sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Maekawa, Jun

Normalized to: Maekawa, J.

5 article(s) in total. 84 co-authors, from 1 to 4 common article(s). Median position in authors list is 23,0.

[1]  oai:arXiv.org:2001.05151  [pdf] - 2050374
DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-18 special issue
Submitted: 2020-01-15
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1\sigma=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.
[2]  oai:arXiv.org:1911.02574  [pdf] - 1995513
A new off-point-less observing method for millimeter and submillimeter spectroscopy with a frequency-modulating local oscillator (FMLO)
Comments: 22 pages, 15 figures, 2 tables, accepted for publication in Publications of the Astronomical Society of Japan
Submitted: 2019-11-06
We propose a new observing method for single-dish millimeter and submillimeter spectroscopy using a heterodyne receiver equipped with a frequency-modulating local oscillator (FMLO). Unlike conventional switching methods, which extract astronomical signals by subtracting the reference spectra of off-sources from those of on-sources, the FMLO method does not need to obtain any off-source spectra; rather, it estimates them from the on-source spectra themselves. The principle is a high dump-rate (10 Hz) spectroscopy with radio frequency modulation (FM) achieved by fast sweeping of a local oscillator (LO) of a heterodyne receiver: Because sky emission (i.e., off-source) fluctuates as $1/f$-type and is spectrally correlated, it can be estimated and subtracted from time-series spectra (a timestream) by principal component analysis. Meanwhile astronomical signals remain in the timestream since they are modulated to a higher time-frequency domain. The FMLO method therefore achieves (1) a remarkably high observation efficiency, (2) reduced spectral baseline wiggles, and (3) software-based sideband separation. We developed an FMLO system for the Nobeyama 45-m telescope and a data reduction procedure for it. Frequency modulation was realized by a tunable and programmable first local oscillator. With observations of Galactic sources, we demonstrate that the observation efficiency of the FMLO method is dramatically improved compared to conventional switching methods. Specifically, we find that the time to achieve the same noise level is reduced by a factor of 3.0 in single-pointed observations and by a factor of 1.2 in mapping observations. The FMLO method can be applied to observations of fainter ($\sim$mK) spectral lines and larger ($\sim$deg$^{2}$) mapping. It would offer much more efficient and baseline-stable observations compared to conventional switching methods.
[3]  oai:arXiv.org:1906.10216  [pdf] - 1963690
First light demonstration of the integrated superconducting spectrometer
Comments: Published in Nature Astronomy. SharedIt Link to the full published paper: https://rdcu.be/bM2FN
Submitted: 2019-06-24, last modified: 2019-09-18
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pixels (>$10^2$). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of $F/\Delta F \sim 380$. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$ allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.
[4]  oai:arXiv.org:1206.3840  [pdf] - 1124175
Initial Results from the Nobeyama Molecular Gas Observations of Distant Bright Galaxies
Comments: 4 pages, 1 figure, PASJ Letter Accepted
Submitted: 2012-06-18
We present initial results from the CO survey toward high redshift galaxies using the Nobeyama 45m telescope. Using the new wide bandwidth spectrometer equipped with a two-beam SIS receiver, we have robust new detections of three high redshift (z=1.6-3.4) submillimeter galaxies (SXDF 1100.001, SDP9, and SDP17), one tentative detection (SDSS J160705+533558), and one non-detection (COSMOS-AzTEC1). The galaxies observed during the commissioning phase are sources with known spectroscopic redshifts from previous optical or from wide-band submm spectroscopy. The derived molecular gas mass and line widths from Gaussian fits are ~10^11 Msun and 430-530 km/s, which are consistent with previous CO observations of distant submm galaxies and quasars. The spectrometer that allows a maximum of 32 GHz instantaneous bandwidth will provide new science capabilities at the Nobeyama 45m telescope, allowing us to determine redshifts of bright submm selected galaxies without any prior redshift information.
[5]  oai:arXiv.org:0712.1283  [pdf] - 1000569
On-The-Fly Observing System of the Nobeyama 45-m and ASTE 10-m Telescopes
Comments: 11 pages, 13 figures, accepted for publication in PASJ
Submitted: 2007-12-08
We have developed spectral line On-The-Fly (OTF) observing mode for the Nobeyama Radio Observatory 45-m and the Atacama Submillimeter Telescope Experiment 10-m telescopes. Sets of digital autocorrelation spectrometers are available for OTF with heterodyne receivers mounted on the telescopes, including the focal-plane 5 x 5 array receiver, BEARS, on the 45-m. During OTF observations, the antenna is continuously driven to cover the mapped region rapidly, resulting in high observing efficiency and accuracy. Pointing of the antenna and readouts from the spectrometer are recorded as fast as 0.1 second. In this paper we report improvements made on software and instruments, requirements and optimization of observing parameters, data reduction process, and verification of the system. It is confirmed that, using optimal parameters, the OTF is about twice as efficient as conventional position-switch observing method.