Normalized to: Yurchenko, V.
[1]
oai:arXiv.org:1911.03473 [pdf] - 2057785
Non-equilibrium antineutrinos of primordial nucleosynthesis
Submitted: 2019-11-08, last modified: 2020-03-03
During the era of primordial nucleosynthesis the background of
non-equilibrium antineutrinos is being formed due to decays of neutrons and
nuclei of tritium. The spectra of antineutrinos of this background were
calculated taking into account the Coulomb interaction between electron and
daughter nucleus in $\beta^\text{--}$-decay. The dependence of these spectra on
the value of the baryon-to-photon ratio $\eta$ at the period of primordial
nucleosynthesis is investigated. The observations of these antineutrinos will
allow us to look directly at the very early Universe and nonequilibrium
processes taken place before, during, and some time after primordial
nucleosynthesis. In any case, this phenomenon is one more aspect in the picture
of the standard cosmological model.
[2]
oai:arXiv.org:1809.03349 [pdf] - 1761047
Relic neutrinos: Antineutrinos of Primordial Nucleosynthesis
Submitted: 2018-09-10
For the first time the antineutrino spectrum formed as a result of neutron
and tritium decays during the epoch of primordial nucleosynthesis is
calculated. This spectrum is a non-thermal increase in addition to the standard
cosmic neutrino background (C$\nu$B) whose thermal spectrum was formed before
the beginning of primordial nucleosynthesis. For energy larger than
$10^{-2}\,$eV the calculated non-thermal antineutrino flux exceeds the C$\nu$B
spectrum and there are no other comparable sources of antineutrino in this
range. The observations of these antineutrinos will allow us to look directly
at the very early Universe and non-equilibrium processes taken place before,
during, and some time after primordial nucleosynthesis.
[3]
oai:arXiv.org:1101.2048 [pdf] - 1453873
Planck early results. VI. The High Frequency Instrument data processing
Planck HFI Core Team;
Ade, P. A. R.;
Aghanim, N.;
Ansari, R.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Banday, A. J.;
Bartelmann, M.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bock, J. J.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Boulanger, F.;
Bradshaw, T.;
Bucher, M.;
Cardoso, J. -F.;
Castex, G.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Chary, R. -R.;
Chen, X.;
Chiang, C.;
Church, S.;
Clements, D. L.;
Colley, J. -M.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Cressiot, C.;
Crill, B. P.;
Crook, M.;
de Bernardis, P.;
Delabrouille, J.;
Delouis, J. -M.;
Désert, F. -X.;
Dolag, K.;
Dole, H.;
Doré, O.;
Douspis, M.;
Dunkley, J.;
Efstathiou, G.;
Filliard, C.;
Forni, O.;
Fosalba, P.;
Ganga, K.;
Giard, M.;
Girard, D.;
Giraud-Héraud, Y.;
Gispert, R.;
Górski, K. M.;
Gratton, S.;
Griffin, M.;
Guyot, G.;
Haissinski, J.;
Harrison, D.;
Helou, G.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Hildebrandt, S. R.;
Hills, R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Huffenberger, K. M.;
Jaffe, A. H.;
Jones, W. C.;
Kaplan, J.;
Kneissl, R.;
Knox, L.;
Kunz, M.;
Lagache, G.;
Lamarre, J. -M.;
Lange, A. E.;
Lasenby, A.;
Lavabre, A.;
Lawrence, C. R.;
Jeune, M. Le;
Leroy, C.;
Lesgourgues, J.;
Lewis, A.;
Macías-Pérez, J. F.;
MacTavish, C. J.;
Maffei, B.;
Mandolesi, N.;
Mann, R.;
Marleau, F.;
Marshall, D. J.;
Masi, S.;
Matsumura, T.;
McAuley, I.;
McGehee, P.;
Melin, J. -B.;
Mercier, C.;
Mitra, S.;
Miville-Deschênes, M. -A.;
Moneti, A.;
Montier, L.;
Mortlock, D.;
Murphy, A.;
Nati, F.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
North, C.;
Noviello, F.;
Novikov, D.;
Osborne, S.;
Pajot, F.;
Patanchon, G.;
Peacocke, T.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Pointecouteau, E.;
Ponthieu, N.;
Prézeau, G.;
Prunet, S.;
Puget, J. -L.;
Reach, W. T.;
Remazeilles, M.;
Renault, C.;
Riazuelo, A.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Roudier, G.;
Rowan-Robinson, M.;
Rusholme, B.;
Saha, R.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Shellard, P.;
Spencer, L.;
Starck, J. -L.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sunyaev, R.;
Sutton, D.;
Sygnet, J. -F.;
Tauber, J. A.;
Thum, C.;
Torre, J. -P.;
Touze, F.;
Tristram, M.;
Van Leeuwen, F.;
Vibert, L.;
Vibert, D.;
Wandelt, B. D.;
White, S. D. M.;
Wiesemeyer, H.;
Woodcraft, A.;
Yurchenko, V.;
Yvon, D.;
Zacchei, A.
Submitted: 2011-01-11, last modified: 2011-12-23
We describe the processing of the 336 billion raw data samples from the High
Frequency Instrument (HFI) which we performed to produce six temperature maps
from the first 295 days of Planck-HFI survey data. These maps provide an
accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz
with an angular resolution ranging from 9.9 to 4.4^2. The white noise level is
around 1.5 {\mu}K degree or less in the 3 main CMB channels (100--217GHz). The
photometric accuracy is better than 2% at frequencies between 100 and 353 GHz
and around 7% at the two highest frequencies. The maps created by the HFI Data
Processing Centre reach our goals in terms of sensitivity, resolution, and
photometric accuracy. They are already sufficiently accurate and
well-characterised to allow scientific analyses which are presented in an
accompanying series of early papers. At this stage, HFI data appears to be of
high quality and we expect that with further refinements of the data processing
we should be able to achieve, or exceed, the science goals of the Planck
project.
[4]
oai:arXiv.org:1101.2039 [pdf] - 1051324
Planck early results: first assessment of the High Frequency Instrument
in-flight performance
Planck HFI Core Team;
Ade, P. A. R.;
Aghanim, N.;
Ansari, R.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Banday, A. J.;
Bartelmann, M.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Benot, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Boulanger, F.;
Bradshaw, T.;
Brelle, E.;
Bucher, M.;
Camus, P.;
Cardoso, J. -F.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Charra, M.;
Chary, R. -R.;
Chiang, C.;
Church, S.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Cressiot, C.;
Crill, B. P.;
Crook, M.;
de Bernardis, P.;
Delabrouille, J.;
Delouis, J. -M.;
Désert, F. -X.;
Dolag, K.;
Dole, H.;
Doré, O.;
Douspis, M.;
Efstathiou, G.;
Eng, P.;
Filliard, C.;
Forni, O.;
Fosalba, P.;
Fourmond, J. -J.;
Ganga, K.;
Giard, M.;
Girard, D.;
Giraud-Héraud, Y.;
Gispert, R.;
Gorski, K. M.;
Gratton, S.;
Griffin, M.;
Guyot, G.;
Haissinski, J.;
Harrison, D.;
Helou, G.;
Henrot-Versillé, S.;
Hernandez-Monteagudo, C.;
Hildebrandt, S. R.;
Hills, R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Huenberger, K. M.;
Jae, A. H.;
Jones, W. C.;
Kaplan, J.;
Kneissl, R.;
Knox, L.;
Lagache, G.;
Lamarre, J. -M.;
Lami, P.;
Lange, A. E.;
Lasenby, A.;
Lavabre, A.;
Lawrence, C. R.;
Leriche, B.;
Leroy, C.;
Longval, Y.;
Macas-Perez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maei, B.;
Mandolesi, N.;
Mann, R.;
Mansoux, B.;
Masi, S.;
Matsumura, T.;
McGehee, P.;
Melin, J. -B.;
Mercier, C.;
Miville-Deschnes, M. -A.;
Moneti, A.;
Montier, L.;
Mortlock, D.;
Murphy, A.;
Nati, F.;
Nettereld, C. B.;
Norgaard-Nielsen, H. U.;
North, C.;
Noviello, F.;
Novikov, D.;
Osborne, S.;
Paine, C.;
Pajot, F.;
Patanchon, G.;
Peacocke, T.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Piacentini, F.;
Piat, M.;
Plaszczynski, S.;
Pointecouteau, E.;
Pons, R.;
Ponthieu, N.;
Prezeau, G.;
Prunet, S.;
Puget, J. -L.;
Reach, W. T.;
Renault, C.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Roudier, G.;
Rowan-Robinson, M.;
Rusholme, B.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Shellard, P.;
Spencer, L.;
Starck, J. -L.;
Stassi, P.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tauber, J. A.;
Thum, C.;
Torre, J. -P.;
Touze, F.;
Tristram, M.;
Van Leeuwen, F.;
Vibert, L.;
Vibert, D.;
Wade, L. A.;
Wandelt, B. D.;
White, S. D. M.;
Wiesemeyer, H.;
Woodcraft, A.;
Yurchenko, V.;
Yvon, D.;
Zacchei, A.
Submitted: 2011-01-11
The Planck High Frequency Instrument (HFI) is designed to measure the
temperature and polarization anisotropies of the Cosmic Microwave Background
and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545
and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5'
(217 GHz and higher). HFI has been operating flawlessly since launch on 14 May
2009. The bolometers cooled to 100 mK as planned. The settings of the readout
electronics, such as the bolometer bias current, that optimize HFI's noise
performance on orbit are nearly the same as the ones chosen during ground
testing. Observations of Mars, Jupiter, and Saturn verified both the optical
system and the time response of the detection chains. The optical beams are
close to predictions from physical optics modeling. The time response of the
detection chains is close to pre-launch measurements. The detectors suffer from
an unexpected high flux of cosmic rays related to low solar activity. Due to
the redundancy of Planck's observations strategy, the removal of a few percent
of data contaminated by glitches does not affect significantly the sensitivity.
The cosmic rays heat up significantly the bolometer plate and the modulation on
periods of days to months of the heat load creates a common drift of all
bolometer signals which do not affect the scientific capabilities. Only the
high energy cosmic rays showers induce inhomogeneous heating which is a
probable source of low frequency noise.
[5]
oai:arXiv.org:astro-ph/0410544 [pdf] - 1456397
Beam mismatch effects in Cosmic Microwave Background polarization
measurements
Submitted: 2004-10-22, last modified: 2006-12-08
Measurement of cosmic microwave background polarization is today a major goal
of observational cosmology. The level of the signal to measure, however, makes
it very sensitive to various systematic effects. In the case of Planck, which
measures polarization by combining data from various detectors, the beam
asymmetry can induce a temperature leakage or a polarization mode mixing. In
this paper, we investigate this effect using realistic simulated beams and
propose a first-order method to correct the polarization power spectra for the
induced systematic effect.
[6]
oai:arXiv.org:astro-ph/0606122 [pdf] - 82562
PTD vs. PO effects in power and polarisation of PLANCK HFI 100 beams
Submitted: 2006-06-06
A method of accelerated computation of broadband far off boresight patterns
of telescope beams is extended and applied to the 100 GHz channels of Planck
HFI (HFI 100). Far off boresight angle power patterns are computed with both
GRASP PTD and NUIM PO software, considering cuts with an angular size of 10
degrees. The former reveal secondary oscillations of radial power distribution
as compared with the latter. The difference for power patterns of a/b
polarisation channels is also investigated.
[7]
oai:arXiv.org:astro-ph/0411642 [pdf] - 69241
Ultrafast multireflector physical-optics beam simulations for the HFI
instrument on the ESA PLANCK Surveyor
Submitted: 2004-11-23
We present the latest results of our fast physical optics simulations of the
ESA PLANCK HFI beams. The main beams of both polarized and non-polarized
channels have been computed with account of broad frequency bands for the final
design and positions of the HFI horns. Gaussian fitting parameters of the
broadband beams have been presented. Beam polarization characteristics and horn
defocusing effects have been studied.
[8]
oai:arXiv.org:astro-ph/0308075 [pdf] - 1233196
The Planck High Frequency Instrument, a 3rd generation CMB experiment,
and a full sky submillimeter survey
Lamarre, J. M.;
Puget, J. L.;
Bouchet, F.;
Ade, P. A. R.;
Benoit, A.;
Bernard, J. P.;
Bock, J.;
De Bernardis, P.;
Charra, J.;
Couchot, F.;
Delabrouille, J.;
Efstathiou, G.;
Giard, M.;
Guyot, G.;
Lange, A.;
Maffei, B.;
Murphy, A.;
Pajot, F.;
Piat, M.;
Ristorcelli, I.;
Santos, D.;
Sudiwala, R.;
Sygnet, J. F.;
Torre, J. P.;
Yurchenko, V.;
Yvon, D.
Submitted: 2003-08-05
The High Frequency Instrument (HFI) of Planck is the most sensitive CMB
experiment ever planned. Statistical fluctuations (photon noise) of the CMB
itself will be the major limitation to the sensitivity of the CMB channels.
Higher frequency channels will measure galactic foregrounds. Together with the
Low Frequency Instrument, this will make a unique tool to measure the full sky
and to separate the various components of its spectrum. Measurement of the
polarization of these various components will give a new picture of the CMB. In
addition, HFI will provide the scientific community with new full sky maps of
intensity and polarization at six frequencies, with unprecedented angular
resolution and sensitivity. This paper describes the logics that prevailed to
define the HFI and the performances expected from this instrument. It details
several features of the HFI design that have not been published up to now.
[9]
oai:arXiv.org:astro-ph/0205269 [pdf] - 49343
Optimization of the Coupling of High-Frequency Horn Antenna Array to the
ESA PLANCK Submillimeter-Wave Telescope
Submitted: 2002-05-16
We study the electromagnetic coupling of the array of Gaussian and
multi-moded horn antennas to the dual-reflector submillimeter-wave telescope on
the ESA PLANCK Surveyor designed for measuring the temperature anisotropies and
polarization characteristics of the cosmic microwave background. In this paper,
we present the results of our analysis concerning the measurement of
polarization with tilted off-axis dual-reflector Gregorian telescope and the
propagation of multi-moded beams through such a system.
[10]
oai:arXiv.org:astro-ph/0205262 [pdf] - 277190
Measuring CMB Polarization with ESA PLANCK SubMM-Wave Telescope
Submitted: 2002-05-16
We analyze the polarization properties of the tilted off-axis dual-reflector
submillimeter-wave telescope on the ESA PLANCK Surveyor designed for measuring
the temperature anisotropies and polarization characteristics of the cosmic
microwave background.
[11]
oai:arXiv.org:astro-ph/0111067 [pdf] - 880567
Systematics of Microwave Polarimetry with the Planck LFI
Submitted: 2001-11-04, last modified: 2002-01-07
The Planck Low Frequency Instrument will recover polarization by differencing
the outputs from radiometers sensitive to orthogonal polarizations. We contrast
the systematic errors that afflict such a system with those that affect
correlation polarimeters; the Planck design has some important advantages when
measuring very weak signals such as the CMB. We also review systematic effects
arising from the choice of scan strategy for all-sky mapping missions like
Planck.[For the Planck-LFI consortium].