Normalized to: Ycas, G.
[1]
oai:arXiv.org:1902.00500 [pdf] - 1840780
Stellar Spectroscopy in the Near-infrared with a Laser Frequency Comb
Metcalf, Andrew J.;
Anderson, Tyler;
Bender, Chad F.;
Blakeslee, Scott;
Brand, Wesley;
Carlson, David R.;
Cochran, William D.;
Diddams, Scott A.;
Endl, Michael;
Fredrick, Connor;
Halverson, Sam;
Hickstein, Dan D.;
Hearty, Fred;
Jennings, Jeff;
Kanodia, Shubham;
Kaplan, Kyle F.;
Levi, Eric;
Lubar, Emily;
Mahadevan, Suvrath;
Monson, Andrew;
Ninan, Joe P.;
Nitroy, Colin;
Osterman, Steve;
Papp, Scott B.;
Quinlan, Franklyn;
Ramsey, Larry;
Robertson, Paul;
Roy, Arpita;
Schwab, Christian;
Sigurdsson, Steinn;
Srinivasan, Kartik;
Stefansson, Gudmundur;
Sterner, David A.;
Terrien, Ryan;
Wolszczan, Alex;
Wright, Jason T.;
Ycas, Gabriel
Submitted: 2019-02-01
The discovery and characterization of exoplanets around nearby stars is
driven by profound scientific questions about the uniqueness of Earth and our
Solar System, and the conditions under which life could exist elsewhere in our
Galaxy. Doppler spectroscopy, or the radial velocity (RV) technique, has been
used extensively to identify hundreds of exoplanets, but with notable
challenges in detecting terrestrial mass planets orbiting within habitable
zones. We describe infrared RV spectroscopy at the 10 m Hobby-Eberly telescope
that leverages a 30 GHz electro-optic laser frequency comb with nanophotonic
supercontinuum to calibrate the Habitable Zone Planet Finder spectrograph.
Demonstrated instrument precision <10 cm/s and stellar RVs approaching 1 m/s
open the path to discovery and confirmation of habitable zone planets around
M-dwarfs, the most ubiquitous type of stars in our Galaxy.
[2]
oai:arXiv.org:1703.00001 [pdf] - 1581684
Frequency stability characterization of a broadband fiber Fabry-Perot
interferometer
Submitted: 2017-02-27, last modified: 2017-06-17
An optical etalon illuminated by a white light source provides a broadband
comb-like spectrum that can be employed as a calibration source for
astronomical spectrographs in radial velocity (RV) surveys for extrasolar
planets. For this application the frequency stability of the etalon is
critical, as its transmission spectrum is susceptible to frequency fluctuations
due to changes in cavity temperature, optical power and input polarization. In
this paper we present a laser frequency comb measurement technique to
characterize the frequency stability of a custom-designed fiber Fabry-Perot
interferometer (FFP). Simultaneously probing the stability of two etalon
resonance modes, we assess both the absolute stability of the etalon and the
long-term stability of the cavity dispersion. We measure mode positions with
MHz precision, which corresponds to splitting the FFP resonances by a part in
500 and to RV precision of ~1 m/s. We address limiting systematic effects,
including the presence of parasitic etalons, that need to be overcome to push
the metrology of this system to the equivalent RV precision of 10 cm/s. Our
results demonstrate a means to characterize environmentally-driven
perturbations of etalon resonance modes across broad spectral bandwidths, as
well as motivate the benefits and challenges of FFPs as spectrograph
calibrators.
[3]
oai:arXiv.org:1501.02509 [pdf] - 1418694
Demonstration of a Near-IR Laser Comb for Precision Radial Velocity
Measurements in Astronomy
Yi, X.;
Vahala, K.;
Diddams, S.;
Ycas, G.;
Plavchan, P.;
Leifer, S.;
Sandhu, J.;
Vasisht, G.;
Chen, P.;
Gao, P.;
Gagne, J.;
Furlan, E.;
Bottom, M.;
Martin, E.;
Fitzgerald, M.;
Doppmann, G.;
Beichman, C.
Submitted: 2015-01-11
We describe a successful effort to produce a laser comb around 1.55 $\mu$m in
the astronomical H band using a method based on a line-referenced,
electro-optical-modulation frequency comb. We discuss the experimental setup,
laboratory results, and proof of concept demonstrations at the NASA Infrared
Telescope Facility (IRTF) and the Keck-II telescope. The laser comb has a
demonstrated stability of $<$ 200 kHz, corresponding to a Doppler precision of
~0.3 m/s. This technology, when coupled with a high spectral resolution
spectrograph, offers the promise of $<$1 m/s radial velocity precision suitable
for the detection of Earth-sized planets in the habitable zones of cool M-type
stars.
[4]
oai:arXiv.org:1408.3632 [pdf] - 863580
The Habitable-zone Planet Finder Calibration System
Halverson, Samuel;
Mahadevan, Suvrath;
Ramsey, Lawrence;
Terrien, Ryan;
Roy, Arpita;
Schwab, Christian;
Bender, Chad;
Hearty, Fred;
Levi, Eric;
Osterman, Steve;
Ycas, Gabe;
Diddams, Scott
Submitted: 2014-08-15
We present the design concept of the wavelength calibration system for the
Habitable-zone Planet Finder instrument (HPF), a precision radial velocity (RV)
spectrograph designed to detect terrestrial-mass planets around M-dwarfs. HPF
is a stabilized, fiber-fed, R$\sim$50,000 spectrograph operating in the
near-infrared (NIR) z/Y/J bands from 0.84 to 1.3 microns. For HPF to achieve 1
m s$^{-1}$ or better measurement precision, a unique calibration system, stable
to several times better precision, will be needed to accurately remove
instrumental effects at an unprecedented level in the NIR. The primary
wavelength calibration source is a laser frequency comb (LFC), currently in
development at NIST Boulder, discussed separately in these proceedings. The LFC
will be supplemented by a stabilized single-mode fiber Fabry-Perot
interferometer reference source and Uranium-Neon lamp. The HPF calibration
system will combine several other new technologies developed by the Penn State
Optical-Infrared instrumentation group to improve RV measurement precision
including a dynamic optical coupling system that significantly reduces modal
noise effects. Each component has been thoroughly tested in the laboratory and
has demonstrated significant performance gains over previous NIR calibration
systems.
[5]
oai:arXiv.org:1202.1855 [pdf] - 730988
Generation of a 650 nm - 2000 nm Laser Frequency Comb based on an
Erbium-Doped Fiber Laser
Submitted: 2012-02-08, last modified: 2013-10-09
We present a laser frequency comb based upon a 250 MHz mode-locked
erbium-doped fiber laser that spans more than 300 terahertz of bandwidth, from
660 nm to 2000 nm. The system generates 1.2 nJ, 70 fs pulses at 1050 nm by
amplifying the 1580 nm laser light in Er:fiber, followed by nonlinear
broadening to 1050 nm and amplification in Yb:fiber. Extension of the frequency
comb into the visible is achieved by supercontinuum generation from the 1050 nm
light. Comb coherence is verified with cascaded f-2f interferometry and
comparison to a frequency stabilized laser.
[6]
oai:arXiv.org:1209.3295 [pdf] - 1151415
A near infrared frequency comb for Y+J band astronomical spectroscopy
Osterman, Steve;
Ycas, Gabriel G.;
Diddams, Scott A.;
Quinlan, Franklyn;
Mahadevan, Suvrath;
Ramsey, Lawrence;
Bender, Chad F.;
Terrien, Ryan;
Botzer, Brandon;
Sigurddson, Steinn;
Redman, Stephen L.
Submitted: 2012-09-14
Radial velocity (RV) surveys supported by high precision wavelength
references (notably ThAr lamps and I2 cells) have successfully identified
hundreds of exoplanets; however, as the search for exoplanets moves to cooler,
lower mass stars, the optimum wave band for observation for these objects moves
into the near infrared (NIR) and new wavelength standards are required. To
address this need we are following up our successful deployment of an H
band(1.45-1.7{\mu}m) laser frequency comb based wavelength reference with a
comb working in the Y and J bands (0.98-1.3{\mu}m). This comb will be optimized
for use with a 50,000 resolution NIR spectrograph such as the Penn State
Habitable Zone Planet Finder. We present design and performance details of the
current Y+J band comb.
[7]
oai:arXiv.org:1201.5125 [pdf] - 496339
Demonstration of On-Sky Calibration of Astronomical Spectra using a 25
GHz near-IR Laser Frequency Comb
Ycas, Gabriel G.;
Quinlan, Franklyn;
Diddams, Scott A.;
Osterman, Steve;
Mahadevan, Suvrath;
Redman, Stephen;
Terrien, Ryan;
Ramsey, Lawrence;
Bender, Chad F.;
Botzer, Brandon;
Sigurdsson, Steinn
Submitted: 2012-01-23, last modified: 2012-04-04
We describe and characterize a 25 GHz laser frequency comb based on a
cavity-filtered erbium fiber mode-locked laser. The comb provides a uniform
array of optical frequencies spanning 1450 nm to 1700 nm, and is stabilized by
use of a global positioning system referenced atomic clock. This comb was
deployed at the 9.2 m Hobby-Eberly telescope at the McDonald Observatory where
it was used as a radial velocity calibration source for the fiber-fed
Pathfinder near-infrared spectrograph. Stellar targets were observed in three
echelle orders over four nights, and radial velocity precision of \sim10 m/s
(\sim6 MHz) was achieved from the comb-calibrated spectra.
[8]
oai:arXiv.org:1112.1062 [pdf] - 1092165
A High-Resolution Atlas of Uranium-Neon in the H Band
Redman, Stephen L.;
Ycas, Gabriel G.;
Terrien, Ryan;
Mahadevan, Suvrath;
Ramsey, Lawrence W.;
Bender, Chad F.;
Osterman, Steven N.;
Diddams, Scott A.;
Quinlan, Franklyn;
Lawler, James E.;
Nave, Gillian
Submitted: 2011-12-05
We present a high-resolution (R ~ 50 000) atlas of a uranium-neon (U/Ne)
hollow-cathode spectrum in the H-band (1454 nm to 1638 nm) for the calibration
of near-infrared spectrographs. We obtained this U/Ne spectrum simultaneously
with a laser-frequency comb spectrum, which we used to provide a first-order
calibration to the U/Ne spectrum. We then calibrated the U/Ne spectrum using
the recently-published uranium line list of Redman et al. (2011), which is
derived from high-resolution Fourier transform spectrometer measurements. These
two independent calibrations allowed us to easily identify emission lines in
the hollow cathode lamp that do not correspond to known (classified) lines of
either uranium or neon, and to compare the achievable precision of each source.
Our frequency comb precision was limited by modal noise and detector effects,
while the U/Ne precision was limited primarily by the signal-to-noise ratio
(S/N) of the observed emission lines and our ability to model blended lines.
The standard deviation in the dispersion solution residuals from the
S/N-limited U/Ne hollow cathode lamp were 50% larger than the standard
deviation of the dispersion solution residuals from the modal-noise-limited
laser frequency comb. We advocate the use of U/Ne lamps for precision
calibration of near-infrared spectrographs, and this H-band atlas makes these
lamps significantly easier to use for wavelength calibration.
[9]
oai:arXiv.org:1003.0136 [pdf] - 1025438
A Near Infrared Laser Frequency Comb for High Precision Doppler Planet
Surveys
Submitted: 2010-02-27
We discuss the laser frequency comb as a near infrared astronomical
wavelength reference, and describe progress towards a near infrared laser
frequency comb at the National Institute of Standards and Technology and at the
University of Colorado where we are operating a laser frequency comb suitable
for use with a high resolution H band astronomical spectrograph.