23 article(s) in total. 98 co-authors, from 1 to 41 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:2005.09919  [pdf] - 2098871
Measurement of the Background Activities of a 100Mo-enriched powder sample for AMoRE crystal material using a single high purity germanium detector
Comments: 19 pages, 6 figures
Submitted: 2020-05-20
The Advanced Molybdenum-based Rare process Experiment (AMoRE) searches for neutrino-less double-beta (0{\nu}\b{eta}\b{eta}) decay of 100Mo in enriched molybdate crystals. The AMoRE crystals must have low levels of radioactive contamination to achieve a low rate of background signals with energies near the Q-value of 100Mo 0{\nu}\b{eta}\b{eta} decay. To produce low-activity crystals, radioactive contaminants in the raw materials used to form the crystals must be controlled and quantified. 100EnrMoO3 powder, which is enriched in the 100Mo isotope, is of particular interest as it is the source of 100Mo in the crystals. A high-purity germanium detector having 100% relative efficiency, named CC1, is being operated in the Yangyang underground laboratory. Using CC1, we collected a gamma spectrum from a 1.6 kg 100EnrMoO3 powder sample, enriched to 96.4% in 100Mo. Activities were analyzed for the isotopes 228Ac, 228Th, 226Ra, and 40K, long-lived naturally occurring isotopes that can produce background signals in the region of interest for AMoRE. Activities of both 228Ac and 228Th were < 1.0 mBq/kg at 90% C.L. The activity of 226Ra was measured to be 5.1 {\pm} 0.4 (stat) {\pm} 2.2 (syst) mBq/kg. The 40K activity was found as < 16.4 mBq/kg at 90% C.L.
[2]  oai:arXiv.org:2005.06797  [pdf] - 2095155
Growth and development of pure Li2MoO4 crystals for rare event experiment at CUP
Comments: 10 pages, 3 figures, INSTR'20 conference (Novosibirsk, Feb. 24-28, 2020)
Submitted: 2020-05-14
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0{\nu}\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0{\nu}\b{eta}\b{eta} signal. For the last few years, we have been growing and studying Li2MoO4 crystals in a clean-environment facility to minimize external contamination during the crystal growth. Before growing Li2100MoO4 crystal, we have studied Li2natMoO4 crystal growth by a conventional Czochralski (CZ) grower. We grew a few different kinds of Li2natMO4 crystals using different raw materials in a campaign to minimize impurities. We prepared the fused Al2O3 refractories for the growth of ingots. Purities of the grown crystals were measured with high purity germanium detectors and by inductively coupled plasma mass spectrometry. The results show that the Li2MoO4 crystal has purity levels suitable for rare-event experiments. In this study, we present the growth of Li2MoO4 crystals at CUP and their purities.
[3]  oai:arXiv.org:2004.03463  [pdf] - 2077253
The COSINE-100 Liquid Scintillator Veto System
Comments:
Submitted: 2020-04-05
This paper describes the liquid scintillator veto system for the COSINE-100 dark matter experiment and its performance. The COSINE-100 detector consists of 8 NaI(Tl) crystals immersed in 2,200~L of linear alkylbenzene based liquid scintillator. The liquid scintillator tags between 65 and 75\% of the internal $^{40}$K background in the 2--6~keV energy region. We also describe the background model for the liquid scintillator, which is primarily used to assess its energy calibration and threshold.
[4]  oai:arXiv.org:1907.04963  [pdf] - 1996712
Comparison between DAMA/LIBRA and COSINE-100 in the light of Quenching Factors
Comments: Accepted in JCAP
Submitted: 2019-07-10, last modified: 2019-10-23
There is a long standing debate about whether or not the annual modulation signal reported by the DAMA/LIBRA collaboration is induced by Weakly Interacting Massive Particles~(WIMP) in the galaxy's dark matter halo scattering from nuclides in their NaI(Tl) crystal target/detector. This is because regions of WIMP-mass vs. WIMP-nucleon cross-section parameter space that can accommodate the DAMA/LIBRA-phase1 modulation signal in the context of the standard WIMP dark matter galactic halo and isospin-conserving~(canonical), spin-independent~(SI) WIMP-nucleon interactions have been excluded by many of other dark matter search experiments including COSINE-100, which uses the same NaI(Tl) target/detector material. Moreover, the recently released DAMA/LIBRA-phase2 results are inconsistent with an interpretation as WIMP-nuclide scattering via the canonical SI interaction and prefer, instead, isospin-violating or spin-dependent interactions. Dark matter interpretations of the DAMA/LIBRA signal are sensitive to the NaI(Tl) scintillation efficiency for nuclear recoils, which is characterized by so-called quenching factors~(QF), and the QF values used in previous studies differ significantly from recently reported measurements, which may have led to incorrect interpretations of the DAMA/LIBRA signal. In this article, the compatibility of the DAMA/LIBRA and COSINE-100 results, in light of the new QF measurements is examined for different possible types of WIMP-nucleon interactions. The resulting allowed parameter space regions associated with the DAMA/LIBRA signal are explicitly compared with 90\% confidence level upper limits from the initial 59.5~day COSINE-100 exposure. With the newly measured QF values, the allowed 3$\sigma$ regions from the DAMA/LIBRA data are still generally excluded by the COSINE-100 data.
[5]  oai:arXiv.org:1905.12861  [pdf] - 1975280
Study of cosmogenic radionuclides in the COSINE-100 NaI(Tl) detectors
Comments:
Submitted: 2019-05-30, last modified: 2019-09-15
COSINE-100 is a direct detection dark matter search experiment that uses a 106 kg array of eight NaI(Tl) crystals that are kept underground at the Yangyang Underground Laboratory to avoid cosmogenic activation of radioisotopes by cosmic rays. Even though the cosmogenic activity is declining with time, there are still significant background rates from the remnant nuclides. In this paper, we report measurements of cosmogenic isotope contaminations with less than one year half-lives that are based on extrapolations of the time dependent activities of their characteristic energy peaks to activity rates at the time the crystals were deployed underground. For longer-lived $^{109}$Cd ($T_{1/2}=1.6$ y) and $^{22}$Na ($T_{1/2}=2.6$ y), we investigate time correlations of characteristic $\gamma$/X-ray peaks. The inferred sea-level production rates are compared with caluclations based on the ACTIVIA and MENDL-2 model calculations and experimental data. For $^{3}$H, which has a long, 12.3 year half-life, we evaluated the activity levels from the exposure times and determined a cosmogenic activation rate that is consistent with other measurements.
[6]  oai:arXiv.org:1903.10098  [pdf] - 1922966
Search for a Dark Matter-Induced Annual Modulation Signal in NaI(Tl) with the COSINE-100 Experiment
Comments: 6 pages, 5 figures, revised version as published in PRL
Submitted: 2019-03-24, last modified: 2019-07-25
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7 kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2--6 keV energy region of interest. Using a $\chi$-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092$\pm$0.0067 cpd/kg/keV and 127.2$\pm$45 d, respectively.
[7]  oai:arXiv.org:1904.06860  [pdf] - 1920889
A search for solar axion induced signals with COSINE-100
Comments: 7 pages, 8 figures
Submitted: 2019-04-15, last modified: 2019-07-10
We present results from a search for solar axions with the COSINE-100 experiment. We find no evidence of solar axion events from a data-set of 6,303.9 kg$\cdot$days exposure and set a 90\,\% confidence level upper limit on the axion-electron coupling, $g_{ae}$, at 1.70~$\times$~$10^{-11}$ for an axion mass less than 1\,keV/c$^2$. This limit excludes QCD axions heavier than 0.59\,eV/c$^2$ in the DFSZ model and 168.1\,eV/c$^2$ in the KSVZ model.
[8]  oai:arXiv.org:1904.00128  [pdf] - 1908653
COSINE-100 and DAMA/LIBRA-phase2 in WIMP effective models
Comments: 22 pages, 6 figures, 5 tables. Updated to published version
Submitted: 2019-03-29, last modified: 2019-06-30
Assuming a standard Maxwellian for the WIMP velocity distribution, we obtain the bounds from null WIMP search results of 59.5 days of COSINE-100 data on the DAMA/LIBRA-phase2 modulation effect within the context of the non-relativistic effective theory of WIMP-nucleus scattering. Here, we systematically assume that one of the effective operators allowed by Galilean invariance dominates in the effective Hamiltonian of a spin-1/2 dark matter (DM) particle. We find that, although DAMA/LIBRA and COSINE-100 use the same sodium-iodide target, the comparison of the two results still depends on the particle-physics model. This is mainly due to two reasons: i) the WIMP signal spectral shape; ii) the expected modulation fractions, when the upper bound on the time-averaged rate in COSINE-100 is converted into a constraint on the annual modulation component in DAMA/LIBRA. We find that the latter effect is the dominant one. For several effective operators the expected modulation fractions are larger than in the standard spin-independent or spin-dependent interaction cases. As a consequence, compatibility between the modulation effect observed in DAMA/LIBRA and the null result from COSINE-100 is still possible for several non-relativistic operators. At low WIMP masses such relatively high values of the modulation fractions arise because COSINE-100 is mainly sensitive to WIMP-sodium scattering events, due to the higher threshold compared to DAMA/LIBRA. A next COSINE analysis is expected to have a full sensitivity for the 5$\sigma$ region of DAMA/LIBRA.
[9]  oai:arXiv.org:1906.01791  [pdf] - 1895649
An experiment to search for dark matter interactions using sodium iodide detectors
Comments: 26 pages, 9 figures
Submitted: 2019-06-04
Observations of galaxies and primordial radiation suggest that the Universe is made mostly of non-luminous dark matter. Several types of new fundamental particles have been proposed as candidates for dark matter such as weakly interacting massive particles (WIMPs) but no definitive signal has been seen despite concerted efforts by many collaborations. One exception is the much-debated claim by the DAMA collaboration of a statistically significant annual modulation in the event rate of their experiment with a period and phase consistent with that expected from WIMP dark matter. Several groups have been working to develop experiments with the aim of reproducing DAMA's results using the same target medium. Here we report results from the initial operation of the COSINE-100 experiment. COSINE-100 uses sodium iodide as the target medium-the same medium as DAMA-and is designed to carry out a model-independent test of DAMA's claim. Initial data based on the first 59.5 days indicate that there is no excess of events over the expected background, confirming that DAMA's annual modulation signal is in severe tension with results from other experiments under the assumption of dark matter having spin independent interactions and the Standard Halo Model. COSINE-100 is now taking data to study the presence of dark matter-induced annual modulation in the event rate of the sodium iodide detectors.
[10]  oai:arXiv.org:1811.09344  [pdf] - 1863893
The First Direct Search for Inelastic Boosted Dark Matter with COSINE-100
Comments: 6 pages, 5 figures
Submitted: 2018-11-22, last modified: 2019-01-30
A search for inelastic boosted dark matter (iBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-positron pair in coincidence with the initially scattered electron as a signature for an iBDM interaction. No excess over the predicted background event rate is observed. Therefore, we present limits on iBDM interactions under various hypotheses, one of which allows us to explore an area of the experimental search for iBDM using a terrestrial detector.
[11]  oai:arXiv.org:1806.09788  [pdf] - 1764379
The COSINE-100 Data Acquisition System
Comments:
Submitted: 2018-06-26
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
[12]  oai:arXiv.org:1804.05167  [pdf] - 1709418
Background model for the NaI(Tl) crystals in COSINE-100
Comments:
Submitted: 2018-04-14, last modified: 2018-06-11
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be $^{210}$Pb and $^3$H.
[13]  oai:arXiv.org:1710.05299  [pdf] - 1648653
Initial Performance of the COSINE-100 Experiment
Comments: 19 pages, 25 figures, EPJC accepted
Submitted: 2017-10-15, last modified: 2018-02-11
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
[14]  oai:arXiv.org:1712.02011  [pdf] - 1648729
Muon detector for the COSINE-100 experiment
Comments: 11 pages, 19 figures
Submitted: 2017-12-05
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
[15]  oai:arXiv.org:1604.01825  [pdf] - 1411474
Search for solar axions with CsI(Tl) crystal detectors
Comments: 9 pages, 6 figures
Submitted: 2016-04-06, last modified: 2016-05-23
The results of a search for solar axions from the Korea Invisible Mass Search (KIMS) experiment at the Yangyang Underground Laboratory are presented. Low-energy electron-recoil events would be produced by conversion of solar axions into electrons via the axio-electric effect in CsI(Tl) crystals. Using data from an exposure of 34,596 $\rm kg \cdot days$, we set a 90 \% confidence level upper limit on the axion-electron coupling, $g_{ae}$, of $1.39 \times 10^{-11}$ for an axion mass less than 1 keV/$\rm c^2$. This limit is lower than the indirect solar neutrino bound, and fully excludes QCD axions heavier than 0.48 eV/$\rm c^2$ and 140.9 eV/$\rm c^2$ for the DFSZ and KSVZ models respectively.
[16]  oai:arXiv.org:1510.04519  [pdf] - 1375985
Understanding internal backgrounds of NaI(Tl) crystals toward a 200~kg array for the KIMS-NaI experiment
Comments: 9 pages, 7 figures, EPJC
Submitted: 2015-10-15, last modified: 2016-03-17
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. With experience built on the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200~kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRA's annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contaminations of radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1~count/day/keV/kg for recoil energies around 2~keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7$\sigma$ test of the DAMA/LIBRA signature would be possible with a 600~kg$\cdot$year exposure with this system.
[17]  oai:arXiv.org:1503.05253  [pdf] - 1266895
Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal
Comments: 11pages
Submitted: 2015-03-17, last modified: 2015-08-25
We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton scattered 662 keV $\gamma$-rays from a $^{137}$Cs source. The measured pulse-shape discrimination (PSD) power of the NaI(Tl) crystal is found to be significantly improved because of the high light output of the NaI(Tl) detector. We quantify the PSD power with a quality factor and estimate the sensitivity to the interaction rate for weakly interacting massive particles (WIMPs) with nucleons, and the result is compared with the annual modulation amplitude observed by the DAMA/LIBRA experiment. The sensitivity to spin-independent WIMP-nucleon interactions based on 100 kg$\cdot$year of data from NaI detectors is estimated with simulated experiments, using the standard halo model.
[18]  oai:arXiv.org:1502.03800  [pdf] - 934951
Measurement of the quenching and channeling effects in a CsI crystal used for a WIMP search
Comments:
Submitted: 2015-02-12
We have studied channeling effects in a Cesium Iodide (CsI) crystal that is similar in composition to the ones being used in a search for Weakly Interacting Massive Particles (WIMPs) dark matter candidates, and measured its energy-dependent quenching factor, the relative scintillation yield for electron and nuclear recoils. The experimental results are reproduced with a GEANT4 simulation that includes a model of the scintillation efficiency as a function of electronic stopping power. We present the measured and simulated quenching factors and the estimated effects of channeling.
[19]  oai:arXiv.org:1409.0948  [pdf] - 898652
Neutron calibration facility with an Am-Be source for pulse shape discrimination measurement of CsI(Tl) crystals
Comments: Accepted in JINST
Submitted: 2014-09-03, last modified: 2014-11-05
We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to nuclear recoils induced by neutrons from the Am-Be source and comparing them with the response to electron recoils produced by Compton scattering of 662-keV $\gamma$-rays from a $^{137}$Cs source. The measured results on pulse shape discrimination (PSD) between nuclear- and electron-recoil events are quantified in terms of quality factors. A comparison with similar result from a neutron reactor demonstrate the feasibility of performing calibrations of PSD measurements using neutrons from a Am-Be source.
[20]  oai:arXiv.org:1407.1586  [pdf] - 893680
Tests on NaI(Tl) crystals for WIMP search at the Yangyang Underground Laboratory
Comments: 12 pages, 16 figures
Submitted: 2014-07-07, last modified: 2014-11-05
Among the direct search experiments for WIMP dark matter, the DAMA experiment observed an annual modulation signal interpreted as WIMP interactions with 9.2$\sigma$ significance. However, this result is contradictory with other direct search experiments reporting null signals in the same parameter space allowed by the DAMA observation, necessitating clarification of the origin of the modulation signal observed using the NaI(Tl) crystals of the DAMA experiment independently. Here, we report the first results of NaI(Tl) crystal measurement at the Yangyang Underground Laboratory to grow ultra-low-background NaI(Tl) crystal detectors.
[21]  oai:arXiv.org:1404.3443  [pdf] - 878004
Search for Low-Mass Dark Matter with CsI(Tl) Crystal Detectors
Comments: 6pages, 5 figures
Submitted: 2014-04-13, last modified: 2014-10-07
We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS) experiment. With a total data exposure of 24,324.3kg$\cdot$days,we search for WIMP interaction signals produced by nuclei recoiling from WIMP-nuclear elastic scattering with visible energies between 2 and 4keV. The observed energy distribution of candidate events is consistent with null signals, and upper limits of the WIMP-proton spin-independent interaction are set with a 90% confidence level. The observed limit rejects most of the low mass region of parameter space favored by the DAMA annual modulation signal.
[22]  oai:arXiv.org:0704.0423  [pdf] - 166645
Limits on WIMP-nucleon interactions with CsI(Tl) crystal detectors
Comments: 11 pages, 6 figures
Submitted: 2007-04-03, last modified: 2007-08-14
The Korea Invisible Mass Search(KIMS) experiment presents new limits on WIMP-nucleon cross section using the data from an exposure of 3409 kgd taken with low background CsI(Tl) crystals at Yangyang underground laboratory. The most stringent limit on the spin dependent interaction for pure proton case is obtained. The DAMA signal region for both spin independent and spin dependent interactions for the WIMP mass higher than 20 GeV/c^2are excluded by the single experiment with crystal scintillators.
[23]  oai:arXiv.org:astro-ph/0509080  [pdf] - 75662
First limit on WIMP cross section with low background CsI(Tl) crystal detector
Comments: 16 pages, 9 figures, submitted to Physics Letters B
Submitted: 2005-09-05, last modified: 2005-12-05
The Korea Invisible Mass Search (KIMS) collaboration has been carrying out WIMP search experiment with CsI(T$\ell$)crystal detectors at the YanYang Underground Laboratory. A successful reduction of the internal background of the crystal is done and a good pulse shape discrimination is achieved. We report the first result on WIMP search obtained with 237 kg$\cdot$days data using one full-size CsI(T$\ell$)crystal of 6.6 kg mass.