sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

SuperCDMS Collaboration

Normalized to: SuperCDMS Collaboration.

8 article(s) in total. 181 co-authors, from 1 to 7 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:2005.14067  [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration; Amaral, D. W.; Aralis, T.; Aramaki, T.; Arnquist, I. J.; Azadbakht, E.; Banik, S.; Barker, D.; Bathurst, C.; Bauer, D. A.; Bezerra, L. V. S.; Bhattacharyya, R.; Binder, T.; Bowles, M. A.; Brink, P. L.; Bunker, R.; Cabrera, B.; Calkins, R.; Cameron, R. A.; Cartaro, C.; Cerdeño, D. G.; Chang, Y. -Y.; Chen, R.; Chott, N.; Cooley, J.; Coombes, H.; Corbett, J.; Cushman, P.; De Brienne, F.; di Vacri, M. L.; Diamond, M. D.; Fascione, E.; Figueroa-Feliciano, E.; Fink, C. W.; Fouts, K.; Fritts, M.; Gerbier, G.; Germond, R.; Ghaith, M.; Golwala, S. R.; Harris, H. R.; Herbert, N.; Hines, B. A.; Hollister, M. I.; Hong, Z.; Hoppe, E. W.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D.; Jastram, A.; Kelsey, M. H.; Kubik, A.; Kurinsky, N. A.; Lawrence, R. E.; Li, A.; Loer, B.; Asamar, E. Lopez; Lukens, P.; MacDonell, D.; MacFarlane, D. B.; Mahapatra, R.; Mandic, V.; Mast, N.; Mayer, A. J.; Michaud, É. M.; Michielin, E.; Mirabolfathi, N.; Mohanty, B.; Mendoza, J. D. Morales; Nagorny, S.; Nelson, J.; Neog, H.; Novati, V.; Orrell, J. L.; Oser, S. M.; Page, W. A.; Pakarha, P.; Partridge, R.; Podviianiuk, R.; Ponce, F.; Poudel, S.; Pyle, M.; Rau, W.; Reid, E.; Ren, R.; Reynolds, T.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Sattari, A.; Schnee, R. W.; Scorza, S.; Serfass, B.; Sincavage, D. J.; Stanford, C.; Stein, M.; Street, J.; Toback, D.; Underwood, R.; Verma, S.; Villano, A. N.; von Krosigk, B.; Watkins, S. L.; Wills, L.; Wilson, J. S.; Wilson, M. J.; Winchell, J.; Wright, D. H.; Yellin, S.; Young, B. A.; Yu, T. C.; Zhang, E.; Zhang, H. G.; Zhao, X.; Zheng, L.
Comments: 5 pages + title and references, 3 figures and 1 table
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]  oai:arXiv.org:1806.07043  [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Comments: 14 pages, 10 figures, 5 tables. v5 contains the extended data release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]  oai:arXiv.org:1804.10697  [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
[4]  oai:arXiv.org:1808.09098  [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Comments:
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
[5]  oai:arXiv.org:1707.01632  [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
[6]  oai:arXiv.org:1509.02448  [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[7]  oai:arXiv.org:1410.1003  [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Comments: 12 pages, 12 figures, submitted to PRD
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
[8]  oai:arXiv.org:astro-ph/0502435  [pdf] - 554569
The SuperCDMS Experiment
Comments: 10 pages, 2 figures, 2 tables; to appear in proceedings of DARK 2004, the Fifth International Heidelberg Conference on Dark Matter in Astro and Particle Physics
Submitted: 2005-02-21
WIMP-nucleon cross sections in the range 10^{-46} - 10^{-44} cm^2 may be probed by a ton-scale experiment with low energy thresholds and excellent discrimination of backgrounds. Because CDMS ZIP detectors are the most proven means of achieving such good discrimination, we intend to scale CDMS up to a ton detector mass. Development of this experiment, dubbed "SuperCDMS," is discussed. Improved analysis and optimization of the charge collection and athermal phonon sensors should improve surface-background rejection by over two orders of magnitude. Siting the SuperCDMS experiment deep enough to remove the fast neutron background, and reducing radioactive beta contamination near or on the detectors, should sufficiently reduce these otherwise troubling backgrounds. The primary challenge is making the experiment easy enough to build. We discuss methods of improving the detector manufacturability, removing the need for large-scale cryogenic detector testing, and allowing simplified infrastructure by using more sophisticated readout.