Normalized to: Xavier, P.
[1]
oai:arXiv.org:1509.00129 [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Sheinis, Andrew;
Anguiano, Borja;
Asplund, Martin;
Bacigalupo, Carlos;
Barden, Sam;
Birchall, Michael;
Bland-Hawthorn, Joss;
Brzeski, Jurek;
Cannon, Russell;
Carollo, Daniela;
Case, Scott;
Casey, Andrew;
Churilov, Vladimir;
Warrick, Couch;
Dean, Robert;
De Silva, Gayandhi;
D'Orazi, Valentina;
Duong, Ly;
Farrell, Tony;
Fiegert, Kristin;
Freeman, Kenneth;
Gabriella, Frost;
Gers, Luke;
Goodwin, Michael;
Gray, Doug;
Green, Andrew;
Heald, Ron;
Heijmans, Jeroen;
Ireland, Michael;
Jones, Damien;
Kafle, Prajwal;
Keller, Stefan;
Klauser, Urs;
Kondrat, Yuriy;
Kos, Janez;
Lawrence, Jon;
Lee, Steve;
Mali, Slavko;
Martell, Sarah;
Mathews, Darren;
Mayfield, Don;
Miziarski, Stan;
Muller, Rolf;
Pai, Naveen;
Patterson, Robert;
Penny, Ed;
Orr, David;
Schlesinger, Katharine;
Sharma, Sanjib;
Shortridge, Keith;
Simpson, Jeffrey;
Smedley, Scott;
Smith, Greg;
Stafford, Darren;
Staszak, Nicholas;
Vuong, Minh;
Waller, Lewis;
de Boer, Elizabeth Wylie;
Xavier, Pascal;
Zheng, Jessica;
Zhelem, Ross;
Zucker, Daniel;
Zwitter, Tomaz
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a
facility-class optical spectrograph for the Anglo-Australian Telescope (AAT).
It is designed primarily for Galactic Archaeology, the first major attempt to
create a detailed understanding of galaxy formation and evolution by studying
the history of our own galaxy, the Milky Way. The goal of the GALAH survey is
to reconstruct the mass assembly history of the Milky Way through a detailed
chemical abundance study of one million stars. The spectrograph is based at the
AAT and is fed by the existing 2dF robotic fiber positioning system. The
spectrograph uses volume phase holographic gratings to achieve a spectral
resolving power of 28,000 in standard mode and also provides a high-resolution
mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey
requires an SNR greater than 100 for a star brightness of V ?= 14 in an
exposure time of one hour. The total spectral coverage of the four channels is
about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within
the 2-degree field of view. HERMES has been commissioned over three runs,
during bright time in October, November, and December 2013, in parallel with
the beginning of the GALAH pilot survey, which started in November 2013. We
present the first-light results from the commissioning run and the beginning of
the GALAH survey, including performance results such as throughput and
resolution, as well as instrument reliability.
[2]
oai:arXiv.org:1407.6438 [pdf] - 1215881
PRAXIS: low thermal emission high efficiency OH suppressed fibre
spectrograph
Content, Robert;
Bland-Hawthorn, Joss;
Ellis, Simon;
Gers, Luke;
Haynes, Roger;
Horton, Anthony;
Lawrence, Jon;
Leon-Saval, Sergio;
Lindley, Emma;
Min, Seong-Sik;
Shortridge, Keith;
Staszak, Nick;
Trinh, Christopher;
Xavier, Pascal;
Zhelem, Ross
Submitted: 2014-07-23, last modified: 2014-07-29
PRAXIS is a second generation instrument that follows on from GNOSIS, which
was the first instrument using fibre Bragg gratings for OH background
suppression. The Bragg gratings reflect the NIR OH lines while being
transparent to light between the lines. This gives a much higher signal-noise
ratio at low resolution but also at higher resolutions by removing the
scattered wings of the OH lines. The specifications call for high throughput
and very low thermal and detector noise so that PRAXIS will remain sky noise
limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the
Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the
pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph
specifically designed for the fibre Bragg grating OH suppression and optimised
for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by
changing the grating and refocussing). This results in a significantly higher
transmission due to high efficiency coatings, a VPH grating at low incident
angle and low absorption glasses. The detector noise will also be lower.
Throughout the PRAXIS design special care was taken at every step along the
optical path to reduce thermal emission or stop it leaking into the system.
This made the spectrograph design challenging because practical constraints
required that the detector and the spectrograph enclosures be physically
separate by air at ambient temperature. At present, the instrument uses the
GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH
suppression unit based on multicore fibre Bragg gratings which will allow
increased field of view per fibre. Theoretical calculations show that the gain
in interline sky background signal-noise ratio over GNOSIS may very well be as
high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre
OH suppression unit.