sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mancuso, M.

Normalized to: Mancuso, M.

16 article(s) in total. 198 co-authors, from 1 to 13 common article(s). Median position in authors list is 22,5.

[1]  oai:arXiv.org:2005.02692  [pdf] - 2090731
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter
Comments:
Submitted: 2020-05-06
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut f\"ur Kristallz\"uchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
[2]  oai:arXiv.org:2004.08121  [pdf] - 2079391
New limits on the resonant absorption of solar axions obtained with a $^{169}$Tm-containing cryogenic detector
Comments: 7 pages, 5 figures
Submitted: 2020-04-17
A search for resonant absorption of solar axions by $^{169}$Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for significant improvement of sensitivity in comparison with previous $^{169}$Tm based experiments. The measurements performed with $8.18$ g crystal during $6.6$ days exposure yielded the following limits on axion couplings: $|g_{A\gamma} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and $|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.
[3]  oai:arXiv.org:1905.07335  [pdf] - 2075555
Description of CRESST-III Data
Comments: Added appendix with information for better reproducibility
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.
[4]  oai:arXiv.org:1902.07587  [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li
Comments:
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[5]  oai:arXiv.org:1908.06755  [pdf] - 2001880
Geant4-based electromagnetic background model for the CRESST dark matter experiment
Comments: 19 pages, 12 figures
Submitted: 2019-08-19
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.
[6]  oai:arXiv.org:1905.12952  [pdf] - 2025534
A Test of Bolometric Properties of Tm-containing Crystals as a Perspective Detector for the Solar Axion Search
Comments: 9 pages, 6 figures, 3 tables
Submitted: 2019-05-30
The $^{169}$Tm nuclide has first nuclear level at 8.41 keV with magnetic type transition to the ground state and, therefore, can be used as a target nucleus for the search of resonant absorption of solar axions. We plan to use a Tm-containing crystal of a garnet family Tm$_3$Al$_5$O$_{12}$ as a bolometric detector in order to search for the excitation of the first nuclear level of $^{169}$Tm via the resonant absorption of solar axions. With this perspective in mind, a sample of the Tm$_3$Al$_5$O$_{12}$ crystal was grown and tested for its bolometric and optical properties. Measurements of chemical and/or radioactive contaminations were performed as well. In this paper we present the test results and estimate the requirements for a future low-background experimental setup.
[7]  oai:arXiv.org:1904.00498  [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
Comments: 9 pages, 9 figures
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this manuscript we describe the analysis of one detector operated in the first run of CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV. This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at ~15mK. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as 160MeV/c$^2$.
[8]  oai:arXiv.org:1711.07692  [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
Comments: XV International Conference on Topics in Astroparticle and Underground Physics, TAUP2017, submitted to Journal of Physics: Conference Series (JPCS)
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in Italy, searches for dark matter particles via their elastic scattering off nuclei in a target material. The CRESST target consists of scintillating CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon signal and a light signal that is measured by a second cryogenic calorimeter. Since the CRESST-II result in 2015, the experiment is leading the field of direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$, extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized to reach the performance required to further probe the low-mass region with unprecedented sensitivity. In this contribution the achievements of the CRESST-III detectors will be discussed together with preliminary results and perspectives of Phase 1.
[9]  oai:arXiv.org:1711.01482  [pdf] - 2082284
Results of the first NaI scintillating calorimeter prototypes by COSINUS
Comments: XV International Conference on Topics in Astroparticle and Underground Physics, TAUP2017, submitted to Journal of Physics: Conference Series (JPCS)
Submitted: 2017-11-04
Over almost three decades the TAUP conference has seen a remarkable momentum gain in direct dark matter search. An important accelerator were first indications for a modulating signal rate in the DAMA/NaI experiment reported in 1997. Today the presence of an annual modulation, which matches in period and phase the expectation for dark matter, is supported at > 9$\sigma$ confidence. The underlying nature of dark matter, however, is still considered an open and fundamental question of particle physics. No other direct dark matter search could confirm the DAMA claim up to now; moreover, numerous null-results are in clear contradiction under so-called standard assumptions for the dark matter halo and the interaction mechanism of dark with ordinary matter. As both bear a dependence on the target material, resolving this controversial situation will convincingly only be possible with an experiment using sodium iodide (NaI) as target. COSINUS aims to even go a step further by combining NaI with a novel detection approach. COSINUS aims to operate NaI as a cryogenic calorimeter reading scintillation light and phonon/heat signal. Two distinct advantages arise from this approach, a substantially lower energy threshold for nuclear recoils and particle identification on an event-by-event basis. These key benefits will allow COSINUS to clarify a possible nuclear recoil origin of the DAMA signal with comparatively little exposure of O(100kg days) and, thereby, answer a long-standing question of particle physics. Today COSINUS is in R&D phase; in this contribution we show results from the 2nd prototype, albeit the first one of the final foreseen detector design. The key finding of this measurement is that pure, undoped NaI is a truly excellent scintillator at low temperatures: We measure 13.1% of the total deposited energy in the NaI crystal in the form of scintillation light (in the light detector).
[10]  oai:arXiv.org:1711.01285  [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Comments: Contributed to the 13th Patras Workshop on Axions, WIMPs and WISPs, Thessaloniki, May 15 to 19, 2017
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM) using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading limits for the spin-independent DM-nucleon cross section down to DM-particle masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST performed a dedicated search for dark photons (DP) which excludes new parameter space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to $700\,\mathrm{eV/c^2}$. In this contribution we will discuss the latest results based on the previous CRESST-II phase 2 and we will report on the status of the current CRESST-III phase 1: in this stage we have been operating 10 upgraded detectors with $24,\mathrm{g}$ target mass each and enhanced detector performance since summer 2016. The improved detector design in terms of background suppression and reduction of the detection threshold will be discussed with respect to the previous stage. We will conclude with an outlook on the potential of the next stage, CRESST-III phase 2.
[11]  oai:arXiv.org:1707.06749  [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
Comments: 6 pages, 6 figures, v3: ancillary files added, v4: high energy spectrum (0.6-12keV) added to ancillary files
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $\nu$-cleus experiment has achieved an energy threshold of $E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous results and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[12]  oai:arXiv.org:1708.01581  [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Comments: 7 pages, 5 fugures, submitted to EPJ-C
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the framework of the CRESST-II experiment, we developed and successfully tested a novel detector design addressing both challenges. Using a large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber, the signal height recorded in the light channel is improved by a factor 2.5 compared to conventional CRESTT-II detector modules. In combination with a large carrier crystal, a true $4\pi$ veto system is established which allows to tag external background sources.
[13]  oai:arXiv.org:1706.01070  [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter searches
Comments:
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $\gamma$-ray events has been demonstrated using $\gamma$-calibrations with $^{133}$Ba sources leading to a value of $R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $\gamma$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
[14]  oai:arXiv.org:1611.02113  [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Comments: Proceedings, contribution to ICHEP 2016, Chigaco
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open questions of modern physics. A well motivated candidate for dark matter is the so-called WIMP - a weakly interacting massive particle. Recently several theoretically well-motivated models with dark matter candidates in a mass region below the WIMP mass-scale gained also a lot of interest, theoretically and experimentally. The CRESST II experiment located at the Gran Sasso laboratory in Italy is optimised for the detection of the elastic scattering of these low-mass dark matter particles with ordinary matter. We show the results obtained with an improved detector setup with increased radio purity and enhanced background rejection and the results obtained with a dedicated low-threshold analysis of a single conventional detector module. The limit achieved is the most stringent limit achieved for direct dark matter experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the expected performance for new small CRESST-type detectors to be used during the next data taking phase. We conclude with an outlook of the future potential for direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic detectors.
[15]  oai:arXiv.org:1603.05120  [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
Comments: Matches published version
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an illustration the number of observed events in the search for 5 (resp. 20) GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1 (resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times 10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a 41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints of WIMP signals from some recent experiments, thus confirming results obtained with different detection techniques.
[16]  oai:arXiv.org:1307.1488  [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Comments:
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS experiment, located at the Underground Laboratory of Modane, primarily aims at the direct detection of WIMPs using germanium bolometers. It is also sensitive to the low-energy electron recoils that would be induced by solar or dark matter axions. Using a total exposure of up to 448 kg.d, we searched for axion-induced electron recoils down to 2.5 keV within four scenarios involving different hypotheses on the origin and couplings of axions. We set a 95% CL limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in a mass range not fully covered by axion helioscopes. We also constrain the coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the effective axion-nucleon coupling for $^{57}$Fe. Combining these results we fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and $5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.