Normalized to: Bockstiegel, C.
[1]
oai:arXiv.org:2007.06496 [pdf] - 2132084
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave
Device Arrays
Smith, Jennifer Pearl;
Mazin, Benjamin A.;
Walter, Alex B.;
Daal, Miguel;
Bailey,, J. I.;
Bockstiegel, Clinton;
Zobrist, Nicholas;
Swimmer, Noah;
Steiger, Sarah;
Fruitwala, Neelay
Submitted: 2020-07-13
Superconducting electronics often require high-density microwave
interconnects capable of transporting signals between temperature stages with
minimal loss, cross talk, and heat conduction. We report the design and
fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial
ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner
conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm
thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on
connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick)
soldered to a coplanar wave guide transition board. The 30 cm long cable has 1
dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss
is 0.5 dB more than commercially available superconducting coax likely due to
impedance mismatches caused by manufacturing imperfections in the cable. The
reported cross talk is 30 dB lower than previously developed laminated
NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to
be 20 nW per trace, approximately half the computed load from the smallest
commercially available superconducting coax from CryoCoax
[2]
oai:arXiv.org:1911.06434 [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance
Detectors
Zobrist, Nicholas;
Coiffard, Grégoire;
Bumble, Bruce;
Swimmer, Noah;
Steiger, Sarah;
Daal, Miguel;
Collura, Giulia;
Walter, Alex B.;
Bockstiegel, Clint;
Fruitwala, Neelay;
Lipartito, Isabel;
Mazin, Benjamin A.
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[3]
oai:arXiv.org:1908.02775 [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in
the 2020s
Mazin, Benjamin A.;
Bailey, Jeb;
Bartlett, Jo;
Bockstiegel, Clint;
Bumble, Bruce;
Coiffard, Gregoire;
Currie, Thayne;
Daal, Miguel;
Davis, Kristina;
Dodkins, Rupert;
Fruitwala, Neelay;
Jovanovic, Nemanja;
Lipartito, Isabel;
Lozi, Julien;
Males, Jared;
Mawet, Dimitri;
Meeker, Seth;
O'Brien, Kieran;
Rich, Michael;
Smith, Jenny;
Steiger, Sarah;
Swimmer, Noah;
Walter, Alex;
Zobrist, Nick;
Zmuidzinas, Jonas
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are
superconducting photon counting detectors capable of measuring the energy and
arrival time of individual OIR photons without read noise or dark current. In
this whitepaper we will discuss the current status of OIR MKIDs and MKID-based
instruments.
[4]
oai:arXiv.org:1907.03078 [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical
Microwave Kinetic Inductance Detectors
Zobrist, Nicholas;
Eom, Byeong Ho;
Day, Peter;
Mazin, Benjamin A.;
Meeker, Seth R.;
Bumble, Bruce;
LeDuc, Henry G.;
Coiffard, Gérgoire;
Szypryt, Paul;
Fruitwala, Neelay;
Lipartito, Isabel;
Bockstiegel, Clint
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic
Inductance Detector (MKID) can be degraded by noise coming from the primary low
temperature amplifier in the detector's readout system. Until recently, quantum
limited amplifiers have been incompatible with these detectors due to dynamic
range, power, and bandwidth constraints. However, we show that a kinetic
inductance based traveling wave parametric amplifier can be used for this
application and reaches the quantum limit. The total system noise for this
readout scheme was equal to ~2.1 in units of quanta. For incident photons in
the 800 to 1300 nm range, the amplifier increased the average resolving power
of the detector from ~6.7 to 9.3 at which point the resolution becomes limited
by noise on the pulse height of the signal. Noise measurements suggest that a
resolving power of up to 25 is possible if redesigned detectors can remove this
additional noise source.
[5]
oai:arXiv.org:1906.03354 [pdf] - 1975296
Stochastic Speckle Discrimination with Time-Tagged Photon Lists: Digging
Below the Speckle Noise Floor
Submitted: 2019-06-07
We present an algorithm that uses the distribution of photon arrival times to
distinguish speckles from incoherent sources, like planets and disks, in high
contrast images. Using simulated data, we show that our approach can overcome
the noise limit from fluctuating speckle intensity. The algorithm is likely to
be most advantageous when a coronagraph limits the coherent diffraction pattern
in the image plane but the intensity is still strongly modulated by
fast-timescale uncorrected stellar light, for example from atmospheric
turbulence. These conditions are common at small inner working angles and will
allow probing of exoplanet populations at smaller angular separations. The
technique requires a fast science camera that can temporally resolve the
speckle fluctuations, and the detection of many photons per speckle
decorrelation time. Since the algorithm directly extracts the incoherent light,
standard differential imaging post-processing techniques can be performed
afterwards to further boost the signal.
[6]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[7]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.
[8]
oai:arXiv.org:1610.00725 [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance
Detectors
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors
(MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging
superconducting detector technology, capable of measuring the arrival times of
single photons to better than two microseconds and their energies to around ten
percent. Previously, MKIDs have been fabricated using either sub-stoichiometric
titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in
the superconducting critical temperature and Al has a low kinetic inductance
fraction, causing low detector sensitivity. To address these issues, we have
instead fabricated PtSi microresonators with superconducting critical
temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim
10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp}
\approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$,
of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail
the substantial advantages that PtSi MKIDs have to offer.
[9]
oai:arXiv.org:1509.02950 [pdf] - 1385376
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements
Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Sayers, Jack;
Zemcov, Michael;
Glenn, Jason;
Golwala, Sunil R.;
Maloney, Philip R.;
Siegel, Seth R.;
Wheeler, Jordan;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran P.;
Gao, Jiansong;
Hollister, Matthew I.;
Lam, Albert;
LeDuc, Henry G.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David A.;
Mroczkowski, Tony K.;
Noroozian, Omid;
Nguyen, Hien T.;
Radford, Simon J.;
Schlaerth, James A.;
Vayonakis, Anastasios;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2015-09-09, last modified: 2016-03-01
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images
towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech
Submillimeter Observatory with the Multiwavelength Submillimeter Inductance
Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As
part of our analysis, we have used higher frequency data from Herschel-SPIRE
and previously published lower frequency radio data to subtract the signal from
the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the
AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined
with X-ray spectroscopic measurements of the temperature of the intra-cluster
medium (ICM) from Chandra, we constrain the ICM optical depth to be $\tau_e =
7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar
velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both
quantities are limited by measurement noise rather than calibration
uncertainties or astrophysical contamination, and significant improvements are
possible with deeper observations. Our best-fit velocity is in good agreement
with one previously published SZ effect analysis and in mild tension with the
other, although some or all of that tension may be because that measurement
samples a much smaller cluster volume. Furthermore, our best-fit optical depth
implies a gas mass slightly larger than the Chandra-derived value, implying the
cluster is elongated along the line of sight.
[10]
oai:arXiv.org:1506.07537 [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray
Imaging Spectroscopy
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of
view is often as important as high energy resolution, but current X-ray
detectors do not provide both in the same device. Thermal Kinetic Inductance
Detectors (TKIDs) are being developed as they offer a feasible way to combine
the energy resolution of transition edge sensors with pixel counts approaching
CCDs and thus promise significant improvements for many X-ray spectroscopy
applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors
(MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels
have recently been demonstrated and much bigger arrays are under development.
In this work, we present our first working TKID prototypes which are able to
achieve an energy resolution of 75 eV at 5.9 keV, even though their general
design still has to be optimized. We further describe TKID fabrication,
characterization, multiplexing and working principle and demonstrate the
necessity of a data fitting algorithm in order to extract photon energies. With
further design optimizations we expect to be able to improve our TKID energy
resolution to less than 10 eV at 5.9 keV.
[11]
oai:arXiv.org:1211.0595 [pdf] - 585603
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Golwala, Sunil R.;
Bockstiegel, Clint;
Brugger, Spencer;
Czakon, Nicole G.;
Day, Peter K.;
Downes, Thomas P.;
Duan, Ran;
Gao, Jiansong;
Gill, Amandeep K.;
Glenn, Jason;
Hollister, Matthew I.;
LeDuc, Henry G.;
Maloney, Philip R.;
Mazin, Benjamin A.;
McHugh, Sean G.;
Miller, David;
Noroozian, Omid;
Nguyen, Hien T.;
Sayers, Jack;
Schlaerth, James A.;
Siegel, Seth;
Vayonakis, Anastasios K.;
Wilson, Philip R.;
Zmuidzinas, Jonas
Submitted: 2012-11-03
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance
Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is
designed to have a 14', diffraction-limited field-of-view instrumented with
2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04,
1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies,
galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own
and nearby galaxies. MUSIC uses broadband superconducting phased-array
slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to
define spectral bands, and microwave kinetic inductance detectors to
senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72
spatial pixels each. It is coupled to the telescope via an ambient temperature
ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the
image of the primary mirror formed by the ellipsoidal mirror. Dielectric and
metal mesh filters are used to block thermal infrared and out-of-band
radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle
cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates
Earth's magnetic field. Each focal plane tile is read out by a single pair of
coaxes and a HEMT amplifier. The readout system consists of 16 copies of
custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We
focus on recent updates on the instrument design and results from the
commissioning of the full camera in 2012.