sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Zolotarova, A.

Normalized to: Zolotarova, A.

4 article(s) in total. 122 co-authors, from 1 to 4 common article(s). Median position in authors list is 49,0.

[1]  oai:arXiv.org:2003.01046  [pdf] - 2057126
First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment
Comments: 6 pages, 4 figures
Submitted: 2020-03-02
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting with electrons, as well as on dark photons down to 1 eV/c$^2$. These are competitive with other searches. In particular, new limits are set on the kinetic mixing of dark photon DM in a so far unconstrained parameter space region in the 6 to 9 eV/c$^2$ mass range. These results demonstrate the high relevance of cryogenic Ge detectors for the search of DM interactions producing eV-scale electron signals.
[2]  oai:arXiv.org:1902.07587  [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li
Comments:
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[3]  oai:arXiv.org:1901.03588  [pdf] - 1871473
Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
Comments: 16 pages, 8 figures. New figure added for Spin-Dependent interactions. Accepted in Phys. Rev. D
Submitted: 2019-01-11, last modified: 2019-04-02
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear recoil based, above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the dark matter search results were studied in the context of Strongly Interacting Massive Particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from $10^{-29}$ to $10^{-26}$~cm$^2$.
[4]  oai:arXiv.org:1706.01070  [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter searches
Comments:
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $\gamma$-ray events has been demonstrated using $\gamma$-calibrations with $^{133}$Ba sources leading to a value of $R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $\gamma$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.