Normalized to: Bao, T.
[1]
oai:arXiv.org:1901.04207 [pdf] - 1857202
Detailed polarization measurements of the prompt emission of five
Gamma-Ray Bursts
Zhang, Shuang-Nan;
Kole, Merlin;
Bao, Tian-Wei;
Batsch, Tadeusz;
Bernasconi, Tancredi;
Cadoux, Franck;
Chai, Jun-Ying;
Dai, Zi-Gao;
Dong, Yong-Wei;
Gauvin, Neal;
Hajdas, Wojtek;
Lan, Mi-Xiang;
Li, Han-Cheng;
Li, Lu;
Li, Zheng-Heng;
Liu, Jiang-Tao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Produit, Nicolas;
Pohl, Martin;
Rybka, Dominik;
Shi, Hao-Li;
Song, Li-Ming;
Sun, Jian-Chao;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Rui-Jie;
Wang, Yuan-Hao;
Wen, Xing;
Wu, Bo-Bing;
Wu, Xin;
Wu, Xue-Feng;
Xiao, Hua-Lin;
Xiong, Shao-Lin;
Zhang, Lai-Yu;
Zhang, Li;
Zhang, Xiao-Feng;
Zhang, Yong-Jie;
Zwolinska, Anna
Submitted: 2019-01-14
Gamma-ray bursts are the strongest explosions in the Universe since the Big
Bang, believed to be produced either in forming black holes at the end of
massive star evolution or merging of compact objects. Spectral and timing
properties of gamma-ray bursts suggest that the observed bright gamma-rays are
produced in the most relativistic jets in the Universe; however, the physical
properties, especially the structure and magnetic topologies in the jets are
still not well known, despite several decades of studies. It is widely believed
that precise measurements of the polarization properties of gamma-ray bursts
should provide crucial information on the highly relativistic jets. As a result
there have been many reports of gamma-ray burst polarization measurements with
diverse results, see, however many such measurements suffered from substantial
uncertainties, mostly systematic. After the first successful measurements by
the GAP and COSI instruments, here we report a statistically meaningful sample
of precise polarization measurements, obtained with the dedicated gamma-ray
burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results
suggest that the gamma-ray emission is at most polarized at a level lower than
some popular models have predicted; although our results also show intrapulse
evolution of the polarization angle. This indicates that the low polarization
degrees could be due to an evolving polarization angle during a gamma-ray
burst.
[2]
oai:arXiv.org:1710.08918 [pdf] - 1724839
In-flight energy calibration of the space-borne Compton polarimeter
POLAR
Xiao, Hualin;
Hajdas, Wojtek;
Wu, Bobing;
Produit, Nicolas;
Sun, Jianchao;
Kole, Merlin;
Bao, Tianwei;
Bernasconi, Tancredi;
Batsch, Tadeusz;
Cadoux, Franck;
Chai, Junying;
Dong, Yongwei;
Egli, Ken;
Gauvin, Neal;
Kong, Minnan;
Kramert, Reinhold;
Kong, Siwei;
Li, Hancheng;
Li, Lu;
Li, Zhengheng;
Liu, Jiangtao;
Liu, Xin;
Marcinkowski, Radoslaw;
Orsi, Silvio;
Rybka, Dominik K.;
Pohl, Martin;
Shi, Haoli;
Song, Liming;
Xiong, Shaolin;
Szabelski, Jacek;
Socha, Patryk;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Zhang, Laiyu;
Zhang, Ping;
Zhang, Shuangnan;
Zhang, Xiaofeng;
Zhang, Yongjie;
Zhao, Yi;
Zwolinska, Anna
Submitted: 2017-10-24, last modified: 2018-06-05
POLAR is a compact wide-field space-borne detector for precise measurements
of the linear polarisation of hard X-rays emitted by transient sources in the
energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of
plastic scintillator bars used as a detection material. The bars are grouped in
25 detector modules. The energy range sensitivity of POLAR is optimized to
match with the prompt emission photons from the gamma-ray bursts (GRBs).
Polarization measurements of the prompt emission would probe source geometries,
emission mechanisms and magnetic structures in GRB jets. The instrument can
also detect hard X-rays from solar flares and be used for precise measurement
of their polarisation. POLAR was launched into a low Earth orbit on-board the
Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in
polarisation measurements it is essential to assure both before and during the
flight a precise energy calibration. Such calibrations are performed with four
low activity $^{22}$Na radioactive sources placed inside the instrument. Energy
conversion factors are related to Compton edge positions from the collinear
annihilation photons from the sources. This paper presents main principles of
the in-flight calibration, describes studies of the method based on Monte Carlo
simulations and its laboratory verification and finally provides some
observation results based on the in-flight data analysis.
[3]
oai:arXiv.org:1805.07605 [pdf] - 1690419
In-Orbit Instrument Performance Study and Calibration for POLAR
Polarization Measurements
Li, Zhengheng;
Kole, Merlin;
Sun, Jianchao;
Song, Liming;
Produit, Nicolas;
Wu, Bobing;
Bao, Tianwei;
Bernasconi, Tancredi;
Cadoux, Franck;
Dong, Yongwei;
Feng, Minzi;
Gauvin, Neal;
Hajdas, Wojtek;
Li, Hancheng;
Li, Lu;
Liu, Xin;
Marcinkowski, Radoslaw;
Pohl, Martin;
Rybka, Dominik K.;
Shi, Haoli;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Xiong, Shaolin;
Zwolinska, Anna;
Zhang, Li;
Zhang, Laiyu;
Zhang, Shuangnan;
Zhang, Yongjie;
Zhao, Yi
Submitted: 2018-05-19, last modified: 2018-05-28
POLAR is a compact space-borne detector designed to perform reliable
measurements of the polarization for transient sources like Gamma-Ray Bursts in
the energy range 50-500keV. The instrument works based on the Compton
Scattering principle with the plastic scintillators as the main detection
material along with the multi-anode photomultiplier tube. POLAR has been
launched successfully onboard the Chinese space laboratory TG-2 on 15th
September, 2016. In order to reliably reconstruct the polarization information
a highly detailed understanding of the instrument is required for both data
analysis and Monte Carlo studies. For this purpose a full study of the in-orbit
performance was performed in order to obtain the instrument calibration
parameters such as noise, pedestal, gain nonlinearity of the electronics,
threshold, crosstalk and gain, as well as the effect of temperature on the
above parameters. Furthermore the relationship between gain and high voltage of
the multi-anode photomultiplier tube has been studied and the errors on all
measurement values are presented. Finally the typical systematic error on
polarization measurements of Gamma-Ray Bursts due to the measurement error of
the calibration parameters are estimated using Monte Carlo simulations.
[4]
oai:arXiv.org:1804.02309 [pdf] - 1665486
Mass Measurements of Neutron-Deficient Y, Zr, and Nb Isotopes and Their
Impact on $rp$ and $\nu p$ Nucleosynthesis Processes
Xing, Y. M.;
Li, K. A.;
Zhang, Y. H.;
Zhou, X. H.;
Wang, M.;
Litvinov, Yu. A.;
Blaum, K.;
Wanajo, S.;
Kubono, S.;
MartÃnez-Pinedo, G.;
Sieverding, A.;
Chen, R. J.;
Shuai, P.;
Fu, C. Y.;
Yan, X. L.;
Huang, W. J.;
Xu, X.;
Tang, X. D.;
Xu, H. S.;
Bao, T.;
Chen, X. C.;
Gao, B. S.;
He, J. J.;
Lam, Y. H.;
Li, H. F.;
Liu, J. H.;
Ma, X. W.;
Mao, R. S.;
Si, M.;
Sun, M. Z.;
Tu, X. L.;
Wang, Q.;
Yang, J. C.;
Yuan, Y. J.;
Zeng, Q.;
Zhang, P.;
Zhou, X.;
Zhan, W. L.;
Litvinov, S.;
Audi, G.;
Uesaka, T.;
Yamaguchi, Y.;
Yamaguchi, T.;
Ozawa, A.;
Fröhlich, C.;
Rauscher, T.;
Thielemann, F. -K.;
Sun, B. H.;
Sun, Y.;
Dai, A. C.;
Xu, F. R.
Submitted: 2018-04-06
Using isochronous mass spectrometry at the experimental storage ring CSRe in
Lanzhou, the masses of $^{82}$Zr and $^{84}$Nb were measured for the first time
with an uncertainty of $\sim 10$ keV, and the masses of $^{79}$Y, $^{81}$Zr,
and $^{83}$Nb were re-determined with a higher precision. %The latter differ
significantly from their literature values. The latter are significantly less
bound than their literature values. Our new and accurate masses remove the
irregularities of the mass surface in this region of the nuclear chart. Our
results do not support the predicted island of pronounced low $\alpha$
separation energies for neutron-deficient Mo and Tc isotopes, making the
formation of Zr-Nb cycle in the $rp$-process unlikely. The new proton
separation energy of $^{83}$Nb was determined to be 490(400)~keV smaller than
that in the Atomic Mass Evaluation 2012. This partly removes the overproduction
of the $p$-nucleus $^{84}$Sr relative to the neutron-deficient molybdenum
isotopes in the previous $\nu p$-process simulations.
[5]
oai:arXiv.org:1804.00786 [pdf] - 1659821
An Empirical Correlation of $T_{\rm max}$ - $M_{\rm WD}$ of Dwarf Novae
and The Average White Dwarf Mass in Cataclysmic Variables in the Galactic
Bulge
Submitted: 2018-04-02
The mean white dwarf (WD) mass in the Galactic bulge cataclysmic variables
(CVs) was measured by applying the the shock temperature-WD mass correlation of
magnetic cataclysmic variables (mCVs) to the Galactic Bulge X-ray Emission
(GBXE) spectra. However, the resulting mean WD mass is lower than that of the
local CVs. This discrepancy could be explained by the dominating sources in the
GBXE are non-mCVs instead of mCVs. In this work, we conduct an thorough
investigation on the X-ray spectra of local DNe from \suzaku\ archives, and
derive semi-empirical correlations between the shock temperature $T_{\rm max}$,
the flux ratio of \fec\ to \feb\ lines, and WD mass for quiescent, non-magnetic
CVs. By applying these correlations to the GBXE, we derive the average WD mass
of CVs in the Galactic bulge to be $0.81\pm 0.07M_\odot$. This value is
consistent with previous optical measurements of WD mass in local CVs.
[6]
oai:arXiv.org:1709.07191 [pdf] - 1588657
Design and construction of the POLAR detector
Produit, N.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Britvich, I.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
Kole, M.;
Kong, M. N.;
Kramert, R.;
Li, L.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Rutczynska, A.;
Shi, H. L.;
Socha, P.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Traseira, I.;
Xiao, H. L.;
Wang, R. J.;
Wen, X.;
Wu, B. B.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-09-21, last modified: 2017-09-28
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a
wide field of view, which covers almost half the sky. The instrument uses
Compton scattering of gamma rays on a plastic scintillator hodoscope to measure
the polarization of the incoming photons. The instrument has been successfully
launched on board of the Chinese space laboratory Tiangong~2 on September 15,
2016. The construction of the instrument components is described in this
article. Details are provided on problems encountered during the construction
phase and their solutions. Initial performance of the instrument in orbit is as
expected from ground tests and Monte Carlo simulation.
[7]
oai:arXiv.org:1708.00664 [pdf] - 1586674
Instrument Performance and Simulation Verification of the POLAR Detector
Kole, M.;
Li, Z. H.;
Produit, N.;
Tymieniecka, T.;
Zhang, J.;
Zwolinska, A.;
Bao, T. W.;
Bernasconi, T.;
Cadoux, F.;
Feng, M. Z.;
Gauvin, N.;
Hajdas, W.;
Kong, S. W.;
Li, H. C.;
Li, L.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rybka, D.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zhao, Y.
Submitted: 2017-08-02
POLAR is a new satellite-born detector aiming to measure the polarization of
an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The
instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of
September 2016, is designed to measure the polarization of the hard X-ray flux
by measuring the distribution of the azimuthal scattering angles of the
incoming photons. A detailed understanding of the polarimeter and specifically
of the systematic effects induced by the instrument's non-uniformity are
required for this purpose. In order to study the instrument's response to
polarization, POLAR underwent a beam test at the European Synchrotron Radiation
Facility in France. In this paper both the beam test and the instrument
performance will be described. This is followed by an overview of the Monte
Carlo simulation tools developed for the instrument. Finally a comparison of
the measured and simulated instrument performance will be provided and the
instrument response to polarization will be presented.
[8]
oai:arXiv.org:1704.06173 [pdf] - 1567780
Calibration of the Space-borne Compton Polarimeter POLAR flight model
with 100% polarized X-ray beams
Xiao, H. L.;
Hajdas, W.;
Socha, P.;
Marcinkowski, R.;
Wu, B. B.;
Bao, T. W.;
Chai, J. Y.;
Dong, Y. W.;
Kong, M. N.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Xiong, S. L.;
Zhang, J.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Cadoux, F.;
Pohl, M.;
Wu, X.;
Batsch, T.;
Rybka, D.;
Rutczynska, A.;
Szabelski, J.;
Zwolinska, A.;
Gauvin, N.;
Produit, N.;
Bernasconi, T.
Submitted: 2017-04-20, last modified: 2017-04-24
POLAR is space-borne detector designed for a precise measurement of gamma-ray
polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50
keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$
40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we
performed a series of tests of the POLAR flight model with 100\% polarized
x-rays beams at the European Synchrotron Radiation Facility beam-line ID11
aming to study thresholds, crosstalk between channels and responses of POLAR
flight model to polarized X-ray beams. In this paper we present the data
analysis method and some analysis results. According the results, POLAR FM has
good polarimetric capabilities.
[9]
oai:arXiv.org:1703.04210 [pdf] - 1547762
Gain factor and parameter settings optimization of the new gamma-ray
burst polarimeter POLAR
Zhang, X. F.;
Hajdas, W.;
Xiao, H. L.;
Wen, X.;
Wu, B. B.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
He, J. J.;
Kole, M.;
Kong, M. N.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rapin, D.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wu, X.;
Xiong, S. L.;
Xu, M.;
Zhang, L.;
Zhang, L. Y.;
Zhang, P.;
Zhang, S. N.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2017-03-12, last modified: 2017-03-14
As a space-borne detector POLAR is designed to conduct hard X-ray
polarization measurements of gamma-ray bursts on the statistically significant
sample of events and with an unprecedented accuracy. During its development
phase a number of tests, calibrations runs and verification measurements were
carried out in order to validate instrument functionality and optimize
operational parameters. In this article we present results on gain optimization
togeter with verification data obtained in the course of broad laboratory and
environmental tests. In particular we focus on exposures to the $^{137}$Cs
radioactive source and determination of the gain dependence on the high voltage
for all 1600 detection channels of the polarimeter. Performance of the
instrument is described in detail with respect to the dynamic range, energy
resolution and temperature dependence. Gain optimization algorithms and
response non-uniformity studies are also broadly discussed. Results presented
below constitute important parts for development of the POLAR calibration and
operation database.
[10]
oai:arXiv.org:1701.04178 [pdf] - 1534584
Singlet S-wave superfluidity of proton in neutron star matter
Submitted: 2017-01-16
The possible $^{1}S_{0}$ protonic superfluidity is investigated in neutron
star matter, and the corresponding energy gap as a function of baryonic density
is calculated on the basis of BCS gap equation. We have discussed particularly
the influence of hyperon degrees of freedom on $^{1}S_{0}$ protonic
superfluidity. It is found that the appearance of hyperons leads to a slight
decrease of $^{1}S_{0}$ protonic pairing energy gap in most density range of
existing $^{1}S_{0}$ protonic superfluidity. However, when the baryonic density
$\rho_{B}>$0.377 (or 0.409) fm${^{-3}}$ for TM1 (or TMA) parameter set,
$^{1}S_{0}$ protonic pairing energy gap is significantly larger than the
corresponding values without hyperons. And the baryonic density range of
existing $^{1}S_{0}$ protonic superfluidity is widen due to the appearance of
hyperons. In our results, the hyperons not only change the EOS and bulk
properties but also change the size and baryon density range of $^{1}S_{0}$
protonic superfluidity in neutron star matter.
[11]
oai:arXiv.org:1612.04098 [pdf] - 1533322
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB
Polarimeter
Kole, M.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cadoux, F.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Hajdas, W.;
He, J. J.;
Kong, M. N.;
Kong, S. W.;
Lechanoine-Leluc, C.;
Li, L.;
Li, Z. H.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. J.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Xiong, S. L.;
Xu, H. H.;
Xu, M.;
Zhang, J.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2016-12-13
Gamma-ray polarimetry is a new powerful tool to study the processes
responsible for the emission from astrophysical sources and the environments in
which this emission takes place. Few successful polarimetric measurements have
however been performed thus far in the gamma-ray energy band due to the
difficulties involved. POLAR is a dedicated polarimeter designed to perform
high precision measurements of the polarization of the emission from gamma-ray
burst in the 50-500 keV energy range. This new polarimeter is expected to
detect approximately 50 gamma-ray bursts per year while performing high
precision polarization measurements on approximately 10 bursts per year. The
instrument was launched into lower earth orbit as part of the second Chinese
space lab, the Tiangong-2, on September 15th 2016 and has been taking data
successfully since being switched on one week after. The instrument uses a
segmented scintillator array consisting of 1600 plastic scintillator bars, read
out by 25 flat-panel multi-anode photomultipliers, to measure the Compton
scattering angles of incoming photons. The small segmentation and relatively
large uniform effective area allow the instrument to measure the polarization
of a large number of transient events, such as gamma-ray bursts, with an
unprecedented precision during its two year life-time. The final flight model
underwent detailed calibration prior to launch as well as intensive space
qualification tests, a summary of which will be presented in this paper. The
instrument design will be discussed first followed by an overview of the
on-ground tests, finally the in-orbit behavior as measured during the first
weeks of the mission will be presented.
[12]
oai:arXiv.org:1512.02784 [pdf] - 1515698
Calibration of Gamma-ray Burst Polarimeter POLAR
Xiao, H. L.;
Hajdas, W.;
Bao, T. W.;
Batsch, T.;
Bernasconi, T.;
Cernuda, I.;
Chai, J. Y.;
Dong, Y. W.;
Gauvin, N.;
Kole, M.;
Kong, M. N.;
Kong, S. W.;
Li, L.;
Liu, J. T.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Produit, N.;
Rapin, D.;
Rutczynska, A.;
Rybka, D.;
Shi, H. L.;
Song, L. M.;
Sun, J. C.;
Szabelski, J.;
Wu, B. B.;
Wang, R. J.;
Wen, X.;
Xu, H. H.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zwolinska, A.
Submitted: 2015-12-09
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which
might be associated with creation of black holes. Magnetic field structure and
burst dynamics may influence polarization of the emitted gamma-rays. Precise
polarization detection can be an ultimate tool to unveil the true GRB
mechanism. POLAR is a space-borne Compton scattering detector for precise
measurements of the GRB polarization. It consists of a 40$\times$40 array of
plastic scintillator bars read out by 25 multi-anode PMTs (MaPMTs). It is
scheduled to be launched into space in 2016 onboard of the Chinese space
laboratory TG2. We present a dedicated methodology for POLAR calibration and
some calibration results based on the combined use of the laboratory
radioactive sources and polarized X-ray beams from the European Synchrotron
Radiation Facility. They include calibration of the energy response,
computation of the energy conversion factor vs. high voltage as well as
determination of the threshold values, crosstalk contributions and polarization
modulation factors.