sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Zou, Bugao

Normalized to: Zou, B.

2 article(s) in total. 57 co-authors, from 1 to 2 common article(s). Median position in authors list is 34,5.

[1]  oai:arXiv.org:1911.11687  [pdf] - 2038357
The Design of The CCAT-prime Epoch of Reionization Spectrometer Instrument
Comments: 10 pages, 5 figures, 18th International Workshop on Low Temperature Detectors, submitted to the Journal of Low Temperature Physics
Submitted: 2019-11-26
The Epoch of Reionization Spectrometer (EoR-Spec) is an instrument module for the Prime-Cam receiver of the 6 m aperture CCAT-prime Telescope at 5600 m in Chile. EoR-Spec will perform 158 $\mu$m [CII] line intensity mapping of star-forming regions at redshifts between 3.5 and 8 (420 - 210 GHz), tracing the evolution of structure during early galaxy formation. At lower redshifts, EoR-Spec will observe galaxies near the period of peak star formation - when most stars in today's universe were formed. At higher redshifts, EoR-Spec will trace the late stages of reionization, the early stages of galaxy assembly, and the formation of large-scale, three-dimensional clustering of star-forming galaxies. To achieve its science goals, EoR-Spec will utilize CCAT-prime's exceptionally low water vapor site, large field of view ($\sim 5$ degrees at 210 GHz), and narrow beam widths ($\sim 1$ arcminute at 210 GHz). EoR-Spec will be outfitted with a cryogenic, metamaterial, silicon substrate-based Fabry-Perot Interferometer operating at a resolving power ($\lambda/\Delta\lambda$) of 100. Monolithic dichroic arrays of cryogenic, feedhorn-coupled transition edge sensor bolometers provide approximately 6000 detectors, which are read out using a frequency division multiplexing system based on microwave SQUIDs. The novel design allows the measurement of the [CII] line at two redshifts simultaneously using dichroic pixels and two orders of the Fabry-Perot. Here we present the design and science goals of EoR-Spec, with emphasis on the spectrometer, detector array, and readout designs.
[2]  oai:arXiv.org:1909.02587  [pdf] - 1956586
The CCAT-Prime Submillimeter Observatory
Comments: Astro2020 APC White Paper
Submitted: 2019-09-05
The Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) is a new 6-m, off-axis, low-emissivity, large field-of-view submillimeter telescope scheduled for first light in the last quarter of 2021. In summary, (a) CCAT-prime uniquely combines a large field-of-view (up to 8-deg), low emissivity telescope (< 2%) and excellent atmospheric transmission (5600-m site) to achieve unprecedented survey capability in the submillimeter. (b) Over five years, CCAT-prime first generation science will address the physics of star formation, galaxy evolution, and galaxy cluster formation; probe the re-ionization of the Universe; improve constraints on new particle species; and provide for improved removal of dust foregrounds to aid the search for primordial gravitational waves. (c) The Observatory is being built with non-federal funds (~ \$40M in private and international investments). Public funding is needed for instrumentation (~ \$8M) and operations (\$1-2M/yr). In return, the community will be able to participate in survey planning and gain access to curated data sets. (d) For second generation science, CCAT-prime will be uniquely positioned to contribute high-frequency capabilities to the next generation of CMB surveys in partnership with the CMB-S4 and/or the Simons Observatory projects or revolutionize wide-field, sub-millimetter line intensity mapping surveys.