oai:arXiv.org:1711.07125 [pdf] - 1659596
Adaptive inversion algorithm for 1.5 um visibility lidar incorporating
in situ Angstrom wavelength exponent
Submitted: 2017-11-19
As one of the most popular applications of lidar systems, the atmospheric
visibility is defined to be inversely proportional to the atmospheric
extinction coefficient at 0.55 um. Since the laser at 1.5 um shows the highest
maximum permissible exposure in the wavelength ranging from 0.3 um to 10 um,
the eye-safe 1.5 um lidar can be deployed in urban areas. In such a case, the
measured extinction coefficient at 1.5 um should be converted to that at 0.55
um for visibility retrieval. Although several models have been established
since 1962, the accurate wavelength conversion remains a challenge. An adaptive
inversion algorithm for 1.5 um visibility lidar is proposed and demonstrated by
using the in situ Angstrom wavelength exponent, which is derived from either a
sun photometer or an aerosol spectrometer. The impact of the particle size
distribution of atmospheric aerosols and the Rayleigh backscattering of
atmospheric molecules are taken into account. In comparison, the Angstrom
wavelength exponent derived from the sun photometer is 7.7% higher than that
derived from the aerosol spectrometer. Then, using 1.5 um visibility lidar, the
visibility with a temporal resolution of 5 min is detected over 48 hours in
Hefei (31.83 N, 117.25 E). The average visibility error between the new method
and a visibility sensor (Vaisala, PWD52) is 5.2% with the R-square value of
0.96, while the relative error between another reference visibility lidar at
532 nm and the visibility sensor is 6.7% with the R-square value of 0.91. All
results agree with each other well, demonstrating the accuracy and stability of
the algorithm.
[2]
oai:arXiv.org:1706.02816 [pdf] - 1598059
Fully integrated free-running InGaAs/InP single-photon detector for
accurate lidar applications
Submitted: 2017-06-08
We present a fully integrated InGaAs/InP negative feedback avalanche diode
(NFAD) based free-running single-photon detector (SPD) designed for accurate
lidar applications. A free-piston Stirling cooler is used to cool down the NFAD
with a large temperature range, and an active hold-off circuit implemented in a
field programmable gate array is applied to further suppress the afterpulsing
contribution. The key parameters of the free-running SPD including photon
detection efficiency (PDE), dark count rate (DCR), afterpulse probability, and
maximum count rate (MCR) are dedicatedly optimized for lidar application in
practice. We then perform a field experiment using a Mie lidar system with 20
kHz pulse repetition frequency to compare the performance between the
free-running InGaAs/InP SPD and a commercial superconducting nanowire
single-photon detector (SNSPD). Our detector exhibits good performance with 1.6
Mcps MCR (0.6 {\mu}s hold-off time), 10% PDE, 950 cps DCR, and 18% afterpulse
probability over 50 {\mu}s period. Such performance is worse than the SNSPD
with 60% PDE and 300 cps DCR. However, after performing a specific algorithm
that we have developed for afterpulse and count rate corrections, the lidar
system performance in terms of range-corrected signal (Pr2) distribution using
our SPD agrees very well with the result using the SNSPD, with only a relative
error of ~2%. Due to the advantages of low-cost and small size of InGaAs/InP
NFADs, such detector provides a practical solution for accurate lidar
applications.
[3]
oai:arXiv.org:1606.04798 [pdf] - 1478832
All-fiber upconversion high spectral resolution wind lidar using a
Fabry-Perot interferometer
Submitted: 2016-06-15
An all-fiber, micro-pulse and eye-safe high spectral resolution wind lidar
(HSRWL) at 1550nm is proposed and demonstrated by using a pair of upconversion
single-photon detectors and a fiber Fabry-Perot scanning interferometer
(FFP-SI). In order to improve the optical detection efficiency, both the
transmission spectrum and the reflection spectrum of the FFP-SI are used for
spectral analyses of the aerosol backscatter and the reference laser pulse. The
reference signal is tapped from the outgoing laser and served as a zero
velocity indicator. The Doppler shift is retrieved from a frequency response
function Q, which is defined as the ratio of difference of the transmitted
signal and the reflected signal to their sum. Taking advantages of high
signal-to-noise ratio of the detectors and high spectral resolution of the
FFP-SI, the Q spectra of the aerosol backscatter are reconstructed along the
line-of-sight (LOS) of the telescope. By applying a least squares fit procedure
to the measured Q spectra, the center frequencies and the bandwidths are
obtained simultaneously. And then the Doppler shifts are determined relative to
the center frequency of the reference signal. To eliminate the influence of
temperature fluctuations on the FFP-SI, the FFP-SI is cased in a chamber with
temperature stability of 0.001 during the measurement. Continuous LOS wind
observations are carried out on two days at Hefei (31.843 N, 117.265 E), China.
In the meantime, LOS wind measurements from the HSRWL show good agreement with
the results from an ultrasonic wind sensor (Vaisala windcap WMT52). Due to the
computational expensive of the convolution operation of the Q function, an
empirical method is adopted to evaluate the quality of the measurements. The
standard deviation of the wind speed is 0.76 m/s at the 1.8 km. The standard
deviation of the retrieved bandwidth variation is 2.07 MHz at the 1.8 km.
[4]
oai:arXiv.org:1605.06736 [pdf] - 1521203
Micro-pulse upconversion Doppler lidar for wind and visibility detection
in the atmospheric boundary layer
Submitted: 2016-05-22
For the first time, a versatile, eyesafe, compact and direct detection
Doppler lidar is developed using upconversion single-photon detection method.
An all-fiber and polarization maintaining architecture is realized to guarantee
the high optical coupling efficiency and the system stability. Using
integrated-optic components, the conservation of etendue of the optical
receiver is achieved by manufacturing a fiber-coupled periodically poled
Lithium niobate waveguide and an all-fiber Fabry-Perot interferometer (FPI).
The so-called double-edge direct detection is implemented using a
single-channel FPI and a single upconversion detector, incorporating
time-division multiplexing method. The relative error of the system is lower
than 0.1% over 9 weeks. To show the robust of the system, atmospheric wind and
visibility over 48 hours are detected in the boundary layer. In the
intercomparison experiments, lidar shows good agreement with the ultrasonic
wind sensor (Vaisala windcap WMT52), with standard deviation of 1.04 m/s in
speed and 12.3{\deg} in direction.
[5]
oai:arXiv.org:0904.0062 [pdf] - 279792
Inflation with multiple sound speeds: a model of multiple DBI type
actions and non-Gaussianities
Submitted: 2009-04-01
In this letter we study adiabatic and isocurvature perturbations in the frame
of inflation with multiple sound speeds involved. We suggest this scenario can
be realized by a number of generalized scalar fields with arbitrary kinetic
forms. These scalars have their own sound speeds respectively, so the
propagations of field fluctuations are individual. Specifically, we study a
model constructed by two DBI type actions. We find that the critical length
scale for the freezing of perturbations corresponds to the maximum sound
horizon. Moreover, if the mass term of one field is much lighter than that of
the other, the entropy perturbation could be quite large and so may give rise
to a growth outside sound horizon. At cubic order, we find that the
non-Gaussianity of local type is possibly large when entropy perturbations are
able to convert into curvature perturbations. We also calculate the
non-Gaussianity of equilateral type approximately.