Normalized to: Wulterkens, G.
[1]
oai:arXiv.org:1110.1944 [pdf] - 1084747
X-shooter, the new wide band intermediate resolution spectrograph at the
ESO Very Large Telescope
Vernet, Joel;
Dekker, H.;
D'Odorico, S.;
Kaper, L.;
Kjaergaard, P.;
Hammer, F.;
Randich, S.;
Zerbi, F.;
Groot, P. M.;
Hjorth, J.;
Guinouard, I.;
Navarro, R.;
Adolfse, T.;
Albers, P. W.;
Amans, J. -P.;
Andersen, J. J.;
Andersen, M. I.;
Binetruy, P.;
Bristow, P.;
Castillo, R.;
Chemla, F.;
Christensen, L.;
Conconi, P.;
Conzelmann, R.;
Dam, J.;
De Caprio, V.;
Postigo, A. De Ugarte;
Delabre, B.;
Di Marcantonio, P.;
Downing, M.;
Elswijk, E.;
Finger, G.;
Fischer, G.;
Flores, H.;
Francois, P.;
Goldoni, P.;
Guglielmi, L.;
Haigron, R.;
Hanenburg, H.;
Hendriks, I.;
Horrobin, M.;
Horville, D.;
Jessen, N. C.;
Kerber, F.;
Kern, L.;
Kiekebusch, M.;
Kleszcz, P.;
Klougart, J.;
Kragt, J.;
Larsen, H. H.;
Lizon, J. -L.;
Lucuix, C.;
Mainieri, V.;
Manuputy, R.;
Martayan, C.;
Mason, E.;
Mazzoleni, R.;
Michaelsen, N.;
Modigliani, A.;
Moehler, S.;
Møller, P.;
Sørensen, A. Norup;
Nørregaard, P.;
Peroux, C.;
Patat, F.;
Pena, E.;
Pragt, J.;
Reinero, C.;
Riga, F.;
Riva, M.;
Roelfsema, R.;
Royer, F.;
Sacco, G.;
Santin, P.;
Schoenmaker, T.;
Spano, P.;
Sweers, E.;
Ter Horst, R.;
Tintori, M.;
Tromp, N.;
van Dael, P.;
van der Vliet, H.;
Venema, L.;
Vidali, M.;
Vinther, J.;
Vola, P.;
Winters, R.;
Wistisen, D.;
Wulterkens, G.;
Zacchei, A.
Submitted: 2011-10-10
X-shooter is the first 2nd generation instrument of the ESO Very Large
Telescope(VLT). It is a very efficient, single-target, intermediate-resolution
spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The
instrument covers, in a single exposure, the spectral range from 300 to 2500
nm. It is designed to maximize the sensitivity in this spectral range through
dichroic splitting in three arms with optimized optics, coatings, dispersive
elements and detectors. It operates at intermediate spectral resolution
(R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle
spectral format (prism cross-dispersers) in the three arms. It includes a
1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A
dedicated data reduction package delivers fully calibrated two-dimensional and
extracted spectra over the full wavelength range. We describe the main
characteristics of the instrument and present its performance as measured
during commissioning, science verification and the first months of science
operations.
[2]
oai:arXiv.org:1009.1816 [pdf] - 1034839
Development of five multifibre links for the OPTIMOS-EVE study for the
E-ELT
Submitted: 2010-09-09
The OPTIMOS-EVE concept provides optical to near-infrared (370-1700 nm)
spectroscopy, with three spectral resolution (5000, 15000 and 30000), with high
simultaneous multiplex (at least 200). The optical fibre links are distributed
in five kinds of bundles: several hundreds of mono-object systems with three
types of bundles, fibre size being used to adapt slit with, and thus spectral
resolution, 30 deployable medium IFUs (about 2"x3") and one large IFU (about
6"x12"). This paper gives an overview of the design of each mode and describes
the specific developments required to optimise the performances of the fibre
system.