Normalized to: Bettolo, C.
[1]
oai:arXiv.org:0709.1278 [pdf] - 4742
PoGOLite - A High Sensitivity Balloon-Borne Soft Gamma-ray Polarimeter
Kamae, Tuneyoshi;
Andersson, Viktor;
Arimoto, Makoto;
Axelsson, Magnus;
Bettolo, Cecilia Marini;
Björnsson, Claes-Ingvar;
Bogaert, Gilles;
Carlson, Per;
Craig, William;
Ekeberg, Tomas;
Engdegård, Olle;
Fukazawa, Yasushi;
Gunji, Shuichi;
Hjalmarsdotter, Linnea;
Iwan, Bianca;
Kanai, Yoshikazu;
Kataoka, Jun;
Kawai, Nobuyuki;
Kazejev, Jaroslav;
Kiss, Mózsi;
Klamra, Wlodzimierz;
Larsson, Stefan;
Madejski, Grzegorz;
Mizuno, Tsunefumi;
Ng, Johnny;
Pearce, Mark;
Ryde, Felix;
Suhonen, Markus;
Tajima, Hiroyasu;
Takahashi, Hiromitsu;
Takahashi, Tadayuki;
Tanaka, Takuya;
Thurston, Timothy;
Ueno, Masaru;
Varner, Gary;
Yamamoto, Kazuhide;
Yamashita, Yuichiro;
Ylinen, Tomi;
Yoshida, Hiroaki
Submitted: 2007-09-09, last modified: 2008-04-21
We describe a new balloon-borne instrument (PoGOLite) capable of detecting
10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6
hour flight. Polarisation measurements in the soft gamma-ray band are expected
to provide a powerful probe into high-energy emission mechanisms as well as the
distribution of magnetic fields, radiation fields and interstellar matter. At
present, only exploratory polarisation measurements have been carried out in
the soft gamma-ray band. Reduction of the large background produced by
cosmic-ray particles has been the biggest challenge. PoGOLite uses Compton
scattering and photo-absorption in an array of 217 well-type phoswich detector
cells made of plastic and BGO scintillators surrounded by a BGO anticoincidence
shield and a thick polyethylene neutron shield. The narrow FOV (1.25msr)
obtained with well-type phoswich detector technology and the use of thick
background shields enhance the detected S/N ratio. Event selections based on
recorded phototube waveforms and Compton kinematics reduce the background to
that expected for a 40-100mCrab source between 25 and 50keV. A 6 hour
observation on the Crab will differentiate between the Polar Cap/Slot Gap,
Outer Gap, and Caustic models with greater than 5 sigma; and also cleanly
identify the Compton reflection component in the Cygnus X-1 hard state. The
first flight is planned for 2010 and long-duration flights from Sweden to
Northern Canada are foreseen thereafter.
[2]
oai:arXiv.org:0704.1603 [pdf] - 357
Measuring energy dependent polarization in soft gamma-rays using Compton
scattering in PoGOLite
Axelsson, M.;
Engdegård, O.;
Ryde, F.;
Larsson, S.;
Pearce, M.;
Hjalmarsdotter, L.;
Kiss, M.;
Bettolo, C. Marini;
Arimoto, M.;
Björnsson, C-I.;
Carlson, P.;
Fukazawa, Y.;
Kamae, T.;
Kanai, Y.;
Kataoka, J.;
Kawai, N.;
Klamra, W.;
Madejski, G.;
Mizuno, T.;
Ng, J.;
Tajima, H.;
Takahashi, T.;
Tanaka, T.;
Ueno, M.;
Varner, G.;
Yamamoto, K.
Submitted: 2007-04-12, last modified: 2007-06-28
Linear polarization in X- and gamma-rays is an important diagnostic of many
astrophysical sources, foremost giving information about their geometry,
magnetic fields, and radiation mechanisms. However, very few X-ray polarization
measurements have been made, and then only mono-energetic detections, whilst
several objects are assumed to have energy dependent polarization signatures.
In this paper we investigate whether detection of energy dependent polarization
from cosmic sources is possible using the Compton technique, in particular with
the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use
Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus
X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6
and 35 hours were simulated, corresponding to a standard and a long duration
flight respectively. Both smooth and sharp energy variations of the
polarization are investigated and compared to constant polarization signals
using chi-square statistics. We can reject constant polarization, with energy,
for the Cygnus X-1 spectrum (in the hard state), if the reflected component is
assumed to be completely polarized, whereas the distinction cannot be made for
weaker polarization. For the accreting pulsar, constant polarization can be
rejected in the case of polarization in a narrow energy band with at least 50%
polarization, and similarly for a negative step distribution from 30% to 0%
polarization.