Normalized to: Woodward, J.
[1]
oai:arXiv.org:1806.02422 [pdf] - 1695831
Testing of the LSST's photometric calibration strategy at the CTIO 0.9
meter telescope
Submitted: 2018-06-06
The calibration hardware system of the Large Synoptic Survey Telescope (LSST)
is designed to measure two quantities: a telescope's instrumental response and
atmospheric transmission, both as a function of wavelength. First of all, a
"collimated beam projector" is designed to measure the instrumental response
function by projecting monochromatic light through a mask and a collimating
optic onto the telescope. During the measurement, the light level is monitored
with a NIST-traceable photodiode. This method does not suffer from stray light
effects or the reflections (known as ghosting) present when using a flat-field
screen illumination, which has a systematic source of uncertainty from
uncontrolled reflections. It allows for an independent measurement of the
throughput of the telescope's optical train as well as each filter's
transmission as a function of position on the primary mirror. Second, CALSPEC
stars can be used as calibrated light sources to illuminate the atmosphere and
measure its transmission. To measure the atmosphere's transfer function, we use
the telescope's imager with a Ronchi grating in place of a filter to configure
it as a low resolution slitless spectrograph. In this paper, we describe this
calibration strategy, focusing on results from a prototype system at the Cerro
Tololo Inter-American Observatory (CTIO) 0.9 meter telescope. We compare the
instrumental throughput measurements to nominal values measured using a
laboratory spectrophotometer, and we describe measurements of the atmosphere
made via CALSPEC standard stars during the same run.
[2]
oai:arXiv.org:1003.3465 [pdf] - 1025778
Precise Throughput Determination of the PanSTARRS Telescope and the
Gigapixel Imager using a Calibrated Silicon Photodiode and a Tunable Laser:
Initial Results
Submitted: 2010-03-17
We have used a precision calibrated photodiode as the fundamental metrology
reference in order to determine the relative throughput of the PanSTARRS
telescope and the Gigapixel imager, from 400 nm to 1050 nm. Our technique uses
a tunable laser as a source of illumination on a transmissive flat-field
screen. We determine the full-aperture system throughput as a function of
wavelength, including (in a single integral measurement) the mirror
reflectivity, the transmission functions of the filters and the corrector
optics, and the detector quantum efficiency, by comparing the light seen by
each pixel in the CCD array to that measured by a precision-calibrated silicon
photodiode. This method allows us to determine the relative throughput of the
entire system as a function of wavelength, for each pixel in the instrument,
without observations of celestial standards. We present promising initial
results from this characterization of the PanSTARRS system, and we use
synthetic photometry to assess the photometric perturbations due to throughput
variation across the field of view.