Normalized to: Asakura, K.
[1]
oai:arXiv.org:1906.00171 [pdf] - 1893553
Radiation hardness of a p-channel notch CCD developed for the X-ray CCD
camera onboard the XRISM satellite
Kanemaru, Yoshiaki;
Sato, Jin;
Mori, Koji;
Nakajima, Hiroshi;
Nishioka, Yusuke;
Takeda, Ayaki;
Hayashida, Kiyoshi;
Matsumoto, Hironori;
Iwagaki, Junichi;
Okazaki, Koki;
Asakura, Kazunori;
Yoneyama, Tomokage;
Uchida, Hiroyuki;
Okon, Hiromichi;
Tanaka, Takaaki;
Tsuru, Takeshi G.;
Tomida, Hiroshi;
Shimoi, Takeo;
Kohmura, Takayoshi;
Hagino, Kouichi;
Murakami, Hiroshi;
Kobayashi, Shogo B.;
Yamauchi, Makoto;
Hatsukade, Isamu;
Nobukawa, Masayoshi;
Nobukawa, Kumiko K.;
Hiraga, Junko S.;
Uchiyama, Hideki;
Yamaoka, Kazutaka;
Ozaki, Masanobu;
Dotani, Tadayasu;
Tsunemi, Hiroshi;
Hamano, Tsuyoshi
Submitted: 2019-06-01
We report the radiation hardness of a p-channel CCD developed for the X-ray
CCD camera onboard the XRISM satellite. This CCD has basically the same
characteristics as the one used in the previous Hitomi satellite, but newly
employs a notch structure of potential for signal charges by increasing the
implant concentration in the channel. The new device was exposed up to
approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The
charge transfer inefficiency was estimated as a function of proton fluence with
an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also
examined for comparison. The result shows that the notch device has a
significantly higher radiation hardness than those without the notch structure
including the device adopted for Hitomi. This proves that the new CCD is
radiation tolerant for space applications with a sufficient margin.
[2]
oai:arXiv.org:1906.00012 [pdf] - 1893538
X-ray imaging polarimetry with a 2.5-$\mathrm{\mu}$m pixel CMOS sensor
for visible light at room temperature
Asakura, Kazunori;
Hayashida, Kiyoshi;
Hanasaka, Takashi;
Kawabata, Tomoki;
Yoneyama, Tomokage;
Okazaki, Koki;
Ide, Shuntaro;
Noda, Hirofumi;
Matsumoto, Hironori;
Tsunemi, Hiroshi;
Awaki, Hisamitsu;
Nakajima, Hiroshi
Submitted: 2019-05-31
X-ray polarimetry in astronomy has not been exploited well, despite its
importance. The recent innovation of instruments is changing this situation. We
focus on a complementary MOS (CMOS) pixel detector with small pixel size and
employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we
employ is developed by GPixel Inc., and has a pixel size of 2.5 $\mathrm{\mu}$m
$\times$ 2.5 $\mathrm{\mu}$m. Although it is designed for visible light, we
succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM)
at 5.9 keV at room temperature and the atmospheric condition. We measure the
x-ray detection efficiency and polarimetry sensitivity by irradiating polarized
monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility
in Japan. We obtain modulation factors of 7.63% $\pm$ 0.07% and 15.5% $\pm$
0.4% at 12.4 keV and 24.8 keV, respectively. It demonstrates that this sensor
can be used as an x-ray imaging spectrometer and polarimeter with the highest
spatial resolution ever tested.
[3]
oai:arXiv.org:1506.01175 [pdf] - 1358787
KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
Asakura, K.;
Gando, A.;
Gando, Y.;
Hachiya, T.;
Hayashida, S.;
Ikeda, H.;
Inoue, K.;
Ishidoshiro, K.;
Ishikawa, T.;
Ishio, S.;
Koga, M.;
Matsuda, S.;
Mitsui, T.;
Motoki, D.;
Nakamura, K.;
Obara, S.;
Oura, T.;
Shimizu, I.;
Shirahata, Y.;
Shirai, J.;
Suzuki, A.;
Tachibana, H.;
Tamae, K.;
Ueshima, K.;
Watanabe, H.;
Xu, B. D.;
Kozlov, A.;
Takemoto, Y.;
Yoshida, S.;
Fushimi, K.;
Piepke, A.;
Banks, T. I.;
Berger, B. E.;
Fujikawa, B. K.;
O'Donnell, T.;
Learned, J. G.;
Maricic, J.;
Matsuno, S.;
Sakai, M.;
Winslow, L. A.;
Efremenko, Y.;
Karwowski, H. J.;
Markoff, D. M.;
Tornow, W.;
Detwiler, J. A.;
Enomoto, S.;
Decowski, M. P.
Submitted: 2015-06-03, last modified: 2016-01-22
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the
production of neutrino-antineutrino pairs through various processes becomes the
dominant stellar cooling mechanism. As the star evolves, the energy of these
neutrinos increases and in the days preceding the supernova a significant
fraction of emitted electron anti-neutrinos exceeds the energy threshold for
inverse beta decay on free hydrogen. This is the golden channel for liquid
scintillator detectors because the coincidence signature allows for significant
reductions in background signals. We find that the kiloton-scale liquid
scintillator detector KamLAND can detect these pre-supernova neutrinos from a
star with a mass of $25~M_{\sun}$ at a distance less than 690~pc with 3$\sigma$
significance before the supernova. This limit is dependent on the neutrino mass
ordering and background levels. KamLAND takes data continuously and can provide
a supernova alert to the community.
[4]
oai:arXiv.org:1503.02137 [pdf] - 1175829
Study of electron anti-neutrinos associated with gamma-ray bursts using
KamLAND
Asakura, K.;
Gando, A.;
Gando, Y.;
Hachiya, T.;
Hayashida, S.;
Ikeda, H.;
Inoue, K.;
Ishidoshiro, K.;
Ishikawa, T.;
Ishio, S.;
Koga, M.;
Matsuda, S.;
Mitsui, T.;
Motoki, D.;
Nakamura, K.;
Obara, S.;
Oki, Y.;
Oura, T.;
Shimizu, I.;
Shirahata, Y.;
Shirai, J.;
Suzuki, A.;
Tachibana, H.;
Tamae, K.;
Ueshima, K.;
Watanabe, H.;
Xu, B. D.;
Yoshida, H.;
Kozlov, A.;
Takemoto, Y.;
Yoshida, S.;
Fushimi, K.;
Piepke, A.;
Banks, T. I.;
Berger, B. E.;
O'Donnell, T.;
Fujikawa, B. K.;
Maricic, J.;
Learned, J. G.;
Sakai, M.;
Winslow, L. A.;
Efremenko, Y.;
Karwowski, H. J.;
Markoff, D. M.;
Tornow, W.;
Detwiler, J. A.;
Enomoto, S.;
Decowski, M. P.
Submitted: 2015-03-07, last modified: 2015-06-15
We search for electron anti-neutrinos ($\overline{\nu}_e$) from long and
short-duration gamma-ray bursts~(GRBs) using data taken by the KamLAND detector
from August 2002 to June 2013. No statistically significant excess over the
background level is found. We place the tightest upper limits on
$\overline{\nu}_e$ fluence from GRBs below 7 MeV and place first constraints on
the relation between $\overline{\nu}_e$ luminosity and effective temperature.