sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Wooff, Robert

Normalized to: Wooff, R.

7 article(s) in total. 107 co-authors, from 1 to 4 common article(s). Median position in authors list is 19,0.

[1]  oai:arXiv.org:1409.7448  [pdf] - 1222257
GRACES: Gemini remote access to CFHT ESPaDOnS Spectrograph through the longest astronomical fiber ever made (Experimental phase completed.)
Comments: Presented at SPIE Astronomical Telescopes + Instrumentation 2014
Submitted: 2014-09-25
The Gemini Remote Access to CFHT ESPaDONS Spectrograph has achieved first light of its experimental phase in May 2014. It successfully collected light from the Gemini North telescope and sent it through two 270 m optical fibers to the the ESPaDOnS spectrograph at CFHT to deliver high-resolution spectroscopy across the optical region. The fibers gave an average focal ratio degradation of 14% on sky, and a maximum transmittance of 85% at 800nm. GRACES achieved delivering spectra with a resolution power of R = 40,000 and R = 66,000 between 400 and 1,000 nm. It has a ~8% throughput and is sensitive to target fainter than 21st mag in 1 hour. The average acquisition time of a target is around 10 min. This project is a great example of a productive collaboration between two observatories on Maunakea that was successful due to the reciprocal involvement of the Gemini, CFHT, and NRC Herzberg teams, and all the staff involved closely or indirectly.
[2]  oai:arXiv.org:1408.4406  [pdf] - 1216393
NFIRAOS First Facility AO System for the Thirty Meter Telescope
Comments: ..submitted to SPIE 9148 Astronomical Telescopes and Instrumentation - Adaptive Optics Systems IV (2014)
Submitted: 2014-08-19
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although most observing will use 6 laser guide stars, it also has an NGS-only mode. Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS delivers a 2-arcminute beam to three client instruments, and relies on up to three IR WFSs in each instrument. We present recent work including: robust automated acquisition on these IR WFSs; trade-off studies for a common-size of deformable mirror; real-time computing architectures; simplified designs for high-order NGS-mode wavefront sensing; modest upgrade concepts for high-contrast imaging.
[3]  oai:arXiv.org:1407.2995  [pdf] - 1215601
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
Comments: Proceedings of the SPIE, 9147-76 (2014)
Submitted: 2014-07-10
We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron) integral field spectrograph and imaging camera for the Thirty Meter Telescope (TMT). With extremely low wavefront error (<30 nm) and on-board wavefront sensors, IRIS will take advantage of the high angular resolution of the narrow field infrared adaptive optics system (NFIRAOS) to dissect the sky at the diffraction limit of the 30-meter aperture. With a primary spectral resolution of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will create an unparalleled ability to explore high redshift galaxies, the Galactic center, star forming regions and virtually any astrophysical object. This paper summarizes the entire design and basic capabilities. Among the design innovations is the combination of lenslet and slicer integral field units, new 4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared wavefront sensors, and a very large vacuum cryogenic system.
[4]  oai:arXiv.org:1407.2312  [pdf] - 1215531
Gemini Planet Imager One Button Approach
Comments: 9 pages, 2 figures. Proceedings of the SPIE, 9147-190
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is an "extreme" adaptive optics coronagraph system that is now on the Gemini South telescope in Chile. This instrument is composed of three different systems that historically have been separate instruments. These systems are the extreme Adaptive Optics system, with deformable mirrors, including a high-order 64x64 element MEMS system; the Science Instrument, which is a near-infrared integral field spectrograph; and the Calibration system, a precision IR wavefront sensor that also holds key coronagraph components. Each system coordinates actions that require precise timing. The observatory is responsible for starting these actions and has typically done this asynchronously across independent systems. Despite this complexity we strived to provide an interface that is as close to a one-button approach as possible. This paper will describe the sequencing of these systems both internally and externally through the observatory.
[5]  oai:arXiv.org:1007.2000  [pdf] - 1033641
The infrared imaging spectrograph (IRIS) for TMT: on-instrument wavefront sensors and NFIRAOS interface
Comments: 17 pages, 12 figures, SPIE7735-285
Submitted: 2010-07-12
The InfraRed Imaging Spectrograph (IRIS) is a first light client science instrument for the TMT observatory that operates as a client of the NFIRAOS facility multi-conjugate adaptive optics system. This paper reports on the concept study and baseline concept design of the On-Instrument WaveFront Sensors (OIWFS) and NFIRAOS interface subsystems of the IRIS science instrument, a collaborative effort by NRC-HIA, Caltech, and TMT AO and Instrument teams. This includes work on system engineering, structural and thermal design, sky coverage modeling, patrol geometry, probe optics and mechanics design, camera design, and controls design.
[6]  oai:arXiv.org:astro-ph/0604577  [pdf] - 81646
FLAMINGOS-2: The Facility Near-Infrared Wide-field Imager & Multi-Object Spectrograph for Gemini
Comments: Submitted to SPIE Astronomical Telescopes & Instrumentation; 12 pages, incl. color figures
Submitted: 2006-04-27
We report on the design and status of the FLAMINGOS-2 instrument - a fully-cryogenic facility near-infrared imager and multi-object spectrograph for the Gemini 8-meter telescopes. FLAMINGOS-2 has a refractive all-spherical optical system providing 0.18-arcsecond pixels and a 6.2-arcminute circular field-of-view on a 2048x2048-pixel HAWAII-2 0.9-2.4 mm detector array. A slit/decker wheel mechanism allows the selection of up to 9 multi-object laser-machined plates or 3 long slits for spectroscopy over a 6x2-arcminute field of view, and selectable grisms provide resolutions from $\sim$ 1300 to $\sim $3000 over the entire spectrograph bandpass. FLAMINGOS-2 is also compatible with the Gemini Multi-Conjugate Adaptive Optics system, providing multi-object spectroscopic capabilities over a 3x1-arcminute field with high spatial resolution (0.09-arcsec/pixel). We review the designs of optical, mechanical, electronics, software, and On-Instrument WaveFront Sensor subsystems. We also present the current status of the project, currently in final testing in mid-2006.
[7]  oai:arXiv.org:astro-ph/9609118  [pdf] - 95438
Wide-field CCD imaging at CFHT: the MOCAM example
Comments: Accepted for publication in Publication of the Astronomical Society of the Pacific. Latex with aas2pp4.sty and epsf.sty. 12 pages, 10 figures
Submitted: 1996-09-18
We describe a new 4096x4096 pixel CCD mosaic camera (MOCAM) available at the prime focus of the Canada-France-Hawaii Telescope (CFHT). The camera is a mosaic of four 2048x2048$ Loral frontside-illuminated CCDs with 15 $\mu$m pixels, providing a field of view of 14'x14' at a scale of 0.21''/pixel. MOCAM is equipped with B, V, R and I filters and has demonstrated image quality of 0.5''-0.6'' FWHM over the entire field. MOCAM will also be used with the CFHT adaptive optic bonnette and will provide a field of view of 90'' at a scale of 0.02 ''/pixel. MOCAM works within the CFHT Pegasus software environment and observers familiar with this system require no additional training to use this camera effectively. The technical details, the performance and the first images obtained on the telescope with MOCAM are presented. In particular, we discuss some important improvements with respect to the standard single-CCD FOCAM camera, such as multi-output parallel readout and dynamic anti-blooming. We also discuss critical technical issues concerning future wide-field imaging facilities at the CFHT prime focus in light of our experience with MOCAM and our recent experience with the even larger UH 8192x8192 pixel CCD mosaic camera.