sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Yamaguchi, R.

Normalized to: Yamaguchi, R.

4 article(s) in total. 152 co-authors, from 1 to 4 common article(s). Median position in authors list is 55,5.

[1]  oai:arXiv.org:2001.01857  [pdf] - 2050347
A novel experimental setup for an oblique impact onto an inclined granular layer
Comments: 9 pages, 8 figures
Submitted: 2020-01-06
We develop an original apparatus of the granular impact experiment by which the incident angle of the solid projectile and inclination angle of the target granular layer can be systematically varied. Whereas most of the natural cratering events occur on inclined surfaces with various incident angles, there have not been any experiments on oblique impacts on an inclined target surface. To perform systematic impact experiments, a novel experimental apparatus has to be developed. Therefore, we build an apparatus for impact experiments where both the incident angle and the inclination angle can be independently varied. The projectile-injection unit accelerates a plastic ball (6~mm in diameter) up to $v_i\simeq 100$~m~s$^{-1}$ impact velocity. The barrel of the injection unit is made with a three-dimensional printer. The impact dynamics is captured by high-speed cameras to directly measure the impact velocity and incident angle. The rebound dynamics of the projectile (restitution coefficient and rebound angle) is also measured. The final crater shapes are measured using a line-laser profiler mounted on the electric stages. By scanning the surface using this system, a three-dimensional crater shape (height map) can be constructed. From the measured result, we can define and measure the characteristic quantities of the crater. The analyzed result on the restitution dynamics is presented as an example of systematic experiments using the developed system.
[2]  oai:arXiv.org:1811.10610  [pdf] - 1791586
Faraday Tomography with Sparse Modeling
Comments: 11 pages, 3 figures, submitted to the Astronomical Journal. No net change from v1; correcting a bug in the AASTEX tighten layout that partially removes a footnote
Submitted: 2018-11-26, last modified: 2018-11-29
Faraday tomography (or rotation measure synthesis) is a procedure to convert linear polarization spectra into the Faraday dispersion function, which provides us with unique information of magneto-ionic media along the line of sight. Mathematical formulation of Faraday tomography is similar to polarimetric imaging of radio interferometry, where many new methods have been actively developed and shown to outperform the standard CLEAN approaches. In this paper, we propose a sparse reconstruction technique to Faraday tomography. This technique is being developed for interferometric imaging and utilizes computationally less expensive convex regularization functions such as $\ell_1$-norm and total variation (TV) or total squared variation (TSV). The proposed technique solves a convex optimization, and therefore its solution is determined uniquely regardless of the initial condition for given regularization parameters that can be optimized by data themselves. Using a physically-motivated model of turbulent galactic magnetized plasma, we demonstrate that the proposed technique outperforms RM-CLEAN and provides higher-fidelity reconstruction. The proposed technique would be a powerful tool in broadband polarimetry with the Square Kilometre Array (SKA) and its precursors.
[3]  oai:arXiv.org:1601.04778  [pdf] - 1416351
Real-Time Supernova Neutrino Burst Monitor at Super-Kamiokande
Abe, K.; Haga, Y.; Hayato, Y.; Ikeda, M.; Iyogi, K.; Kameda, J.; Kishimoto, Y.; Miura, M.; Moriyama, S.; Nakahata, M.; Nakano, Y.; Nakayama, S.; Sekiya, H.; Shiozawa, M.; Suzuki, Y.; Takeda, A.; Tanaka, H.; Tomura, T.; Ueno, K.; Wendell, R. A.; Yokozawa, T.; Irvine, T.; Kajita, T.; Kametani, I.; Kaneyuki, K.; Lee, K. P.; McLachlan, T.; Nishimura, Y.; Richard, E.; Okumura, K.; Labarga, L.; Fernandez, P.; Berkman, S.; Tanaka, H. A.; Tobayama, S.; Gustafson, J.; Kearns, E.; Raaf, J. L.; Stone, J. L.; Sulak, L. R.; Goldhaber, M.; Carminati, G.; Kropp, W. R.; Mine, S.; Weatherly, P.; Renshaw, A.; Smy, M. B.; Sobel, H. W.; Takhistov, V.; Ganezer, K. S.; Hartfiel, B. L.; Hill, J.; Keig, W. E.; Hong, N.; Kim, J. Y.; Lim, I. T.; Akiri, T.; Himmel, A.; Scholberg, K.; Walter, C. W.; Wongjirad, T.; Ishizuka, T.; Tasaka, S.; Jang, J. S.; Learned, J. G.; Matsuno, S.; Smith, S. N.; Hasegawa, T.; Ishida, T.; Ishii, T.; Kobayashi, T.; Nakadaira, T.; Nakamura, K.; Oyama, Y.; Sakashita, K.; Sekiguchi, T.; Tsukamoto, T.; Suzuki, A. T.; Takeuchi, Y.; Bronner, C.; Hirota, S.; Huang, K.; Ieki, K.; Kikawa, T.; Minamino, A.; Murakami, A.; Nakaya, T.; Suzuki, K.; Takahashi, S.; Tateishi, K.; Fukuda, Y.; Choi, K.; Itow, Y.; Mitsuka, G.; Mijakowski, P.; Hignight, J.; Imber, J.; Jung, C. K.; Yanagisawa, C.; Wilking, M. J.; Ishino, H.; Kibayashi, A.; Koshio, Y.; Mori, T.; Sakuda, M.; Yamaguchi, R.; Yano, T.; Kuno, Y.; Tacik, R.; Kim, S. B.; Okazawa, H.; Choi, Y.; Nishijima, K.; Koshiba, M.; Suda, Y.; Totsuka, Y.; Yokoyama, M.; Martens, K.; Marti, Ll.; Vagins, M. R.; Martin, J. F.; de Perio, P.; Konaka, A.; Chen, S.; Zhang, Y.; Connolly, K.; Wilkes, R. J.
Comments: 15 pages, 8 figures, accepted for publication in Astroparticle Physics
Submitted: 2016-01-18, last modified: 2016-04-11
We present a real-time supernova neutrino burst monitor at Super-Kamiokande (SK). Detecting supernova explosions by neutrinos in real time is crucial for giving a clear picture of the explosion mechanism. Since the neutrinos are expected to come earlier than light, a fast broadcasting of the detection may give astronomers a chance to make electromagnetic radiation observations of the explosions right at the onset. The role of the monitor includes a fast announcement of the neutrino burst detection to the world and a determination of the supernova direction. We present the online neutrino burst detection system and studies of the direction determination accuracy based on simulations at SK.
[4]  oai:arXiv.org:1307.0162  [pdf] - 762222
Calibration of the Super-Kamiokande Detector
Abe, K.; Hayato, Y.; Iida, T.; Iyogi, K.; Kameda, J.; Kishimoto, Y.; Koshio, Y.; Marti, Ll.; Miura, M.; Moriyama, S.; Nakahata, M.; Nakano, Y.; Nakayama, S.; Obayashi, Y.; Sekiya, H.; Shiozawa, M.; Suzuki, Y.; Takeda, A.; Takenaga, Y.; Tanaka, H.; Tomura, T.; Ueno, K.; Wendell, R. A.; Yokozawa, T.; Irvine, T. J.; Kaji, H.; Kajita, T.; Kaneyuki, K.; Lee, K. P.; Nishimura, Y.; Okumura, K.; McLachlan, T.; Labarga, L.; Kearns, E.; Raaf, J. L.; Stone, J. L.; Sulak, L. R.; Berkman, S.; Tanaka, H. A.; Tobayama, S.; Goldhaber, M.; Bays, K.; Carminati, G.; Kropp, W. R.; Mine, S.; Renshaw, A.; Smy, M. B.; Sobel, H. W.; Ganezer, K. S.; Hill, J.; Keig, W. E.; Jang, J. S.; Kim, J. Y.; Lim, I. T.; Hong, N.; Akiri, T.; Albert, J. B.; Himmel, A.; Scholberg, K.; Walter, C. W.; Wongjirad, T.; Ishizuka, T.; Tasaka, S.; Learned, J. G.; Matsuno, S.; Smith, S. N.; Hasegawa, T.; Ishida, T.; Ishii, T.; Kobayashi, T.; Nakadaira, T.; Nakamura, K.; Nishikawa, K.; Oyama, Y.; Sakashita, K.; Sekiguchi, T.; Tsukamoto, T.; Suzuki, A. T.; Takeuchi, Y.; Huang, K.; Ieki, K.; Ikeda, M.; Kikawa, T.; Kubo, H.; Minamino, A.; Murakami, A.; Nakaya, T.; Otani, M.; Suzuki, K.; Takahashi, S.; Fukuda, Y.; Choi, K.; Itow, Y.; Mitsuka, G.; Miyake, M.; Mijakowski, P.; Tacik, R.; Hignight, J.; Imber, J.; Jung, C. K.; Taylor, I.; Yanagisawa, C.; Idehara, Y.; Ishino, H.; Kibayashi, A.; Mori, T.; Sakuda, M.; Yamaguchi, R.; Yano, T.; Kuno, Y.; Kim, S. B.; Yang, B. S.; Okazawa, H.; Choi, Y.; Nishijima, K.; Koshiba, M.; Totsuka, Y.; Yokoyama, M.; Martens, K.; Vagins, M. R.; Martin, J. F.; de Perio, P.; Konaka, A.; Wilking, M. J.; Chen, S.; Heng, Y.; Sui, H.; Yang, Z.; Zhang, H.; Zhenwei, Y.; Connolly, K.; Dziomba, M.; Wilkes, R. J.
Comments: 75 pages, 35 figures
Submitted: 2013-06-29, last modified: 2013-12-20
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret the digitized output of our electronics so that we can obtain physical numbers such as photon counts and their arrival times for each photomultiplier tube (PMT). In this context, we developed an in-situ procedure to determine high-voltage settings for PMTs in large detectors like SK, as well as a new method for measuring PMT quantum efficiency and gain in such a detector. The second part describes the modeling of the detector in our Monte Carlo simulation, including in particular the optical properties of its water target and their variability over time. Detailed studies on the water quality are also presented. As a result of this work, we achieved a precision sufficient for physics analysis over a wide energy range (from a few MeV to above a TeV). For example, the charge determination was understood at the 1% level, and the timing resolution was 2.1 nsec at the one-photoelectron charge level and 0.5 nsec at the 100-photoelectron charge level.