Normalized to: Wooff, B.
[1]
oai:arXiv.org:1407.2999 [pdf] - 1215605
On-instrument wavefront sensor design for the TMT infrared imaging
spectrograph (IRIS) update
Submitted: 2014-07-10
The first light instrument on the Thirty Meter Telescope (TMT) project will
be the InfraRed Imaging Spectrograph (IRIS). IRIS will be mounted on a bottom
port of the facility AO instrument NFIRAOS. IRIS will report guiding
information to the NFIRAOS through the On-Instrument Wavefront Sensor (OIWFS)
that is part of IRIS. This will be in a self-contained compartment of IRIS and
will provide three deployable wavefront sensor probe arms. This entire unit
will be rotated to provide field de-rotation. Currently in our preliminary
design stage our efforts have included: prototyping of the probe arm to
determine the accuracy of this critical component, handling cart design and
reviewing different types of glass for the atmospheric dispersion.
[2]
oai:arXiv.org:0907.3610 [pdf] - 1003008
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk
Maxwell Telescope
Buckle, J. V.;
Hills, R. E.;
Smith, H.;
Dent, W. R. F.;
Bell, G.;
Curtis, E. I.;
Dace, R.;
Gibson, H.;
Graves, S. F.;
Leech, J.;
Richer, J. S.;
Williamson, R.;
Withington, S.;
Yassin, G.;
Bennett, R.;
Hastings, P.;
Laidlaw, I.;
Lightfoot, J. F.;
Burgess, T.;
Dewdney, P. E.;
Hovey, G.;
Willis, A. G.;
Redman, R.;
Wooff, B.;
Berry, D. S.;
Cavanagh, B.;
Davis, G. R.;
Dempsey, J.;
Friberg, P.;
Jenness, T.;
Kackley, R.;
Rees, N. P.;
Tilanus, R.;
Walther, C.;
Zwart, W.;
Klapwijk, T. M.;
Kroug, M.;
Zijlstra, T.
Submitted: 2009-07-21
This paper describes a new Heterodyne Array Receiver Programme (HARP) and
Auto-Correlation Spectral Imaging System (ACSIS) that have recently been
installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The
16-element focal-plane array receiver, operating in the submillimetre from 325
to 375 GHz, offers high (three-dimensional) mapping speeds, along with
significant improvements over single-detector counterparts in calibration and
image quality. Receiver temperatures are $\sim$120 K across the whole band and
system temperatures of $\sim$300K are reached routinely under good weather
conditions. The system includes a single-sideband filter so these are SSB
figures. Used in conjunction with ACSIS, the system can produce large-scale
maps rapidly, in one or more frequency settings, at high spatial and spectral
resolution. Fully-sampled maps of size 1 square degree can be observed in under
1 hour.
The scientific need for array receivers arises from the requirement for
programmes to study samples of objects of statistically significant size, in
large-scale unbiased surveys of galactic and extra-galactic regions. Along with
morphological information, the new spectral imaging system can be used to study
the physical and chemical properties of regions of interest. Its
three-dimensional imaging capabilities are critical for research into
turbulence and dynamics. In addition, HARP/ACSIS will provide highly
complementary science programmes to wide-field continuum studies, and produce
the essential preparatory work for submillimetre interferometers such as the
SMA and ALMA.