sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Flanigan, D.

Normalized to: Flanigan, D.

23 article(s) in total. 181 co-authors, from 1 to 18 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1711.02523  [pdf] - 1723973
Development of Multi-Chroic MKIDs for Next-Generation CMB Polarization Studies
Comments: LTD-17 paper accepted by Journal of Low Temperature Physics
Submitted: 2017-11-07, last modified: 2018-07-29
We report on the status of an ongoing effort to develop arrays of horn-coupled, polarization-sensitive microwave kinetic inductance detectors (MKIDs) that are each sensitive to two spectral bands between 125 and 280 GHz. These multi-chroic MKID arrays are tailored for next-generation, large-detector-count experiments that are being designed to simultaneously characterize the polarization properties of both the cosmic microwave background (CMB) and Galactic dust emission. We present our device design and describe laboratory-based measurement results from two 23-element prototype arrays. From dark measurements of our first engineering array we demonstrated a multiplexing factor of 92, showed the resonators respond to bath temperature changes as expected, and found that the fabrication yield was 100%. From our first optically loaded array we found the MKIDs respond to millimeter-wave pulses, additional optical characterization measurements are ongoing. We end by discussing our plans for scaling up this technology to kilo-pixel arrays over the next two years.
[2]  oai:arXiv.org:1403.2369  [pdf] - 1715860
A Measurement of the Cosmic Microwave Background B-Mode Polarization Power Spectrum at Sub-Degree Scales with POLARBEAR
Comments: 22 pages, 12 figures. v3 is updated to reflect the erratum published in ApJ 2017 848:73, which changed the rejection of the hypothesis of no B-mode polarization power from gravitational lensing from 97.2% to 97.1%
Submitted: 2014-03-10, last modified: 2018-07-16
We report a measurement of the B-mode polarization power spectrum in the cosmic microwave background (CMB) using the POLARBEAR experiment in Chile. The faint B-mode polarization signature carries information about the Universe's entire history of gravitational structure formation, and the cosmic inflation that may have occurred in the very early Universe. Our measurement covers the angular multipole range 500 < l < 2100 and is based on observations of an effective sky area of 25 square degrees with 3.5 arcmin resolution at 150 GHz. On these angular scales, gravitational lensing of the CMB by intervening structure in the Universe is expected to be the dominant source of B-mode polarization. Including both systematic and statistical uncertainties, the hypothesis of no B-mode polarization power from gravitational lensing is rejected at 97.1% confidence. The band powers are consistent with the standard cosmological model. Fitting a single lensing amplitude parameter A_BB to the measured band powers, A_BB = 1.12 +/- 0.61 (stat) +0.04/-0.12 (sys) +/- 0.07 (multi), where A_BB = 1 is the fiducial WMAP-9 LCDM value. In this expression, "stat" refers to the statistical uncertainty, "sys" to the systematic uncertainty associated with possible biases from the instrument and astrophysical foregrounds, and "multi" to the calibration uncertainties that have a multiplicative effect on the measured amplitude A_BB.
[3]  oai:arXiv.org:1710.02239  [pdf] - 1641296
Design and performance of dual-polarization lumped-element kinetic inductance detectors for millimeter-wave polarimetry
Comments: Accepted in Astronomy & Astrophysics, revised version. 11 pages, 8 figures
Submitted: 2017-10-05, last modified: 2017-11-19
Lumped-element kinetic inductance detectors (LEKIDs) are an attractive technology for millimeter-wave observations that require large arrays of extremely low-noise detectors. We designed, fabricated and characterized 64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs optimized for ground-based CMB polarimetry. Our devices are sensitive to two orthogonal polarizations in a single spectral band centered on 150 GHz with $\Delta\nu/\nu=0.2$. The $65\times 65$ mm square arrays are designed to be tiled into the focal plane of an optical system. We demonstrate the viability of these dual-polarization LEKIDs with laboratory measurements. The LEKID modules are tested with an FPGA-based readout system in a sub-kelvin cryostat that uses a two-stage adiabatic demagnetization refrigerator. The devices are characterized using a blackbody and a millimeter-wave source. The polarization properties are measured with a cryogenic stepped half-wave plate. We measure the resonator parameters and the detector sensitivity, noise spectrum, dynamic range, and polarization response. The resonators have internal quality factors approaching $1\times 10^{6}$. The detectors have uniform response between orthogonal polarizations and a large dynamic range. The detectors are photon-noise limited above 1 pW of absorbed power. The noise-equivalent temperatures under a 3.4 K blackbody load are $<100~\mu\mathrm{K\sqrt{s}}$. The polarization fractions of detectors sensitive to orthogonal polarizations are >80%. The entire array is multiplexed on a single readout line, demonstrating a multiplexing factor of 128. The array and readout meet the requirements for 4 arrays to be read out simultaneously for a multiplexing factor of 512. This laboratory study demonstrates the first dual-polarization LEKID array optimized for CMB polarimetry and shows the readiness of the detectors for on-sky observations.
[4]  oai:arXiv.org:1510.06609  [pdf] - 1579736
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Comments: Matches published version (which is open access) and includes supplemental material
Submitted: 2015-10-22, last modified: 2017-05-24
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
[5]  oai:arXiv.org:1701.08461  [pdf] - 1581309
High quality factor manganese-doped aluminum lumped-element kinetic inductance detectors sensitive to frequencies below 100 GHz
Comments: 5 pages, 4 figures. This revised version has been accepted for publication by Appl. Phys. Lett
Submitted: 2017-01-29, last modified: 2017-04-15
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to millimeter-wave photons have been shown to exhibit high quality factors, making them highly sensitive and multiplexable. The superconducting gap of aluminum limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped aluminum (Al-Mn) has a tunable critical temperature and could therefore be an attractive material for LEKIDs sensitive to frequencies below 100 GHz if the internal quality factor remains sufficiently high when manganese is added to the film. To investigate, we measured some of the key properties of Al-Mn LEKIDs. A prototype eight-element LEKID array was fabricated using a 40 nm thick film of Al-Mn deposited on a 500 {\mu}m thick high-resistivity, float-zone silicon substrate. The manganese content was 900 ppm, the measured $T_c = 694\pm1$ mK, and the resonance frequencies were near 150 MHz. Using measurements of the forward scattering parameter $S_{21}$ at various bath temperatures between 65 and 250 mK, we determined that the Al-Mn LEKIDs we fabricated have internal quality factors greater than $2 \times 10^5$, which is high enough for millimeter-wave astrophysical observations. In the dark conditions under which these devices were measured, the fractional frequency noise spectrum shows a shallow slope that depends on bath temperature and probe tone amplitude, which could be two-level system noise. The anticipated white photon noise should dominate this level of low-frequency noise when the detectors are illuminated with millimeter-waves in future measurements. The LEKIDs responded to light pulses from a 1550 nm light-emitting diode, and we used these light pulses to determine that the quasiparticle lifetime is 60 {\mu}s.
[6]  oai:arXiv.org:1609.06352  [pdf] - 1492815
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
Comments: 5 pages, 4 figures
Submitted: 2016-09-20
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \, \mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2 \, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient magnetic fields as small as approximately $30 \, \mathrm{\mu T}$ can produce vortices in the thin-film aluminum as it transitions because the bulk aluminum package has not yet transitioned and therefore is not yet shielding. These vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$ and ultimately produce low internal quality factors in the thin-film superconducting resonators. We show that by controlling the strength of the magnetic field present when the thin film transitions, we can control the internal quality factor of the resonators. We also compare the noise performance with and without vortices present, and find no evidence for excess noise beyond the increase in amplifier noise, which is expected with increasing loss.
[7]  oai:arXiv.org:1607.03796  [pdf] - 1441570
Polarization Sensitive Multi-Chroic MKIDs
Comments: To appear in the Proc. SPIE
Submitted: 2016-07-13
We report on the development of scalable prototype microwave kinetic inductance detector (MKID) arrays tailored for future multi-kilo-pixel experiments that are designed to simultaneously characterize the polarization properties of both the cosmic microwave background (CMB) and Galactic dust emission. These modular arrays are composed of horn-coupled, polarization-sensitive MKIDs, and each pixel has four detectors: two polarizations in two spectral bands between 125 and 280 GHz. A horn is used to feed each array element, and a planar orthomode transducer, composed of two waveguide probe pairs, separates the incoming light into two linear polarizations. Diplexers composed of resonant-stub band-pass filters separate the radiation into 125 to 170 GHz and 190 to 280 GHz pass bands. The millimeter-wave power is ultimately coupled to a hybrid co-planar waveguide microwave kinetic inductance detector using a novel, broadband circuit developed by our collaboration. Electromagnetic simulations show the expected absorption efficiency of the detector is approximately 90%. Array fabrication will begin in the summer of 2016.
[8]  oai:arXiv.org:1607.03448  [pdf] - 1531012
Development of dual-polarization LEKIDs for CMB observations
Comments: 7 pages, 5 figures, Proc. SPIE Astronomical Telescopes + Instrumentation 2016, Paper 9914-24
Submitted: 2016-07-12
We discuss the design considerations and initial measurements from arrays of dual-polarization, lumped element kinetic inductance detectors (LEKIDs) nominally designed for cosmic microwave background (CMB) studies. The detectors are horn-coupled, and each array element contains two single-polarization LEKIDs, which are made from thin-film aluminum and optimized for a single spectral band centered on 150 GHz. We are developing two array architectures, one based on 160 micron thick silicon wafers and the other based on silicon-on-insulator (SOI) wafers with a 30 micron thick device layer. The 20-element test arrays (40 LEKIDs) are characterized with both a linearly-polarized electronic millimeter wave source and a thermal source. We present initial measurements including the noise spectra, noise-equivalent temperature, and responsivity. We discuss future testing and further design optimizations to be implemented.
[9]  oai:arXiv.org:1512.01847  [pdf] - 1347758
A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
Comments: 7 pages, 5 figures, accepted for publication in the Journal of Low Temperature Physics
Submitted: 2015-12-06
We discuss the design and measured performance of a titanium nitride (TiN) mesh absorber we are developing for controlling optical crosstalk in horn-coupled lumped-element kinetic inductance detector arrays for millimeter-wavelengths. This absorber was added to the fused silica anti-reflection coating attached to previously-characterized, 20-element prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon substrates. To test the TiN crosstalk absorber, we compared the measured response and noise properties of LEKID arrays with and without the TiN mesh. For this test, the LEKIDs were illuminated with an adjustable, incoherent electronic millimeter-wave source. Our measurements show that the optical crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on average, so the approach is effective and a viable candidate for future kilo-pixel arrays.
[10]  oai:arXiv.org:1509.04658  [pdf] - 1347523
WSPEC: A waveguide filter-bank focal plane array spectrometer for millimeter wave astronomy and cosmology
Comments: 7 pages, 4 figures, submitted to Journal of Low Temperature Physics
Submitted: 2015-09-15
Imaging and spectroscopy at (sub-)millimeter wavelengths are key frontiers in astronomy and cosmology. Large area spectral surveys with moderate spectral resolution (R=50-200) will be used to characterize large scale structure and star formation through intensity mapping surveys in emission lines such as the CO rotational transitions. Such surveys will also be used to study the SZ effect, and will detect the emission lines and continuum spectrum of individual objects. WSPEC is an instrument proposed to target these science goals. It is a channelizing spectrometer realized in rectangular waveguide, fabricated using conventional high-precision metal machining. Each spectrometer is coupled to free space with a machined feed horn, and the devices are tiled into a 2D array to fill the focal plane of the telescope. The detectors will be aluminum Lumped-Element Kinetic Inductance Detectors (LEKIDs). To target the CO lines and SZ effect, we will have bands at 135-175 GHz and 190-250 GHz, each Nyquist-sampled at R~200 resolution. Here we discuss the instrument concept and design, and successful initial testing of a WR10 (i.e. 90 GHz) prototype spectrometer. We recently tested a WR5 (180 GHz) prototype to verify that the concept works at higher frequencies, and also designed a resonant backshort structure that may further increase the optical efficiency. We are making progress towards integrating a spectrometer with a LEKID array and deploying a prototype device to a telescope for first light.
[11]  oai:arXiv.org:1404.7103  [pdf] - 1546171
Galaxy cluster scaling relations measured with APEX-SZ
Comments: 17 pages, 4 figures, submitted to MNRAS
Submitted: 2014-04-28, last modified: 2015-04-26
We present thermal Sunyaev-Zel'dovich effect (SZE) measurements for 42 galaxy clusters observed at 150 GHz with the APEX-SZ experiment. For each cluster, we model the pressure profile and calculate the integrated Comptonization $Y$ to estimate the total thermal energy of the intracluster medium (ICM). We compare the measured $Y$ values to X-ray observables of the ICM from the literature (cluster gas mass $M_{\rm{gas}}$, temperature $T_X$, and $Y_X =M_{\rm{gas}}T_X$) that relate to total cluster mass. We measure power law scaling relations, including an intrinsic scatter, between the SZE and X-ray observables for three subsamples within the set of 42 clusters that have uniform X-ray analysis in the literature. We observe that differences between these X-ray analyses introduce significant variability into the measured scaling relations, particularly affecting the normalization. For all three subsamples, we find results consistent with a self-similar model of cluster evolution dominated by gravitational effects. Comparing to predictions from numerical simulations, these scaling relations prefer models that include cooling and feedback in the ICM. Lastly, we measure an intrinsic scatter of $\sim28$ per cent in the $Y-Y_X\,$ scaling relation for all three subsamples.
[12]  oai:arXiv.org:1407.7749  [pdf] - 971383
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
Comments:
Submitted: 2014-07-29, last modified: 2015-03-26
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background (CMB) studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated twenty-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the noise-equivalent temperatures (NET) for a 4 K optical load are in the range 26$\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}$.
[13]  oai:arXiv.org:1503.06528  [pdf] - 969448
WSPEC: A Waveguide Filter Bank Spectrometer
Comments: 3 pages, 5 figures, 26th International Symposium on Space Terahertz Technology
Submitted: 2015-03-23
We have designed, fabricated, and measured a 5-channel prototype spectrometer pixel operating in the WR10 band to demonstrate a novel moderate-resolution (R=f/{\Delta}f~100), multi-pixel, broadband, spectrometer concept for mm and submm-wave astronomy. Our design implements a transmission line filter bank using waveguide resonant cavities as a series of narrow-band filters, each coupled to an aluminum kinetic inductance detector (KID). This technology has the potential to perform the next generation of spectroscopic observations needed to drastically improve our understanding of the epoch of reionization (EoR), star formation, and large-scale structure of the universe. We present our design concept, results from measurements on our prototype device, and the latest progress on our efforts to develop a 4-pixel demonstrator instrument operating in the 130-250 GHz band.
[14]  oai:arXiv.org:1503.04684  [pdf] - 957156
Design of Dual-Polarization Horn-Coupled Kinetic Inductance Detectors for Cosmic Microwave Background Polarimetry
Comments: 3 pages, 3 figures, to appear in Proceedings of International Symposium on Space Terahertz Technology 2015
Submitted: 2015-03-16
Mapping the polarization of the Cosmic Microwave Background is yielding exciting data on the origin of the universe, the reionization of the universe, and the growth of cosmic structure. Kilopixel arrays represent the current state of the art, but advances in detector technology are needed to enable the larger detector arrays needed for future measurements. Here we present a design for single-band dual-polarization Kinetic Inductance Detectors (KIDs) at 20% bandwidths centered at 145, 220, and 280 GHz. The detection and readout system is nearly identical to the successful photon-noise-limited aluminum Lumped-Element KIDs that have been recently built and tested by some of the authors. Fabricating large focal plane arrays of the feed horns and quarter-wave backshorts requires only conventional precision machining. Since the detectors and readout lines consist only of a single patterned aluminum layer on a SOI wafer, arrays of the detectors can be built commercially or at a standard university cleanroom.
[15]  oai:arXiv.org:1407.6249  [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in Greenland
Comments:
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study is based on lumped-element kinetic inductance detectors (LEKIDs) and an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The telescope is mounted inside the receiver and cooled to $<\,4$ K by a closed-cycle $^4$He refrigerator to reduce background loading on the detectors. Linearly polarized signals from the sky are modulated with a metal-mesh half-wave plate that is rotated at the aperture stop of the telescope with a hollow-shaft motor based on a superconducting magnetic bearing. The modular detector array design includes at least 2300 LEKIDs, and it can be configured for spectral bands centered on 150~GHz or greater. Our study considered configurations for observing in spectral bands centered on 150, 210 and 267~GHz. The entire polarimeter is mounted on a commercial precision rotary air bearing, which allows fast azimuth scan speeds with negligible vibration and mechanical wear over time. A slip ring provides power to the instrument, enabling circular scans (360 degrees of continuous rotation). This mount, when combined with sky rotation and the latitude of the observation site, produces a hypotrochoid scan pattern, which yields excellent cross-linking and enables 34\% of the sky to be observed using a range of constant elevation scans. This scan pattern and sky coverage combined with the beam size (15~arcmin at 150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular power spectra.
[16]  oai:arXiv.org:1312.6646  [pdf] - 851338
Measurement of the Cosmic Microwave Background Polarization Lensing Power Spectrum with the POLARBEAR experiment
Comments: 7 pages, 3 figures. Matches Physical Review Letters accepted version. Submitted on 11 March 2014; accepted on 25 April 2014. The companion paper (arXiv:1312.6645) describes a measurement of polarization lensing in cross-correlation
Submitted: 2013-12-23, last modified: 2014-04-27
Gravitational lensing due to the large-scale distribution of matter in the cosmos distorts the primordial Cosmic Microwave Background (CMB) and thereby induces new, small-scale $B$-mode polarization. This signal carries detailed information about the distribution of all the gravitating matter between the observer and CMB last scattering surface. We report the first direct evidence for polarization lensing based on purely CMB information, from using the four-point correlations of even- and odd-parity $E$- and $B$-mode polarization mapped over $\sim30$ square degrees of the sky measured by the POLARBEAR experiment. These data were analyzed using a blind analysis framework and checked for spurious systematic contamination using null tests and simulations. Evidence for the signal of polarization lensing and lensing $B$-modes is found at 4.2$\sigma$ (stat.+sys.) significance. The amplitude of matter fluctuations is measured with a precision of $27\%$, and is found to be consistent with the Lambda Cold Dark Matter ($\Lambda$CDM) cosmological model. This measurement demonstrates a new technique, capable of mapping all gravitating matter in the Universe, sensitive to the sum of neutrino masses, and essential for cleaning the lensing $B$-mode signal in searches for primordial gravitational waves.
[17]  oai:arXiv.org:1312.6645  [pdf] - 812508
Evidence for Gravitational Lensing of the Cosmic Microwave Background Polarization from Cross-correlation with the Cosmic Infrared Background
Comments: 6 pages, 2 figures. v2: replaced with version accepted for publication in Physical Review Letters. The companion paper (arXiv:1312.6646) describes a measurement of the polarization lensing power spectrum
Submitted: 2013-12-23, last modified: 2014-03-07
We reconstruct the gravitational lensing convergence signal from Cosmic Microwave Background (CMB) polarization data taken by the POLARBEAR experiment and cross-correlate it with Cosmic Infrared Background (CIB) maps from the Herschel satellite. From the cross-spectra, we obtain evidence for gravitational lensing of the CMB polarization at a statistical significance of 4.0$\sigma$ and evidence for the presence of a lensing $B$-mode signal at a significance of 2.3$\sigma$. We demonstrate that our results are not biased by instrumental and astrophysical systematic errors by performing null-tests, checks with simulated and real data, and analytical calculations. This measurement of polarization lensing, made via the robust cross-correlation channel, not only reinforces POLARBEAR auto-correlation measurements, but also represents one of the early steps towards establishing CMB polarization lensing as a powerful new probe of cosmology and astrophysics.
[18]  oai:arXiv.org:1308.0235  [pdf] - 857218
The Detector System for the Stratospheric Kinetic Inductance Polarimeter (SKIP)
Comments: J Low Temp Phys DOI 10.1007/s10909-013-1014-3 The final publication is available at link.springer.com
Submitted: 2013-08-01, last modified: 2014-01-05
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The detector readout system is based on the ROACH-1 board, and the detectors will be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To minimize detector loading and maximize sensitivity, the entire optical system will be cooled to 1 K. Linearly polarized sky signals will be modulated with a metal-mesh half-wave plate that is mounted at the telescope aperture and rotated by a superconducting magnetic bearing. The observation program consists of at least two, five-day flights beginning with the 150 GHz observations.
[19]  oai:arXiv.org:1210.7768  [pdf] - 1152551
The POLARBEAR Experiment
Comments: Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VI, July 6, 2012. To be published in Proceedings of SPIE Volume 8452
Submitted: 2012-10-29
We present the design and characterization of the POLARBEAR experiment. POLARBEAR will measure the polarization of the cosmic microwave background (CMB) on angular scales ranging from the experiment's 3.5 arcminute beam size to several degrees. The experiment utilizes a unique focal plane of 1,274 antenna-coupled, polarization sensitive TES bolometers cooled to 250 milliKelvin. Employing this focal plane along with stringent control over systematic errors, POLARBEAR has the sensitivity to detect the expected small scale B-mode signal due to gravitational lensing and search for the large scale B-mode signal from inflationary gravitational waves. POLARBEAR was assembled for an engineering run in the Inyo Mountains of California in 2010 and was deployed in late 2011 to the Atacama Desert in Chile. An overview of the instrument is presented along with characterization results from observations in Chile.
[20]  oai:arXiv.org:1210.7877  [pdf] - 1152574
The bolometric focal plane array of the Polarbear CMB experiment
Comments:
Submitted: 2012-10-29
The Polarbear Cosmic Microwave Background (CMB) polarization experiment is currently observing from the Atacama Desert in Northern Chile. It will characterize the expected B-mode polarization due to gravitational lensing of the CMB, and search for the possible B-mode signature of inflationary gravitational waves. Its 250 mK focal plane detector array consists of 1,274 polarization-sensitive antenna-coupled bolometers, each with an associated lithographed band-defining filter. Each detector's planar antenna structure is coupled to the telescope's optical system through a contacting dielectric lenslet, an architecture unique in current CMB experiments. We present the initial characterization of this focal plane.
[21]  oai:arXiv.org:1112.4215  [pdf] - 1092468
Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic Microwave Background Measurements
Comments: 28 pages, 17 figures, accepted to Review of Scientific Instruments. Resubmitted revised version to arxiv July 2012 including very minor changes to address reviewer's comments
Submitted: 2011-12-18, last modified: 2012-07-17
A technological milestone for experiments employing Transition Edge Sensor (TES) bolometers operating at sub-kelvin temperature is the deployment of detector arrays with 100s--1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ~MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with Superconducting Quantum Interference Devices (SQUIDs) operating at 4 K. Room-temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.
[22]  oai:arXiv.org:1110.2101  [pdf] - 423233
Ultra High Energy Cosmology with POLARBEAR
Comments: 8 pages, 6 figures, DPF 2011 conference proceedings
Submitted: 2011-10-10
Observations of the temperature anisotropy of the Cosmic Microwave Background (CMB) lend support to an inflationary origin of the universe, yet no direct evidence verifying inflation exists. Many current experiments are focussing on the CMB's polarization anisotropy, specifically its curl component (called "B-mode" polarization), which remains undetected. The inflationary paradigm predicts the existence of a primordial gravitational wave background that imprints a unique B-mode signature on the CMB's polarization at large angular scales. The CMB B-mode signal also encodes gravitational lensing information at smaller angular scales, bearing the imprint of cosmological large scale structures (LSS) which in turn may elucidate the properties of cosmological neutrinos. The quest for detection of these signals; each of which is orders of magnitude smaller than the CMB temperature anisotropy signal, has motivated the development of background-limited detectors with precise control of systematic effects. The POLARBEAR experiment is designed to perform a deep search for the signature of gravitational waves from inflation and to characterize lensing of the CMB by LSS. POLARBEAR is a 3.5 meter ground-based telescope with 3.8 arcminute angular resolution at 150 GHz. At the heart of the POLARBEAR receiver is an array featuring 1274 antenna-coupled superconducting transition edge sensor (TES) bolometers cooled to 0.25 Kelvin. POLARBEAR is designed to reach a tensor-to-scalar ratio of 0.025 after two years of observation -- more than an order of magnitude improvement over the current best results, which would test physics at energies near the GUT scale. POLARBEAR had an engineering run in the Inyo Mountains of Eastern California in 2010 and will begin observations in the Atacama Desert in Chile in 2011.
[23]  oai:arXiv.org:1011.0763  [pdf] - 348120
The new generation CMB B-mode polarization experiment: POLARBEAR
Comments:
Submitted: 2010-11-02
We describe the Cosmic Microwave Background (CMB) polarization experiment called Polarbear. This experiment will use the dedicated Huan Tran Telescope equipped with a powerful 1,200-bolometer array receiver to map the CMB polarization with unprecedented accuracy. We summarize the experiment, its goals, and current status.