Normalized to: Wooff, R.
[1]
oai:arXiv.org:1409.7448 [pdf] - 1222257
GRACES: Gemini remote access to CFHT ESPaDOnS Spectrograph through the
longest astronomical fiber ever made (Experimental phase completed.)
Chené, André-Nicolas;
Pazder, John;
Barrick, Gregory;
Anthony, Andre;
Benedict, Tom;
Duncan, David;
Gigoux, Pedro;
Kleinman, Scot;
Malo, Lison;
Martioli, Eder;
Moutou, Claire;
Placco, Vinicius;
Reshetovand, Vlad;
Rhee, Jaehyon;
Roth, Katherine;
Schiavon, Ricardo P.;
Tollestrup, Eric;
Vermeulen, Tom;
White, John;
Wooff, Robert
Submitted: 2014-09-25
The Gemini Remote Access to CFHT ESPaDONS Spectrograph has achieved first
light of its experimental phase in May 2014. It successfully collected light
from the Gemini North telescope and sent it through two 270 m optical fibers to
the the ESPaDOnS spectrograph at CFHT to deliver high-resolution spectroscopy
across the optical region. The fibers gave an average focal ratio degradation
of 14% on sky, and a maximum transmittance of 85% at 800nm. GRACES achieved
delivering spectra with a resolution power of R = 40,000 and R = 66,000 between
400 and 1,000 nm. It has a ~8% throughput and is sensitive to target fainter
than 21st mag in 1 hour. The average acquisition time of a target is around 10
min. This project is a great example of a productive collaboration between two
observatories on Maunakea that was successful due to the reciprocal involvement
of the Gemini, CFHT, and NRC Herzberg teams, and all the staff involved closely
or indirectly.
[2]
oai:arXiv.org:1408.4406 [pdf] - 1216393
NFIRAOS First Facility AO System for the Thirty Meter Telescope
Herriot, Glen;
Andersen, David;
Atwood, Jenny;
Boyer, Corinne;
Byrnes, Peter;
Caputa, Kris;
Ellerbroek, Brent;
Gilles, Luc;
Hill, Alexis;
Ljusic, Zoran;
Pazder, John;
Rosensteiner, Matthias;
Smith, Malcolm;
Spano, Paolo;
Szeto, Kei;
Véran, Jean-Pierre;
Wevers, Ivan;
Wang, Lianqi;
Wooff, Robert
Submitted: 2014-08-19
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an
order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although
most observing will use 6 laser guide stars, it also has an NGS-only mode.
Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS
delivers a 2-arcminute beam to three client instruments, and relies on up to
three IR WFSs in each instrument. We present recent work including: robust
automated acquisition on these IR WFSs; trade-off studies for a common-size of
deformable mirror; real-time computing architectures; simplified designs for
high-order NGS-mode wavefront sensing; modest upgrade concepts for
high-contrast imaging.
[3]
oai:arXiv.org:1407.2995 [pdf] - 1215601
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
Moore, Anna M.;
Larkin, James E.;
Wright, Shelley A.;
Bauman, Brian;
Dunn, Jennifer;
Ellerbroek, Brent;
Phillips, Andrew C.;
Simard, Luc;
Suzuki, Ryuji;
Zhang, Kai;
Aliado, Ted;
Brims, George;
Canfield, John;
Chen, Shaojie;
Dekany, Richard;
Delacroix, Alex;
Do, Tuan;
Herriot, Glen;
Ikenoue, Bungo;
Johnson, Chris;
Meyer, Elliot;
Obuchi, Yoshiyuki;
Pazder, John;
Reshetov, Vladimir;
Riddle, Reed;
Saito, Sakae;
Smith, Roger;
Sohn, Ji Man;
Uraguchi, Fumihiro;
Usuda, Tomonori;
Wang, Eric;
Wang, Lianqi;
Weiss, Jason;
Wooff, Robert
Submitted: 2014-07-10
We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron)
integral field spectrograph and imaging camera for the Thirty Meter Telescope
(TMT). With extremely low wavefront error (<30 nm) and on-board wavefront
sensors, IRIS will take advantage of the high angular resolution of the narrow
field infrared adaptive optics system (NFIRAOS) to dissect the sky at the
diffraction limit of the 30-meter aperture. With a primary spectral resolution
of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will
create an unparalleled ability to explore high redshift galaxies, the Galactic
center, star forming regions and virtually any astrophysical object. This paper
summarizes the entire design and basic capabilities. Among the design
innovations is the combination of lenslet and slicer integral field units, new
4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared
wavefront sensors, and a very large vacuum cryogenic system.
[4]
oai:arXiv.org:1407.2312 [pdf] - 1215531
Gemini Planet Imager One Button Approach
Dunn, Jennifer;
Kerley, Dan;
Saddlemyer, Leslie;
Smith, Malcolm;
Wooff, Robert;
Savransky, Dmitry;
Palmer, Dave;
Macintosh, Bruce;
Weiss, Jason;
Quiroz, Carlos;
Rantakyrö, Fredrik T.;
Goodsell, Stephen J.
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is an "extreme" adaptive optics coronagraph
system that is now on the Gemini South telescope in Chile. This instrument is
composed of three different systems that historically have been separate
instruments. These systems are the extreme Adaptive Optics system, with
deformable mirrors, including a high-order 64x64 element MEMS system; the
Science Instrument, which is a near-infrared integral field spectrograph; and
the Calibration system, a precision IR wavefront sensor that also holds key
coronagraph components. Each system coordinates actions that require precise
timing. The observatory is responsible for starting these actions and has
typically done this asynchronously across independent systems. Despite this
complexity we strived to provide an interface that is as close to a one-button
approach as possible. This paper will describe the sequencing of these systems
both internally and externally through the observatory.
[5]
oai:arXiv.org:1007.2000 [pdf] - 1033641
The infrared imaging spectrograph (IRIS) for TMT: on-instrument
wavefront sensors and NFIRAOS interface
Loop, David;
Reshetov, Vlad;
Fletcher, Murray;
Wooff, Robert;
Dunn, Jennifer;
Moore, Anna;
Smith, Roger;
Hale, David;
Dekany, Richard;
Wang, Lianqi;
Ellerbroek, Brent;
Simard, Luc;
Crampton, David
Submitted: 2010-07-12
The InfraRed Imaging Spectrograph (IRIS) is a first light client science
instrument for the TMT observatory that operates as a client of the NFIRAOS
facility multi-conjugate adaptive optics system. This paper reports on the
concept study and baseline concept design of the On-Instrument WaveFront
Sensors (OIWFS) and NFIRAOS interface subsystems of the IRIS science
instrument, a collaborative effort by NRC-HIA, Caltech, and TMT AO and
Instrument teams. This includes work on system engineering, structural and
thermal design, sky coverage modeling, patrol geometry, probe optics and
mechanics design, camera design, and controls design.
[6]
oai:arXiv.org:astro-ph/0604577 [pdf] - 81646
FLAMINGOS-2: The Facility Near-Infrared Wide-field Imager & Multi-Object
Spectrograph for Gemini
Eikenberry, Stephen;
Elston, Richard;
Raines, S. Nicholas;
Julian, Jeff;
Hanna, Kevin;
Hon, David;
Julian, Roger;
Bandyopadhyay, R.;
Bennett, J. Greg;
Bessoff, Aaron;
Branch, Matt;
Corley, Richard;
Eriksen, John-David;
Frommeyer, Skip;
Gonzalez, Anthony;
Herlevich, Michael;
Marin-Franch, Antonio;
Marti, Jose;
Murphey, Charlie;
Rashkin, David;
Warner, Craig;
Leckie, Brian;
Gardhouse, W. Rusty;
Fletcher, Murray;
Dunn, Jennifer;
Wooff, Robert;
Hardy, Tim
Submitted: 2006-04-27
We report on the design and status of the FLAMINGOS-2 instrument - a
fully-cryogenic facility near-infrared imager and multi-object spectrograph for
the Gemini 8-meter telescopes. FLAMINGOS-2 has a refractive all-spherical
optical system providing 0.18-arcsecond pixels and a 6.2-arcminute circular
field-of-view on a 2048x2048-pixel HAWAII-2 0.9-2.4 mm detector array. A
slit/decker wheel mechanism allows the selection of up to 9 multi-object
laser-machined plates or 3 long slits for spectroscopy over a 6x2-arcminute
field of view, and selectable grisms provide resolutions from $\sim$ 1300 to
$\sim $3000 over the entire spectrograph bandpass. FLAMINGOS-2 is also
compatible with the Gemini Multi-Conjugate Adaptive Optics system, providing
multi-object spectroscopic capabilities over a 3x1-arcminute field with high
spatial resolution (0.09-arcsec/pixel). We review the designs of optical,
mechanical, electronics, software, and On-Instrument WaveFront Sensor
subsystems. We also present the current status of the project, currently in
final testing in mid-2006.
[7]
oai:arXiv.org:astro-ph/9609118 [pdf] - 95438
Wide-field CCD imaging at CFHT: the MOCAM example
Submitted: 1996-09-18
We describe a new 4096x4096 pixel CCD mosaic camera (MOCAM) available at the
prime focus of the Canada-France-Hawaii Telescope (CFHT). The camera is a
mosaic of four 2048x2048$ Loral frontside-illuminated CCDs with 15 $\mu$m
pixels, providing a field of view of 14'x14' at a scale of 0.21''/pixel. MOCAM
is equipped with B, V, R and I filters and has demonstrated image quality of
0.5''-0.6'' FWHM over the entire field. MOCAM will also be used with the CFHT
adaptive optic bonnette and will provide a field of view of 90'' at a scale of
0.02 ''/pixel. MOCAM works within the CFHT Pegasus software environment and
observers familiar with this system require no additional training to use this
camera effectively. The technical details, the performance and the first images
obtained on the telescope with MOCAM are presented. In particular, we discuss
some important improvements with respect to the standard single-CCD FOCAM
camera, such as multi-output parallel readout and dynamic anti-blooming. We
also discuss critical technical issues concerning future wide-field imaging
facilities at the CFHT prime focus in light of our experience with MOCAM and
our recent experience with the even larger UH 8192x8192 pixel CCD mosaic
camera.