sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Wycoff, Gary

Normalized to: Wycoff, G.

7 article(s) in total. 35 co-authors, from 1 to 6 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1006.5676  [pdf] - 1033394
Speckle Interferometry at the U.S. Naval Observatory. XV
Comments: 3 Tables
Submitted: 2010-06-29
Results of 2433 intensified CCD observations of double stars, made with the 26-inch refractor of the U.S. Naval Observatory are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1013 mean relative positions and range in separation from 0.96" to 58.05", with a mean separation of 13.50". This is the 15th in this series of papers and covers the period 2008 January 3 through 2008 December 21.
[2]  oai:arXiv.org:1006.4602  [pdf] - 1033279
Brorfelde Schmidt CCD Catalog (BSCC)
Comments: 16 pages, 22 figures, 2 tables, accepted by AJ
Submitted: 2010-06-23
The Brorfelde Schmidt CCD Catalog (BSCC) contains about 13.7 million stars, north of +49 deg Declination with precise positions and V, R photometry. The catalog has been constructed from the reductions of 18,667 CCD frames observed with the Brorfelde Schmidt Telescope between 2000 and 2007. The Tycho-2 catalog was used for astrometric and photometric reference stars. Errors of individual positions are about 20 to 200 mas for stars in the R = 10 to 18 mag range. External comparisons with 2MASS and SDSS reveal possible small systematic errors in the BSCC of up to about 30 mas. The catalog is supplemented with J, H, and K_s magnitudes from the 2MASS catalog. The catalog data file (about 550 MB ASCII, compressed) will be made available at the Strasbourg Data Center (CDS).
[3]  oai:arXiv.org:1003.2136  [pdf] - 1025634
The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)
Comments: accepted by AJ, 24 pages, 34 figures, 3 tables
Submitted: 2010-03-09
The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with proper motions, covering about R = 8 to 16 magnitudes. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates from the SPM program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major differences of UCAC3 data as compared to UCAC2 include a completely new raw data reduction with improved control over systematic errors in positions, significantly improved photometry, slightly deeper limiting magnitude, coverage of the north pole region, greater completeness by inclusion of double stars and weak detections. This of course leads to a catalog which is not as "clean" as UCAC2 and problem areas are outlined for the user in this paper. The positional accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on magnitude, while the errors in proper motions range from 1 to 10 mas/yr depending on magnitude and observing history, with a significant improvement over UCAC2 achieved due to the re-reduced SPM data and inclusion of more astrograph plate data unavailable at the time of UCAC2.
[4]  oai:arXiv.org:1002.0556  [pdf] - 1024949
UCAC3: Astrometric Reductions
Comments: 14 pages, 9 figures, accepted on 01/21/2010 for publication in the Astronomical Journal
Submitted: 2010-02-02
Presented here are the details of the astrometric reductions from the x,y data to mean Right Ascension (RA), Declination (Dec) coordinates of the third U.S. Naval Observatory (USNO) CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey (2MASS) data are extensively used to probe for coordinate and coma-like systematic errors in UCAC data mainly caused by the poor charge transfer efficiency (CTE) of the 4K CCD. Errors up to about 200 mas have been corrected using complex look-up tables handling multiple dependencies derived from the residuals. Similarly, field distortions and sub-pixel phase errors have also been evaluated using the residuals with respect to 2MASS. The overall magnitude equation is derived from UCAC calibration field observations alone, independent of external catalogs. Systematic errors of positions at UCAC observing epoch as presented in UCAC3 are better corrected than in the previous catalogs for most stars. The Tycho-2 catalog is used to obtain final positions on the International Celestial Reference Frame (ICRF). Residuals of the Tycho-2 reference stars show a small magnitude equation (depending on declination zone) that might be inherent in the Tycho-2 catalog.
[5]  oai:arXiv.org:0806.0256  [pdf] - 13141
The StarScan plate measuring machine: overview and calibrations
Comments: 24 pages, 8 figures, accepted for PASP
Submitted: 2008-06-02
The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring photographic astrograph plates to allow determination of proper motions for the USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates, about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan comprises of a CCD camera, telecentric lens, air-bearing granite table, stepper motor screws, and Heidenhain scales to operate in a step-stare mode. The repeatability of StarScan measures is about 0.2 micrometer. The CCD mapping as well as the global table coordinate system has been calibrated using a special dot calibration plate and the overall accuracy of StarScan x,y data is derived to be 0.5 micrometer. Application to real photographic plate data shows that position information of at least 0.65 micrometer accuracy can be extracted from course grain 103a-type emulsion astrometric plates. Transformations between "direct" and "reverse" measures of fine grain emulsion plate measures are obtained on the 0.3 micrometer level per well exposed stellar image and coordinate, which is at the limit of the StarScan machine.
[6]  oai:arXiv.org:astro-ph/0403060  [pdf] - 63251
The second US Naval Observatory CCD Astrograph Catalog (UCAC2)
Comments: accepted by AJ, AAS LaTeX, 14 figures, 10 tables
Submitted: 2004-03-02
The second USNO CCD Astrograph Catalog, UCAC2 was released in July 2003. Positions and proper motions for 48,330,571 sources (mostly stars) are available on 3 CDs, supplemented with 2MASS photometry for 99.5% of the sources. The catalog covers the sky area from -90 to +40 degrees declination, going up to +52 in some areas; this completely supersedes the UCAC1 released in 2001. Current epoch positions are obtained from observations with the USNO 8-inch Twin Astrograph equipped with a 4k CCD camera. The precision of the positions are 15 to 70 mas, depending on magnitude, with estimated systematic errors of 10 mas or below. Proper motions are derived by utilizing over 140 ground-and space-based catalogs, including Hipparcos/Tycho, the AC2000.2, as well as yet unpublished re-measures of the AGK2 plates and scans from the NPM and SPM plates. Proper motion errors are about 1 to 3 mas/yr for stars to 12th magnitude, and about 4 to 7 mas/yr for fainter stars to 16th magnitude. The observational data, astrometric reductions, results, and important information for the users of this catalog are presented.
[7]  oai:arXiv.org:astro-ph/9608034  [pdf] - 95152
The Twin Astrographic Catalog (TAC) Version 1.0
Comments: 22 pages LaTex, accepted by AJ, scheduled for Nov., no figures provided, needs aasms4.sty
Submitted: 1996-08-08
A first version of the Twin Astrographic Catalog (TAC) of positions for 705,679 stars within $-18^{\circ} \le \delta \le 90^{\circ}$ has been produced. The sky coverage of the TAC is complete to over 90\% in that area. The limiting magnitude is about B=11.5. Positions are based on $4912$ plates taken with the U.S. Naval Observatory Twin Astrograph (blue, yellow lens) at epochs 1977--1986. The TAC is supplemented by proper motions which are obtained from a combination with a re--reduced Astrographic Catalog (AC). Some AC zones are available now and a complete northern hemisphere is expected by fall 1996. Proper motions of almost all TAC stars will be generated as the AC work progresses. The average precision of a catalog position is 90 mas per coordinate at epoch of observation. A large fraction of that error is introduced by the currently available reference stars. The inherent precision of the TAC data is considerably better. The precision of the proper motions is currently 2.5 to 4 mas/yr. Magnitude--dependent systematic errors have been found and preliminarily corrected. The final reduction of this plate material will be performed with the Hipparcos catalog in 1997. The TAC is about 3 times more precise than the PPM or ACRS in the northern hemisphere at current epochs and contains about 3 times more stars. The TAC has a higher star density than the Tycho catalog and provides independent, high precision positions for a large fraction of the Tycho stars at an epoch about 10 years earlier than the Tycho mean epoch. The TAC version 1.0 data are released as the AC zones become available. For latest information, look at the US Naval Observatory World Wide Web page http://aries.usno.navy.mil/ad/tac.html.