Normalized to: Yellin, S.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[4]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[5]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[6]
oai:arXiv.org:1803.02903 [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Baker, W.;
Balakishiyeva, D.;
Banik, S.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chagani, H.;
Chang, Y. -Y.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Doughty, T.;
Dragowsky, E. M.;
Esteban, L.;
Fallows, S.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Holmgren, D.;
Hong, Z.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
McCarthy, K. A.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Moore, D.;
Mendoza, J. D. Morales;
Nelson, J.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Martinez, M. Penalver;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Rogers, H. E.;
Robinson, A. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Di Stefano, P. C. F.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
[7]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[8]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[9]
oai:arXiv.org:1503.03379 [pdf] - 1458536
Dark matter effective field theory scattering in direct detection
experiments
Schneck, K.;
Cabrera, B.;
Cerdeno, D. G.;
Mandic, V.;
Rogers, H. E.;
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Caldwell, D. O.;
Calkins, R.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D. M.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
[10]
oai:arXiv.org:1509.02448 [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Asai, M.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Underwood, R.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[11]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[12]
oai:arXiv.org:1409.3270 [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge
less than $e/6$
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, H.;
Nelson, R. H.;
Ogburn, R. W.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
[13]
oai:arXiv.org:1410.1003 [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Graham, M.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, R. H.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
[14]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
[15]
oai:arXiv.org:1309.3259 [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted
Calorimetric Ionization Detection in the SuperCDMS Experiment
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.
[16]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[17]
oai:arXiv.org:1305.2405 [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium
Detectors for Dark Matter Searches
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hasi, J.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S. A.;
Kennedy, A.;
Kenney, C. J.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Radpour, R.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for
dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric
sensors on opposite sides measure both charge and phonons from each particle
interaction, providing excellent discrimination between electron and nuclear
recoils, and between surface and interior events. Surface event rejection
capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta
decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal
region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L.,
corresponding to $< 0.6$ surface event background in the future 200-kg
SuperCDMS SNOLAB experiment.
[18]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[19]
oai:arXiv.org:1203.1309 [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Anderson, A. J.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dragowsky, M. R.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D. C.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D.;
Serfass, B.;
Speller, D.;
Sundqvist, K. M.;
Tarka, M.;
Thakur, R. B.;
Villano, A. N.;
Welliver, B.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
[20]
oai:arXiv.org:1201.3685 [pdf] - 1093064
Low-Mass WIMP Sensitivity and Statistical Discrimination of Electron and
Nuclear Recoils by Varying Luke-Neganov Phonon Gain in Semiconductor
Detectors
Submitted: 2012-01-17
Amplifying the phonon signal in a semiconductor dark matter detector can be
accomplished by operating at high voltage bias and converting the electrostatic
potential energy into Luke-Neganov phonons. This amplification method has been
validated at up to |E|=40V/cm without producing leakage in CDMSII Ge detectors,
allowing sensitivity to a benchmark WIMP with mass = 8GeV and cross section
1.8e-42cm^2 assuming flat electronic recoil backgrounds near threshold.
Furthermore, for the first time we show that differences in Luke-Neganov gain
for nuclear and electronic recoils can be used to discriminate statistically
between low-energy background and a hypothetical WIMP signal by operating at
two distinct voltage biases. Specifically, 99% of events have p-value<1e-8 for
a simulated 20kg-day experiment with a benchmark WIMP signal with mass =8GeV
and cross section =3.3e-41cm^2.
[21]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[22]
oai:arXiv.org:1012.5078 [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Razeti, M.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
[23]
oai:arXiv.org:1011.2482 [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
[24]
oai:arXiv.org:1010.4290 [pdf] - 286319
Low-threshold analysis of CDMS shallow-site data
CDMS Collaboration;
Akerib, D. S.;
Attisha, M. J.;
Baudis, L.;
Bauer, D. A.;
Bolozdynya, A. I.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Chang, C. L.;
Clarke, R. M.;
Cooley, J.;
Crisler, M. B.;
Cushman, P.;
DeJongh, F.;
Dixon, R.;
Driscoll, D. D.;
Filippini, J.;
Funkhouser, S.;
Gaitskell, R. J.;
Golwala, S. R.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamat, S.;
Mahapatra, R.;
Mandic, V.;
Meunier, P.;
Mirabolfathi, N.;
Moore, D.;
Nam, S. W.;
Nelson, H.;
Ogburn, R. W.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Savage, C.;
Schnee, R. W.;
Seitz, D. N.;
Shutt, T. A.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.
Submitted: 2010-10-20, last modified: 2011-01-03
Data taken during the final shallow-site run of the first tower of the
Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with
improved sensitivity to small energy depositions. Four ~224 g germanium and two
~105 g silicon detectors were operated at the Stanford Underground Facility
(SUF) between December 2001 and June 2002, yielding 118 live days of raw
exposure. Three of the germanium and both silicon detectors were analyzed with
a new low-threshold technique, making it possible to lower the germanium and
silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and
~2 keV, respectively. Limits on the spin-independent cross section for weakly
interacting massive particles (WIMPs) to elastically scatter from nuclei based
on these data exclude interesting parameter space for WIMPs with masses below 9
GeV/c^2. Under standard halo assumptions, these data partially exclude
parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT
experiments' data as WIMP signals, and exclude new parameter space for WIMP
masses between 3 GeV/c^2 and 4 GeV/c^2.
[25]
oai:arXiv.org:0907.1438 [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS
experiment
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Beaty, J.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
DeJongh, F.;
Dragowsky, M. R.;
Duong, L.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fritts, M.;
Golwala, S. R.;
Grant, D. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Mahapatra, R.;
Mandic, V.;
Moore, D.;
McCarthy, K. A.;
Mirabolfathi, N.;
Nelson, H.;
Ogburn, R. W.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Collaboration, the CDMS
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.
[26]
oai:arXiv.org:astro-ph/0503583 [pdf] - 880834
Beyond the CDMS-II Dark Matter Search: SuperCDMS
Brink, P. L.;
Cabrera, B.;
Chang, C. L.;
Cooley, J.;
Ogburn, R. W.;
Akerib, D. S.;
Bailey, C. N.;
Brusov, P. P.;
Dragowsky, M. R.;
Grant, D. R.;
Hennings-Yeomans, R.;
Schnee, R. W.;
Attisha, M. J.;
Gaitskell, R. J.;
Thompson, J-P. F.;
Baudis, L.;
Saab, T.;
Bauer, D. A.;
Crisler, M. B.;
Holmgren, D.;
Ramberg, E.;
Yoo, J.;
Bunker, R.;
Caldwell, D. O.;
Mahapatra, R.;
Nelson, H.;
Sander, J.;
Yellin, S.;
Cushman, P.;
Duong, L.;
Reisetter, A.;
Denes, P.;
Lu, A.;
Sadoulet, B.;
Filippini, J.;
Meunier, P.;
Mirabolfathi, N.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Golwala, S. R.;
Huber, M. E.;
Irwin, K. D.;
Young, B. A.
Submitted: 2005-03-27
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle
(WIMP) search at the Soudan Underground Laboratory sets the most stringent
exclusion limits of any WIMP cold dark matter direct-detection experiment. To
extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46}
- 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very
deep site. One promising site is the recently approved SNOLab facility in
Canada. In this paper we will present our overall plan, identify primary
issues, and set the goals that need to be met prior to embarking upon each
phase of SuperCDMS.
[27]
oai:arXiv.org:astro-ph/9712343 [pdf] - 99832
Preliminary Limits on the WIMP-Nucleon Cross Section from the Cryogenic
Dark Matter Search (CDMS)
Akerib, DS;
Barnes, PD;
Bauer, DA;
Brink, PL;
Cabrera, B;
Caldwell, DO;
Clarke, RM;
Da Silva, A;
Davies, AK;
Dougherty, BL;
Irwin, KD;
Gaitskell, RJ;
Golwala, SR;
Haller, EE;
Jochum, J;
Knowlton, WB;
Kuzminov, V;
Nam, SW;
Novikov, V;
Penn, MJ;
Perera, TA;
Ross, RR;
Sadoulet, B;
Schnee, RW;
Shutt, T;
Smith, A;
Sonnenschein, AH;
Spadafora, AL;
Stockwell, WK;
Yellin, S;
Young, BA
Submitted: 1997-12-30
We are conducting an experiment to search for WIMPs, or weakly-interacting
massive particles, in the galactic halo using terrestrial detectors. This
generic class of hypothetical particles, whose properties are similar to those
predicted by extensions of the standard model of particle physics, could
comprise the cold component of non-baryonic dark matter. We describe our
experiment, which is based on cooled germanium and silicon detectors in a
shielded low-background cryostat. The detectors achieve a high degree of
background rejection through the simultaneous measurement of the energy in
phonons and ionization. Using exposures on the order of one kilogram-day from
initial runs of our experiment, we have achieved (preliminary) upper limits on
the WIMP-nucleon cross section that are comparable to much longer runs of other
experiments.