sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Withington, S.

Normalized to: Withington, S.

31 article(s) in total. 378 co-authors, from 1 to 17 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:2001.09089  [pdf] - 2071768
Suppressed-gap millimetre wave kinetic inductance detectors using DC-bias current
Comments:
Submitted: 2020-01-24, last modified: 2020-03-28
In this study, we evaluate the suitability of using DC-biased aluminium resonators as low-frequency kinetic inductance detectors operating in the frequency range of 50 - 120 GHz. Our analysis routine for supercurrent-biased resonators is based on the Usadel equations and gives outputs including density of states, complex conductivities, transmission line properties, and quasiparticle lifetimes. Results from our analysis confirm previous experimental observations on resonant frequency tuneability and retention of high quality factor. Crucially, our analysis suggests that DC-biased resonators demonstrate significantly suppressed superconducting density of states gap. Consequently these resonators have lower frequency detection threshold and are suitable materials for low-frequency kinetic inductance detectors.
[2]  oai:arXiv.org:2001.08947  [pdf] - 2036920
First Characterization of a Superconducting Filter-bank Spectrometer for Hyper-spectral Microwave Atmospheric Sounding with Transition Edge Sensors
Comments: 13 pages, 12 figures
Submitted: 2020-01-24
We describe the design, fabrication, integration and characterization of a prototype superconducting filter bank with transition edge sensor readout designed to explore millimetre-wave detection at frequencies in the range 40 to 65 GHz. Results indicate highly uniform filter channel placement in frequency and high overall detection efficiency. The route to a full atmospheric sounding instrument in this frequency range is discussed.
[3]  oai:arXiv.org:2001.02540  [pdf] - 2028444
Nonlinear Effects in Superconducting Thin Film Microwave Resonators
Comments: 55 pages, 15 figures
Submitted: 2020-01-06
We discuss how reactive and dissipative non-linearities affect the intrinsic response of superconducting thin-film resonators. We explain how most, if not all, of the complex phenomena commonly seen can be described by a model in which the underlying resonance is a single-pole Lorentzian, but whose centre frequency and quality factor change as external parameters, such as readout power and frequency, are varied. What is seen during a vector-network-analyser measurement is series of samples taken from an ideal Lorentzian that is shifting and spreading as the readout frequency is changed. According to this model, it is perfectly proper to refer to, and measure, the resonant frequency and quality factor of the underlying resonance, even though the swept-frequency curves appear highly distorted and hysteretic. In those cases where the resonance curve is highly distorted, the specific shape of the trajectory in the Argand plane gives valuable insights into the second-order physical processes present. We discuss the formulation and consequences of this approach in the case of non-linear kinetic inductance, two-level-system loss, quasiparticle generation, and a generic model based on a power-law form. The generic model captures the key features of specific dissipative non-linearities, but additionally leads to insights into how general dissipative processes create characteristic forms in the Argand plane. We provide detailed formulations in each case, and indicate how they lead to the wide variety of phenomena commonly seen in experimental data. We also explain how the properties of the underlying resonance can be extracted from this data. Overall, our paper provides a self-contained compendium of behaviour that will help practitioners interpret and determine important parameters from distorted swept-frequency measurements.
[4]  oai:arXiv.org:1807.06423  [pdf] - 1718603
The SAFARI Detector System
Comments: 7 pages, 3 figures, Proc. SPIE 10708, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX, 107080K (9 July 2018); (fixed typo in abstract)
Submitted: 2018-07-17, last modified: 2018-07-18
We give an overview of the baseline detector system for SAFARI, the prime focal-plane instrument on board the proposed space infrared observatory, SPICA. SAFARI's detectors are based on superconducting Transition Edge Sensors (TES) to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to read out the total of ~3500 detectors we use frequency domain multiplexing (FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID preamplifier reads out 160 detectors. We describe the detector system and discuss some of the considerations that informed its design.
[5]  oai:arXiv.org:1805.06215  [pdf] - 1684638
Proximity effect model for x-ray Transition Edge Sensors
Comments:
Submitted: 2018-05-16, last modified: 2018-05-17
Transition Edge Sensors are ultra-sensitive superconducting detectors with applications in many areas of research, including astrophysics. The device consists of a superconducting thin film, often with additional normal metal features, held close to its transition temperature and connected to two superconducting leads of a higher transition temperature. There is currently no way to reliably assess the performance of a particular device geometry or material composition without making and testing the device. We have developed a proximity effect model based on the Usadel equations to predict the effects of device geometry and material composition on sensor performance. The model is successful in reproducing I-V curves for two devices currently under study. We use the model to suggest the optimal size and geometry for TESs, considering how small the devices can be made before their performance is compromised. In the future, device modelling prior to manufacture will reduce the need for time-consuming and expensive testing.
[6]  oai:arXiv.org:1803.10438  [pdf] - 1747876
SPICA - a large cryogenic infrared space telescope Unveiling the obscured Universe
Comments: 34 pages, 22 figures, paper accepted for publication in PASA on 2nd February 2018, part of the PASA SPICA Special Issue
Submitted: 2018-03-28
Measurements in the infrared wavelength domain allow us to assess directly the physical state and energy balance of cool matter in space, thus enabling the detailed study of the various processes that govern the formation and early evolution of stars and planetary systems in galaxies over cosmic time. Previous infrared missions, from IRAS to Herschel, have revealed a great deal about the obscured Universe, but sensitivity has been limited because up to now it has not been possible to fly a telescope that is both large and cold. SPICA is a mission concept aimed at taking the next step in mid- and far-infrared observational capability by combining a large and cold telescope with instruments employing state-of-the-art ultra-sensitive detectors. The mission concept foresees a 2.5-meter diameter telescope cooled to below 8 K. With cooling provided by mechanical coolers instead of depending on a limited cryogen supply, the mission lifetime can extend significantly beyond the required three years. SPICA offers instrumentation with spectral resolving powers ranging from R ~50 through 11000 in the 17-230 $\mu$m domain as well as R~28.000 spectroscopy between 12 and 18 $\mu$m. Additionally SPICA will provide efficient 30-37 $\mu$m broad band mapping, and polarimetric imaging in the 100-350 $\mu$m range. SPICA will provide unprecedented spectroscopic sensitivity of ~5 x $10^{-20}$ W/m$^2$ (5$\sigma$/1hr) - at least two orders of magnitude improvement over what has been attained to date. With this exceptional leap in performance, new domains in infrared astronomy will become accessible, allowing us, for example, to unravel definitively galaxy evolution and metal production over cosmic time, to study dust formation and evolution from very early epochs onwards, and to trace the formation history of planetary systems.
[7]  oai:arXiv.org:1703.10494  [pdf] - 1582253
Modelling proximity effects in Transition Edge Sensors to investigate the influence of lateral metal structures
Comments:
Submitted: 2017-03-30
The bilayers of Transition Edge Sensors (TESs) are often modified with additional normal-metal features such as bars or dots. Previous device measurements suggest that these features improve performance, reducing electrical noise and altering response times. However, there is currently no numerical model to predict and quantify these effects. Here we extend existing techniques based on Usadel's equations to describe TESs with normal-metal features. We show their influence on the principal TES characteristics, such as the small-signal electrothermal parameters $\alpha$ and $\beta$ and the superconducting transition temperature $T_{c}$. Additionally, we examine the effects of an applied magnetic field on the device performance. Our model predicts a decrease in $T_{c}$, $\alpha$ and $\beta$ as the number of lateral metal structures is increased. We also obtain a relationship between the length $L$ of a TES and its critical temperature, $T_{c} \propto L^{-0.7}$ for a bilayer with normal-metal bars. We predict a periodic magnetic flux dependence of $\alpha, \beta$ and $I_{c}$. Our results demonstrate good agreement with published experimental data, which also show the reduction of $\alpha$, $\beta$ and $T_{c}$ with increasing number of bars. The observed Fraunhofer dependence of critical current on magnetic flux is also anticipated by our model. The success of this model in predicting the effects of additional structures suggests that in the future numerical methods can be used to better inform the design of TESs, prior to device processing.
[8]  oai:arXiv.org:1701.09145  [pdf] - 1578042
Electrothermal Feedback in Kinetic Inductance Detectors
Comments: 11 pages, 10 figures
Submitted: 2017-01-31
In Kinetic Inductance Detectors (KIDs) and other similar applications of superconducting microresonators, both the large and small-signal behaviour of the device may be affected by electrothermal feedback. Microwave power applied to read out the device is absorbed by and heats the superconductor quasiparticles, changing the superconductor conductivity and hence the readout power absorbed in a positive or negative feedback loop. In this work, we explore numerically the implications of an extensible theoretical model of a generic superconducting microresonator device for a typical KID, incorporating recent work on the power flow between superconductor quasiparticles and phonons. This model calculates the large-signal (changes in operating point) and small-signal behaviour of a device, allowing us to determine the effect of electrothermal feedback on device responsivity and noise characteristics under various operating conditions. We also investigate how thermally isolating the device from the bath, for example by designing the device on a membrane only connected to the bulk substrate by thin legs, affects device performance. We find that at a typical device operating point, positive electrothermal feedback reduces the effective thermal conductance from the superconductor quasiparticles to the bath, and so increases responsivity to signal (pair-breaking) power, increases noise from temperature fluctuations, and decreases the Noise Equivalent Power (NEP). Similarly, increasing the thermal isolation of the device while keeping the quasiparticle temperature constant decreases the NEP, but also decreases the device response bandwidth.
[9]  oai:arXiv.org:1505.06191  [pdf] - 1238361
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
Comments:
Submitted: 2015-05-22
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.
[10]  oai:arXiv.org:1411.1565  [pdf] - 981494
Electrothermal Model of Kinetic Inductance Detectors
Comments: This is an author-created, un-copyedited version of an article published in Superconductor Science and Technology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at 10.1088/0953-2048/28/4/045012. Consult Version of Record for changes in response to reviewers
Submitted: 2014-11-06, last modified: 2015-04-20
An electrothermal model of Kinetic Inductance Detectors (KIDs) is described. The non-equilibrium state of the resonator's quasiparticle system is characterized by an effective temperature, which because of readout-power heating is higher than that of the bath. By balancing the flow of energy into the quasiparticle system, it is possible to calculate the steady-state large-signal, small-signal and noise behaviour. Resonance-curve distortion and hysteretic switching appear naturally within the framework. It is shown that an electrothermal feedback process exists, which affects all aspects of behaviour. It is also shown that generation-recombination noise can be interpreted in terms of the thermal fluctuation noise in the effective thermal conductance that links the quasiparticle and phonon systems of the resonator. Because the scheme is based on electrothermal considerations, multiple elements can be added to simulate the behaviour of complex devices, such as resonators on membranes, again taking into account readout power heating.
[11]  oai:arXiv.org:1310.1554  [pdf] - 1380633
PRISM (Polarized Radiation Imaging and Spectroscopy Mission): An Extended White Paper
PRISM Collaboration; André, Philippe; Baccigalupi, Carlo; Banday, Anthony; Barbosa, Domingos; Barreiro, Belen; Bartlett, James; Bartolo, Nicola; Battistelli, Elia; Battye, Richard; Bendo, George; Benoît, Alain; Bernard, Jean-Philippe; Bersanelli, Marco; Béthermin, Matthieu; Bielewicz, Pawel; Bonaldi, Anna; Bouchet, François; Boulanger, François; Brand, Jan; Bucher, Martin; Burigana, Carlo; Cai, Zhen-Yi; Camus, Philippe; Casas, Francisco; Casasola, Viviana; Castex, Guillaume; Challinor, Anthony; Chluba, Jens; Chon, Gayoung; Colafrancesco, Sergio; Comis, Barbara; Cuttaia, Francesco; D'Alessandro, Giuseppe; Da Silva, Antonio; Davis, Richard; de Avillez, Miguel; de Bernardis, Paolo; de Petris, Marco; de Rosa, Adriano; de Zotti, Gianfranco; Delabrouille, Jacques; Désert, François-Xavier; Dickinson, Clive; Diego, Jose Maria; Dunkley, Joanna; Enßlin, Torsten; Errard, Josquin; Falgarone, Edith; Ferreira, Pedro; Ferrière, Katia; Finelli, Fabio; Fletcher, Andrew; Fosalba, Pablo; Fuller, Gary; Galli, Silvia; Ganga, Ken; García-Bellido, Juan; Ghribi, Adnan; Giard, Martin; Giraud-Héraud, Yannick; Gonzalez-Nuevo, Joaquin; Grainge, Keith; Gruppuso, Alessandro; Hall, Alex; Hamilton, Jean-Christophe; Haverkorn, Marijke; Hernandez-Monte\-agudo, Carlos; Herranz, Diego; Jackson, Mark; Jaffe, Andrew; Khatri, Rishi; Kunz, Martin; Lamagna, Luca; Lattanzi, Massimiliano; Leahy, Paddy; Lesgourgues, Julien; Liguori, Michele; Liuzzo, Elisabetta; Lopez-Caniego, Marcos; Macias-Perez, Juan; Maffei, Bruno; Maino, Davide; Mangilli, Anna; Martinez-Gonzalez, Enrique; Martins, Carlos; Masi, Silvia; Massardi, Marcella; Matarrese, Sabino; Melchiorri, Alessandro; Melin, Jean-Baptiste; Mennella, Aniello; Mignano, Arturo; Miville-Deschênes, Marc-Antoine; Monfardini, Alessandro; Murphy, Anthony; Naselsky, Pavel; Nati, Federico; Natoli, Paolo; Negrello, Mattia; Noviello, Fabio; O'Sullivan, Créidhe; Paci, Francesco; Pagano, Luca; Paladino, Rosita; Palanque-Delabrouille, Nathalie; Paoletti, Daniela; Peiris, Hiranya; Perrotta, Francesca; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Pollo, Agnieszka; Ponthieu, Nicolas; Remazeilles, Mathieu; Ricciardi, Sara; Roman, Matthieu; Rosset, Cyrille; Rubino-Martin, Jose-Alberto; Salatino, Maria; Schillaci, Alessandro; Shellard, Paul; Silk, Joseph; Starobinsky, Alexei; Stompor, Radek; Sunyaev, Rashid; Tartari, Andrea; Terenzi, Luca; Toffolatti, Luigi; Tomasi, Maurizio; Trappe, Neil; Tristram, Matthieu; Trombetti, Tiziana; Tucci, Marco; Van de Weijgaert, Rien; Van Tent, Bartjan; Verde, Licia; Vielva, Patricio; Wandelt, Ben; Watson, Robert; Withington, Stafford
Comments: Figure 8 replaced by the correct version, affiliations of authors added, and minor changes to match the published JCAP version
Submitted: 2013-10-06, last modified: 2014-03-27
PRISM (Polarized Radiation Imaging and Spectroscopy Mission) was proposed to ESA in May 2013 as a large-class mission for investigating within the framework of the ESA Cosmic Vision program a set of important scientific questions that require high resolution, high sensitivity, full-sky observations of the sky emission at wavelengths ranging from millimeter-wave to the far-infrared. PRISM's main objective is to explore the distant universe, probing cosmic history from very early times until now as well as the structures, distribution of matter, and velocity flows throughout our Hubble volume. PRISM will survey the full sky in a large number of frequency bands in both intensity and polarization and will measure the absolute spectrum of sky emission more than three orders of magnitude better than COBE FIRAS. The aim of this Extended White Paper is to provide a more detailed overview of the highlights of the new science that will be made possible by PRISM
[12]  oai:arXiv.org:1401.4395  [pdf] - 772465
The CAMbridge Emission Line Surveyor (CAMELS)
Comments: Submitted to the proceedings of the 24th International Symposium on Space Terahertz Technology (ISSTT), held in Groningen, The Netherlands, April 8-10 2013
Submitted: 2014-01-17
The CAMbridge Emission Line Surveyor (CAMELS) is a pathfinder program to demonstrate on-chip spectrometry at millimetre wavelengths. CAMELS will observe at frequencies from 103-114.7 GHz, providing 512 channels with a spectral resolution of R = 3000. In this paper we describe the science goals of CAMELS, the current system level design for the instrument and the work we are doing on the detailed designs of the individual components. In addition, we will discuss our efforts to understand the impact that the design and calibration of the filter bank on astronomical performance. The shape of the filter channels, the degree of overlap and the nature of the noise all effect how well the parameters of a spectral line can be recovered. We have developed a new and rigorous method for analysing performance, based on the concept of Fisher information. This can in be turn coupled to a detailed model of the science case, allowing design trade-offs to be properly investigated.
[13]  oai:arXiv.org:1307.7278  [pdf] - 699289
Partially Coherent Optical Modelling of the Ultra-Low-Noise Far-Infrared Imaging Arrays on the SPICA Mission
Comments:
Submitted: 2013-07-27
We have developed a range of theoretical and numerical techniques for modeling the multi-mode, 210-34 micron, ultra-low-noise Transition Edge Sensors that will be used on the SAFARI instrument on the ESA/JAXA cooled-aperture FIR space telescope SPICA. The models include a detailed analysis of the resistive and reactive properties of thin superconducting absorbing films, and a partially coherent mode-matching analysis of patterned films in multi-mode waveguide. The technique allows the natural optical modes, modal responsivities, and Stokes maps of complicated structures comprising patterned films in profiled waveguides and cavities to be determined.
[14]  oai:arXiv.org:1306.2259  [pdf] - 1251866
PRISM (Polarized Radiation Imaging and Spectroscopy Mission): A White Paper on the Ultimate Polarimetric Spectro-Imaging of the Microwave and Far-Infrared Sky
PRISM Collaboration; Andre, Philippe; Baccigalupi, Carlo; Barbosa, Domingos; Bartlett, James; Bartolo, Nicola; Battistelli, Elia; Battye, Richard; Bendo, George; Bernard, Jean-Philippe; Bersanelli, Marco; Bethermin, Matthieu; Bielewicz, Pawel; Bonaldi, Anna; Bouchet, Francois; Boulanger, Francois; Brand, Jan; Bucher, Martin; Burigana, Carlo; Cai, Zhen-Yi; Casasola, Viviana; Castex, Guillaume; Challinor, Anthony; Chluba, Jens; Colafrancesco, Sergio; Cuttaia, Francesco; D'Alessandro, Giuseppe; Davis, Richard; de Avillez, Miguel; de Bernardis, Paolo; de Petris, Marco; de Rosa, Adriano; de Zotti, Gianfranco; Delabrouille, Jacques; Dickinson, Clive; Diego, Jose Maria; Falgarone, Edith; Ferreira, Pedro; Ferriere, Katia; Finelli, Fabio; Fletcher, Andrew; Fuller, Gary; Galli, Silvia; Ganga, Ken; Garcia-Bellido, Juan; Ghribi, Adnan; Gonzalez-Nuevo, Joaquin; Grainge, Keith; Gruppuso, Alessandro; Hall, Alex; Hernandez-Monteagudo, Carlos; Jackson, Mark; Jaffe, Andrew; Khatri, Rishi; Lamagna, Luca; Lattanzi, Massimiliano; Leahy, Paddy; Liguori, Michele; Liuzzo, Elisabetta; Lopez-Caniego, Marcos; Macias-Perez, Juan; Maffei, Bruno; Maino, Davide; Masi, Silvia; Mangilli, Anna; Massardi, Marcella; Matarrese, Sabino; Melchiorri, Alessandro; Melin, Jean-Baptiste; Mennella, Aniello; Mignano, Arturo; Miville-Deschenes, Marc-Antoine; Nati, Federico; Natoli, Paolo; Negrello, Mattia; Noviello, Fabio; Paci, Francesco; Paladino, Rosita; Paoletti, Daniela; Perrotta, Francesca; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Ricciardi, Sara; Roman, Matthieu; Rubino-Martin, Jose-Alberto; Salatino, Maria; Schillaci, Alessandro; Shellard, Paul; Silk, Joseph; Stompor, Radek; Sunyaev, Rashid; Tartari, Andrea; Terenzi, Luca; Toffolatti, Luigi; Tomasi, Maurizio; Trombetti, Tiziana; Tucci, Marco; Van Tent, Bartjan; Verde, Licia; Wandelt, Ben; Withington, Stafford
Comments: 20 pages Latex
Submitted: 2013-06-10
PRISM (Polarized Radiation Imaging and Spectroscopy Mission) was proposed to ESA in response to the Call for White Papers for the definition of the L2 and L3 Missions in the ESA Science Programme. PRISM would have two instruments: (1) an imager with a 3.5m mirror (cooled to 4K for high performance in the far-infrared---that is, in the Wien part of the CMB blackbody spectrum), and (2) an Fourier Transform Spectrometer (FTS) somewhat like the COBE FIRAS instrument but over three orders of magnitude more sensitive. Highlights of the new science (beyond the obvious target of B-modes from gravity waves generated during inflation) made possible by these two instruments working in tandem include: (1) the ultimate galaxy cluster survey gathering 10e6 clusters extending to large redshift and measuring their peculiar velocities and temperatures (through the kSZ effect and relativistic corrections to the classic y-distortion spectrum, respectively) (2) a detailed investigation into the nature of the cosmic infrared background (CIB) consisting of at present unresolved dusty high-z galaxies, where most of the star formation in the universe took place, (3) searching for distortions from the perfect CMB blackbody spectrum, which will probe a large number of otherwise inaccessible effects (e.g., energy release through decaying dark matter, the primordial power spectrum on very small scales where measurements today are impossible due to erasure from Silk damping and contamination from non-linear cascading of power from larger length scales). These are but a few of the highlights of the new science that will be made possible with PRISM.
[15]  oai:arXiv.org:1208.0282  [pdf] - 1150439
SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
Comments: In press. Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Submitted: 2012-08-01
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days survey covering 25% of the sky.
[16]  oai:arXiv.org:1208.0281  [pdf] - 544717
The Large-Scale Polarization Explorer (LSPE)
Comments: In press. Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Submitted: 2012-08-01
The LSPE is a balloon-borne mission aimed at measuring the polarization of the Cosmic Microwave Background (CMB) at large angular scales, and in particular to constrain the curl component of CMB polarization (B-modes) produced by tensor perturbations generated during cosmic inflation, in the very early universe. Its primary target is to improve the limit on the ratio of tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7% confidence. A second target is to produce wide maps of foreground polarization generated in our Galaxy by synchrotron emission and interstellar dust emission. These will be important to map Galactic magnetic fields and to study the properties of ionized gas and of diffuse interstellar dust in our Galaxy. The mission is optimized for large angular scales, with coarse angular resolution (around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload will fly in a circumpolar long duration balloon mission during the polar night. Using the Earth as a giant solar shield, the instrument will spin in azimuth, observing a large fraction of the northern sky. The payload will host two instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters, using large throughput multi-mode bolometers and rotating Half Wave Plates (HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz. The wide frequency coverage will allow optimal control of the polarized foregrounds, with comparable angular resolution at all frequencies.
[17]  oai:arXiv.org:1102.2181  [pdf] - 958427
COrE (Cosmic Origins Explorer) A White Paper
Comments: 90 pages Latex 15 figures (revised 28 April 2011, references added, minor errors corrected)
Submitted: 2011-02-10, last modified: 2011-04-29
COrE (Cosmic Origins Explorer) is a fourth-generation full-sky, microwave-band satellite recently proposed to ESA within Cosmic Vision 2015-2025. COrE will provide maps of the microwave sky in polarization and temperature in 15 frequency bands, ranging from 45 GHz to 795 GHz, with an angular resolution ranging from 23 arcmin (45 GHz) and 1.3 arcmin (795 GHz) and sensitivities roughly 10 to 30 times better than PLANCK (depending on the frequency channel). The COrE mission will lead to breakthrough science in a wide range of areas, ranging from primordial cosmology to galactic and extragalactic science. COrE is designed to detect the primordial gravitational waves generated during the epoch of cosmic inflation at more than $3\sigma $ for $r=(T/S)>=10^{-3}$. It will also measure the CMB gravitational lensing deflection power spectrum to the cosmic variance limit on all linear scales, allowing us to probe absolute neutrino masses better than laboratory experiments and down to plausible values suggested by the neutrino oscillation data. COrE will also search for primordial non-Gaussianity with significant improvements over Planck in its ability to constrain the shape (and amplitude) of non-Gaussianity. In the areas of galactic and extragalactic science, in its highest frequency channels COrE will provide maps of the galactic polarized dust emission allowing us to map the galactic magnetic field in areas of diffuse emission not otherwise accessible to probe the initial conditions for star formation. COrE will also map the galactic synchrotron emission thirty times better than PLANCK. This White Paper reviews the COrE science program, our simulations on foreground subtraction, and the proposed instrumental configuration.
[18]  oai:arXiv.org:1101.5916  [pdf] - 298555
Transition Edge Sensor Thermometry for On-chip Materials Characterization
Comments: Published in proceedings 21ST INTERNATIONAL SYMPOSIUM ON SPACE TERAHERTZ TECHNOLOGY, OXFORD, 23-25 MARCH, 2010
Submitted: 2011-01-31
The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge Sensors (TESs) permits measurements of thermal parameters of mesoscopic systems with unprecedented precision. We describe a radiometric technique for differential measurements of materials characteristics at low temperatures (below about 3K). The technique relies on the very broadband thermal radiation that couples between impedance-matched resistors that terminate a Nb superconducting microstrip and the power exchanged is measured using a TES. The capability of the TES to deliver fast, time-resolved thermometry further expands the parameter space: for example to investigate time-dependent heat capacity. Thermal properties of isolated structures can be measured in geometries that eliminate the need for complicating additional components such as the electrical wires of the thermometer itself. Differential measurements allow easy monitoring of temperature drifts in the cryogenic environment. The technique is rapid to use and easily calibrated. Preliminary results will be discussed.
[19]  oai:arXiv.org:0907.3610  [pdf] - 1003008
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk Maxwell Telescope
Comments: MNRAS Accepted 2009 July 2. 18 pages, 25 figures and 6 tables
Submitted: 2009-07-21
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements over single-detector counterparts in calibration and image quality. Receiver temperatures are $\sim$120 K across the whole band and system temperatures of $\sim$300K are reached routinely under good weather conditions. The system includes a single-sideband filter so these are SSB figures. Used in conjunction with ACSIS, the system can produce large-scale maps rapidly, in one or more frequency settings, at high spatial and spectral resolution. Fully-sampled maps of size 1 square degree can be observed in under 1 hour. The scientific need for array receivers arises from the requirement for programmes to study samples of objects of statistically significant size, in large-scale unbiased surveys of galactic and extra-galactic regions. Along with morphological information, the new spectral imaging system can be used to study the physical and chemical properties of regions of interest. Its three-dimensional imaging capabilities are critical for research into turbulence and dynamics. In addition, HARP/ACSIS will provide highly complementary science programmes to wide-field continuum studies, and produce the essential preparatory work for submillimetre interferometers such as the SMA and ALMA.
[20]  oai:arXiv.org:0805.3690  [pdf] - 12907
Detecting the B-mode Polarisation of the CMB with Clover
Comments: 5 pages, 3 figures. To appear in the proceedings of the XXXXIIIrd Rencontres de Moriond "Cosmology". Figure 1 updated
Submitted: 2008-05-23, last modified: 2008-06-03
We describe the objectives, design and predicted performance of Clover, which is a ground-based experiment to measure the faint ``B-mode'' polarisation pattern in the cosmic microwave background (CMB). To achieve this goal, clover will make polarimetric observations of approximately 1000 deg^2 of the sky in spectral bands centred on 97, 150 and 225 GHz. The observations will be made with a two-mirror compact range antenna fed by profiled corrugated horns. The telescope beam sizes for each band are 7.5, 5.5 and 5.5 arcmin, respectively. The polarisation of the sky will be measured with a rotating half-wave plate and stationary analyser, which will be an orthomode transducer. The sky coverage combined with the angular resolution will allow us to measure the angular power spectra between 20 < l < 1000. Each frequency band will employ 192 single polarisation, photon noise limited TES bolometers cooled to 100 mK. The background-limited sensitivity of these detector arrays will allow us to constrain the tensor-to-scalar ratio to 0.026 at 3sigma, assuming any polarised foreground signals can be subtracted with minimal degradation to the 150 GHz sensitivity. Systematic errors will be mitigated by modulating the polarisation of the sky signals with the rotating half-wave plate, fast azimuth scans and periodic telescope rotations about its boresight. The three spectral bands will be divided into two separate but nearly identical instruments - one for 97 GHz and another for 150 and 225 GHz. The two instruments will be sited on identical three-axis mounts in the Atacama Desert in Chile near Pampa la Bola. Observations are expected to begin in late 2009.
[21]  oai:arXiv.org:0709.0461  [pdf] - 4551
Simulations of astronomical imaging phased arrays
Comments: 16 pages, 26 figures, submitted to Journal of the Optical Society of America A
Submitted: 2007-09-04
We describe a theoretical procedure for analyzing astronomical phased arrays with overlapping beams, and apply the procedure to simulate a simple example. We demonstrate the effect of overlapping beams on the number of degrees of freedom of the array, and on the ability of the array to recover a source. We show that the best images are obtained using overlapping beams, contrary to common practise, and show how the dynamic range of a phased array directly affects the image quality.
[22]  oai:arXiv.org:0707.1580  [pdf] - 2978
Theoretical Analysis of Astronomical Phased Arrays
Comments:
Submitted: 2007-07-11
Low-noise phased arrays are essential for the next generation of microwave and submillimetre wave astronomy. We analyze their behaviour from a functional perspective, and show that their operation is intimately related to the mathematical theory of frames. No assumptions are made about the orthogonality or linear independence of the synthesised beams. Frame theory allows an unambiguous assessment of whether the outputs of an array can be used to observe a field or brightness distribution within a given class. Image reconstruction is carried out using dual beams. We identify the natural modes of phased arrays, and carry out an analysis of noise. The scheme allows the expectation values, the mean-square fluctuations, and the correlations between fluctuations at the output ports of a phased array to be determined for a source in any state of spatial coherence. Both classical and photon-counting statistics are included. Our model is conceptually powerful, and suggests many simulation and image recovery techniques.
[23]  oai:arXiv.org:astro-ph/0703141  [pdf] - 89950
Simulations of partially coherent focal plane imaging arrays: Fisher matrix approach to performance evaluation
Comments: 14 pages, 7 figures, submitted to MNRAS 7th March 2007
Submitted: 2007-03-07
Focal plane arrays of bolometers are increasingly employed in astronomy at far--infrared to millimetre wavelengths. The focal plane fields and the detectors are both partially coherent in these systems, but no account has previously been taken of the effect of partial coherence on array performance. In this paper, we use our recently developed coupled--mode theory of detection together with Fisher information matrix techniques from signal processing to characterize the behaviour of partially coherent imaging arrays. We investigate the effects of the size and coherence length of both the source and the detectors, and the packing density of the array, on the amount of information that can be extracted from observations with such arrays.
[24]  oai:arXiv.org:astro-ph/0702732  [pdf] - 89786
Diffraction Considerations for Planar Detectors in the Few-Mode Limit
Comments: 20 pages, 8 figures
Submitted: 2007-02-28
Filled arrays of bolometers are currently being employed for use in astronomy from the far-infrared through millimeter parts of the electromagnetic spectrum. Because of the large range of wavelengths for which such detectors are applicable, the number of modes supported by a pixel will vary according to the specific application of a given available technology. We study the dependence of image fidelity and induced polarization on the size of the pixel by employing a formalism in which diffraction due to the pixel boundary is treated by propagating the second-order statistical correlations of the radiation field through a model optical system. We construct polarized beam pattern images of square pixels for various ratios of p/\lambda where p is the pixel size and \lambda is the wavelength of the radiation under consideration. For the limit in which few modes are supported by the pixel (p/\lambda<1), we find that the diffraction due to the pixel edges is non-negligible and hence must be considered along with the telescope diffraction pattern in modeling the ultimate spatial resolution of an imaging system. For the case in which the pixel is over-moded (p/\lambda>1), the geometric limit is approached as expected. This technique gives a quantitative approach to optimize the imaging properties of arrays of planar detectors in the few-mode limit.
[25]  oai:arXiv.org:astro-ph/0609320  [pdf] - 84912
Optical Physics of Imaging and Interferometric Phased Arrays
Comments:
Submitted: 2006-09-12
Microwave, submillimetre-wave, and far-infrared phased arrays are of considerable importance for astronomy. We consider the behaviour imaging phased arrays and interferometric phased arrays from a functional perspective. It is shown that the average powers, field correlations, power fluctuations, and correlations between power fluctuations at the output ports of an imaging or interferometric phased array can be found once the synthesised reception patterns are known. The reception patterns do not have to be orthogonal or even linearly independent. It is shown that the operation of phased arrays is intimately related to the mathematical theory of frames, and that the theory of frames can be used to determine the degree to which any class of intensity or field distribution can be reconstructed unambiguously from the complex amplitudes of the travelling waves at the output ports. The theory can be used to set up a likelihood function that can, through Fisher information, be used to determine the degree to which a phased array can be used to recover the parameters of a parameterised source. For example, it would be possible to explore the way in which a system, perhaps interferometric, might observe two widely separated regions of the sky simultaneously.
[26]  oai:arXiv.org:astro-ph/0608285  [pdf] - 84162
Prototype finline-coupled TES bolometers for CLOVER
Comments: 4 pages, 6 figures; to appear in the Proceedings of the 17th International Symposium on Space Terahertz Technology, held 10-12 May 2006 in Paris
Submitted: 2006-08-14
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to ensure a 100% operational focal plane. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and present preliminary measurements of the prototype detectors performance.
[27]  oai:arXiv.org:astro-ph/0607067  [pdf] - 1463183
TES imaging array technology for CLOVER
Comments: 9 pages, 7 figures, SPIE Orlando 24-31 May 2006, Conference 6275
Submitted: 2006-07-05
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to guarantee fully functioning focal planes. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and give an update on the detector development.
[28]  oai:arXiv.org:astro-ph/0407148  [pdf] - 65990
CLOVER - A new instrument for measuring the B-mode polarization of the CMB
Comments: 4 pages, 5 figures. To appear in the proceedings of the XXXVIXth Rencontres de Moriond "Exploring the Universe"
Submitted: 2004-07-07
We describe the design and expected performance of Clover, a new instrument designed to measure the B-mode polarization of the cosmic microwave background. The proposed instrument will comprise three independent telescopes operating at 90, 150 and 220 GHz and is planned to be sited at Dome C, Antarctica. Each telescope will feed a focal plane array of 128 background-limited detectors and will measure polarized signals over angular multipoles 20 < l < 1000. The unique design of the telescope and careful control of systematics should enable the B-mode signature of gravitational waves to be measured to a lensing-confusion-limited tensor-to-scalar ratio r~0.005.
[29]  oai:arXiv.org:astro-ph/0401160  [pdf] - 62030
Modal decomposition of astronomical images with application to shapelets
Comments: 12 pages, 17 figures, submitted to MNRAS
Submitted: 2004-01-09
The decomposition of an image into a linear combination of digitised basis functions is an everyday task in astronomy. A general method is presented for performing such a decomposition optimally into an arbitrary set of digitised basis functions, which may be linearly dependent, non-orthogonal and incomplete. It is shown that such circumstances may result even from the digitisation of continuous basis functions that are orthogonal and complete. In particular, digitised shapelet basis functions are investigated and are shown to suffer from such difficulties. As a result the standard method of performing shapelet analysis produces unnecessarily inaccurate decompositions. The optimal method presented here is shown to yield more accurate decompositions in all cases.
[30]  oai:arXiv.org:astro-ph/0109438  [pdf] - 44937
The SCUBA Bright Quasar Survey (SBQS): 850micron observations of the z>4 sample
Comments: 16 pages, 11 figures. Accepted by Monthly Notices of the Royal Astronomical Society
Submitted: 2001-09-25
We present initial results of a new, systematic search for massive star-formation in the host galaxies of the most luminous and probably most massive z>=4 radio-quiet quasars (M(B) <= -27.5; nuL(nu)(1450Ang)>10^13Lsun). A total of 38 z>=4 radio-quiet quasars have been observed at the JCMT using SCUBA at 850microns: 8 were detected (>3sigma) with S(850microns)>~ 10mJy (submillimetre-loud). The new detections almost triple the number of optically selected, submillimetre-loud z>~4 radio-quiet quasars known to date. We include a detailed description of how our quasar sample is defined in terms of radio and optical properties. There is no strong evidence for trends in either detectability or 850microns flux with absolute magnitude, M(B). We find that the weighted mean flux of the undetected sources is 2.0 +/- 0.6mJy, consistent with an earlier estimate of \~3mJy based on more sensitive observations of a sample z>~4 radio-quiet quasars (McMahon et al., 1999). This corresponds to an inferred starformation rate of \~1000Msun/yr, similar to Arp220. The typical starformation timescale for the submillimetre-bright sources is ~1Gyr, 10 times longer than the typical accretion-driven e-folding timescale of ~5x10^7 years. Our 850micron detection of the z=4.4 quasar PSS J1048+4407 when analysed in conjunction with 1.2mm single-dish and interferometric observations suggests that this source is resolved on angular scales of 1-2" (6-12 kpc). In addition, we present a new optical spectrum of this source, identifying it as a broad absorption line (BAL) quasar. The new redshift is outside that covered in a recent CO line search by Guilloteau et al., (1999), highlighting the need for accurate redshifts for the obervation and interpretation of high-redshift line studies.
[31]  oai:arXiv.org:astro-ph/9907239  [pdf] - 107464
Submillimetre observations of luminous z>4 radio-quiet quasars and the contribution of AGN to the submm source population
Comments: To appear in MNRAS, 5 pages, Latex with MNRAS macros
Submitted: 1999-07-18
We present sensitive 850 micron SCUBA photometry of a statistically-complete sample of six of the most luminous, z>4 radio-quiet quasars, reaching noise levels comparable with the deep blank sky surveys. One quasar (BR2237-0607; z=4.55) is detected at 850micron with a flux of 5.0mJy (4.5sigma), whilst a second (BR0019-1522; z=4.52) has a detection at the 2 sigma level. When combined with our previous millimetre measurements of z>4 quasars, we find that there is a large range (5--10) in far infrared (FIR) luminosity at fixed UV luminosity, and that the typical quasar has a L_FIR and mass of cool (50K) dust similar to that of the archetyepal low redshift (z=0.018) ultraluminous IRAS} galaxy Arp220. If one assumes a fiducial FIR luminosity of 5x10^12 Lsun for for all quasars with M_B<-23, we find that around 15 per cent of the sources in the SCUBA deep surveys could be classical broad-lined radio-quiet AGN. Thus if one considers the observed ratio of Seyfert II to Seyfert I galaxies at low redshift and any contribution from totally optically obscured AGN, a significant fraction of the SCUBA source population will harbour AGN and hence the inferred star formation rates from submm fluxes may be overestimated if the active nuclei are bolometrically dominant or the IMF is top heavy.