oai:arXiv.org:1711.00943 [pdf] - 1648681
Performance of 20:1 multiplexer for large area charge readouts in
directional dark matter TPC detectors
Submitted: 2017-11-02, last modified: 2018-03-12
More target mass is required in current TPC based directional dark matter
detectors for improved detector sensitivity. This can be achieved by scaling up
the detector volumes, but this results in the need for more analogue signal
channels. A possible solution to reducing the overall cost of the charge
readout electronics is to multiplex the signal readout channels. Here, we
present a multiplexer system in expanded mode based on LMH6574 chips produced
by Texas Instruments, originally designed for video processing. The setup has a
capability of reducing the number of readouts in such TPC detectors by a factor
of 20. Results indicate that the important charge distribution asymmetry along
an ionization track is retained after multiplexed signals are demultiplexed.
[2]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[3]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[4]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.