sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Giampa, P.

Normalized to: Giampa, P.

12 article(s) in total. 624 co-authors, from 1 to 10 common article(s). Median position in authors list is 26,5.

[1]  oai:arXiv.org:2005.14667  [pdf] - 2105793
Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
Comments:
Submitted: 2020-05-29, last modified: 2020-06-01
DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.
[2]  oai:arXiv.org:2004.02024  [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
The DarkSide collaboration; Aalseth, C. E.; Abdelhakim, S.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Barbaryan, V.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Castellani, A.; Castello, P.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Chashin, S.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Coccetti, F.; Cocco, V.; Colocci, M.; Vidal, E. Conde; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Falco, A.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; De Pasquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Frolov, E.; Froudakis, G. E.; Funicello, N.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garbini, M.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Grassi, M.; Grate, J. W.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Haranczyk, M.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; La Commara, M.; La Delfa, L.; Lai, M.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Manecki, S.; Mapelli, L.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Rojas, A. D. Martinez; Mascia, M.; Mason, J.; Masoni, A.; McDonald, A. B.; Messina, A.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Nosov, V.; Nowak, J. A.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Pietropaolo, F.; Pocar, A.; Pollmann, T. R.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Ripoli, C.; Rivetti, A.; Rode, J.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sandford, E.; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 25 pages, 22 figures, 3 tables
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition to it, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) range. The first is due to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral bremsstrahlung, NBrS). The second, responsible for electron avalanche scintillations in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a SiPM matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillations effects. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter search. It should be emphasized that this is the first practical application of the NBrS effect in detection science.
[3]  oai:arXiv.org:2001.08106  [pdf] - 2080977
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
The DarkSide Collaboration; Aalseth, C. E.; Abdelhakim, S.; Acerbi, F.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Carpinelli, M.; Castellani, A.; Castello, P.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Cocco, V.; Colocci, M.; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Falco, A.; De Filippis, G.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; DePaquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giagu, S.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kim, S.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; Kuźniak, M.; La Commara, M.; La Delfa, L.; Lai, M.; Langrock, S.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Manzano, R. López; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Morales, J. J. Martínez; Rojas, A. D. Martinez; Martoff, C. J.; Mascia, M.; Mason, J.; Masoni, A.; Mazzi, A.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Piemonte, C.; Pietropaolo, F.; Pocar, A.; Pollman, T.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Rivetti, A.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sablone, D.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 13 pages, 8 figures. Corresponding author: E. S\'anchez Garc\'ia
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $\gamma$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
[4]  oai:arXiv.org:1902.04048  [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Comments:
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
[5]  oai:arXiv.org:1903.03663  [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.; Giampa, P.; Retiere, F.; Kroeger, J.; Zhang, G.; Ward, M.; Margetak, P.; Lic, G.; Tsang, T.; Doria, L.; Kharusi, S. Al; Alfaris, M.; Anton, G.; Arnquist, I. J.; Badhrees, I.; Barbeau, P. S.; Beck, D.; Belov, V.; Bhatta, T.; Blatchford, J.; Brodsky, J. P.; Brown, E.; Brunner, T.; Cao, G. F.; Cao, L.; Cen, W. R.; Chambers, C.; Charlebois, S. A.; Chiu, M.; Cleveland, B.; Coon, M.; Craycraft, A.; Dalmasson, J.; Daniels, T.; Darroch, L.; Daugherty, S. J.; Croix, A. De St.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Dilling, J.; Ding, Y. Y.; Dolinski, M. J.; Dragone, A.; Echevers, J.; Elbeltagi, M.; Fabris, L.; Fairbank, D.; Fairbank, W.; Farine, J.; Feyzbakhsh, S.; Fontaine, R.; Gautam, P.; Giacomini, G.; Gornea, R.; Gratta, G.; Hansen, E. V.; Heffner, M.; Hoppe, E. W.; Hoßl, J.; House, A.; Hughes, M.; Ito, Y.; Iverson, A.; Jamil, A.; Jewell, M. J.; Jiang, X. S.; Karelin, A.; Kaufman, L. J.; Kodroff, D.; Koffas, T.; Krucken, R.; Kuchenkov, A.; Kumar, K. S.; Lana, Y.; Larson, A.; Lenardo, B. G.; Leonarda, D. S.; Lik, S.; Li, Z.; Licciardi, C.; Linw, Y. H.; Lv, P.; MacLellan, R.; McElroy, T.; Medina-Peregrina, M.; Michel, T.; Mong, B.; Moore, D. C.; Murray, K.; Nakarmi, P.; Newby, R. J.; Ning, Z.; Njoya, O.; Nolet, F.; Nusair, O.; Odgers, K.; Odian, A.; Oriunno, M.; Orrell, J. L.; Ortega, G. S.; Ostrovskiy, I.; Overman, C. T.; Parent, S.; Piepkez, A.; Pocar, A.; Pratte, J. -F.; Qiu, D.; Radeka, V.; Raguzin, E.; Rescia, S.; Richman, M.; Robinson, A.; Rossignol, T.; Rowson, P. C.; Roy, N.; Saldanha, R.; Sangiorgio, S.; VIII, K. Skarpaas; Soma, A. K.; St-Hilaire, G.; Stekhanov, V.; Stiegler, T.; Sun, X. L.; Tarka, M.; Todd, J.; Tolba, T.; Totev, T. I.; Tsang, R.; Vachon, F.; Veeraraghavan, V.; Visser, G.; Vuilleumier, J. -L.; Wagenpfeil, M.; Walent, M.; Wang, Q.; Watkins, J.; Weber, M.; Wei, W.; Wen, L. J.; Wichoski, U.; Wu, S. X.; Wu, W. H.; Wu, X.; Xia, Q.; Yang, H.; Yang, L.; Yen, Y. -R.; Zeldovich, O.; Zhao, J.; Zhou, Y.; Ziegler, T.
Comments:
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[6]  oai:arXiv.org:1905.05811  [pdf] - 1994027
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
Comments:
Submitted: 2019-05-14
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $\beta$ and $\gamma$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $\mu$Bq/kg of argon.
[7]  oai:arXiv.org:1707.08042  [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Comments: Accepted for publication in Physical Review Letters
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).
[8]  oai:arXiv.org:1712.01982  [pdf] - 1832993
Design and Construction of the DEAP-3600 Dark Matter Detector
Comments: minor corrections in version 2. 70 pages, 24 figures, to be submitted to Astroparticle Physics Journal
Submitted: 2017-12-05, last modified: 2018-04-10
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.
[9]  oai:arXiv.org:1706.04854  [pdf] - 1584735
In-situ Surface Contamination Removal and Cool-down Process of the DEAP-3600 Experiment
Comments: 5 pages, 3 figures, XIV International Conference on Topics in Astroparticle and Underground Physics (TAUP 2015)
Submitted: 2017-06-15
The DEAP-3600 experiment is a single-phase detector that uses 3600 Kg of liquid argon to search for Dark Matter at SNOLAB, Sudbury, Canada, 6800 ft. underground. The projected sensitivity to the spin-independent WIMP-nucleon cross-section is $10^{-46}$ cm$^{2}$ for a WIMP mass of 100 GeV. A key experimental requirement is the reduction of any possible source of background that would mimic a Dark Matter signal. This document will review how radiogenic surface backgrounds were reduced in-situ by removing 500 microns of acrylic from the innermost part of the detector with a resurfacing robot. Furthermore, it will review the transient cool-down process of the experiment, necessary to reach cryogenic operating temperature.
[10]  oai:arXiv.org:1704.01882  [pdf] - 1565347
Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface
Comments: 17 pages, 15 figures, to be published in JINST
Submitted: 2017-04-06
DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a target medium to perform a sensitive spin-independent dark matter search. Argon scintillates in the vacuum ultraviolet spectrum, which requires wavelength shifting to convert the VUV photons to visible so they can be transmitted through the acrylic light guides and detected by the surrounding photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene was evaporatively deposited to the inner surface of the acrylic vessel under vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an estimated coating thickness of 3.00 $\pm$ 0.02 $\mu$m which is successfully wavelength shifting with liquid argon in the detector. Details on the wavelength shifter coating requirements, deposition source, testing, and final performance are presented.
[11]  oai:arXiv.org:0904.2930  [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
Comments: Accepted for publication in Astroparticle Physics
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag. The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale. We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.
[12]  oai:arXiv.org:1410.7673  [pdf] - 1416317
DEAP-3600 Dark Matter Search
Comments: International Conference on High Energy Physics (ICHEP 2014), Valencia, 2014
Submitted: 2014-10-27, last modified: 2015-08-25
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass demonstrated a high level of pulse-shape discrimination (PSD) for reducing $\beta$/$\gamma$ backgrounds and helped to develop low radioactivity techniques to mitigate surface-related $\alpha$ backgrounds. Construction of the DEAP-3600 detector is nearly complete and commissioning is starting in 2014. The target sensitivity to spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons of 10$^{-46}$ cm$^2$ will allow one order of magnitude improvement in sensitivity over current searches at 100 GeV WIMP mass. This paper presents an overview and status of the DEAP-3600 project and discusses plans for a future multi-tonne experiment, DEAP-50T.