Normalized to: Wycoff, G.
[1]
oai:arXiv.org:1006.5676 [pdf] - 1033394
Speckle Interferometry at the U.S. Naval Observatory. XV
Submitted: 2010-06-29
Results of 2433 intensified CCD observations of double stars, made with the
26-inch refractor of the U.S. Naval Observatory are presented. Each observation
of a system represents a combination of over 2000 short-exposure images. These
observations are averaged into 1013 mean relative positions and range in
separation from 0.96" to 58.05", with a mean separation of 13.50". This is the
15th in this series of papers and covers the period 2008 January 3 through 2008
December 21.
[2]
oai:arXiv.org:1006.4602 [pdf] - 1033279
Brorfelde Schmidt CCD Catalog (BSCC)
Submitted: 2010-06-23
The Brorfelde Schmidt CCD Catalog (BSCC) contains about 13.7 million stars,
north of +49 deg Declination with precise positions and V, R photometry. The
catalog has been constructed from the reductions of 18,667 CCD frames observed
with the Brorfelde Schmidt Telescope between 2000 and 2007. The Tycho-2 catalog
was used for astrometric and photometric reference stars. Errors of individual
positions are about 20 to 200 mas for stars in the R = 10 to 18 mag range.
External comparisons with 2MASS and SDSS reveal possible small systematic
errors in the BSCC of up to about 30 mas. The catalog is supplemented with J,
H, and K_s magnitudes from the 2MASS catalog. The catalog data file (about 550
MB ASCII, compressed) will be made available at the Strasbourg Data Center
(CDS).
[3]
oai:arXiv.org:1003.2136 [pdf] - 1025634
The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)
Zacharias, N.;
Finch, C.;
Girard, T.;
Hambly, N.;
Wycoff, G.;
Zacharias, M.;
Castillo, D.;
Corbin, T.;
DiVittorio, M.;
Dutta, S.;
Gaume, R.;
Gauss, S.;
Germain, M.;
Hall, D.;
Hartkopf, W.;
Hsu, D.;
Holdenried, E.;
Makarov, V.;
Martines, M.;
Mason, B.;
Monet, D.;
Rafferty, T.;
Rhodes, A.;
Siemers, T.;
Smith, D.;
Tilleman, T.;
Urban, S.;
Wieder, G.;
Winter, L.;
Young, A.
Submitted: 2010-03-09
The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was
released at the IAU General Assembly on 2009 August 10. It is the first all-sky
release in this series and contains just over 100 million objects, about 95
million of them with proper motions, covering about R = 8 to 16 magnitudes.
Current epoch positions are obtained from the observations with the 20 cm
aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper
motions are derived by combining these observations with over 140 ground- and
space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as
unpublished measures of over 5000 plates from other astrographs. For most of
the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates
from the SPM program (YSJ1) form the basis for proper motions. These data are
supplemented by all-sky Schmidt plate survey astrometry and photometry obtained
from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major
differences of UCAC3 data as compared to UCAC2 include a completely new raw
data reduction with improved control over systematic errors in positions,
significantly improved photometry, slightly deeper limiting magnitude, coverage
of the north pole region, greater completeness by inclusion of double stars and
weak detections. This of course leads to a catalog which is not as "clean" as
UCAC2 and problem areas are outlined for the user in this paper. The positional
accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on
magnitude, while the errors in proper motions range from 1 to 10 mas/yr
depending on magnitude and observing history, with a significant improvement
over UCAC2 achieved due to the re-reduced SPM data and inclusion of more
astrograph plate data unavailable at the time of UCAC2.
[4]
oai:arXiv.org:1002.0556 [pdf] - 1024949
UCAC3: Astrometric Reductions
Submitted: 2010-02-02
Presented here are the details of the astrometric reductions from the x,y
data to mean Right Ascension (RA), Declination (Dec) coordinates of the third
U.S. Naval Observatory (USNO) CCD Astrograph Catalog (UCAC3). For these new
reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey
(2MASS) data are extensively used to probe for coordinate and coma-like
systematic errors in UCAC data mainly caused by the poor charge transfer
efficiency (CTE) of the 4K CCD. Errors up to about 200 mas have been corrected
using complex look-up tables handling multiple dependencies derived from the
residuals. Similarly, field distortions and sub-pixel phase errors have also
been evaluated using the residuals with respect to 2MASS. The overall magnitude
equation is derived from UCAC calibration field observations alone, independent
of external catalogs. Systematic errors of positions at UCAC observing epoch as
presented in UCAC3 are better corrected than in the previous catalogs for most
stars. The Tycho-2 catalog is used to obtain final positions on the
International Celestial Reference Frame (ICRF). Residuals of the Tycho-2
reference stars show a small magnitude equation (depending on declination zone)
that might be inherent in the Tycho-2 catalog.
[5]
oai:arXiv.org:0806.0256 [pdf] - 13141
The StarScan plate measuring machine: overview and calibrations
Submitted: 2008-06-02
The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring
photographic astrograph plates to allow determination of proper motions for the
USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates,
about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin
Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan
comprises of a CCD camera, telecentric lens, air-bearing granite table, stepper
motor screws, and Heidenhain scales to operate in a step-stare mode. The
repeatability of StarScan measures is about 0.2 micrometer. The CCD mapping as
well as the global table coordinate system has been calibrated using a special
dot calibration plate and the overall accuracy of StarScan x,y data is derived
to be 0.5 micrometer. Application to real photographic plate data shows that
position information of at least 0.65 micrometer accuracy can be extracted from
course grain 103a-type emulsion astrometric plates. Transformations between
"direct" and "reverse" measures of fine grain emulsion plate measures are
obtained on the 0.3 micrometer level per well exposed stellar image and
coordinate, which is at the limit of the StarScan machine.
[6]
oai:arXiv.org:astro-ph/0403060 [pdf] - 63251
The second US Naval Observatory CCD Astrograph Catalog (UCAC2)
Submitted: 2004-03-02
The second USNO CCD Astrograph Catalog, UCAC2 was released in July 2003.
Positions and proper motions for 48,330,571 sources (mostly stars) are
available on 3 CDs, supplemented with 2MASS photometry for 99.5% of the
sources. The catalog covers the sky area from -90 to +40 degrees declination,
going up to +52 in some areas; this completely supersedes the UCAC1 released in
2001. Current epoch positions are obtained from observations with the USNO
8-inch Twin Astrograph equipped with a 4k CCD camera. The precision of the
positions are 15 to 70 mas, depending on magnitude, with estimated systematic
errors of 10 mas or below. Proper motions are derived by utilizing over 140
ground-and space-based catalogs, including Hipparcos/Tycho, the AC2000.2, as
well as yet unpublished re-measures of the AGK2 plates and scans from the NPM
and SPM plates. Proper motion errors are about 1 to 3 mas/yr for stars to 12th
magnitude, and about 4 to 7 mas/yr for fainter stars to 16th magnitude. The
observational data, astrometric reductions, results, and important information
for the users of this catalog are presented.
[7]
oai:arXiv.org:astro-ph/9608034 [pdf] - 95152
The Twin Astrographic Catalog (TAC) Version 1.0
Submitted: 1996-08-08
A first version of the Twin Astrographic Catalog (TAC) of positions for
705,679 stars within $-18^{\circ} \le \delta \le 90^{\circ}$ has been produced.
The sky coverage of the TAC is complete to over 90\% in that area. The limiting
magnitude is about B=11.5. Positions are based on $4912$ plates taken with the
U.S. Naval Observatory Twin Astrograph (blue, yellow lens) at epochs
1977--1986. The TAC is supplemented by proper motions which are obtained from a
combination with a re--reduced Astrographic Catalog (AC). Some AC zones are
available now and a complete northern hemisphere is expected by fall 1996.
Proper motions of almost all TAC stars will be generated as the AC work
progresses. The average precision of a catalog position is 90 mas per
coordinate at epoch of observation. A large fraction of that error is
introduced by the currently available reference stars. The inherent precision
of the TAC data is considerably better. The precision of the proper motions is
currently 2.5 to 4 mas/yr. Magnitude--dependent systematic errors have been
found and preliminarily corrected. The final reduction of this plate material
will be performed with the Hipparcos catalog in 1997. The TAC is about 3 times
more precise than the PPM or ACRS in the northern hemisphere at current epochs
and contains about 3 times more stars. The TAC has a higher star density than
the Tycho catalog and provides independent, high precision positions for a
large fraction of the Tycho stars at an epoch about 10 years earlier than the
Tycho mean epoch. The TAC version 1.0 data are released as the AC zones become
available. For latest information, look at the US Naval Observatory World Wide
Web page http://aries.usno.navy.mil/ad/tac.html.