sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Hagmann, C.

Normalized to: Hagmann, C.

21 article(s) in total. 74 co-authors, from 1 to 13 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1402.2037  [pdf] - 817676
First measurement of the ionization yield of nuclear recoils in liquid argon
Comments: 4 pages, 4 figures
Submitted: 2014-02-10, last modified: 2014-05-01
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino nucleus scattering. A significant dependence of $Q_y$ on the applied electric field is observed and explained in the context of ion recombination.
[2]  oai:arXiv.org:1301.4290  [pdf] - 696057
First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber
Comments:
Submitted: 2013-01-17, last modified: 2013-07-19
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of Ar-37, respectively. The Ar-37 source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed Fe-55 x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.
[3]  oai:arXiv.org:1109.4128  [pdf] - 1084216
A search for non-virialized axionic dark matter
Comments: 4 pages, 4 figures, Accepted to be published in PRD Rapid Communications
Submitted: 2011-09-19, last modified: 2011-11-17
Cold dark matter in the Milky Way halo may have structure defined by flows with low velocity dispersion. The Axion Dark Matter eXperiment high resolution channel is especially sensitive to axions in such low velocity dispersion flows. Results from a combined power spectra analysis of the high resolution channel axion search are presented along with a discussion of the assumptions underlying such an analysis. We exclude KSVZ axion dark matter densities of {\rho} > 0.2 GeV/cm^3 and DFSZ densities of {\rho} > 1.4 GeV/cm^3 over a mass range of m_a = 3.3{\mu}eV to 3.69{\mu}eV for models having velocity dispersions of {\Delta}{\beta} < 3x10^-6.
[4]  oai:arXiv.org:1105.4203  [pdf] - 966847
Design and performance of the ADMX SQUID-based microwave receiver
Comments: 8 pages, 12 figures, Submitted to Nuclear Inst. and Methods in Physics Research, A
Submitted: 2011-05-20
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as well as the analysis of narrow band microwave signals. We demonstrate the sustained use of a SQUID amplifier operating between 812 and 860 MHz with a noise temperature of 1 K. The receiver has a noise equivalent power of 1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of 1.8x10^3 s.
[5]  oai:arXiv.org:1007.3766  [pdf] - 250071
A Search for Hidden Sector Photons with ADMX
Comments: 4 pages, 4 figures, published in PRL
Submitted: 2010-07-21, last modified: 2010-10-28
Hidden U(1) gauge symmetries are common to many extensions of the Standard Model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with Standard Model photons, providing a means for electromagnetic power to pass through conducting barriers. The ADMX detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings {\chi} > 3.48x10-8 for masses less than 3 {\mu}eV. This limit represents an improvement of more than two orders of magnitude in sensitivity relative to previous cavity experiments.
[6]  oai:arXiv.org:1004.5160  [pdf] - 903114
A Search for Scalar Chameleons with ADMX
Comments: 4 pages, 3 figures
Submitted: 2010-04-28
Scalar fields with a "chameleon" property, in which the effective particle mass is a function of its local environment, are common to many theories beyond the standard model and could be responsible for dark energy. If these fields couple weakly to the photon, they could be detectable through the "afterglow" effect of photon-chameleon-photon transitions. The ADMX experiment was used in the first chameleon search with a microwave cavity to set a new limit on scalar chameleon-photon coupling excluding values between 2*10^9 and 5*10^14 for effective chameleon masses between 1.9510 and 1.9525 micro-eV.
[7]  oai:arXiv.org:0910.5914  [pdf] - 142256
A SQUID-based microwave cavity search for dark-matter axions
Comments: 4 pages, 5 figures, submitted to PRL
Submitted: 2009-10-30
Axions in the micro eV mass range are a plausible cold dark matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. The first result from such an axion search using a superconducting first-stage amplifier (SQUID) is reported. The SQUID amplifier, replacing a conventional GaAs field-effect transistor amplifier, successfully reached axion-photon coupling sensitivity in the band set by present axion models and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.
[8]  oai:arXiv.org:astro-ph/0603108  [pdf] - 80317
A High Resolution Search for Dark-Matter Axions
Comments: 11 pages, 10 figures, 2 tables
Submitted: 2006-03-04
We have performed a high resolution search for galactic halo axions in cold flows using a microwave cavity detector. The analysis procedure and other details of this search are described. No axion signal was found in the mass range 1.98-2.17 micro-eV. We place upper limits on the density of axions in local discrete flows based on this result.
[9]  oai:arXiv.org:astro-ph/0505237  [pdf] - 73007
Results of a Search for Cold Flows of Dark Matter Axions
Comments: 5 pages, 3 figures
Submitted: 2005-05-11
Theoretical arguments predict that the distribution of cold dark matter in spiral galaxies has peaks in velocity space associated with non-thermalized flows of dark matter particles. We searched for the corresponding peaks in the spectrum of microwave photons from axion to photon conversion in the cavity detector of dark matter axions. We found none and place limits on the density of any local flow of axions as a function of the flow velocity dispersion over the axion mass range 1.98 to 2.17 $\mu$eV.
[10]  oai:arXiv.org:astro-ph/0407575  [pdf] - 66417
The XENON Dark Matter Search Experiment
Comments: 9 pages, 8 figures, appear in the Proceeding of 6th UCLA Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.
[11]  oai:arXiv.org:astro-ph/0310042  [pdf] - 59705
An Improved RF Cavity Search for Halo Axions
Comments: 5 pages, submitted to Physical Review D rapid communications
Submitted: 2003-10-01
The axion is a hypothetical elementary particle and cold dark matter candidate. In this RF cavity experiment, halo axions entering a resonant cavity immersed in a static magnetic field convert into microwave photons, with the resulting photons detected by a low-noise receiver. The ADMX Collaboration presents new limits on the axion-to-photon coupling and local axion dark matter halo mass density from a RF cavity axion search in the axion mass range 1.9-2.3 microeV, broadening the search range to 1.9-3.3 microeV. In addition, we report first results from an improved analysis technique.
[12]  oai:arXiv.org:astro-ph/0104200  [pdf] - 41939
Experimental Constraints on the Axion Dark Matter Halo Density
Comments: 10 pages (includes 3 figures)
Submitted: 2001-04-11, last modified: 2002-06-12
Most of the mass of the Milky Way galaxy is contributed by its halo, presumably in the form of non-interacting cold dark matter. The axion is a compelling cold dark matter candidate. We report results from a search which probes the local galactic halo axion density using the Sikivie RF cavity technique. Candidates over the frequency range 550$$ $\le$ f $\le$$$ 810 MHz (2.3$$ $\mu$eV $\le$$$ m$_{a}$ $\le$ 3.4 $\mu$eV) were investigated. The absence of a signal suggests that KSVZ axions contribute no more than 0.45 GeV/cm$^3$ of mass density to the local dark matter halo over this mass range.
[13]  oai:arXiv.org:hep-ph/0012361  [pdf] - 113697
Axion Radiation from Strings
Comments: 29 pages, 10 figures
Submitted: 2000-12-28
This paper revisits the problem of the string decay contribution to the axion cosmological energy density. We show that this contribution is proportional to the average relative increase when axion strings decay of a certain quantity $N_{\rm ax}$ which we define. We carry out numerical simulations of the evolution and decay of circular and non-circular string loops, of bent strings with ends held fixed, and of vortex-antivortex pairs in two dimensions. In the case of string loops and of vortex-antivortex pairs, $N_{\rm ax}$ decreases by approximately 20%. In the case of bent strings, $N_{\rm ax}$ remains constant or increases slightly. Our results imply that the string decay contribution to the axion energy density is of the same order of magnitude as the well-understood contribution from vacuum realignment.
[14]  oai:arXiv.org:astro-ph/9905258  [pdf] - 106584
Cosmic neutrinos and their detection
Comments: 6 pages, 3 figures, Proceedings of the APS meeting, Division of Particles and Fields, Los Angeles, Jan 5-9, 1999
Submitted: 1999-05-19
The standard Big-Bang theory predicts a cosmic neutrino background with an average number density of $\sim 100/cm^3$ per flavor. The most promising way of its detection is measuring the feeble ``neutrino wind'' forces exerted on macroscopic targets. The expected acceleration is $\sim 10^{-23} cm/s^2$ for Dirac neutrinos with a local number density $\sim 10^7/cm^3$. A novel torsion balance design is presented, which addresses the sensitivity-limiting factors of existing balances, such as seismic and thermal noise, and angular readout resolution and stability.
[15]  oai:arXiv.org:astro-ph/9902102  [pdf] - 105121
A Relic Neutrino Detector
Comments: 4 pages, 2 figures. In proceedings of the COSMO-98 Int'l Workshop on Particle Physics and the Early Universe, edited by D. Caldwell (AIP Press, New York, 1999)
Submitted: 1999-02-05
Probably the most promising way of detecting cosmic neutrinos is measuring the mechanical force exerted by elastic scattering of cosmic neutrinos from macroscopic targets. The expected acceleration is $\sim 10^{-23} cm/s^2$ for Dirac neutrinos of mass $\sim 10 eV$ and local density $\sim 10^7/ cm^3$. A novel torsion balance design is presented. which addresses the sensitivity-limiting factors of existing balances, such as seismic and thermal noise, and angular readout resolution and stability.
[16]  oai:arXiv.org:hep-ph/9807374  [pdf] - 116281
Studies of the motion and decay of axion walls bounded by strings
Comments: 37 pages, 10 figures, a minor mistake was corrected, several references and comments were added
Submitted: 1998-07-14, last modified: 1998-09-22
We discuss the appearance at the QCD phase transition, and the subsequent decay, of axion walls bounded by strings in N=1 axion models. We argue on intuitive grounds that the main decay mechanism is into barely relativistic axions. We present numerical simulations of the decay process. In these simulations, the decay happens immediately, in a time scale of order the light travel time, and the average energy of the radiated axions is $<\omega_a > \simeq 7 m_a$ for $v_a/m_a \simeq 500$. $<\omega_a>$ is found to increase approximately linearly with $\ln(v_a/m_a)$. Extrapolation of this behaviour yields $<\omega_a> \sim 60 m_a$ in axion models of interest. We find that the contribution to the cosmological energy density of axions from wall decay is of the same order of magnitude as that from vacuum realignment, with however large uncertainties. The velocity dispersion of axions from wall decay is found to be larger, by a factor $10^3$ or so, than that of axions from vacuum realignment and string decay. We discuss the implications of this for the formation and evolution of axion miniclusters and for the direct detection of axion dark matter on Earth. Finally we discuss the cosmology of axion models with $N>1$ in which the domain wall problem is solved by introducing a small U$_{PQ}$(1) breaking interaction. We find that in this case the walls decay into gravitational waves.
[17]  oai:arXiv.org:astro-ph/9801286  [pdf] - 100135
Results from a High-Sensitivity Search for Cosmic Axions
Comments: 11 text pages, 4 figures (figures 2 and 3 combined), to be published in Physical Review Letters
Submitted: 1998-01-28
We report the first results of a high-sensitivity (10^{-23} Watt) search for light halo axions through their conversion to microwave photons. At 90 percent confidence we exclude a KSVZ axion of mass 2.9 x 10^{-6} eV to 3.3 x 10^{-6} eV as the dark matter in the halo of our Galaxy.
[18]  oai:arXiv.org:astro-ph/9607022  [pdf] - 94964
First results from a second generation galactic axion experiment
Comments: 4 pages with 4 embedded figures, Postscript, to be published in the Proceedings of the DM 96 conference held in Santa Monica, Feb. 14-16, 1996
Submitted: 1996-07-03
We report first results from a large scale search for dark matter axions. The experiment probes axion masses of 1.3-13 micro-eV at a sensitivity which is about 50 times higher than previous pilot experiments. We have already scanned part of this mass range at a sensitivity better than required to see at least one generic axion model, the KSVZ axion. Data taking at full sensitivity commenced in February 1996 and scanning the proposed mass range will require three years.
[19]  oai:arXiv.org:astro-ph/9508013  [pdf] - 93069
A 2nd generation cosmic axion experiment
Comments: Postscript, 6 pages, 4 figures; submitted to proceedings of: XXXth Recontres de Moriond, 'Dark Matter in Cosmology", Villars-sur-Ollon, Switzerland, Jan 21-28, 1995
Submitted: 1995-08-03
An experiment is described to detect dark matter axions trapped in the halo of our galaxy. Galactic axions are converted into microwave photons via the Primakoff effect in a static background field provided by a superconducting magnet. The photons are collected in a high Q microwave cavity and detected by a low noise receiver. The axion mass range accessible by this experiment is 1.3-13 micro-eV. The expected sensitivity will be roughly 50 times greater than achieved by previous experiments in this mass range. The assembly of the detector is well under way at LLNL and data taking will start in mid-1995.
[20]  oai:arXiv.org:astro-ph/9404072  [pdf] - 91428
Measurements of Anisotropy in the Cosmic Microwave Background Radiation at Degree Angular Scales Near the Stars Sigma Hercules and Iota Draconis
Comments: 13 pages, postscript file, 2 figures
Submitted: 1994-04-27, last modified: 1994-05-01
We present results from two four-frequency observations centered near the stars Sigma Hercules and Iota Draconis during the fourth flight of the Millimeter-wave Anisotropy eXperiment (MAX). The observations were made of 6 x 0.6-degree strips of the sky with 1.4-degree peak to peak sinusoidal chop in all bands. The FWHM beam sizes were 0.55+/-0.05 degrees at 3.5 cm-1 and a 0.75+/-0.05 degrees at 6, 9, and 14 cm-1. Significant correlated structures were observed at 3.5, 6 and 9 cm-1. The spectra of these signals are inconsistent with thermal emission from known interstellar dust populations. The extrapolated amplitudes of synchrotron and free-free emission are too small to account for the amplitude of the observed structures. If the observed structures are attributed to CMB anisotropy with a Gaussian autocorrelation function and a coherence angle of 25', then the most probable values are DT/TCMB = (3.1 +1.7-1.3) x 10^-5 for the Sigma Hercules scan, and DT/TCMB = (3.3 +/- 1.1) x 10^-5 for the Iota Draconis scan (95% confidence upper and lower limits). Finally a comparison of all six MAX scans is presented.
[21]  oai:arXiv.org:astro-ph/9404036  [pdf] - 91392
Measurements of Anisotropy in the Cosmic Microwave Background Radiation at 0.5 Degree Angular Scales Near the Star Gamma Ursae Minoris
Comments: 16 pages, postscript
Submitted: 1994-04-17, last modified: 1994-04-19
We present results from a four frequency observation of a 6 x 0.6 degree strip of the sky centered near the star Gamma Ursae Minoris during the fourth flight of the Millimeter-wave Anisotropy eXperiment (MAX). The observation was made with a 1.4 degree peak-to-peak sinusoidal chop in all bands. The FWHM beam sizes were 0.55 +/- 0.05 degrees at 3.5 cm-1 and 0.75 +/-0.05 degrees at 6, 9, and 14 cm-1. During this observation significant correlated structure was observed at 3.5, 6 and 9 cm-1 with amplitudes similar to those observed in the GUM region during the second and third flights of MAX. The frequency spectrum is consistent with CMB and inconsistent with thermal emission from interstellar dust. The extrapolated amplitudes of synchrotron and free-free emission are too small to account for the amplitude of the observed structure. If all of the structure is attributed to CMB anisotropy with a Gaussian autocorrelation function and a coherence angle of 25', then the most probable values of DeltaT/TCMB in the 3.5, 6, and 9 cm-1 bands are 4.3 (+2.7, -1.6) x 10-5, 2.8 (+4.3, -1.1) x 10-5, and 3.5 (+3.0, -1.6) x 10-5 (95% confidence upper and lower limits), respectively.