzer, B.;
Stergioulas, N.;
Stratta, G.;
Strohmayer, T. E.;
Stuchlik, Z.;
Suchy, S.;
Sulemainov, V.;
Takahashi, T.;
Tamburini, F.;
Tenzer, C.;
Tolos, L.;
Torok, G.;
Torrejon, J. M.;
Torres, D. F.;
Tramacere, A.;
Trois, A.;
Turriziani, S.;
Uter, P.;
Uttley, P.;
Vacchi, A.;
Varniere, P.;
Vaughan, S.;
Vercellone, S.;
Vrba, V.;
Walton, D.;
Watanabe, S.;
Wawrzaszek, R.;
Webb, N.;
Weinberg, N.;
Wende, H.;
Wheatley, P.;
Wijers, R.;
Wijnands, R.;
Wille, M.;
Wilson-Hodge, C. A.;
Winter, B.;
Wood, K.;
Zampa, G.;
Zampa, N.;
Zampieri, L.;
Zdziarski, A.;
Zhang, B.
Submitted: 2012-09-07
The LOFT mission concept is one of four candidates selected by ESA for the M3
launch opportunity as Medium Size missions of the Cosmic Vision programme. The
launch window is currently planned for between 2022 and 2024. LOFT is designed
to exploit the diagnostics of rapid X-ray flux and spectral variability that
directly probe the motion of matter down to distances very close to black holes
and neutron stars, as well as the physical state of ultra-dense matter. These
primary science goals will be addressed by a payload composed of a Large Area
Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1
degree field of view) experiment operating in the energy range 2-50 keV, with a
10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM
will operate in the same energy range as the LAD, enabling simultaneous
monitoring of a few-steradian wide field of view, with an angular resolution of
<5 arcmin. The LAD and WFM experiments will allow us to investigate variability
from submillisecond QPO's to year-long transient outbursts. In this paper we
report the current status of the project.
[41]
oai:arXiv.org:1209.1498 [pdf] - 1151207
A Large Area Detector proposed for the Large Observatory for X-ray
Timing (LOFT)
Zane, S.;
Walton, D.;
Kennedy, T.;
Feroci, M.;
Herder, J. -W. Den;
Ahangarianabhari, M.;
Argan, A.;
Azzarello, P.;
Baldazzi, G.;
Barret, D.;
Bertuccio, G.;
Bodini, P.;
Bozzo, E.;
Cadoux, F.;
Cais, P.;
Campana, R.;
Coker, J.;
Cros, A.;
Del Monte, E.;
De Rosa, A.;
Di Cosimo, S.;
Donnarumma, I.;
Evangelista, Y.;
Favre, Y.;
Feldman, C.;
Fraser, G.;
Fuschino, F.;
Grassi, M.;
Hailey, M. R.;
Hudec, R.;
Labanti, C.;
Macera, D.;
Malcovati, P.;
Marisaldi, M.;
Martindale, A.;
Mineo, T.;
Muleri, F.;
Nowak, M.;
Orlandini, M.;
Pacciani, L.;
Perinati, E.;
Petracek, V.;
Pohl, M.;
Rachevski, A.;
Smith, P.;
Santangelo, A.;
Seyler, J. -Y.;
Schmid, C.;
Soffitta, P.;
Suchy, S.;
Tenzer, C.;
Uttley, P.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Wilms, J.;
Winter, B.
Submitted: 2012-09-07
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate
ESA M3 missions considered for launch in the 2022 time-frame. It is
specifically designed to perform fast X-ray timing and probe the status of the
matter near black holes and neutron stars. The LOFT scientific payload is
composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD
is a 10 m2-class pointed instrument with 20 times the collecting area of the
best past timing missions (such as RXTE) over the 2-30 keV range, which holds
the capability to revolutionize studies of X-ray variability down to the
millisecond time scales. Its ground-breaking characteristic is a low mass per
unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable
weight. The development of such large but light experiment, with low mass and
power per unit area, is now made possible by the recent advancements in the
field of large-area silicon detectors - able to time tag an X-ray photon with
an accuracy <10 {\mu}s and an energy resolution of ~260 eV at 6 keV - and
capillary-plate X-ray collimators. In this paper, we will summarize the
characteristics of the LAD instrument and give an overview of its capabilities.